Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEEE Open Journal of Ultrasonics Ferroelectrics and Frequency Control

Nitrogen-Pressure Dependence of Coherent Population Trapping Signal Characteristics in Microfabricated Rubidium Vapor Cells

Shun Kiyose, Masahiro Fukuoka, Yusuke Odagiri, Satoshi Hatano, Shigeyoshi Goka, Motoaki Hara, Yoshikazu Hirai

Published Jan 1, 2026• 0 citations
Publisher

Abstract

Controlling buffer-gas conditions in vapor cells is essential for frequency stabilization and atomic-clock performance. This study investigated the dependence of coherent population trapping (CPT) signal characteristics on nitrogen (N ${}_{2}$ ) buffer-gas pressure in micro-fabricated vapor cells containing natural-abundance rubidium (Rb) generated from Rb azide (RbN ${}_{3}$ ) for chip-scale atomic clocks. A wafer-level fabrication method enabling individual control of N2 pressure was developed by inkjet patterning of RbN3 and subsequent krypton fluoride (KrF) excimer laser decomposition. An increasing N2 pressure was found to reduce the CPT linewidth and cause a significant decrease in the signal amplitude, which resulted in monotonic degradation in the CPT figure of merit with higher pressures. A CPT-based laser frequency stabilization method that locked the laser wavelength to the CPT resonance peak yielded significantly larger signal amplitudes than a conventional absorption-based method in the low-pressure regime below 8 kPa. These results show that CPT performance in micro-fabricated Rb vapor cells is more restricted by the signal amplitude rather than the linewidth. They also offer practical buffer-gas design guidelines for enhancing short-term frequency stability in chip-scale atomic clocks.

DOI
10.1109/ojuffc.2026.3739231

Related papers

Characterizing passive coherent population trapping resonance in a cesium vapor cell filled with neon buffer gas

Zhi Liu, Jieying Wang, Wen-Ting Diao +2 more

We present a pair of phase-locked lasers with a 9.2-GHz frequency difference through the injection locking of a master laser to the RF-modulation sideband of a slave diode laser. Using this laser system, a coherent population trapping (CPT) signal with a typical linewidth of ∼ 182 Hz is obtained in a cesium vapor cell filled with 30 Torr (4 kPa) of neon as the buffer gas. We investigate the influence of the partial pressure of the neon buffer gas on the CPT linewidth, amplitude, and frequency shift. The results may offer some references for CPT atomic clocks and CPT atomic magnetometers.

Chinese Physics B•Apr 1, 2013•3 citations

Investigation of coherent population trapping signals in 87Rb cells with buffer gas

M I Fedorov, Ермак Сергей Викторович, Mikhail V. Petrenko +2 more

Characteristics of CPT (coherent population trapping) signal are investigated in small-size glass vapor cells containing 87 Rb and Ne buffer gas with narrow linewidth laser pumping on D 2 line. Parameters of CPT absorption signals are measured using small-size vapor cells with Ne buffer gas pressure in range of 200-400 Torr, cell temperature in range of 65-120 °C and values of laser pumping power of 30-400 μW/cm 2 . Optimum conditions, under which the minimal value of short-term instability of resonance line is achieved, are obtained in experiments. CPT signals using vapor cells based on integrated technologies containing 87 Rb in atmosphere of Ne are also investigated. The CPT signals with typical linewidths of 2-3 kHz and signal-to-noise ratio of 1500 in 1 Hz bandwidth are observed, which allows one to provide relative frequency instability of 10 -11 at 100 s.

Journal of Physics Conference Series•Nov 1, 2016•2 citations

Microfabricated cells for chip-scale atomic clock based on coherent population trapping: Fabrication and investigation

Ермак Сергей Викторович, V. V. Semenov, Пятышев Евгений Нилович +5 more

A universal method for fabrication of miniature cells for frequency standards and quantum magnetometers containing 87Rb atoms in the atmosphere of inert gas neon based on integrated technologies is considered. The results of experimental studies of coherent population trapping signals observed for a series of cells which provided recovery of vapors of an alkali metal from the rubidium dichromate salt with the help of laser radiation are presented. The coherent population trapping signals with a typical linewidth of 2–3 kHz and a signal-to-noise ratio of 1500 in the 1-Hz bandwidth were observed, which allows one to provide a relative frequency stability of atomic clock of 10−11 at 100 s.

St Petersburg Polytechnical University Journal Physics and Mathematics•Mar 1, 2015•10 citations

Coherent population trapping in small- and chip-scale 87Rb vapor cells with buffer gas

Ермак Сергей Викторович, V. V. Semenov, Mikhail V. Petrenko +1 more

The characteristics of coherent population trapping (CPT) signal were investigated in small-size glass vapor cells containing [Formula: see text]Rb and Ne buffer gas with narrow line-width laser pumping on D2 line. The parameters of CPT signals were measured using small-size vapor cells with Ne buffer gas pressure in the range of 200–400 Torr, cell temperature in the range of 65–120 [Formula: see text]C and the values of laser pumping power of 30–400 [Formula: see text]W/cm2. Optimal conditions, under which the minimal value of short-term instability of resonance line is achieved, were obtained in experiments. Orientation frequency shifts of CPT resonance using glass [Formula: see text]Rb vapor cells containing buffer gas and anti-relaxation coating were compared. CPT signals using vapor cells based on integrated technologies containing [Formula: see text]Rb in atmosphere of Ne were also investigated. The CPT signals with typical line widths of 2–3 kHz and signal-to-noise ratio of 1500 in 1 Hz bandwidth are observed, which allows one to provide relative frequency instability of 10[Formula: see text] at 100 s.

International Journal of Modern Physics Conference Series•Jan 1, 2016•3 citations

Wafer-scale fabrication of alkali vapor cells

Yang Li, Marlou R. Slot, Dongyu Sohn +3 more

This paper describes the progress made in developing wafer-scale fabrication process of alkali vapor cells for chip-scale atomic devices such as Coherent Population Trapping (CPT) clocks, optical frequency standards and Rydberg-atom-based sensors. The wafer level fabrication process uses anodic bonding and introduces alkali atoms by chemical reactions of Alkali Chloride with Barium Azide. This method is compatible to make cells with a wide range of buffer gas species and pressures, including evacuated cells. We improve the yield of the cells to above 50%. We will show the residual gas pressures for evacuated cells are mostly consistent with zero within the resolution of the saturation absorption spectroscopy measurement. The temperature coefficients for the CPT spectroscopy are improved with Ar-N2 mixture buffer gas compared with only N2 buffer gas.

Optical and Quantum Sensing and Precision Metrology II•Mar 19, 2025•0 citations

Stabilization method for atomic clocks to detect the maximum coherent-population-trapping resonance signal

Yusuke Odagiri, Satoshi Hatano, Yuichiro Yano +3 more

Abstract Chip-scale atomic clocks based on coherent population trapping (CPT) face challenges due to miniaturized gas cells, which reduces the CPT resonance signal and the absorption signals of alkali atoms. To overcome this, we propose a method that simultaneously stabilizes the laser wavelength and microwave modulation frequency without relying on absorption line detection. Our approach enables stabilization at the point where the amplitude of the CPT resonance signal is maximized, making it suitable for compact atomic clocks. The system uses three lock-in amplifiers: one is used to stabilize the RF modulation frequency, and the other two are used for detecting the amplitude of the CPT resonance and stabilizing the laser wavelength. The Allan deviation measurements demonstrate a 1.4-fold improvement in short-term stability compared to conventional methods, suggesting that the proposed technique is a promising solution for enhancing the performance of small gas-cell atomic clocks.

Japanese Journal of Applied Physics•Jun 1, 2025•2 citations
Controlling buffer-gas conditions in vapor cells is essential for frequency stabilization and atomic-clock performance. This study investigated the dependence of coherent population trapping (CPT) signal characteristics on nitrogen (N 2{}_{2}2​ ) buffer-gas pressure in micro-fabricated vapor cells containing natural-abundance rubidium (Rb) generated from Rb azide (RbN 3{}_{3}3​ ) for chip-scale atomic clocks. A wafer-level fabrication method enabling individual control of N2 pressure was developed by inkjet patterning of RbN3 and subsequent krypton fluoride (KrF) excimer laser decomposition. An increasing N2 pressure was found to reduce the CPT linewidth and cause a significant decrease in the signal amplitude, which resulted in monotonic degradation in the CPT figure of merit with higher pressures. A CPT-based laser frequency stabilization method that locked the laser wavelength to the CPT resonance peak yielded significantly larger signal amplitudes than a conventional absorption-based method in the low-pressure regime below 8 kPa. These results show that CPT performance in micro-fabricated Rb vapor cells is more restricted by the signal amplitude rather than the linewidth. They also offer practical buffer-gas design guidelines for enhancing short-term frequency stability in chip-scale atomic clocks.
We present a pair of phase-locked lasers with a 9.2-GHz frequency difference through the injection locking of a master laser to the RF-modulation sideband of a slave diode laser. Using this laser system, a coherent population trapping (CPT) signal with a typical linewidth of ∼ 182 Hz is obtained in a cesium vapor cell filled with 30 Torr (4 kPa) of neon as the buffer gas. We investigate the influence of the partial pressure of the neon buffer gas on the CPT linewidth, amplitude, and frequency shift. The results may offer some references for CPT atomic clocks and CPT atomic magnetometers.
Characteristics of CPT (coherent population trapping) signal are investigated in small-size glass vapor cells containing 87 Rb and Ne buffer gas with narrow linewidth laser pumping on D 2 line. Parameters of CPT absorption signals are measured using small-size vapor cells with Ne buffer gas pressure in range of 200-400 Torr, cell temperature in range of 65-120 °C and values of laser pumping power of 30-400 μW/cm 2 . Optimum conditions, under which the minimal value of short-term instability of resonance line is achieved, are obtained in experiments. CPT signals using vapor cells based on integrated technologies containing 87 Rb in atmosphere of Ne are also investigated. The CPT signals with typical linewidths of 2-3 kHz and signal-to-noise ratio of 1500 in 1 Hz bandwidth are observed, which allows one to provide relative frequency instability of 10 -11 at 100 s.
A universal method for fabrication of miniature cells for frequency standards and quantum magnetometers containing 87Rb atoms in the atmosphere of inert gas neon based on integrated technologies is considered. The results of experimental studies of coherent population trapping signals observed for a series of cells which provided recovery of vapors of an alkali metal from the rubidium dichromate salt with the help of laser radiation are presented. The coherent population trapping signals with a typical linewidth of 2–3 kHz and a signal-to-noise ratio of 1500 in the 1-Hz bandwidth were observed, which allows one to provide a relative frequency stability of atomic clock of 10−11 at 100 s.
The characteristics of coherent population trapping (CPT) signal were investigated in small-size glass vapor cells containing [Formula: see text]Rb and Ne buffer gas with narrow line-width laser pumping on D2 line. The parameters of CPT signals were measured using small-size vapor cells with Ne buffer gas pressure in the range of 200–400 Torr, cell temperature in the range of 65–120 [Formula: see text]C and the values of laser pumping power of 30–400 [Formula: see text]W/cm2. Optimal conditions, under which the minimal value of short-term instability of resonance line is achieved, were obtained in experiments. Orientation frequency shifts of CPT resonance using glass [Formula: see text]Rb vapor cells containing buffer gas and anti-relaxation coating were compared. CPT signals using vapor cells based on integrated technologies containing [Formula: see text]Rb in atmosphere of Ne were also investigated. The CPT signals with typical line widths of 2–3 kHz and signal-to-noise ratio of 1500 in 1 Hz bandwidth are observed, which allows one to provide relative frequency instability of 10[Formula: see text] at 100 s.
This paper describes the progress made in developing wafer-scale fabrication process of alkali vapor cells for chip-scale atomic devices such as Coherent Population Trapping (CPT) clocks, optical frequency standards and Rydberg-atom-based sensors. The wafer level fabrication process uses anodic bonding and introduces alkali atoms by chemical reactions of Alkali Chloride with Barium Azide. This method is compatible to make cells with a wide range of buffer gas species and pressures, including evacuated cells. We improve the yield of the cells to above 50%. We will show the residual gas pressures for evacuated cells are mostly consistent with zero within the resolution of the saturation absorption spectroscopy measurement. The temperature coefficients for the CPT spectroscopy are improved with Ar-N2 mixture buffer gas compared with only N2 buffer gas.
Abstract Chip-scale atomic clocks based on coherent population trapping (CPT) face challenges due to miniaturized gas cells, which reduces the CPT resonance signal and the absorption signals of alkali atoms. To overcome this, we propose a method that simultaneously stabilizes the laser wavelength and microwave modulation frequency without relying on absorption line detection. Our approach enables stabilization at the point where the amplitude of the CPT resonance signal is maximized, making it suitable for compact atomic clocks. The system uses three lock-in amplifiers: one is used to stabilize the RF modulation frequency, and the other two are used for detecting the amplitude of the CPT resonance and stabilizing the laser wavelength. The Allan deviation measurements demonstrate a 1.4-fold improvement in short-term stability compared to conventional methods, suggesting that the proposed technique is a promising solution for enhancing the performance of small gas-cell atomic clocks.