Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1701.03236 · Applied Physics Letters

A microfabricated optically-pumped magnetic gradiometer

D. Sheng, Abigail R. Perry, Sean Krzyzewski, S. Geller, John E. Kitching, Svenja A. Knappe

Published Jan 16, 2017• 179 citations
arXivHTMLPDF

Abstract

We report on the development of a microfabricated atomic magnetic gradiometer based on optical spectroscopy of alkali atoms in the vapor phase. The gradiometer, which operates in the spin-exchange relaxation free regime, has a length of 60 mm and cross sectional diameter of 12 mm, and consists of two chip-scale atomic magnetometers which are interrogated by a common laser light. The sensor can measure differences in magnetic fields, over a 20 mm baseline, of 10 fT/[Formula: see text] at frequencies above 20 Hz. The maximum rejection of magnetic field noise is 1000 at 10 Hz. By use of a set of compensation coils wrapped around the sensor, we also measure the sensor sensitivity at several external bias field strengths up to 150 mG. This device is useful for applications that require both sensitive gradient field information and high common-mode noise cancellation.

DOI
10.1063/1.4974349

Related papers

An optically modulated zero-field atomic magnetometer with suppressed spin-exchange broadening

Ricardo Jiménez-Martínez, Svenja A. Knappe, John E. Kitching

We demonstrate an optically pumped (87)Rb magnetometer in a microfabricated vapor cell based on a zero-field dispersive resonance generated by optical modulation of the (87)Rb ground state energy levels. The magnetometer is operated in the spin-exchange relaxation-free regime where high magnetic field sensitivities can be achieved. This device can be useful in applications requiring array-based magnetometers where radio frequency magnetic fields can induce cross-talk among adjacent sensors or affect the source of the magnetic field being measured.

arXiv:1404.0374•Review of Scientific Instruments•Apr 1, 2014•51 citations

A low-power, high-sensitivity micromachined optical magnetometer

Rahul R. Mhaskar, Svenja A. Knappe, John E. Kitching

We demonstrate an optical magnetometer based on a microfabricated 87Rb vapor cell in a micromachined silicon sensor head. The alkali atom density in the vapor cell is increased by heating the cell with light brought to the sensor through an optical fiber, and absorbed by colored filters attached to the cell windows. A second fiber-optically coupled beam optically pumps and interrogates the atoms. The magnetometer operates on 140 mW of heating power and achieves a sensitivity below 20 fT/√Hz throughout most of the frequency band from 15 Hz to 100 Hz. Such a sensor can measure magnetic fields from the human heart and brain.

Applied Physics Letters•Dec 10, 2012•172 citations

A microfabricated photonic magnetometer

Jan Preusser, Svenja A. Knappe, Vladislav P. Gerginov +1 more

An integrated optically-controlled sensor, suitable for remote, high-sensitivity detection of magnetic fields is presented. The operation of the sensor both in earth field in a Bell-Bloom type configuration is demonstrated as well as in a spin-exchange relaxation-free mode (SERF) and reach sensitivities better than 500 fT/radicHz at 10 Hz. The design and initial measurements of a small atomic magnetometer that has no electrical connections near the sensor head is presented. The sensor is fabricated by use of methods derived from microelectromechanical (MEMS) systems and integrated with off-the-shelf micro-optical components. Light is coupled through fibers to and from the sensor head for interrogation of the atoms. Heating of the atomic vapor is achieved by a second fiber-coupled laser source, utilizing the absorption properties of the vapor cell.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2009•10 citations

A zero-field atomic gradiometer with elliptically polarized laser-pumped used for biomagnetic measurement

Kaifeng Yin, Jing Wang, Zhi Liu +3 more

A new design of compact zero-field atomic gradiometer was proposed and integrated using alkali vapor cell and customized optical components. This gradiometer used two parallel elliptically polarized lights, whose output intensity was measured to perform gradient magnetic field detection, respectively. To improve the gradiometer’s sensitivity of the magnetic field detection, the gradiometer was operated in the spin-exchange relaxation-free (SERF) regime. For the sensitivity study, the gradiometer was placed in a person-sized four-layer μ-metal magnetic shielding. With the magnetic shield closed up, the sensitivity of each channel was near 34 fT/ √ Hz, and the corresponding gradient sensitivity could reach 14 fT/√ Hz/cm on a 1cm baseline. When the cover of magnetic shielding was removed, the magnetometer sensitivity of single channel was about 90 fT/√ Hz, and the corresponding gradient sensitivity could reach 34 fT/√ Hz/cm. The experimental results implied that in a poor magnetic shielding environment, the performance of magnetometer was limited due to the fluctuations of the environmental magnetic field, while the gradiometer could work well.

Applied Optics and Photonics China (AOPC): Optoelectronics and Nanophotonics•Nov 5, 2020•2 citations

Microfabricated Spin Polarized Atomic Magnetometers

Ricardo Jiménez-Martínez

Spin polarized atomic magnetometers involve the preparation of atomic spins and their detection for monitoring magnetic fields. Due to the fact that magnetic fields are ubiquitous in our world, spin polarized atomic magnetometers are used in a wide range of applications from the detection of magnetic fields generated by the human heart and brain to the detection of nuclear magnetic resonance. In this thesis we developed microfabricated spin polarized atomic magnetometers. These sensors are based on optical pumping and spin-exchange collisions between alkali atoms and noble gases contained in microfabricated millimeter-scale vapor cells. In the first part of the thesis, we improved different features of current microfabricated optical magnetometers. Specifically, we improved the bandwidth of these devices, without degrading their magnetic field sensitivity, by broadening their magnetic resonance through spin-exchange collisions between alkali atoms. We also implemented all-optical excitation techniques to avoid problems, such as the magnetic perturbation of the environment, induced by the radio-frequency fields used in some of these sensors. In the second part of the thesis we demonstrated a microfluidic chip for the optical production and detection of hyperpolarized Xe gas through spin-exchange collisions with optically pumped Rb atoms. These devices are critical for the widespread use of spin polarized atomic magnetometers in applications requiring simple, compact, low-cost, and portable instrumentation.

•Jan 1, 2013•2 citations

Spin-exchange relaxation-free magnetometry using elliptically polarized light

Vishal Shah, Michael V. Romalis

Spin-exchange relaxation free alkali-metal magnetometers typically operate in the regime of high optical density, presenting challenges for simple and efficient optical pumping and detection. We describe a high-sensitivity Rb magnetometer using a single elliptically polarized off-resonant laser beam. Circular component of the light creates relatively uniform spin polarization while the linear component is used to measure optical rotation generated by the atoms. Modulation of the atomic spin direction with an oscillating magnetic field shifts the detected signal to high frequencies. Using a fiber-coupled distributed feedback laser, we achieve magnetic field sensitivity of $7\text{ }\text{fT}/\sqrt{\text{Hz}}$ with a miniature $5\ifmmode\times\else\texttimes\fi{}5\ifmmode\times\else\texttimes\fi{}5\text{ }\text{mm}\text{ }\text{Rb}$ vapor cell.

arXiv:0903.2447•Physical Review A•Jul 24, 2009•273 citations
We report on the development of a microfabricated atomic magnetic gradiometer based on optical spectroscopy of alkali atoms in the vapor phase. The gradiometer, which operates in the spin-exchange relaxation free regime, has a length of 60 mm and cross sectional diameter of 12 mm, and consists of two chip-scale atomic magnetometers which are interrogated by a common laser light. The sensor can measure differences in magnetic fields, over a 20 mm baseline, of 10 fT/[Formula: see text] at frequencies above 20 Hz. The maximum rejection of magnetic field noise is 1000 at 10 Hz. By use of a set of compensation coils wrapped around the sensor, we also measure the sensor sensitivity at several external bias field strengths up to 150 mG. This device is useful for applications that require both sensitive gradient field information and high common-mode noise cancellation.
We demonstrate an optically pumped (87)Rb magnetometer in a microfabricated vapor cell based on a zero-field dispersive resonance generated by optical modulation of the (87)Rb ground state energy levels. The magnetometer is operated in the spin-exchange relaxation-free regime where high magnetic field sensitivities can be achieved. This device can be useful in applications requiring array-based magnetometers where radio frequency magnetic fields can induce cross-talk among adjacent sensors or affect the source of the magnetic field being measured.
We demonstrate an optical magnetometer based on a microfabricated 87Rb vapor cell in a micromachined silicon sensor head. The alkali atom density in the vapor cell is increased by heating the cell with light brought to the sensor through an optical fiber, and absorbed by colored filters attached to the cell windows. A second fiber-optically coupled beam optically pumps and interrogates the atoms. The magnetometer operates on 140 mW of heating power and achieves a sensitivity below 20 fT/√Hz throughout most of the frequency band from 15 Hz to 100 Hz. Such a sensor can measure magnetic fields from the human heart and brain.
An integrated optically-controlled sensor, suitable for remote, high-sensitivity detection of magnetic fields is presented. The operation of the sensor both in earth field in a Bell-Bloom type configuration is demonstrated as well as in a spin-exchange relaxation-free mode (SERF) and reach sensitivities better than 500 fT/radicHz at 10 Hz. The design and initial measurements of a small atomic magnetometer that has no electrical connections near the sensor head is presented. The sensor is fabricated by use of methods derived from microelectromechanical (MEMS) systems and integrated with off-the-shelf micro-optical components. Light is coupled through fibers to and from the sensor head for interrogation of the atoms. Heating of the atomic vapor is achieved by a second fiber-coupled laser source, utilizing the absorption properties of the vapor cell.
A new design of compact zero-field atomic gradiometer was proposed and integrated using alkali vapor cell and customized optical components. This gradiometer used two parallel elliptically polarized lights, whose output intensity was measured to perform gradient magnetic field detection, respectively. To improve the gradiometer’s sensitivity of the magnetic field detection, the gradiometer was operated in the spin-exchange relaxation-free (SERF) regime. For the sensitivity study, the gradiometer was placed in a person-sized four-layer μ-metal magnetic shielding. With the magnetic shield closed up, the sensitivity of each channel was near 34 fT/ √ Hz, and the corresponding gradient sensitivity could reach 14 fT/√ Hz/cm on a 1cm baseline. When the cover of magnetic shielding was removed, the magnetometer sensitivity of single channel was about 90 fT/√ Hz, and the corresponding gradient sensitivity could reach 34 fT/√ Hz/cm. The experimental results implied that in a poor magnetic shielding environment, the performance of magnetometer was limited due to the fluctuations of the environmental magnetic field, while the gradiometer could work well.
Spin polarized atomic magnetometers involve the preparation of atomic spins and their detection for monitoring magnetic fields. Due to the fact that magnetic fields are ubiquitous in our world, spin polarized atomic magnetometers are used in a wide range of applications from the detection of magnetic fields generated by the human heart and brain to the detection of nuclear magnetic resonance. In this thesis we developed microfabricated spin polarized atomic magnetometers. These sensors are based on optical pumping and spin-exchange collisions between alkali atoms and noble gases contained in microfabricated millimeter-scale vapor cells. In the first part of the thesis, we improved different features of current microfabricated optical magnetometers. Specifically, we improved the bandwidth of these devices, without degrading their magnetic field sensitivity, by broadening their magnetic resonance through spin-exchange collisions between alkali atoms. We also implemented all-optical excitation techniques to avoid problems, such as the magnetic perturbation of the environment, induced by the radio-frequency fields used in some of these sensors. In the second part of the thesis we demonstrated a microfluidic chip for the optical production and detection of hyperpolarized Xe gas through spin-exchange collisions with optically pumped Rb atoms. These devices are critical for the widespread use of spin polarized atomic magnetometers in applications requiring simple, compact, low-cost, and portable instrumentation.
Spin-exchange relaxation free alkali-metal magnetometers typically operate in the regime of high optical density, presenting challenges for simple and efficient optical pumping and detection. We describe a high-sensitivity Rb magnetometer using a single elliptically polarized off-resonant laser beam. Circular component of the light creates relatively uniform spin polarization while the linear component is used to measure optical rotation generated by the atoms. Modulation of the atomic spin direction with an oscillating magnetic field shifts the detected signal to high frequencies. Using a fiber-coupled distributed feedback laser, we achieve magnetic field sensitivity of 7 fT/Hz7\text{ }\text{fT}/\sqrt{\text{Hz}}7 fT/Hz​ with a miniature $5\ifmmode\times\else\texttimes\fi{}5\ifmmode\times\else\texttimes\fi{}5\text{ }\text{mm}\text{ }\text{Rb}$ vapor cell.