arXiv:2008.13234 · Optics Express

All-optical intrinsic atomic gradiometer with sub-20 fT/cm/√Hz sensitivity in a 22 µT earth-scale magnetic field

Abigail R. Perry, Michael Bulatowicz, M. Larsen, Thad G Walker, Robert Wyllie

Published Nov 10, 2020• 38 citations
arXivHTMLPDF

Abstract

In this work we demonstrate a high sensitivity atomic gradiometer capable of operation in earth-field level environments. We apply a light-pulse sequence at four times the Larmor frequency to achieve gradiometer sensitivity <20 fT/cm/ H z at the finite field strength of 22 µT. The experimental timing sequence can be tuned to the field magnitude of interest. Our all-optical scalar gradiometer performs a differential measurement between two regions of a single vapor cell on a 4 cm baseline. Our results pave the way for extensions to operation in higher dimensions, vector sensitivity, and more advanced gradiometers.

DOI
10.1364/oe.408486

Related papers

Pulsed vector atomic magnetometer using an alternating fast-rotating field

Tao Wang, Wonjae Lee, Mark E. Limes +3 more

Abstract We introduce a vector atomic magnetometer that employs a fast-rotating magnetic field applied to a pulsed 87Rb scalar atomic magnetometer. This approach enables simultaneous measurements of the total magnetic field and its two polar angles relative to the rotation plane. Operating in gradiometer mode, the magnetometer achieves a total field gradient sensitivity of 35 $${{{\rm{fT}}}}/\sqrt{{{{\rm{Hz}}}}}$$ fT / Hz (0.7 parts per billion) and angular resolutions of 6 $${{{\rm{nrad}}}}/\sqrt{{{{\rm{Hz}}}}}$$ nrad / Hz at a 50 μT Earth field strength. The noise spectra remain flat down to 1 Hz and 0.1 Hz, respectively. Here we show that this method overcomes several metrological challenges commonly faced by vector magnetometers and gradiometers. We propose a unique peak-altering modulation technique to mitigate systematic effects, including a newly identified dynamic heading error. Additionally, we establish the fundamental sensitivity limits of the sensor, demonstrating that its vector sensitivity approaches scalar sensitivity while preserving the inherent accuracy and calibration benefits of scalar sensors. This high-dynamic-range, ultrahigh-resolution magnetometer offers exceptional versatility for diverse applications.

arXiv:2304.00214•Nature Communications•Feb 5, 2025•29 citations

Portable intrinsic gradiometer for ultra-sensitive detection of magnetic gradient in unshielded environment

Rui Zhang, Rahul Mhaskar, Ken Smith +1 more

We demonstrate a portable all-optical intrinsic scalar magnetic gradiometer composed of miniaturized cesium vapor cells and vertical-cavity surface-emitting lasers (VCSELs). Two cells, with inner dimensions of 5 mm × 5 mm × 5 mm and separated by a baseline of 5 cm, are driven by one VCSEL, and the resulting Larmor precessions are probed by a second VCSEL through optical rotation. The off-resonant linearly polarized probe light interrogates two cells at the same time, and the output of the intrinsic gradiometer is proportional to the magnetic field gradient measured over the given baseline. This intrinsic gradiometer scheme has the advantage of avoiding added noise from combining two scalar magnetometers. We achieve a sensitivity better than 18 fT/cm/√Hz in the gradient measurement. Ultra-sensitive short-baseline magnetic gradiometers can potentially play an important role in many practical applications, such as nondestructive evaluation and unexploded ordnance detection. Another application of the gradiometer is for magnetocardiography (MCG) in an unshielded environment. Real-time MCG signals can be extracted from the raw gradiometer readings. The demonstrated gradiometer greatly simplifies the MCG setup and may lead to a ubiquitous MCG measurement in the future.

arXiv:2002.05860•Applied Physics Letters•Apr 6, 2020•48 citations

Total-field atomic magnetometry using an elliptically-polarized frequency-modulated light beam for geomagnetic-field applications

Denis V. Brazhnikov, A. O. Makarov, K. S. Kozlova +10 more

We investigate an all-optical scheme for high-sensitivity measurements of the Earth's scale magnetic field ($B$). The scheme is based on the Bell-Bloom technique with frequency-modulated light. A single elliptically polarized light beam is used both for pumping the alkali-metal atoms and probing Larmor precession of their spins under the external magnetic field. In contrast to many other high-sensitivity magnetometry schemes based on nonlinear polarization rotation of the light, the proposed approach enables the observation of magnetic resonance via changes in the light-beam ellipticity parameter. The approach has been validated in experiments with a vertical-cavity surface-emitting laser, irradiating a $0.125$ cm$^3$ cesium vapor cell filled with a buffer gas. In the current experimental conditions, the achieved sensitivity is estimated at $220$ fT/$\surd$Hz under $B$$\,\approx\,$$50$ $μ$T, while the shot-noise floor corresponds to $\approx\,$$20$ fT/$\surd$Hz. The bandwidth is estimated at $\approx\,$$1$ kHz. The proposed simple and robust single-beam scheme is well suited for miniaturization and is therefore particularly promising for the development of compact, highly sensitive, low-power-consumption atomic magnetometers for a wide range of applications in the geomagnetic field.

arXiv:2610.08031•Oct 6, 2026•0 citations

A zero-field atomic gradiometer with elliptically polarized laser-pumped used for biomagnetic measurement

Kaifeng Yin, Jing Wang, Zhi Liu +3 more

A new design of compact zero-field atomic gradiometer was proposed and integrated using alkali vapor cell and customized optical components. This gradiometer used two parallel elliptically polarized lights, whose output intensity was measured to perform gradient magnetic field detection, respectively. To improve the gradiometer’s sensitivity of the magnetic field detection, the gradiometer was operated in the spin-exchange relaxation-free (SERF) regime. For the sensitivity study, the gradiometer was placed in a person-sized four-layer μ-metal magnetic shielding. With the magnetic shield closed up, the sensitivity of each channel was near 34 fT/ √ Hz, and the corresponding gradient sensitivity could reach 14 fT/√ Hz/cm on a 1cm baseline. When the cover of magnetic shielding was removed, the magnetometer sensitivity of single channel was about 90 fT/√ Hz, and the corresponding gradient sensitivity could reach 34 fT/√ Hz/cm. The experimental results implied that in a poor magnetic shielding environment, the performance of magnetometer was limited due to the fluctuations of the environmental magnetic field, while the gradiometer could work well.

Applied Optics and Photonics China (AOPC): Optoelectronics and Nanophotonics•Nov 5, 2020•2 citations

Intrinsic Pulsed Magnetic Gradiometer in Earth's Field

Kaleb Campbell, Ying-Ju Wang, Igor Savukov +3 more

We describe a novel pulsed magnetic gradiometer based on the optical interference of sidebands generated using two spatially separated alkali vapor cells. The sidebands are produced with high efficiency using parametric frequency conversion of a probe beam interacting with $^{87}$Rb atoms in a coherent superposition of magnetically sensitive hyperfine ground states. Interference between the sidebands generates a low-frequency beat note whose frequency is determined by the magnetic field gradient between the two vapor cells. In contrast to traditional magnetic gradiometers, our approach provides a direct readout of the gradient field without the intermediate step of subtracting the outputs of two spacially separated magnetometers. The technique is expected to provide effective common-mode magnetic field cancellation at frequencies far greater than the bandwidth of the gradiometer. Using this technique, we developed a compact magnetic gradiometer sensor head with integrated optics with a sensitivity of $25 \ fT/cm/\sqrt{Hz}$ with a $4.4$ cm baseline, while operating in a noisy laboratory environment unshielded from Earth's field. We also outline a theoretical framework that accurately models sideband generation using a density matrix formalism.

arXiv:2111.12310•Nov 24, 2021•2 citations

Sensitivity of a vector atomic magnetometer based on electromagnetically induced transparency

Irina V. Novikova, Eugeniy E. Mikhailov, John E. Kitching +8 more

We present a realization of a magnetic sensor based on electromagnetically induced transparency (EIT) resonances observed in hot Rb vapor using lin$\parallel$lin polarized dichromatic light and evaluate scalar and vector capabilities of the sensor for measuring Earth-like magnetic fields. We demonstrate scalar measurement sensitivity of 2 pT/Hz^1/2 in the 1-100~Hz spectral frequency band using a cm^3 Rb vapor cell, significantly improving the performance for such a configuration if compared with earlier measurements of large magnetic fields. By using a single linearly polarized dichromatic optical field, we are also able to determine the direction of the magnetic field with respect to the light propagation direction and polarization, taking advantage of the symmetries of the interaction scheme. We accomplish that by combining the polarization-sensitive transmission measurements and sparse sensing machine learning techniques. A path for further improvement of the sensitivity and elimination of systematic effects, such as heading error, is discussed.

•May 6, 2024•0 citations
In this work we demonstrate a high sensitivity atomic gradiometer capable of operation in earth-field level environments. We apply a light-pulse sequence at four times the Larmor frequency to achieve gradiometer sensitivity <20 fT/cm/ H z at the finite field strength of 22 µT. The experimental timing sequence can be tuned to the field magnitude of interest. Our all-optical scalar gradiometer performs a differential measurement between two regions of a single vapor cell on a 4 cm baseline. Our results pave the way for extensions to operation in higher dimensions, vector sensitivity, and more advanced gradiometers.
Abstract We introduce a vector atomic magnetometer that employs a fast-rotating magnetic field applied to a pulsed 87Rb scalar atomic magnetometer. This approach enables simultaneous measurements of the total magnetic field and its two polar angles relative to the rotation plane. Operating in gradiometer mode, the magnetometer achieves a total field gradient sensitivity of 35 fT/Hz{{{\rm{fT}}}}/\sqrt{{{{\rm{Hz}}}}}fT/Hz​ fT / Hz (0.7 parts per billion) and angular resolutions of 6 nrad/Hz{{{\rm{nrad}}}}/\sqrt{{{{\rm{Hz}}}}}nrad/Hz​ nrad / Hz at a 50 μT Earth field strength. The noise spectra remain flat down to 1 Hz and 0.1 Hz, respectively. Here we show that this method overcomes several metrological challenges commonly faced by vector magnetometers and gradiometers. We propose a unique peak-altering modulation technique to mitigate systematic effects, including a newly identified dynamic heading error. Additionally, we establish the fundamental sensitivity limits of the sensor, demonstrating that its vector sensitivity approaches scalar sensitivity while preserving the inherent accuracy and calibration benefits of scalar sensors. This high-dynamic-range, ultrahigh-resolution magnetometer offers exceptional versatility for diverse applications.
We demonstrate a portable all-optical intrinsic scalar magnetic gradiometer composed of miniaturized cesium vapor cells and vertical-cavity surface-emitting lasers (VCSELs). Two cells, with inner dimensions of 5 mm × 5 mm × 5 mm and separated by a baseline of 5 cm, are driven by one VCSEL, and the resulting Larmor precessions are probed by a second VCSEL through optical rotation. The off-resonant linearly polarized probe light interrogates two cells at the same time, and the output of the intrinsic gradiometer is proportional to the magnetic field gradient measured over the given baseline. This intrinsic gradiometer scheme has the advantage of avoiding added noise from combining two scalar magnetometers. We achieve a sensitivity better than 18 fT/cm/√Hz in the gradient measurement. Ultra-sensitive short-baseline magnetic gradiometers can potentially play an important role in many practical applications, such as nondestructive evaluation and unexploded ordnance detection. Another application of the gradiometer is for magnetocardiography (MCG) in an unshielded environment. Real-time MCG signals can be extracted from the raw gradiometer readings. The demonstrated gradiometer greatly simplifies the MCG setup and may lead to a ubiquitous MCG measurement in the future.
We investigate an all-optical scheme for high-sensitivity measurements of the Earth's scale magnetic field (BBB). The scheme is based on the Bell-Bloom technique with frequency-modulated light. A single elliptically polarized light beam is used both for pumping the alkali-metal atoms and probing Larmor precession of their spins under the external magnetic field. In contrast to many other high-sensitivity magnetometry schemes based on nonlinear polarization rotation of the light, the proposed approach enables the observation of magnetic resonance via changes in the light-beam ellipticity parameter. The approach has been validated in experiments with a vertical-cavity surface-emitting laser, irradiating a 0.1250.1250.125 cm3^33 cesium vapor cell filled with a buffer gas. In the current experimental conditions, the achieved sensitivity is estimated at 220220220 fT/√\surd√Hz under BBB ≈ \,\approx\,≈505050 μμμT, while the shot-noise floor corresponds to ≈ \approx\,≈202020 fT/√\surd√Hz. The bandwidth is estimated at ≈ \approx\,≈111 kHz. The proposed simple and robust single-beam scheme is well suited for miniaturization and is therefore particularly promising for the development of compact, highly sensitive, low-power-consumption atomic magnetometers for a wide range of applications in the geomagnetic field.
A new design of compact zero-field atomic gradiometer was proposed and integrated using alkali vapor cell and customized optical components. This gradiometer used two parallel elliptically polarized lights, whose output intensity was measured to perform gradient magnetic field detection, respectively. To improve the gradiometer’s sensitivity of the magnetic field detection, the gradiometer was operated in the spin-exchange relaxation-free (SERF) regime. For the sensitivity study, the gradiometer was placed in a person-sized four-layer μ-metal magnetic shielding. With the magnetic shield closed up, the sensitivity of each channel was near 34 fT/ √ Hz, and the corresponding gradient sensitivity could reach 14 fT/√ Hz/cm on a 1cm baseline. When the cover of magnetic shielding was removed, the magnetometer sensitivity of single channel was about 90 fT/√ Hz, and the corresponding gradient sensitivity could reach 34 fT/√ Hz/cm. The experimental results implied that in a poor magnetic shielding environment, the performance of magnetometer was limited due to the fluctuations of the environmental magnetic field, while the gradiometer could work well.
We describe a novel pulsed magnetic gradiometer based on the optical interference of sidebands generated using two spatially separated alkali vapor cells. The sidebands are produced with high efficiency using parametric frequency conversion of a probe beam interacting with 87^{87}87Rb atoms in a coherent superposition of magnetically sensitive hyperfine ground states. Interference between the sidebands generates a low-frequency beat note whose frequency is determined by the magnetic field gradient between the two vapor cells. In contrast to traditional magnetic gradiometers, our approach provides a direct readout of the gradient field without the intermediate step of subtracting the outputs of two spacially separated magnetometers. The technique is expected to provide effective common-mode magnetic field cancellation at frequencies far greater than the bandwidth of the gradiometer. Using this technique, we developed a compact magnetic gradiometer sensor head with integrated optics with a sensitivity of 25 fT/cm/Hz25 \ fT/cm/\sqrt{Hz}25 fT/cm/Hz​ with a 4.44.44.4 cm baseline, while operating in a noisy laboratory environment unshielded from Earth's field. We also outline a theoretical framework that accurately models sideband generation using a density matrix formalism.
We present a realization of a magnetic sensor based on electromagnetically induced transparency (EIT) resonances observed in hot Rb vapor using lin∥\parallel∥lin polarized dichromatic light and evaluate scalar and vector capabilities of the sensor for measuring Earth-like magnetic fields. We demonstrate scalar measurement sensitivity of 2 pT/Hz^1/2 in the 1-100~Hz spectral frequency band using a cm^3 Rb vapor cell, significantly improving the performance for such a configuration if compared with earlier measurements of large magnetic fields. By using a single linearly polarized dichromatic optical field, we are also able to determine the direction of the magnetic field with respect to the light propagation direction and polarization, taking advantage of the symmetries of the interaction scheme. We accomplish that by combining the polarization-sensitive transmission measurements and sparse sensing machine learning techniques. A path for further improvement of the sensitivity and elimination of systematic effects, such as heading error, is discussed.