Chinese Physics B

Characterizing passive coherent population trapping resonance in a cesium vapor cell filled with neon buffer gas

Zhi Liu, Jieying Wang, Wen-Ting Diao, Jun He, Junmin Wang

Published Apr 1, 2013• 3 citations
Publisher

Abstract

We present a pair of phase-locked lasers with a 9.2-GHz frequency difference through the injection locking of a master laser to the RF-modulation sideband of a slave diode laser. Using this laser system, a coherent population trapping (CPT) signal with a typical linewidth of ∼ 182 Hz is obtained in a cesium vapor cell filled with 30 Torr (4 kPa) of neon as the buffer gas. We investigate the influence of the partial pressure of the neon buffer gas on the CPT linewidth, amplitude, and frequency shift. The results may offer some references for CPT atomic clocks and CPT atomic magnetometers.

DOI
10.1088/1674-1056/22/4/043201

Related papers

Passive atomic frequency standard based on coherent population trapping in ^87Rb using injection-locked lasers

Han Seb Moon, Sang Eon Park, Young‐Ho Park +2 more

We present a microwave frequency standard based on coherent population trapping (CPT) in the 87Rb D1 line. The CPT spectrum is obtained using two Raman lasers with a 6.8 GHz frequency offset by injection locking of a master laser to a slave laser. We have constructed an atomic clock employing a 5 cm long Rb vapor cell confined with 6.67 kPa neon buffer gas at 70 °C. Using this system, we improve the CPT contrast through the elimination of undesired off-resonant fields created by the direct modulation method. We measured the frequency shift of the CPT signal as a function of the temperature of the Rb cell and estimated it to be approximately 1.3 ×10−9/K. The frequency of a 10 MHz crystal oscillator has been stabilized to the CPT spectrum between the two ground states in 87Rb. The relative frequency stability is approximately 2.3×10−12 for an average time of 68 s.

Journal of the Optical Society of America B•Nov 1, 2006•23 citations

A frequency reference based in VCSEL-driven dark line resonances in Cs vapor

John E. Kitching, N. Vukičević, Alexander S. Zibrov +4 more

Summary form only given. We report on recent experiments to use dark line coherent population trapping (CPT) resonances in cesium vapor as the basis for a compact frequency reference. The resonance is excited by directly modulating the injection current of a VCSEL at one-half the ground state hyperfine transition of Cs (4.6 GHz) to produce RF sidebands on the optical carrier. The laser output is then passed through a room-temperature cell containing Cs at its vapor pressure together with 8.7 kPa of Neon buffer gas and the transmitted optical power is detected in a photodiode. When the laser carrier is tuned half way between the two hyperfine components of the D/sub 2/ line at 852 nm, and the RF modulation frequency is adjusted to be equal to one-half the hyperfine splitting, the absorption of the sidebands through the cell is slightly reduced due to the CPT effect. As the RF frequency is scanned over the resonance, lock-in detection is used to produce a /spl sim/1 kHz wide dispersive error signal which is in turn used to stabilize the modulation frequency. The narrow signal is the result of the buffer gas, which reduces the time-of-flight broadening of the transition.

Quantum Electronics and Laser Science Conference•May 7, 2000•1 citation

Optimization of the experimental parameters of cesium CPT system

Zhi Liu, Jieying Wang, Wen-Ting Diao +2 more

Based on a Λ-type three-level system consists of cesium (Cs) 6S1/2 (Fg = 3) and 6S1/2 (Fg = 4) long-lived ground states and 6P3/2 (Fe = 4) excited state, we have experimentally measured and theoretically analyzed the characters of coherent population trapping (CPT) resonances in Cs vapor cells with different partial pressure of neon (Ne) as buffer gas around room temperature. The impact of some experimental parameters, such as the relative intensity ratio between two phase-locked laser beams, the laser intensity, with or without buffer gas and the partial pressure of Ne, the temperature and the longitudinal magnetic field, on the CPT resonance was studied in details. With the optimized parameters, we got typical CPT signal with the full-width half-maximum (FWHM) linewidth as narrow as ~ 181 Hz in a Cs vapor cell filled with 30 Torr of Ne as buffer gas.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Nov 29, 2012•1 citation

Investigation of experimental parameters of coherent population trapping with cesium vapor cell

Zhi Liu, Diao Wen-Ting, Jieying Wang +5 more

According to the Λ -type three-level system consisting of cesium 6S1/2 (F=3 and F=4) long-lived ground states and 6P3/2 (F'=4) excited state, we experimentally investigate and theoretically analyze the parameters of coherent population trapping (CPT) spectra in a cesium atomic vapor cell with or without neon as buffer gas. The CPT of the full width at half maximum (FWHM), the signal amplitude as a function of optical intensity of the two phased-locked laser beams with a frequency difference of 9.19263177 GHz (the hyperfine splitting in the cesium ground state 6S1/2), relative intensity ratio, beam spot size, residual magnetic field of the magnetic shielding, and the influence of with and without the cesium vapor cell containing neon as buffer gas are investigated experimentally. With the optimized parameters, we obtain the CPT signal FWHM to be as narrow as ~ 340 Hz.

Acta Physica Sinica•Jan 1, 2012•2 citations

Buffer-gas-induced linewidth reduction of coherent dark resonances to below 50 Hz

Sebastián Brandt, A. Nagel, R. Wynands +1 more

When neon is introduced as a buffer gas the interaction time of cesium atoms in a vapor cell with resonant laser beams is drastically increased. Using a pair of phase-locked lasers we have observed linewidths as narrow as $42 $Hz for coherent dark resonances in a cesium vapor cell. We study the influence of power and pressure broadening and systematic shifts of the resonance frequency. Our experiments demonstrate that coherent dark resonances could rival direct radio-frequency precision measurements, which have a wide range of applications in physics.

Physical Review A•Aug 1, 1997•206 citations

Coherent population trapping resonances in Cs–Ne vapor microcells for miniature clocks applications

Rodolphe Boudot, P. Dziuban, Madoka Hasegawa +4 more

We report the characterization of dark line resonances observed in Cs vapor microcells filled with a unique neon (Ne) buffer gas. The impact on the coherent population trapping (CPT) resonance of some critical external parameters such as laser intensity, cell temperature, and microwave power is studied. We show the suppression of the first-order light shift by proper choice of the microwave power. The temperature dependence of the Cs ground state hyperfine resonance frequency is shown to be canceled in the 77–80 °C range for various Ne buffer gas pressures. The necessity to adjust the Ne buffer gas pressure or the cell dimensions to optimize the CPT signal height at the frequency inversion temperature is pointed out. Based on such Cs–Ne microcells, we preliminary demonstrate a 852 nm vertical cavity surface emitted laser (VCSEL)-modulated based CPT atomic clock exhibiting a short term fractional frequency instability σy(τ)=1.5×10−10τ−1/2 until 30 s. These results, similar to those published in the literature by others groups, prove the potential of our original microcell technology in view of the development of high-performance chip scale atomic clocks.

Journal of Applied Physics•Jan 1, 2011•56 citations
We present a pair of phase-locked lasers with a 9.2-GHz frequency difference through the injection locking of a master laser to the RF-modulation sideband of a slave diode laser. Using this laser system, a coherent population trapping (CPT) signal with a typical linewidth of ∼ 182 Hz is obtained in a cesium vapor cell filled with 30 Torr (4 kPa) of neon as the buffer gas. We investigate the influence of the partial pressure of the neon buffer gas on the CPT linewidth, amplitude, and frequency shift. The results may offer some references for CPT atomic clocks and CPT atomic magnetometers.
We present a microwave frequency standard based on coherent population trapping (CPT) in the 87Rb D1 line. The CPT spectrum is obtained using two Raman lasers with a 6.8 GHz frequency offset by injection locking of a master laser to a slave laser. We have constructed an atomic clock employing a 5 cm long Rb vapor cell confined with 6.67 kPa neon buffer gas at 70 °C. Using this system, we improve the CPT contrast through the elimination of undesired off-resonant fields created by the direct modulation method. We measured the frequency shift of the CPT signal as a function of the temperature of the Rb cell and estimated it to be approximately 1.3 ×10−9/K. The frequency of a 10 MHz crystal oscillator has been stabilized to the CPT spectrum between the two ground states in 87Rb. The relative frequency stability is approximately 2.3×10−12 for an average time of 68 s.
Summary form only given. We report on recent experiments to use dark line coherent population trapping (CPT) resonances in cesium vapor as the basis for a compact frequency reference. The resonance is excited by directly modulating the injection current of a VCSEL at one-half the ground state hyperfine transition of Cs (4.6 GHz) to produce RF sidebands on the optical carrier. The laser output is then passed through a room-temperature cell containing Cs at its vapor pressure together with 8.7 kPa of Neon buffer gas and the transmitted optical power is detected in a photodiode. When the laser carrier is tuned half way between the two hyperfine components of the D/sub 2/ line at 852 nm, and the RF modulation frequency is adjusted to be equal to one-half the hyperfine splitting, the absorption of the sidebands through the cell is slightly reduced due to the CPT effect. As the RF frequency is scanned over the resonance, lock-in detection is used to produce a /spl sim/1 kHz wide dispersive error signal which is in turn used to stabilize the modulation frequency. The narrow signal is the result of the buffer gas, which reduces the time-of-flight broadening of the transition.
Based on a Λ-type three-level system consists of cesium (Cs) 6S1/2 (Fg = 3) and 6S1/2 (Fg = 4) long-lived ground states and 6P3/2 (Fe = 4) excited state, we have experimentally measured and theoretically analyzed the characters of coherent population trapping (CPT) resonances in Cs vapor cells with different partial pressure of neon (Ne) as buffer gas around room temperature. The impact of some experimental parameters, such as the relative intensity ratio between two phase-locked laser beams, the laser intensity, with or without buffer gas and the partial pressure of Ne, the temperature and the longitudinal magnetic field, on the CPT resonance was studied in details. With the optimized parameters, we got typical CPT signal with the full-width half-maximum (FWHM) linewidth as narrow as ~ 181 Hz in a Cs vapor cell filled with 30 Torr of Ne as buffer gas.
According to the Λ -type three-level system consisting of cesium 6S1/2 (F=3 and F=4) long-lived ground states and 6P3/2 (F'=4) excited state, we experimentally investigate and theoretically analyze the parameters of coherent population trapping (CPT) spectra in a cesium atomic vapor cell with or without neon as buffer gas. The CPT of the full width at half maximum (FWHM), the signal amplitude as a function of optical intensity of the two phased-locked laser beams with a frequency difference of 9.19263177 GHz (the hyperfine splitting in the cesium ground state 6S1/2), relative intensity ratio, beam spot size, residual magnetic field of the magnetic shielding, and the influence of with and without the cesium vapor cell containing neon as buffer gas are investigated experimentally. With the optimized parameters, we obtain the CPT signal FWHM to be as narrow as ~ 340 Hz.
When neon is introduced as a buffer gas the interaction time of cesium atoms in a vapor cell with resonant laser beams is drastically increased. Using a pair of phase-locked lasers we have observed linewidths as narrow as $42 $Hz for coherent dark resonances in a cesium vapor cell. We study the influence of power and pressure broadening and systematic shifts of the resonance frequency. Our experiments demonstrate that coherent dark resonances could rival direct radio-frequency precision measurements, which have a wide range of applications in physics.
We report the characterization of dark line resonances observed in Cs vapor microcells filled with a unique neon (Ne) buffer gas. The impact on the coherent population trapping (CPT) resonance of some critical external parameters such as laser intensity, cell temperature, and microwave power is studied. We show the suppression of the first-order light shift by proper choice of the microwave power. The temperature dependence of the Cs ground state hyperfine resonance frequency is shown to be canceled in the 77–80 °C range for various Ne buffer gas pressures. The necessity to adjust the Ne buffer gas pressure or the cell dimensions to optimize the CPT signal height at the frequency inversion temperature is pointed out. Based on such Cs–Ne microcells, we preliminary demonstrate a 852 nm vertical cavity surface emitted laser (VCSEL)-modulated based CPT atomic clock exhibiting a short term fractional frequency instability σy(τ)=1.5×10−10τ−1/2 until 30 s. These results, similar to those published in the literature by others groups, prove the potential of our original microcell technology in view of the development of high-performance chip scale atomic clocks.