Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Physics Conference Series

Investigation of coherent population trapping signals in 87Rb cells with buffer gas

M I Fedorov, Ермак Сергей Викторович, Mikhail V. Petrenko, Пятышев Евгений Нилович, V. V. Semenov

Published Nov 1, 2016• 2 citations
Publisher

Abstract

Characteristics of CPT (coherent population trapping) signal are investigated in small-size glass vapor cells containing 87 Rb and Ne buffer gas with narrow linewidth laser pumping on D 2 line. Parameters of CPT absorption signals are measured using small-size vapor cells with Ne buffer gas pressure in range of 200-400 Torr, cell temperature in range of 65-120 °C and values of laser pumping power of 30-400 μW/cm 2 . Optimum conditions, under which the minimal value of short-term instability of resonance line is achieved, are obtained in experiments. CPT signals using vapor cells based on integrated technologies containing 87 Rb in atmosphere of Ne are also investigated. The CPT signals with typical linewidths of 2-3 kHz and signal-to-noise ratio of 1500 in 1 Hz bandwidth are observed, which allows one to provide relative frequency instability of 10 -11 at 100 s.

DOI
10.1088/1742-6596/769/1/012046

Related papers

Coherent population trapping in small- and chip-scale 87Rb vapor cells with buffer gas

Ермак Сергей Викторович, V. V. Semenov, Mikhail V. Petrenko +1 more

The characteristics of coherent population trapping (CPT) signal were investigated in small-size glass vapor cells containing [Formula: see text]Rb and Ne buffer gas with narrow line-width laser pumping on D2 line. The parameters of CPT signals were measured using small-size vapor cells with Ne buffer gas pressure in the range of 200–400 Torr, cell temperature in the range of 65–120 [Formula: see text]C and the values of laser pumping power of 30–400 [Formula: see text]W/cm2. Optimal conditions, under which the minimal value of short-term instability of resonance line is achieved, were obtained in experiments. Orientation frequency shifts of CPT resonance using glass [Formula: see text]Rb vapor cells containing buffer gas and anti-relaxation coating were compared. CPT signals using vapor cells based on integrated technologies containing [Formula: see text]Rb in atmosphere of Ne were also investigated. The CPT signals with typical line widths of 2–3 kHz and signal-to-noise ratio of 1500 in 1 Hz bandwidth are observed, which allows one to provide relative frequency instability of 10[Formula: see text] at 100 s.

International Journal of Modern Physics Conference Series•Jan 1, 2016•3 citations

Coherent population trapping on 87Rb atoms in small-size absorption cells with buffer gas

Ермак Сергей Викторович, Mikhail V. Petrenko, V. V. Semenov

Coherent population trapping (CPT) on 87 Rb atoms in neon atmosphere has been studied in small-size glass absorption cells under conditions of pumping with narrow-band laser radiation at the D 2 line of the main doublet. Parameters of the absorption signal have been measured in 3-mm-diameter cells at buffer gas (Ne) pressures varied within 200–400 Torr, cell temperatures within 65–120°C, and pumping radiation power densities within 30–400 μW/cm 2 . Optimum values of the buffer gas pressures, cell temperature, and pumping power are determined at which the short-term instability of the resonance line is at minimum. Orientational shifts of the CPT resonance signal in gas-filled cells and small-size cells with antirelaxation coating have been compared.

Technical Physics Letters•Feb 1, 2016•11 citations

Pulsed coherent population trapping spectroscopy in microfabricated Cs–Ne vapor cells

Rodolphe Boudot, Vincent N. Maurice, Christophe Gorecki +1 more

Pulsed coherent population trapping (CPT) spectroscopy is applied in buffer-gas filled Cs–Ne vapor microfabricated cells. The properties of the Ramsey-CPT clock transition central fringe (linewidth, signal amplitude, and contrast) are studied versus several experimental parameters, including the Ramsey sequence and the input laser intensity, and are compared to those obtained in the conventional continuous (CW) interrogation mode. In the pulsed case and for short Ramsey-free evolution times TR, the central fringe linewidth is found to exhibit a small but visible power broadening and is measured to be narrower than the value of 1/(2TR) that is reached for long TR. The microwave hyperfine coherence lifetime T2 in the Cs–Ne microcells is measured to be in the 50–500 μs range. Its dependence to the buffer gas pressure or cell temperature is briefly studied.

Journal of the Optical Society of America B•Apr 4, 2018•11 citations

Optimization of the experimental parameters of cesium CPT system

Zhi Liu, Jieying Wang, Wen-Ting Diao +2 more

Based on a Λ-type three-level system consists of cesium (Cs) 6S1/2 (Fg = 3) and 6S1/2 (Fg = 4) long-lived ground states and 6P3/2 (Fe = 4) excited state, we have experimentally measured and theoretically analyzed the characters of coherent population trapping (CPT) resonances in Cs vapor cells with different partial pressure of neon (Ne) as buffer gas around room temperature. The impact of some experimental parameters, such as the relative intensity ratio between two phase-locked laser beams, the laser intensity, with or without buffer gas and the partial pressure of Ne, the temperature and the longitudinal magnetic field, on the CPT resonance was studied in details. With the optimized parameters, we got typical CPT signal with the full-width half-maximum (FWHM) linewidth as narrow as ~ 181 Hz in a Cs vapor cell filled with 30 Torr of Ne as buffer gas.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Nov 29, 2012•1 citation

Characterizing passive coherent population trapping resonance in a cesium vapor cell filled with neon buffer gas

Zhi Liu, Jieying Wang, Wen-Ting Diao +2 more

We present a pair of phase-locked lasers with a 9.2-GHz frequency difference through the injection locking of a master laser to the RF-modulation sideband of a slave diode laser. Using this laser system, a coherent population trapping (CPT) signal with a typical linewidth of ∼ 182 Hz is obtained in a cesium vapor cell filled with 30 Torr (4 kPa) of neon as the buffer gas. We investigate the influence of the partial pressure of the neon buffer gas on the CPT linewidth, amplitude, and frequency shift. The results may offer some references for CPT atomic clocks and CPT atomic magnetometers.

Chinese Physics B•Apr 1, 2013•3 citations

Nitrogen-Pressure Dependence of Coherent Population Trapping Signal Characteristics in Microfabricated Rubidium Vapor Cells

Shun Kiyose, Masahiro Fukuoka, Yusuke Odagiri +4 more

Controlling buffer-gas conditions in vapor cells is essential for frequency stabilization and atomic-clock performance. This study investigated the dependence of coherent population trapping (CPT) signal characteristics on nitrogen (N ${}_{2}$ ) buffer-gas pressure in micro-fabricated vapor cells containing natural-abundance rubidium (Rb) generated from Rb azide (RbN ${}_{3}$ ) for chip-scale atomic clocks. A wafer-level fabrication method enabling individual control of N2 pressure was developed by inkjet patterning of RbN3 and subsequent krypton fluoride (KrF) excimer laser decomposition. An increasing N2 pressure was found to reduce the CPT linewidth and cause a significant decrease in the signal amplitude, which resulted in monotonic degradation in the CPT figure of merit with higher pressures. A CPT-based laser frequency stabilization method that locked the laser wavelength to the CPT resonance peak yielded significantly larger signal amplitudes than a conventional absorption-based method in the low-pressure regime below 8 kPa. These results show that CPT performance in micro-fabricated Rb vapor cells is more restricted by the signal amplitude rather than the linewidth. They also offer practical buffer-gas design guidelines for enhancing short-term frequency stability in chip-scale atomic clocks.

IEEE Open Journal of Ultrasonics Ferroelectrics and Frequency Control•Jan 1, 2026•0 citations
Characteristics of CPT (coherent population trapping) signal are investigated in small-size glass vapor cells containing 87 Rb and Ne buffer gas with narrow linewidth laser pumping on D 2 line. Parameters of CPT absorption signals are measured using small-size vapor cells with Ne buffer gas pressure in range of 200-400 Torr, cell temperature in range of 65-120 °C and values of laser pumping power of 30-400 μW/cm 2 . Optimum conditions, under which the minimal value of short-term instability of resonance line is achieved, are obtained in experiments. CPT signals using vapor cells based on integrated technologies containing 87 Rb in atmosphere of Ne are also investigated. The CPT signals with typical linewidths of 2-3 kHz and signal-to-noise ratio of 1500 in 1 Hz bandwidth are observed, which allows one to provide relative frequency instability of 10 -11 at 100 s.
The characteristics of coherent population trapping (CPT) signal were investigated in small-size glass vapor cells containing [Formula: see text]Rb and Ne buffer gas with narrow line-width laser pumping on D2 line. The parameters of CPT signals were measured using small-size vapor cells with Ne buffer gas pressure in the range of 200–400 Torr, cell temperature in the range of 65–120 [Formula: see text]C and the values of laser pumping power of 30–400 [Formula: see text]W/cm2. Optimal conditions, under which the minimal value of short-term instability of resonance line is achieved, were obtained in experiments. Orientation frequency shifts of CPT resonance using glass [Formula: see text]Rb vapor cells containing buffer gas and anti-relaxation coating were compared. CPT signals using vapor cells based on integrated technologies containing [Formula: see text]Rb in atmosphere of Ne were also investigated. The CPT signals with typical line widths of 2–3 kHz and signal-to-noise ratio of 1500 in 1 Hz bandwidth are observed, which allows one to provide relative frequency instability of 10[Formula: see text] at 100 s.
Coherent population trapping (CPT) on 87 Rb atoms in neon atmosphere has been studied in small-size glass absorption cells under conditions of pumping with narrow-band laser radiation at the D 2 line of the main doublet. Parameters of the absorption signal have been measured in 3-mm-diameter cells at buffer gas (Ne) pressures varied within 200–400 Torr, cell temperatures within 65–120°C, and pumping radiation power densities within 30–400 μW/cm 2 . Optimum values of the buffer gas pressures, cell temperature, and pumping power are determined at which the short-term instability of the resonance line is at minimum. Orientational shifts of the CPT resonance signal in gas-filled cells and small-size cells with antirelaxation coating have been compared.
Pulsed coherent population trapping (CPT) spectroscopy is applied in buffer-gas filled Cs–Ne vapor microfabricated cells. The properties of the Ramsey-CPT clock transition central fringe (linewidth, signal amplitude, and contrast) are studied versus several experimental parameters, including the Ramsey sequence and the input laser intensity, and are compared to those obtained in the conventional continuous (CW) interrogation mode. In the pulsed case and for short Ramsey-free evolution times TR, the central fringe linewidth is found to exhibit a small but visible power broadening and is measured to be narrower than the value of 1/(2TR) that is reached for long TR. The microwave hyperfine coherence lifetime T2 in the Cs–Ne microcells is measured to be in the 50–500 μs range. Its dependence to the buffer gas pressure or cell temperature is briefly studied.
Based on a Λ-type three-level system consists of cesium (Cs) 6S1/2 (Fg = 3) and 6S1/2 (Fg = 4) long-lived ground states and 6P3/2 (Fe = 4) excited state, we have experimentally measured and theoretically analyzed the characters of coherent population trapping (CPT) resonances in Cs vapor cells with different partial pressure of neon (Ne) as buffer gas around room temperature. The impact of some experimental parameters, such as the relative intensity ratio between two phase-locked laser beams, the laser intensity, with or without buffer gas and the partial pressure of Ne, the temperature and the longitudinal magnetic field, on the CPT resonance was studied in details. With the optimized parameters, we got typical CPT signal with the full-width half-maximum (FWHM) linewidth as narrow as ~ 181 Hz in a Cs vapor cell filled with 30 Torr of Ne as buffer gas.
We present a pair of phase-locked lasers with a 9.2-GHz frequency difference through the injection locking of a master laser to the RF-modulation sideband of a slave diode laser. Using this laser system, a coherent population trapping (CPT) signal with a typical linewidth of ∼ 182 Hz is obtained in a cesium vapor cell filled with 30 Torr (4 kPa) of neon as the buffer gas. We investigate the influence of the partial pressure of the neon buffer gas on the CPT linewidth, amplitude, and frequency shift. The results may offer some references for CPT atomic clocks and CPT atomic magnetometers.
Controlling buffer-gas conditions in vapor cells is essential for frequency stabilization and atomic-clock performance. This study investigated the dependence of coherent population trapping (CPT) signal characteristics on nitrogen (N 2{}_{2}2​ ) buffer-gas pressure in micro-fabricated vapor cells containing natural-abundance rubidium (Rb) generated from Rb azide (RbN 3{}_{3}3​ ) for chip-scale atomic clocks. A wafer-level fabrication method enabling individual control of N2 pressure was developed by inkjet patterning of RbN3 and subsequent krypton fluoride (KrF) excimer laser decomposition. An increasing N2 pressure was found to reduce the CPT linewidth and cause a significant decrease in the signal amplitude, which resulted in monotonic degradation in the CPT figure of merit with higher pressures. A CPT-based laser frequency stabilization method that locked the laser wavelength to the CPT resonance peak yielded significantly larger signal amplitudes than a conventional absorption-based method in the low-pressure regime below 8 kPa. These results show that CPT performance in micro-fabricated Rb vapor cells is more restricted by the signal amplitude rather than the linewidth. They also offer practical buffer-gas design guidelines for enhancing short-term frequency stability in chip-scale atomic clocks.