Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Optics and Photonics China (AOPC): Optoelectronics and Nanophotonics

A zero-field atomic gradiometer with elliptically polarized laser-pumped used for biomagnetic measurement

Kaifeng Yin, Jing Wang, Zhi Liu, Yeguang Yan, Huining Shang, Binquan Zhou

Published Nov 5, 2020• 2 citations
Publisher

Abstract

A new design of compact zero-field atomic gradiometer was proposed and integrated using alkali vapor cell and customized optical components. This gradiometer used two parallel elliptically polarized lights, whose output intensity was measured to perform gradient magnetic field detection, respectively. To improve the gradiometer’s sensitivity of the magnetic field detection, the gradiometer was operated in the spin-exchange relaxation-free (SERF) regime. For the sensitivity study, the gradiometer was placed in a person-sized four-layer μ-metal magnetic shielding. With the magnetic shield closed up, the sensitivity of each channel was near 34 fT/ √ Hz, and the corresponding gradient sensitivity could reach 14 fT/√ Hz/cm on a 1cm baseline. When the cover of magnetic shielding was removed, the magnetometer sensitivity of single channel was about 90 fT/√ Hz, and the corresponding gradient sensitivity could reach 34 fT/√ Hz/cm. The experimental results implied that in a poor magnetic shielding environment, the performance of magnetometer was limited due to the fluctuations of the environmental magnetic field, while the gradiometer could work well.

DOI
10.1117/12.2579712

Related papers

Spin-exchange relaxation-free magnetometry using elliptically polarized light

Vishal Shah, Michael V. Romalis

Spin-exchange relaxation free alkali-metal magnetometers typically operate in the regime of high optical density, presenting challenges for simple and efficient optical pumping and detection. We describe a high-sensitivity Rb magnetometer using a single elliptically polarized off-resonant laser beam. Circular component of the light creates relatively uniform spin polarization while the linear component is used to measure optical rotation generated by the atoms. Modulation of the atomic spin direction with an oscillating magnetic field shifts the detected signal to high frequencies. Using a fiber-coupled distributed feedback laser, we achieve magnetic field sensitivity of $7\text{ }\text{fT}/\sqrt{\text{Hz}}$ with a miniature $5\ifmmode\times\else\texttimes\fi{}5\ifmmode\times\else\texttimes\fi{}5\text{ }\text{mm}\text{ }\text{Rb}$ vapor cell.

arXiv:0903.2447•Physical Review A•Jul 24, 2009•273 citations

High-sensitivity closed-loop three-axis atomic magnetometer using two elliptically polarized laser beams

Yeguang Yan, Jixi Lu, Kun Wang +5 more

The high-sensitivity three-axis detection of magnetic fields is widely used in various applications.Our study demonstrates an atomic magnetometer detecting vector magnetic field, of which the core components are one glass cell and two elliptically polarized laser beams.The light-intensity noise is suppressed by differential detection technology, so a higher sensitivity is obtained compared with our previous work.The three-axis average sensitivities of the atomic magnetometer simultaneously reached 14 fT/Hz 1/2 along the x axis, 11 fT/Hz 1/2 along the y axis, and 25 fT/Hz 1/2 along the z axis.Furthermore, the atomic magnetometer's dynamic range was further improved to 150 nT, and its bandwidth was increased to over 200 Hz using a closed-loop control system.The proposed three-axis atomic magnetometer with a large dynamic range and a wide bandwidth holds great promise for biomagnetic measurement in a more challenging environment.

Chinese Optics Letters•Jan 1, 2024•1 citation

A microfabricated optically-pumped magnetic gradiometer

D. Sheng, Abigail R. Perry, Sean Krzyzewski +3 more

We report on the development of a microfabricated atomic magnetic gradiometer based on optical spectroscopy of alkali atoms in the vapor phase. The gradiometer, which operates in the spin-exchange relaxation free regime, has a length of 60 mm and cross sectional diameter of 12 mm, and consists of two chip-scale atomic magnetometers which are interrogated by a common laser light. The sensor can measure differences in magnetic fields, over a 20 mm baseline, of 10 fT/[Formula: see text] at frequencies above 20 Hz. The maximum rejection of magnetic field noise is 1000 at 10 Hz. By use of a set of compensation coils wrapped around the sensor, we also measure the sensor sensitivity at several external bias field strengths up to 150 mG. This device is useful for applications that require both sensitive gradient field information and high common-mode noise cancellation.

arXiv:1701.03236•Applied Physics Letters•Jan 16, 2017•179 citations

Atomic magnetometry based on the ground-state Hanle effect in an elliptically polarized light wave

D. V. Brazhnikov, A. O. Makarov, K. S. Kozlova +1 more

We investigate the ground-state Hanle effect in alkali-metal vapor irradiating by a resonant elliptically polarized light wave. The magneto-optical resonances are observed as a change in the ellipticity parameter of the light wave polarization when scanning the transverse magnetic field near zero. We use a miniature ($\approx\,$$0.125$ cm$^3$) glass cesium vapor cell heated to a relatively low temperature of $\approx\,$$85^\circ$C. Under the current experimental conditions, the sensitivity of magnetic field measurements is limited by a technical noise, reaching $180$ fT/$\surd$Hz in a $200$ Hz bandwidth. The ultimate photon-shot-noise-limited sensitivity of the method is estimated to be $\approx\,$$5$ fT/$\surd$Hz. The proposed scheme is promising for the development of a zero-field atomic magnetometer with reduced heat dissipation of the sensor head and relaxed requirements for magnetic shielding compared to counterparts operating in the spin-exchange relaxation-free regime. These features are of particular value for biomedical applications.

physics.atom-phCross-listedarXiv:2511.18710•The European Physical Journal D•Nov 25, 2025•0 citations

High-sensitivity operation of a single-beam atomic magnetometer for three-axis magnetic field measurement

Junjian Tang, Yueyang Zhai, Cao Li +6 more

We demonstrate a single-beam atomic magnetometer (AM) capable of measuring a three-axis magnetic field with high-sensitivity, achieved by applying a small DC offset field and a high frequency modulation field. To satisfy the miniaturization demand of AMs, an elliptically polarized light detuned by 50 GHz from the resonance transition center is employed. The circularly polarized component is used to polarize the alkali-metal atoms, while the linearly polarized light is used to detect the dynamics of the polarized spin under a magnetic field. Based on theoretical analysis, parameters that significantly affect the performance are optimized, and a sensitivity of 20 fT/Hz 1/2 in x -axis, 25 fT/Hz 1/2 in y -axis, 30 fT/Hz 1/2 in z -axis is achieved with a miniature 4 × 4 × 4 mm 87 Rb vapor cell. Moreover, we also verify that the operation principle of AMs can be used to null background magnetic fields in-situ with isotropic compensation resolution of 6.7 pT, which provides an effectively precise method for zeroing ambient magnetic field. The high-sensitivity operating of an elliptically-polarized-laser-based magnetometer provides prospective futures for constructing a compact, low-cost AM, which is particularly applicable for non-invasive bio-magnetic imaging such as array-based magnetoencephalography (MEG) and magnetocardiography (MCG).

Optics Express•May 3, 2021•123 citations

Ultrasensitive SERF atomic magnetometer with a miniaturized hybrid vapor cell

Yintao Ma, Yao Chen, Mingzhi Yu +8 more

Abstract The chip-scale hybrid optical pumping spin-exchange relaxation-free (SERF) atomic magnetometer with a single-beam arrangement has prominent applications in biomagnetic measurements because of its outstanding features, including ultrahigh sensitivity, an enhanced signal-to-noise ratio, homogeneous spin polarization and a much simpler optical configuration than other devices. In this work, a miniaturized single-beam hybrid optical pumping SERF atomic magnetometer based on a microfabricated atomic vapor cell is demonstrated. Although the optically thin Cs atoms are spin-polarized, the dense Rb atoms determine the experimental results. The enhanced signal strength and narrowed resonance linewidth are experimentally proven, which shows the superiority of the proposed magnetometer scheme. By using a differential detection scheme, we effectively suppress optical noise with an approximate five-fold improvement. Moreover, the cell temperature markedly affects the performance of the magnetometer. We systematically investigate the effects of temperature on the magnetometer parameters. The theoretical basis for these effects is explained in detail. The developed miniaturized magnetometer has an optimal magnetic sensitivity of 20 fT/Hz 1/2 . The presented work provides a foundation for the chip-scale integration of ultrahighly sensitive quantum magnetometers that can be used for forward-looking magnetocardiography (MCG) and magnetoencephalography (MEG) applications.

Microsystems & Nanoengineering•Aug 30, 2024•62 citations
A new design of compact zero-field atomic gradiometer was proposed and integrated using alkali vapor cell and customized optical components. This gradiometer used two parallel elliptically polarized lights, whose output intensity was measured to perform gradient magnetic field detection, respectively. To improve the gradiometer’s sensitivity of the magnetic field detection, the gradiometer was operated in the spin-exchange relaxation-free (SERF) regime. For the sensitivity study, the gradiometer was placed in a person-sized four-layer μ-metal magnetic shielding. With the magnetic shield closed up, the sensitivity of each channel was near 34 fT/ √ Hz, and the corresponding gradient sensitivity could reach 14 fT/√ Hz/cm on a 1cm baseline. When the cover of magnetic shielding was removed, the magnetometer sensitivity of single channel was about 90 fT/√ Hz, and the corresponding gradient sensitivity could reach 34 fT/√ Hz/cm. The experimental results implied that in a poor magnetic shielding environment, the performance of magnetometer was limited due to the fluctuations of the environmental magnetic field, while the gradiometer could work well.
Spin-exchange relaxation free alkali-metal magnetometers typically operate in the regime of high optical density, presenting challenges for simple and efficient optical pumping and detection. We describe a high-sensitivity Rb magnetometer using a single elliptically polarized off-resonant laser beam. Circular component of the light creates relatively uniform spin polarization while the linear component is used to measure optical rotation generated by the atoms. Modulation of the atomic spin direction with an oscillating magnetic field shifts the detected signal to high frequencies. Using a fiber-coupled distributed feedback laser, we achieve magnetic field sensitivity of 7 fT/Hz7\text{ }\text{fT}/\sqrt{\text{Hz}}7 fT/Hz​ with a miniature $5\ifmmode\times\else\texttimes\fi{}5\ifmmode\times\else\texttimes\fi{}5\text{ }\text{mm}\text{ }\text{Rb}$ vapor cell.
The high-sensitivity three-axis detection of magnetic fields is widely used in various applications.Our study demonstrates an atomic magnetometer detecting vector magnetic field, of which the core components are one glass cell and two elliptically polarized laser beams.The light-intensity noise is suppressed by differential detection technology, so a higher sensitivity is obtained compared with our previous work.The three-axis average sensitivities of the atomic magnetometer simultaneously reached 14 fT/Hz 1/2 along the x axis, 11 fT/Hz 1/2 along the y axis, and 25 fT/Hz 1/2 along the z axis.Furthermore, the atomic magnetometer's dynamic range was further improved to 150 nT, and its bandwidth was increased to over 200 Hz using a closed-loop control system.The proposed three-axis atomic magnetometer with a large dynamic range and a wide bandwidth holds great promise for biomagnetic measurement in a more challenging environment.
We report on the development of a microfabricated atomic magnetic gradiometer based on optical spectroscopy of alkali atoms in the vapor phase. The gradiometer, which operates in the spin-exchange relaxation free regime, has a length of 60 mm and cross sectional diameter of 12 mm, and consists of two chip-scale atomic magnetometers which are interrogated by a common laser light. The sensor can measure differences in magnetic fields, over a 20 mm baseline, of 10 fT/[Formula: see text] at frequencies above 20 Hz. The maximum rejection of magnetic field noise is 1000 at 10 Hz. By use of a set of compensation coils wrapped around the sensor, we also measure the sensor sensitivity at several external bias field strengths up to 150 mG. This device is useful for applications that require both sensitive gradient field information and high common-mode noise cancellation.
We investigate the ground-state Hanle effect in alkali-metal vapor irradiating by a resonant elliptically polarized light wave. The magneto-optical resonances are observed as a change in the ellipticity parameter of the light wave polarization when scanning the transverse magnetic field near zero. We use a miniature (≈ \approx\,≈0.1250.1250.125 cm3^33) glass cesium vapor cell heated to a relatively low temperature of ≈ \approx\,≈85∘85^\circ85∘C. Under the current experimental conditions, the sensitivity of magnetic field measurements is limited by a technical noise, reaching 180180180 fT/√\surd√Hz in a 200200200 Hz bandwidth. The ultimate photon-shot-noise-limited sensitivity of the method is estimated to be ≈ \approx\,≈555 fT/√\surd√Hz. The proposed scheme is promising for the development of a zero-field atomic magnetometer with reduced heat dissipation of the sensor head and relaxed requirements for magnetic shielding compared to counterparts operating in the spin-exchange relaxation-free regime. These features are of particular value for biomedical applications.
We demonstrate a single-beam atomic magnetometer (AM) capable of measuring a three-axis magnetic field with high-sensitivity, achieved by applying a small DC offset field and a high frequency modulation field. To satisfy the miniaturization demand of AMs, an elliptically polarized light detuned by 50 GHz from the resonance transition center is employed. The circularly polarized component is used to polarize the alkali-metal atoms, while the linearly polarized light is used to detect the dynamics of the polarized spin under a magnetic field. Based on theoretical analysis, parameters that significantly affect the performance are optimized, and a sensitivity of 20 fT/Hz 1/2 in x -axis, 25 fT/Hz 1/2 in y -axis, 30 fT/Hz 1/2 in z -axis is achieved with a miniature 4 × 4 × 4 mm 87 Rb vapor cell. Moreover, we also verify that the operation principle of AMs can be used to null background magnetic fields in-situ with isotropic compensation resolution of 6.7 pT, which provides an effectively precise method for zeroing ambient magnetic field. The high-sensitivity operating of an elliptically-polarized-laser-based magnetometer provides prospective futures for constructing a compact, low-cost AM, which is particularly applicable for non-invasive bio-magnetic imaging such as array-based magnetoencephalography (MEG) and magnetocardiography (MCG).
Abstract The chip-scale hybrid optical pumping spin-exchange relaxation-free (SERF) atomic magnetometer with a single-beam arrangement has prominent applications in biomagnetic measurements because of its outstanding features, including ultrahigh sensitivity, an enhanced signal-to-noise ratio, homogeneous spin polarization and a much simpler optical configuration than other devices. In this work, a miniaturized single-beam hybrid optical pumping SERF atomic magnetometer based on a microfabricated atomic vapor cell is demonstrated. Although the optically thin Cs atoms are spin-polarized, the dense Rb atoms determine the experimental results. The enhanced signal strength and narrowed resonance linewidth are experimentally proven, which shows the superiority of the proposed magnetometer scheme. By using a differential detection scheme, we effectively suppress optical noise with an approximate five-fold improvement. Moreover, the cell temperature markedly affects the performance of the magnetometer. We systematically investigate the effects of temperature on the magnetometer parameters. The theoretical basis for these effects is explained in detail. The developed miniaturized magnetometer has an optimal magnetic sensitivity of 20 fT/Hz 1/2 . The presented work provides a foundation for the chip-scale integration of ultrahighly sensitive quantum magnetometers that can be used for forward-looking magnetocardiography (MCG) and magnetoencephalography (MEG) applications.