We demonstrate that stimulated microwave optical sideband generation using parametric frequency conversion can be utilized as a powerful technique for coherent state detection in atomic physics experiments. The technique has advantages over traditional absorption or polarization rotation-based measurements and enables the isolation of signal photons from probe photons. We outline a theoretical framework that accurately models sideband generation using a density matrix formalism. Using this technique, we demonstrate a novel intrinsic magnetic gradiometer that detects magnetic gradient fields between two spatially separated vapor cells by measuring the frequency of the beat note between sidebands generated within each cell. The sidebands are produced with high efficiency using parametric frequency conversion of a probe beam interacting with ^{87}Rb atoms in a coherent superposition of magnetically sensitive hyperfine ground states. Interference between the sidebands generates a low-frequency beat note whose frequency is determined by the magnetic field gradient between the two vapor cells. In contrast to traditional gradiometers the intermediate step of measuring the magnetic field experienced by the two vapor cells is unnecessary. We show that this technique can be readily implemented in a practical device by demonstrating a compact magnetic gradiometer sensor head with a sensitivity of 25 fT/cm/sqrt[Hz] with a 4.4 cm baseline, while operating in a noisy laboratory environment unshielded from Earth's field.
We demonstrate that stimulated microwave optical sideband generation using parametric frequency conversion can be utilized as a powerful technique for coherent state detection in atomic physics experiments. The technique has advantages over traditional absorption or polarization rotation-based measurements and enables the isolation of signal photons from probe photons. We outline a theoretical framework that accurately models sideband generation using a density matrix formalism. Using this technique, we demonstrate a novel intrinsic magnetic gradiometer that detects magnetic gradient fields between two spatially separated vapor cells by measuring the frequency of the beat note between sidebands generated within each cell. The sidebands are produced with high efficiency using parametric frequency conversion of a probe beam interacting with ^{87}Rb atoms in a coherent superposition of magnetically sensitive hyperfine ground states. Interference between the sidebands generates a low-frequency beat note whose frequency is determined by the magnetic field gradient between the two vapor cells. In contrast to traditional gradiometers the intermediate step of measuring the magnetic field experienced by the two vapor cells is unnecessary. We show that this technique can be readily implemented in a practical device by demonstrating a compact magnetic gradiometer sensor head with a sensitivity of 25 fT/cm/sqrt[Hz] with a 4.4 cm baseline, while operating in a noisy laboratory environment unshielded from Earth's field.
We describe a novel pulsed magnetic gradiometer based on the optical interference of sidebands generated using two spatially separated alkali vapor cells. The sidebands are produced with high efficiency using parametric frequency conversion of a probe beam interacting with 87Rb atoms in a coherent superposition of magnetically sensitive hyperfine ground states. Interference between the sidebands generates a low-frequency beat note whose frequency is determined by the magnetic field gradient between the two vapor cells. In contrast to traditional magnetic gradiometers, our approach provides a direct readout of the gradient field without the intermediate step of subtracting the outputs of two spacially separated magnetometers. The technique is expected to provide effective common-mode magnetic field cancellation at frequencies far greater than the bandwidth of the gradiometer. Using this technique, we developed a compact magnetic gradiometer sensor head with integrated optics with a sensitivity of 25fT/cm/Hz with a 4.4 cm baseline, while operating in a noisy laboratory environment unshielded from Earth's field. We also outline a theoretical framework that accurately models sideband generation using a density matrix formalism.
This paper demonstrates direct detection of weak signals at microwave frequencies based on parametric frequency conversion. The atomic medium is optically pumped by a resonant light field and prepared in a coherent atomic superposition by a weak microwave field. The coherent atomic superposition causes a parametric modulation of the polarization of a probe light field at the microwave field frequency. An upper limit magnetic field component sensitivity of 1.2(1.0) pT/Hz1/2, corresponding to 3.7(3.1)-μV/cm/Hz1/2electric field component sensitivity, is achieved at ~6.835 GHz with a 33-mm3vapor cell.
Quantum optical sensing is a maturing field that offers the capability to achieve extraor- dinary sensitivity. Atomic magnetometers, for example, now have the capability to detect brain signals and to precisely measure Earth’s gravity field. In optical atomic magnetome- ters, the electronic spins of the atoms in vapor form are aligned in the same direction by “pumping” the ensemble using laser light at a select frequency. Any magnetic field alters the spin states, which changes the optical properties of the vapor, such as the transmission of the laser light, providing a way to measure magnetic fields. After reviewing the theory of atomic structure and atom-light interactions relevant to the research presented here, I describe in the first part of this thesis a vector magnetometry method using microwave-assisted optical pumping, in which a microwave field resonant to the ground state hyperfine splitting of 87Rb pumps an ensemble of warm rubidium vapor, in addition to a strong optical pump beam, and a weaker optical probe beam. I present theoretical details as well as preliminary data demonstrating magnetic field measurements of a DC magnetic field. The measurements were taken when the DC field was aligned at various angles relative to the microwave magnetic field alignment. I compare theoretical and experimental differences in the measurements. With new methods for quantum devices comes the need for portability. In the second part of this thesis, we demonstrate the fabrication of millimeter-sized rubidium vapor cells using silicon micro-machining techniques. This method is relatively inexpensive compared to glass-blowing methods and allows rapid, large-scale production. I describe our process flow and demonstrate the presence of rubidium atoms inside our vapor cells. To conclude, suggestions for improvement are discussed.
Atoms form the basis of precise measurement for many quantities (time, acceleration, rotation, magnetic field, etc.). Measurements of microwave frequency electric fields by traditional methods (i.e. engineered antennas) have limited sensitivity and can be difficult to calibrate properly. Highly-excited (Rydberg) neutral atoms have very large electric-dipole moments and many dipole allowed transitions in the range of 1 - 500 GHz. It is possible to sensitively probe the electric field in this range using the combination of two quantum interference phenomena: electromagnetically induced transparency and the Autler-Townes effect. This technique allows for very sensitive field amplitude, polarization, and sub-wavelength imaging measurements. These quantities can be extracted by measuring properties of a probe laser beam as it passes through a warm rubidium vapor cell. Thus far, Rydberg microwave electrometry has relied upon the absorption of the probe laser. We report on our use of polarization rotation, which corresponds to the real part of the susceptibility, for measuring the properties of microwave frequency electric fields. Our simulations show that when a magnetic field is present and directed along the optical propagation direction a polarization rotation signal exists and can be used for microwave electrometry. One central advantage in using the polarization rotation signal rather than the absorption signal is that common mode laser noise is naturally eliminated leading to a potentially dramatic increase in signal-to-noise ratio.
By implementing a parametric down-conversion process with a strong signal field injection, we demonstrate that frequency down-conversion from pump photons to idler photons can be a coherent process. Contrary to a common misconception, we show that the process can be free of quantum noise. With an interference experiment, we demonstrate that coherence is preserved in the conversion process. This technique could lead to a high-fidelity quantum state transfer from a high-frequency photon to a low-frequency photon and connect a missing link in quantum networks. Coherent and efficient nonlinear interaction and frequency conversion are of great interest in many areas of quantum optics. Traditionally, the low efficiency of Raman scattering is improved by a high-finesse optical resonator or stimulated Raman conversion. It was recently found that the atomic spin wave initially built through electromagnetically induced transparency or a weak Raman process can actively enhance the Raman frequency conversion. An experimental demonstration of an efficient Raman conversion scheme with coherent feedback of both pump and Stokes fields is presented. The temporal profile of the generated Raman pulse shows that the coherence time of the atomic spin wave is $\sim$1.8 ms. A laser-like power threshold is observed and its low threshold is attributed to the long coherence time of the atomic spin wave. The mechanism of the conversion enhancement process is discussed and the conversion efficiency of a single pass of the beams is compared with that of double passes. Finally, a beat signal is observed between the two Stokes fields and its Fourier transform shows that the frequency difference is caused by the AC Stark effect. Precision phase measurement is traditionally restricted by the standard quantum limit. However, this limit is not as fundamental as the Heisenberg limit and can be circumvented by use of nonclassical quantum states and structure modification of the interferometers. Several examples of nonlinear interferometers are proposed and implemented. The wave propagation equations for the nonlinear interferometers are solved. The interference fringes are measured and compared with that of linear interferometers. The first nonlinear interferometer presented is based on second harmonic generation and degenerate parametric down-conversion. The second nonlinear interferometer is composed of two parametric amplifiers. The idea of nonlinear beam splitters is introduced as an analogy to traditional beam splitters. We show that a nonlinear interferometer can be built alternatively by using only one parametric amplifier. Type II phase-matched crystals can be used to increase the amplification factor. An interferometer based on a Raman amplifier is analyzed for its application to sensitive magnetic field measurement.
A new design of compact zero-field atomic gradiometer was proposed and integrated using alkali vapor cell and customized optical components. This gradiometer used two parallel elliptically polarized lights, whose output intensity was measured to perform gradient magnetic field detection, respectively. To improve the gradiometer’s sensitivity of the magnetic field detection, the gradiometer was operated in the spin-exchange relaxation-free (SERF) regime. For the sensitivity study, the gradiometer was placed in a person-sized four-layer μ-metal magnetic shielding. With the magnetic shield closed up, the sensitivity of each channel was near 34 fT/ √ Hz, and the corresponding gradient sensitivity could reach 14 fT/√ Hz/cm on a 1cm baseline. When the cover of magnetic shielding was removed, the magnetometer sensitivity of single channel was about 90 fT/√ Hz, and the corresponding gradient sensitivity could reach 34 fT/√ Hz/cm. The experimental results implied that in a poor magnetic shielding environment, the performance of magnetometer was limited due to the fluctuations of the environmental magnetic field, while the gradiometer could work well.