Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of the Optical Society of America B

Passive atomic frequency standard based on coherent population trapping in ^87Rb using injection-locked lasers

Han Seb Moon, Sang Eon Park, Young‐Ho Park, Lim Lee, Jung Bog Kim

Published Nov 1, 2006• 23 citations
Publisher

Abstract

We present a microwave frequency standard based on coherent population trapping (CPT) in the 87Rb D1 line. The CPT spectrum is obtained using two Raman lasers with a 6.8 GHz frequency offset by injection locking of a master laser to a slave laser. We have constructed an atomic clock employing a 5 cm long Rb vapor cell confined with 6.67 kPa neon buffer gas at 70 °C. Using this system, we improve the CPT contrast through the elimination of undesired off-resonant fields created by the direct modulation method. We measured the frequency shift of the CPT signal as a function of the temperature of the Rb cell and estimated it to be approximately 1.3 ×10−9/K. The frequency of a 10 MHz crystal oscillator has been stabilized to the CPT spectrum between the two ground states in 87Rb. The relative frequency stability is approximately 2.3×10−12 for an average time of 68 s.

DOI
10.1364/josab.23.002393

Related papers

Characterizing passive coherent population trapping resonance in a cesium vapor cell filled with neon buffer gas

Zhi Liu, Jieying Wang, Wen-Ting Diao +2 more

We present a pair of phase-locked lasers with a 9.2-GHz frequency difference through the injection locking of a master laser to the RF-modulation sideband of a slave diode laser. Using this laser system, a coherent population trapping (CPT) signal with a typical linewidth of ∼ 182 Hz is obtained in a cesium vapor cell filled with 30 Torr (4 kPa) of neon as the buffer gas. We investigate the influence of the partial pressure of the neon buffer gas on the CPT linewidth, amplitude, and frequency shift. The results may offer some references for CPT atomic clocks and CPT atomic magnetometers.

Chinese Physics B•Apr 1, 2013•3 citations

Performance of a prototype atomic clock based on lin‖lin coherent population trapping resonances in Rb atomic vapor

Eugeniy E. Mikhailov, Travis Horrom, Nathan Belcher +1 more

We report on the performance of the first table-top prototype atomic clock based on coherent population trapping (CPT) resonances with parallel linearly polarized optical fields (lin‖lin configuration). Our apparatus uses a vertical-cavity surface-emitting laser (VCSEL) tuned to the D1 line of 87Rb with the current modulation at the 87Rb hyperfine frequency. We demonstrate cancellation of the first-order light shift by the proper choice of rf modulation power and further improve our prototype clock stability by optimizing the parameters of the microwave lock loop. Operating in these optimal conditions, we measured a short-term fractional frequency stability (Allan deviation) 2×10−11τ−1/2 for observation times 1 s ≤ τ ≤ 20 s. This value is limited by large VCSEL phase noise and environmental temperature fluctuation. Further improvements in frequency stability should be possible with an apparatus designed as a dedicated lin‖lin CPT resonance clock with environmental impacts minimized.

arXiv:0910.5881•Journal of the Optical Society of America B•Feb 3, 2010•53 citations

Low power 85Rb CPT atomic clock

Shigeyoshi Goka, Okura Taisuke, Moroyama Munetake +1 more

This paper outlines the features of the85Rb vapor cell atomic clock, the coherent population trapping (CPT) resonance in an85Rb/87Rb mixed vapor cell, and the results of the frequency stabilities of a pilot system. The experiments were performed with a sealed vapor cell containing a natural mixture of Rb isotopes and a buffer gas. Excitation of the CPT resonance was accomplished using a vertical-cavity surface-emitting laser modulated at 1.5, 3.0, 3.4 and 6.8 GHz, which corresponded to the full- and half-ground-state hyperfine frequencies of85Rb and87Rb. The results show that the CPT resonances at both85Rb and87Rb can be observed separately. The frequency stabilities of the output signals for each CPT resonance were ≪ 10x10−12/day for85Rb and ≪ 6x10−12/day for87Rb. In addition, the RF modulation signal power for85Rb was 1.1 dB less than that of87Rb, which was 3.4GHz.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 1, 2008•2 citations

Atomic Frequency Standard based on Coherent Population Trapping in Rb-87 Atoms for Space Application

Pragya Tiwari, Manjula Ramachandra, Madan Mohan Kandpal +11 more

Space-borne atomic frequency standards demand a high level of performance and stability throughout the mission life in the harsh environment of space. Recently, atomic clocks employing Coherent Population Trapping (CPT), a quantum interference phenomenon in alkali atoms, have shown much promise for space application. This paper presents the development and realization of compact and reliable CPT atomic clock for ISRO's navigational satellites. In our approach, quantum interference in Rb-87 atoms are pursued for obtaining the clock resonance, owing to their larger ground state hyperfine transition energy (higher Q-factor). Quantum interference is realized by generating two resonant optical laser fields from a VCSEL diode by modulating its drive current at RF frequency which corresponds to the ground state hyperfine separation in Rb-87 atoms. The emission frequency of the laser diode is stabilized by locking it with respect to the D1 hyperfine transition with the help of a servo control loop, thereby the instabilities associated with laser frequency fluctuations are minimized. The resulting CPT resonance (<;kHz) as shown in Figure 1 is used as reference to stabilize the crystal oscillator frequency (10 MHz) that serves both as clock output and seed for generating the RF field.

URSI Asia-Pacific Radio Science Conference•Mar 1, 2019•0 citations

85Rb D1-Line Coherent-Population-Trapping Atomic Clock for Low-Power Operation

Shigeyoshi Goka

A 85Rb D1-line coherent-population-trapping (CPT) atomic clock with a natural-mixture Rb gas cell is demonstrated. D1-line excitation can generate a larger CPT resonance amplitude, and the choice of 85Rb rather than conventional 87Rb is because of its lower ground-state hyperfine-splitting frequency. The frequency deviation for the D1 line was measured using the same experimental setup as that for the D2 line except for the vertical-cavity surface-emitting laser (VCSEL) wavelength and RF power. In the case of D1-line excitation, the CPT resonance amplitude was 1.5 times that for the D2 line, and the light shift sensitivity was one-half that for the D2 line. The Allan standard deviations for the 85Rb D1 line, estimated from the frequency deviations, are <2.5×10-12 per day. In addition, the required RF is 1.5 GHz and its power is only -8.0 dBm.

Japanese Journal of Applied Physics•Jun 1, 2010•7 citations

Properties of Rb CPT Atomic Clock at Subharmonic Microwave Modulation Frequencies

Daba A. Radnatarov, Sergey M Kobtsev, Valeriy Andryushkov +3 more

This letter presents for the first time a systematic study of an atomic frequency standard based on coherent population trapping (CPT) effect in87Rb vapour optically pumped with a multifrequency laser radiation formed with sidebands of a single-frequency laser whose injection current is modulated at a subharmonic frequency (1/2-1/6) relative to the frequency of hyperfine ground state splitting. Measured are the CPT resonance parameters and the atomic clock short-term stability at different subharmonic frequencies of microwave modulation. The possibility of CPT resonance light shift suppression is experimentally demonstrated at modulation frequencies between 1/3 and 1/5 of the resonant frequency for continuous wave optical pumping of the87Rb vapour D1 line. Analyzed are the capabilities and potential of reduced energy consumption of atomic clocks when CPT resonance in rubidium vapour is excited at subharmonic modulation frequencies.

IEEE photonics journal•Jun 26, 2019•2 citations
We present a microwave frequency standard based on coherent population trapping (CPT) in the 87Rb D1 line. The CPT spectrum is obtained using two Raman lasers with a 6.8 GHz frequency offset by injection locking of a master laser to a slave laser. We have constructed an atomic clock employing a 5 cm long Rb vapor cell confined with 6.67 kPa neon buffer gas at 70 °C. Using this system, we improve the CPT contrast through the elimination of undesired off-resonant fields created by the direct modulation method. We measured the frequency shift of the CPT signal as a function of the temperature of the Rb cell and estimated it to be approximately 1.3 ×10−9/K. The frequency of a 10 MHz crystal oscillator has been stabilized to the CPT spectrum between the two ground states in 87Rb. The relative frequency stability is approximately 2.3×10−12 for an average time of 68 s.
We present a pair of phase-locked lasers with a 9.2-GHz frequency difference through the injection locking of a master laser to the RF-modulation sideband of a slave diode laser. Using this laser system, a coherent population trapping (CPT) signal with a typical linewidth of ∼ 182 Hz is obtained in a cesium vapor cell filled with 30 Torr (4 kPa) of neon as the buffer gas. We investigate the influence of the partial pressure of the neon buffer gas on the CPT linewidth, amplitude, and frequency shift. The results may offer some references for CPT atomic clocks and CPT atomic magnetometers.
We report on the performance of the first table-top prototype atomic clock based on coherent population trapping (CPT) resonances with parallel linearly polarized optical fields (lin‖lin configuration). Our apparatus uses a vertical-cavity surface-emitting laser (VCSEL) tuned to the D1 line of 87Rb with the current modulation at the 87Rb hyperfine frequency. We demonstrate cancellation of the first-order light shift by the proper choice of rf modulation power and further improve our prototype clock stability by optimizing the parameters of the microwave lock loop. Operating in these optimal conditions, we measured a short-term fractional frequency stability (Allan deviation) 2×10−11τ−1/2 for observation times 1 s ≤ τ ≤ 20 s. This value is limited by large VCSEL phase noise and environmental temperature fluctuation. Further improvements in frequency stability should be possible with an apparatus designed as a dedicated lin‖lin CPT resonance clock with environmental impacts minimized.
This paper outlines the features of the85Rb vapor cell atomic clock, the coherent population trapping (CPT) resonance in an85Rb/87Rb mixed vapor cell, and the results of the frequency stabilities of a pilot system. The experiments were performed with a sealed vapor cell containing a natural mixture of Rb isotopes and a buffer gas. Excitation of the CPT resonance was accomplished using a vertical-cavity surface-emitting laser modulated at 1.5, 3.0, 3.4 and 6.8 GHz, which corresponded to the full- and half-ground-state hyperfine frequencies of85Rb and87Rb. The results show that the CPT resonances at both85Rb and87Rb can be observed separately. The frequency stabilities of the output signals for each CPT resonance were ≪ 10x10−12/day for85Rb and ≪ 6x10−12/day for87Rb. In addition, the RF modulation signal power for85Rb was 1.1 dB less than that of87Rb, which was 3.4GHz.
Space-borne atomic frequency standards demand a high level of performance and stability throughout the mission life in the harsh environment of space. Recently, atomic clocks employing Coherent Population Trapping (CPT), a quantum interference phenomenon in alkali atoms, have shown much promise for space application. This paper presents the development and realization of compact and reliable CPT atomic clock for ISRO's navigational satellites. In our approach, quantum interference in Rb-87 atoms are pursued for obtaining the clock resonance, owing to their larger ground state hyperfine transition energy (higher Q-factor). Quantum interference is realized by generating two resonant optical laser fields from a VCSEL diode by modulating its drive current at RF frequency which corresponds to the ground state hyperfine separation in Rb-87 atoms. The emission frequency of the laser diode is stabilized by locking it with respect to the D1 hyperfine transition with the help of a servo control loop, thereby the instabilities associated with laser frequency fluctuations are minimized. The resulting CPT resonance (<;kHz) as shown in Figure 1 is used as reference to stabilize the crystal oscillator frequency (10 MHz) that serves both as clock output and seed for generating the RF field.
A 85Rb D1-line coherent-population-trapping (CPT) atomic clock with a natural-mixture Rb gas cell is demonstrated. D1-line excitation can generate a larger CPT resonance amplitude, and the choice of 85Rb rather than conventional 87Rb is because of its lower ground-state hyperfine-splitting frequency. The frequency deviation for the D1 line was measured using the same experimental setup as that for the D2 line except for the vertical-cavity surface-emitting laser (VCSEL) wavelength and RF power. In the case of D1-line excitation, the CPT resonance amplitude was 1.5 times that for the D2 line, and the light shift sensitivity was one-half that for the D2 line. The Allan standard deviations for the 85Rb D1 line, estimated from the frequency deviations, are <2.5×10-12 per day. In addition, the required RF is 1.5 GHz and its power is only -8.0 dBm.
This letter presents for the first time a systematic study of an atomic frequency standard based on coherent population trapping (CPT) effect in87Rb vapour optically pumped with a multifrequency laser radiation formed with sidebands of a single-frequency laser whose injection current is modulated at a subharmonic frequency (1/2-1/6) relative to the frequency of hyperfine ground state splitting. Measured are the CPT resonance parameters and the atomic clock short-term stability at different subharmonic frequencies of microwave modulation. The possibility of CPT resonance light shift suppression is experimentally demonstrated at modulation frequencies between 1/3 and 1/5 of the resonant frequency for continuous wave optical pumping of the87Rb vapour D1 line. Analyzed are the capabilities and potential of reduced energy consumption of atomic clocks when CPT resonance in rubidium vapour is excited at subharmonic modulation frequencies.