Journal of Applied Physics

Coherent population trapping resonances in Cs–Ne vapor microcells for miniature clocks applications

Rodolphe Boudot, P. Dziuban, Madoka Hasegawa, Ravinder Chutani, Serge Galliou, V. Giordano, Christophe Gorecki

Published Jan 1, 2011• 56 citations
Publisher

Abstract

We report the characterization of dark line resonances observed in Cs vapor microcells filled with a unique neon (Ne) buffer gas. The impact on the coherent population trapping (CPT) resonance of some critical external parameters such as laser intensity, cell temperature, and microwave power is studied. We show the suppression of the first-order light shift by proper choice of the microwave power. The temperature dependence of the Cs ground state hyperfine resonance frequency is shown to be canceled in the 77–80 °C range for various Ne buffer gas pressures. The necessity to adjust the Ne buffer gas pressure or the cell dimensions to optimize the CPT signal height at the frequency inversion temperature is pointed out. Based on such Cs–Ne microcells, we preliminary demonstrate a 852 nm vertical cavity surface emitted laser (VCSEL)-modulated based CPT atomic clock exhibiting a short term fractional frequency instability σy(τ)=1.5×10−10τ−1/2 until 30 s. These results, similar to those published in the literature by others groups, prove the potential of our original microcell technology in view of the development of high-performance chip scale atomic clocks.

DOI
10.1063/1.3530951

Related papers

Dark line resonances in Cs-Ne vapor microcells for chip scale atomic clocks

Rodolphe Boudot, P. Dziuban, Xiaochi Liu +5 more

We report the characterization of Coherent Population Trapping (CPT) resonances in Cs vapor microcells filled with Neon (Ne) buffer gas. The impact on the atomic hyperfine resonance of some external parameters such as laser intensity and cell temperature is studied. We show the suppression of the first-order light shift by proper choice of the microwave power. The temperature dependence of the Cs ground state hyperfine resonance frequency is shown to be canceled in the 77-80°C range for various Ne buffer gas pressures. We preliminary demonstrate a 852 nm VCSEL-modulated based CPT atomic clock exhibiting a short term fractional frequency instability σy(τ) = 1.5×10-10τ-1/2until 200 s.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 1, 2011•0 citations

Cs vapor microcells with Ne-He buffer gas mixture for high operation-temperature miniature atomic clocks

Eric Kroemer, Moustafa Abdel Hafiz, Vincent N. Maurice +3 more

We report on the characterization of Cs vapor microfabricated cells filled with a Ne-He buffer gas mixture using coherent population trapping (CPT) spectroscopy. The temperature dependence of the Cs clock frequency is found to be canceled at the first order around a so-called inversion temperature higher than 80°C whose value depends on the buffer gas partial pressure ratio. This buffer gas mixture could be well-adapted for the development of miniature atomic clocks devoted to be used in specific applications such as defense and avionic systems with high operating temperature environment (typically higher than 85°C). This solution suggests an alternative to buffer gas mixtures generally used in optically-pumped vapor cell atomic clocks.

Optics Express•Jul 7, 2015•16 citations

Pulsed coherent population trapping spectroscopy in microfabricated Cs–Ne vapor cells

Rodolphe Boudot, Vincent N. Maurice, Christophe Gorecki +1 more

Pulsed coherent population trapping (CPT) spectroscopy is applied in buffer-gas filled Cs–Ne vapor microfabricated cells. The properties of the Ramsey-CPT clock transition central fringe (linewidth, signal amplitude, and contrast) are studied versus several experimental parameters, including the Ramsey sequence and the input laser intensity, and are compared to those obtained in the conventional continuous (CW) interrogation mode. In the pulsed case and for short Ramsey-free evolution times TR, the central fringe linewidth is found to exhibit a small but visible power broadening and is measured to be narrower than the value of 1/(2TR) that is reached for long TR. The microwave hyperfine coherence lifetime T2 in the Cs–Ne microcells is measured to be in the 50–500 μs range. Its dependence to the buffer gas pressure or cell temperature is briefly studied.

Journal of the Optical Society of America B•Apr 4, 2018•11 citations

First-order cancellation of the Cs clock frequency temperature-dependence in Ne-Ar buffer gas mixture

Rodolphe Boudot, D. Miletic, P. Dziuban +6 more

Through the detection of Coherent Population Trapping (CPT) resonances, we demonstrate the temperature-dependence cancellation of the Cs clock frequency in microfabricated vapor cells filled with a mixture of Ne and Ar. The inversion temperature at which the Cs clock frequency temperature sensitivity is greatly reduced only depends on the partial pressure of buffer gases and is measured to be lower than 80°C as expected with simple theoretical calculations. These results are important for the development of state-of-the-art Cs vapor cell clocks with improved long-term frequency stability.

Optics Express•Feb 2, 2011•16 citations

A frequency reference based in VCSEL-driven dark line resonances in Cs vapor

John E. Kitching, N. Vukičević, Alexander S. Zibrov +4 more

Summary form only given. We report on recent experiments to use dark line coherent population trapping (CPT) resonances in cesium vapor as the basis for a compact frequency reference. The resonance is excited by directly modulating the injection current of a VCSEL at one-half the ground state hyperfine transition of Cs (4.6 GHz) to produce RF sidebands on the optical carrier. The laser output is then passed through a room-temperature cell containing Cs at its vapor pressure together with 8.7 kPa of Neon buffer gas and the transmitted optical power is detected in a photodiode. When the laser carrier is tuned half way between the two hyperfine components of the D/sub 2/ line at 852 nm, and the RF modulation frequency is adjusted to be equal to one-half the hyperfine splitting, the absorption of the sidebands through the cell is slightly reduced due to the CPT effect. As the RF frequency is scanned over the resonance, lock-in detection is used to produce a /spl sim/1 kHz wide dispersive error signal which is in turn used to stabilize the modulation frequency. The narrow signal is the result of the buffer gas, which reduces the time-of-flight broadening of the transition.

Quantum Electronics and Laser Science Conference•May 7, 2000•1 citation

Characterization of coherent population-trapping resonances as atomic frequency references

Svenja A. Knappe, R. Wynands, John E. Kitching +2 more

A low-cost, potentially compact and robust microwave frequency reference can be constructed by use of vertical-cavity surface-emitting lasers and coherent population-trapping resonances in Cs vapor cells. Fractional frequency instabilities of 2×10-11/τ/s have been achieved with a minimum of 7×10-13 at τ=1000 s. The performance of this device as a function of external parameters such as light intensity, optical detuning, and cell temperature is discussed. The dependence of the dark-line resonance signal on these parameters can be understood largely by means of a simple, three-level model. The short-term stability depends critically on the optical detuning, whereas the long-term stability is limited currently by line shifts due to drifts in cell temperature.

Journal of the Optical Society of America B•Nov 1, 2001•144 citations
We report the characterization of dark line resonances observed in Cs vapor microcells filled with a unique neon (Ne) buffer gas. The impact on the coherent population trapping (CPT) resonance of some critical external parameters such as laser intensity, cell temperature, and microwave power is studied. We show the suppression of the first-order light shift by proper choice of the microwave power. The temperature dependence of the Cs ground state hyperfine resonance frequency is shown to be canceled in the 77–80 °C range for various Ne buffer gas pressures. The necessity to adjust the Ne buffer gas pressure or the cell dimensions to optimize the CPT signal height at the frequency inversion temperature is pointed out. Based on such Cs–Ne microcells, we preliminary demonstrate a 852 nm vertical cavity surface emitted laser (VCSEL)-modulated based CPT atomic clock exhibiting a short term fractional frequency instability σy(τ)=1.5×10−10τ−1/2 until 30 s. These results, similar to those published in the literature by others groups, prove the potential of our original microcell technology in view of the development of high-performance chip scale atomic clocks.
We report the characterization of Coherent Population Trapping (CPT) resonances in Cs vapor microcells filled with Neon (Ne) buffer gas. The impact on the atomic hyperfine resonance of some external parameters such as laser intensity and cell temperature is studied. We show the suppression of the first-order light shift by proper choice of the microwave power. The temperature dependence of the Cs ground state hyperfine resonance frequency is shown to be canceled in the 77-80°C range for various Ne buffer gas pressures. We preliminary demonstrate a 852 nm VCSEL-modulated based CPT atomic clock exhibiting a short term fractional frequency instability σy(τ) = 1.5×10-10τ-1/2until 200 s.
We report on the characterization of Cs vapor microfabricated cells filled with a Ne-He buffer gas mixture using coherent population trapping (CPT) spectroscopy. The temperature dependence of the Cs clock frequency is found to be canceled at the first order around a so-called inversion temperature higher than 80°C whose value depends on the buffer gas partial pressure ratio. This buffer gas mixture could be well-adapted for the development of miniature atomic clocks devoted to be used in specific applications such as defense and avionic systems with high operating temperature environment (typically higher than 85°C). This solution suggests an alternative to buffer gas mixtures generally used in optically-pumped vapor cell atomic clocks.
Pulsed coherent population trapping (CPT) spectroscopy is applied in buffer-gas filled Cs–Ne vapor microfabricated cells. The properties of the Ramsey-CPT clock transition central fringe (linewidth, signal amplitude, and contrast) are studied versus several experimental parameters, including the Ramsey sequence and the input laser intensity, and are compared to those obtained in the conventional continuous (CW) interrogation mode. In the pulsed case and for short Ramsey-free evolution times TR, the central fringe linewidth is found to exhibit a small but visible power broadening and is measured to be narrower than the value of 1/(2TR) that is reached for long TR. The microwave hyperfine coherence lifetime T2 in the Cs–Ne microcells is measured to be in the 50–500 μs range. Its dependence to the buffer gas pressure or cell temperature is briefly studied.
Through the detection of Coherent Population Trapping (CPT) resonances, we demonstrate the temperature-dependence cancellation of the Cs clock frequency in microfabricated vapor cells filled with a mixture of Ne and Ar. The inversion temperature at which the Cs clock frequency temperature sensitivity is greatly reduced only depends on the partial pressure of buffer gases and is measured to be lower than 80°C as expected with simple theoretical calculations. These results are important for the development of state-of-the-art Cs vapor cell clocks with improved long-term frequency stability.
Summary form only given. We report on recent experiments to use dark line coherent population trapping (CPT) resonances in cesium vapor as the basis for a compact frequency reference. The resonance is excited by directly modulating the injection current of a VCSEL at one-half the ground state hyperfine transition of Cs (4.6 GHz) to produce RF sidebands on the optical carrier. The laser output is then passed through a room-temperature cell containing Cs at its vapor pressure together with 8.7 kPa of Neon buffer gas and the transmitted optical power is detected in a photodiode. When the laser carrier is tuned half way between the two hyperfine components of the D/sub 2/ line at 852 nm, and the RF modulation frequency is adjusted to be equal to one-half the hyperfine splitting, the absorption of the sidebands through the cell is slightly reduced due to the CPT effect. As the RF frequency is scanned over the resonance, lock-in detection is used to produce a /spl sim/1 kHz wide dispersive error signal which is in turn used to stabilize the modulation frequency. The narrow signal is the result of the buffer gas, which reduces the time-of-flight broadening of the transition.
A low-cost, potentially compact and robust microwave frequency reference can be constructed by use of vertical-cavity surface-emitting lasers and coherent population-trapping resonances in Cs vapor cells. Fractional frequency instabilities of 2×10-11/τ/s have been achieved with a minimum of 7×10-13 at τ=1000 s. The performance of this device as a function of external parameters such as light intensity, optical detuning, and cell temperature is discussed. The dependence of the dark-line resonance signal on these parameters can be understood largely by means of a simple, three-level model. The short-term stability depends critically on the optical detuning, whereas the long-term stability is limited currently by line shifts due to drifts in cell temperature.