arXiv:2111.12310

Intrinsic Pulsed Magnetic Gradiometer in Earth's Field

Kaleb Campbell, Ying-Ju Wang, Igor Savukov, Peter D. D. Schwindt, Yuan‐Yu Jau, Vishal Shah

Published Nov 24, 2021• 2 citations
arXivHTMLPDF

Abstract

We describe a novel pulsed magnetic gradiometer based on the optical interference of sidebands generated using two spatially separated alkali vapor cells. The sidebands are produced with high efficiency using parametric frequency conversion of a probe beam interacting with $^{87}$Rb atoms in a coherent superposition of magnetically sensitive hyperfine ground states. Interference between the sidebands generates a low-frequency beat note whose frequency is determined by the magnetic field gradient between the two vapor cells. In contrast to traditional magnetic gradiometers, our approach provides a direct readout of the gradient field without the intermediate step of subtracting the outputs of two spacially separated magnetometers. The technique is expected to provide effective common-mode magnetic field cancellation at frequencies far greater than the bandwidth of the gradiometer. Using this technique, we developed a compact magnetic gradiometer sensor head with integrated optics with a sensitivity of $25 \ fT/cm/\sqrt{Hz}$ with a $4.4$ cm baseline, while operating in a noisy laboratory environment unshielded from Earth's field. We also outline a theoretical framework that accurately models sideband generation using a density matrix formalism.

DOI
10.48550/arxiv.2111.12310

Related papers

Gradient Field Detection Using Interference of Stimulated Microwave Optical Sidebands

Kaleb Campbell, Ying-Ju Wang, Igor Savukov +3 more

We demonstrate that stimulated microwave optical sideband generation using parametric frequency conversion can be utilized as a powerful technique for coherent state detection in atomic physics experiments. The technique has advantages over traditional absorption or polarization rotation-based measurements and enables the isolation of signal photons from probe photons. We outline a theoretical framework that accurately models sideband generation using a density matrix formalism. Using this technique, we demonstrate a novel intrinsic magnetic gradiometer that detects magnetic gradient fields between two spatially separated vapor cells by measuring the frequency of the beat note between sidebands generated within each cell. The sidebands are produced with high efficiency using parametric frequency conversion of a probe beam interacting with ^{87}Rb atoms in a coherent superposition of magnetically sensitive hyperfine ground states. Interference between the sidebands generates a low-frequency beat note whose frequency is determined by the magnetic field gradient between the two vapor cells. In contrast to traditional gradiometers the intermediate step of measuring the magnetic field experienced by the two vapor cells is unnecessary. We show that this technique can be readily implemented in a practical device by demonstrating a compact magnetic gradiometer sensor head with a sensitivity of 25 fT/cm/sqrt[Hz] with a 4.4 cm baseline, while operating in a noisy laboratory environment unshielded from Earth's field.

Physical Review Letters•Apr 21, 2022•4 citations

Portable intrinsic gradiometer for ultra-sensitive detection of magnetic gradient in unshielded environment

Rui Zhang, Rahul Mhaskar, Ken Smith +1 more

We demonstrate a portable all-optical intrinsic scalar magnetic gradiometer composed of miniaturized cesium vapor cells and vertical-cavity surface-emitting lasers (VCSELs). Two cells, with inner dimensions of 5 mm × 5 mm × 5 mm and separated by a baseline of 5 cm, are driven by one VCSEL, and the resulting Larmor precessions are probed by a second VCSEL through optical rotation. The off-resonant linearly polarized probe light interrogates two cells at the same time, and the output of the intrinsic gradiometer is proportional to the magnetic field gradient measured over the given baseline. This intrinsic gradiometer scheme has the advantage of avoiding added noise from combining two scalar magnetometers. We achieve a sensitivity better than 18 fT/cm/√Hz in the gradient measurement. Ultra-sensitive short-baseline magnetic gradiometers can potentially play an important role in many practical applications, such as nondestructive evaluation and unexploded ordnance detection. Another application of the gradiometer is for magnetocardiography (MCG) in an unshielded environment. Real-time MCG signals can be extracted from the raw gradiometer readings. The demonstrated gradiometer greatly simplifies the MCG setup and may lead to a ubiquitous MCG measurement in the future.

arXiv:2002.05860•Applied Physics Letters•Apr 6, 2020•48 citations

A microfabricated optically-pumped magnetic gradiometer

D. Sheng, Abigail R. Perry, Sean Krzyzewski +3 more

We report on the development of a microfabricated atomic magnetic gradiometer based on optical spectroscopy of alkali atoms in the vapor phase. The gradiometer, which operates in the spin-exchange relaxation free regime, has a length of 60 mm and cross sectional diameter of 12 mm, and consists of two chip-scale atomic magnetometers which are interrogated by a common laser light. The sensor can measure differences in magnetic fields, over a 20 mm baseline, of 10 fT/[Formula: see text] at frequencies above 20 Hz. The maximum rejection of magnetic field noise is 1000 at 10 Hz. By use of a set of compensation coils wrapped around the sensor, we also measure the sensor sensitivity at several external bias field strengths up to 150 mG. This device is useful for applications that require both sensitive gradient field information and high common-mode noise cancellation.

arXiv:1701.03236•Applied Physics Letters•Jan 16, 2017•179 citations

A zero-field atomic gradiometer with elliptically polarized laser-pumped used for biomagnetic measurement

Kaifeng Yin, Jing Wang, Zhi Liu +3 more

A new design of compact zero-field atomic gradiometer was proposed and integrated using alkali vapor cell and customized optical components. This gradiometer used two parallel elliptically polarized lights, whose output intensity was measured to perform gradient magnetic field detection, respectively. To improve the gradiometer’s sensitivity of the magnetic field detection, the gradiometer was operated in the spin-exchange relaxation-free (SERF) regime. For the sensitivity study, the gradiometer was placed in a person-sized four-layer μ-metal magnetic shielding. With the magnetic shield closed up, the sensitivity of each channel was near 34 fT/ √ Hz, and the corresponding gradient sensitivity could reach 14 fT/√ Hz/cm on a 1cm baseline. When the cover of magnetic shielding was removed, the magnetometer sensitivity of single channel was about 90 fT/√ Hz, and the corresponding gradient sensitivity could reach 34 fT/√ Hz/cm. The experimental results implied that in a poor magnetic shielding environment, the performance of magnetometer was limited due to the fluctuations of the environmental magnetic field, while the gradiometer could work well.

Applied Optics and Photonics China (AOPC): Optoelectronics and Nanophotonics•Nov 5, 2020•2 citations

Pulsed vector atomic magnetometer using an alternating fast-rotating field

Tao Wang, Wonjae Lee, Mark E. Limes +3 more

Abstract We introduce a vector atomic magnetometer that employs a fast-rotating magnetic field applied to a pulsed 87Rb scalar atomic magnetometer. This approach enables simultaneous measurements of the total magnetic field and its two polar angles relative to the rotation plane. Operating in gradiometer mode, the magnetometer achieves a total field gradient sensitivity of 35 $${{{\rm{fT}}}}/\sqrt{{{{\rm{Hz}}}}}$$ fT / Hz (0.7 parts per billion) and angular resolutions of 6 $${{{\rm{nrad}}}}/\sqrt{{{{\rm{Hz}}}}}$$ nrad / Hz at a 50 μT Earth field strength. The noise spectra remain flat down to 1 Hz and 0.1 Hz, respectively. Here we show that this method overcomes several metrological challenges commonly faced by vector magnetometers and gradiometers. We propose a unique peak-altering modulation technique to mitigate systematic effects, including a newly identified dynamic heading error. Additionally, we establish the fundamental sensitivity limits of the sensor, demonstrating that its vector sensitivity approaches scalar sensitivity while preserving the inherent accuracy and calibration benefits of scalar sensors. This high-dynamic-range, ultrahigh-resolution magnetometer offers exceptional versatility for diverse applications.

arXiv:2304.00214•Nature Communications•Feb 5, 2025•29 citations

All-optical intrinsic atomic gradiometer with sub-20 fT/cm/√Hz sensitivity in a 22 µT earth-scale magnetic field

Abigail R. Perry, Michael Bulatowicz, M. Larsen +2 more

In this work we demonstrate a high sensitivity atomic gradiometer capable of operation in earth-field level environments. We apply a light-pulse sequence at four times the Larmor frequency to achieve gradiometer sensitivity <20 fT/cm/ H z at the finite field strength of 22 µT. The experimental timing sequence can be tuned to the field magnitude of interest. Our all-optical scalar gradiometer performs a differential measurement between two regions of a single vapor cell on a 4 cm baseline. Our results pave the way for extensions to operation in higher dimensions, vector sensitivity, and more advanced gradiometers.

arXiv:2008.13234•Optics Express•Nov 10, 2020•38 citations
We describe a novel pulsed magnetic gradiometer based on the optical interference of sidebands generated using two spatially separated alkali vapor cells. The sidebands are produced with high efficiency using parametric frequency conversion of a probe beam interacting with 87^{87}87Rb atoms in a coherent superposition of magnetically sensitive hyperfine ground states. Interference between the sidebands generates a low-frequency beat note whose frequency is determined by the magnetic field gradient between the two vapor cells. In contrast to traditional magnetic gradiometers, our approach provides a direct readout of the gradient field without the intermediate step of subtracting the outputs of two spacially separated magnetometers. The technique is expected to provide effective common-mode magnetic field cancellation at frequencies far greater than the bandwidth of the gradiometer. Using this technique, we developed a compact magnetic gradiometer sensor head with integrated optics with a sensitivity of 25 fT/cm/Hz25 \ fT/cm/\sqrt{Hz}25 fT/cm/Hz​ with a 4.44.44.4 cm baseline, while operating in a noisy laboratory environment unshielded from Earth's field. We also outline a theoretical framework that accurately models sideband generation using a density matrix formalism.
We demonstrate that stimulated microwave optical sideband generation using parametric frequency conversion can be utilized as a powerful technique for coherent state detection in atomic physics experiments. The technique has advantages over traditional absorption or polarization rotation-based measurements and enables the isolation of signal photons from probe photons. We outline a theoretical framework that accurately models sideband generation using a density matrix formalism. Using this technique, we demonstrate a novel intrinsic magnetic gradiometer that detects magnetic gradient fields between two spatially separated vapor cells by measuring the frequency of the beat note between sidebands generated within each cell. The sidebands are produced with high efficiency using parametric frequency conversion of a probe beam interacting with ^{87}Rb atoms in a coherent superposition of magnetically sensitive hyperfine ground states. Interference between the sidebands generates a low-frequency beat note whose frequency is determined by the magnetic field gradient between the two vapor cells. In contrast to traditional gradiometers the intermediate step of measuring the magnetic field experienced by the two vapor cells is unnecessary. We show that this technique can be readily implemented in a practical device by demonstrating a compact magnetic gradiometer sensor head with a sensitivity of 25 fT/cm/sqrt[Hz] with a 4.4 cm baseline, while operating in a noisy laboratory environment unshielded from Earth's field.
We demonstrate a portable all-optical intrinsic scalar magnetic gradiometer composed of miniaturized cesium vapor cells and vertical-cavity surface-emitting lasers (VCSELs). Two cells, with inner dimensions of 5 mm × 5 mm × 5 mm and separated by a baseline of 5 cm, are driven by one VCSEL, and the resulting Larmor precessions are probed by a second VCSEL through optical rotation. The off-resonant linearly polarized probe light interrogates two cells at the same time, and the output of the intrinsic gradiometer is proportional to the magnetic field gradient measured over the given baseline. This intrinsic gradiometer scheme has the advantage of avoiding added noise from combining two scalar magnetometers. We achieve a sensitivity better than 18 fT/cm/√Hz in the gradient measurement. Ultra-sensitive short-baseline magnetic gradiometers can potentially play an important role in many practical applications, such as nondestructive evaluation and unexploded ordnance detection. Another application of the gradiometer is for magnetocardiography (MCG) in an unshielded environment. Real-time MCG signals can be extracted from the raw gradiometer readings. The demonstrated gradiometer greatly simplifies the MCG setup and may lead to a ubiquitous MCG measurement in the future.
We report on the development of a microfabricated atomic magnetic gradiometer based on optical spectroscopy of alkali atoms in the vapor phase. The gradiometer, which operates in the spin-exchange relaxation free regime, has a length of 60 mm and cross sectional diameter of 12 mm, and consists of two chip-scale atomic magnetometers which are interrogated by a common laser light. The sensor can measure differences in magnetic fields, over a 20 mm baseline, of 10 fT/[Formula: see text] at frequencies above 20 Hz. The maximum rejection of magnetic field noise is 1000 at 10 Hz. By use of a set of compensation coils wrapped around the sensor, we also measure the sensor sensitivity at several external bias field strengths up to 150 mG. This device is useful for applications that require both sensitive gradient field information and high common-mode noise cancellation.
A new design of compact zero-field atomic gradiometer was proposed and integrated using alkali vapor cell and customized optical components. This gradiometer used two parallel elliptically polarized lights, whose output intensity was measured to perform gradient magnetic field detection, respectively. To improve the gradiometer’s sensitivity of the magnetic field detection, the gradiometer was operated in the spin-exchange relaxation-free (SERF) regime. For the sensitivity study, the gradiometer was placed in a person-sized four-layer μ-metal magnetic shielding. With the magnetic shield closed up, the sensitivity of each channel was near 34 fT/ √ Hz, and the corresponding gradient sensitivity could reach 14 fT/√ Hz/cm on a 1cm baseline. When the cover of magnetic shielding was removed, the magnetometer sensitivity of single channel was about 90 fT/√ Hz, and the corresponding gradient sensitivity could reach 34 fT/√ Hz/cm. The experimental results implied that in a poor magnetic shielding environment, the performance of magnetometer was limited due to the fluctuations of the environmental magnetic field, while the gradiometer could work well.
Abstract We introduce a vector atomic magnetometer that employs a fast-rotating magnetic field applied to a pulsed 87Rb scalar atomic magnetometer. This approach enables simultaneous measurements of the total magnetic field and its two polar angles relative to the rotation plane. Operating in gradiometer mode, the magnetometer achieves a total field gradient sensitivity of 35 fT/Hz{{{\rm{fT}}}}/\sqrt{{{{\rm{Hz}}}}}fT/Hz​ fT / Hz (0.7 parts per billion) and angular resolutions of 6 nrad/Hz{{{\rm{nrad}}}}/\sqrt{{{{\rm{Hz}}}}}nrad/Hz​ nrad / Hz at a 50 μT Earth field strength. The noise spectra remain flat down to 1 Hz and 0.1 Hz, respectively. Here we show that this method overcomes several metrological challenges commonly faced by vector magnetometers and gradiometers. We propose a unique peak-altering modulation technique to mitigate systematic effects, including a newly identified dynamic heading error. Additionally, we establish the fundamental sensitivity limits of the sensor, demonstrating that its vector sensitivity approaches scalar sensitivity while preserving the inherent accuracy and calibration benefits of scalar sensors. This high-dynamic-range, ultrahigh-resolution magnetometer offers exceptional versatility for diverse applications.
In this work we demonstrate a high sensitivity atomic gradiometer capable of operation in earth-field level environments. We apply a light-pulse sequence at four times the Larmor frequency to achieve gradiometer sensitivity <20 fT/cm/ H z at the finite field strength of 22 µT. The experimental timing sequence can be tuned to the field magnitude of interest. Our all-optical scalar gradiometer performs a differential measurement between two regions of a single vapor cell on a 4 cm baseline. Our results pave the way for extensions to operation in higher dimensions, vector sensitivity, and more advanced gradiometers.