arXiv:1803.06462 · Review of Scientific Instruments

500 MHz resonant photodetector for high-quantum-efficiency, low-noise homodyne measurement

Takahiro Serikawa, Akira Furusawa

Published Jun 1, 2018• 24 citations
arXivHTMLPDF

Abstract

We design and demonstrate a resonant-type differential photodetector for a low-noise quantum homodyne measurement at 500 MHz optical sideband with 17 MHz of bandwidth. By using a microwave monolithic amplifier and a discrete voltage buffer circuit, a low-noise voltage amplifier is realized and applied to our detector. 12 dB of signal-to-noise ratio of the shot noise to the electric noise is obtained with 5 mW of a continuous-wave local oscillator. We analyze the frequency response and the noise characteristics of a resonant photodetector, and the theoretical model agrees with the shot noise measurement.

DOI
10.1063/1.5029859

Related papers

Simulation of high signal-to-noise ratio resonant photodetector for homodyne measurement and its verification

S. B. Wang, Wei Liu, Xuyin Niu +2 more

In this paper, two models for simulating the shot noise and electronic noise performances of resonant photodetectors designed for homodyne measurements are presented. One is based on a combination of a buffer and a low-noise amplifier, and the other is based on an operational amplifier. Through the comparisons between the numerical simulation results and the experimentally obtained data, excellent agreements are achieved, which show that the models provide a highly efficient guide for the development of a high signal-to-noise ratio (SNR) resonant photodetector. Furthermore, we demonstrate a high SNR resonant photodetector for homodyne measurements at the 147 MHz optical sideband, achieving a 20.8 dB SNR of the shot noise to the electronic noise with a 2 mW optical signal input, utilizing a combination of a buffer and a low-noise amplifier. Concurrently, we have obtained another resonant photodetector at the 1.14 GHz optical sideband, which exhibits a 13 dB SNR based on an operational amplifier.

Review of Scientific Instruments•Jan 1, 2025•1 citation

20 MHz resonant photodetector for the homodyne measurement of picosecond pulsed squeezed light

Zhihao Li, Jun Liu, Fengjuan Guo +3 more

A high-performance resonant balanced homodyne detector is a key element for the measurement of picosecond pulsed squeezed light, which is an important quantum resource in quantum-enhanced microscopic imaging. In this paper, we design and demonstrate a resonant photodetector for homodyne measurement with a maximum signal-to-noise ratio of 22.42 dB at resonant frequency of 20 MHz. Using this detector to pulsed regime, a maximum signal-to-noise ratio at resonant frequency is 10.02 dB, where a 40 dB subtraction capability at 80 MHz repetition rate of pulsed laser is obtained. With this design, the quantum noise of picosecond pulsed squeezed light is measured and the best squeezing level −1.7 dB below the shot noise level is clearly observed at 20 MHz.

Optics Continuum•Feb 1, 2023•6 citations

A low-noise, high-SNR and large-dynamic-range balanced homodyne detector for broadband squeezed light measurement

Jinrong Wang, Shuange Wu, Liying Hou +3 more

Squeezing-based quantum metrology has been extensively applied in the field of precision measurement. Performance characteristics of squeezed light are obtained by a balanced homodyne detector. Here, we report a large dynamic range balanced homodyne detector with low-noise and high-signal-to-noise-ratio (SNR) for broadband squeezed light measurement. We perform a comprehensive theoretical analysis of the SNR in a wide bandwidth and experimentally analyze the important printed circuit board (PCB) layout and electronic components. Consequently, in the 100 MHz frequency band, the SNR and common mode rejection ratio (CMRR) rise over 12.6 dB and 55 dB, respectively, and the electronic noise is suppressed below -90 dB. The directly observed squeezing level at 1550 nm with the specified detector is 11.8 dB at 2 MHz and 3.1 dB at 100 MHz.

Results in Physics•Jan 18, 2024•5 citations

Design of low-noise photodetector with a bandwidth of 130 MHz based on transimpedance amplification circuit

Jiliang Qin, Zhihui Yan, Meiru Huo +2 more

A low-noise photodetector is a basic tool for the research of quantum information processing.We present a specially designed low-noise photoelectric detector with a bandwidth of 130 MHz, using a transimpedance amplification circuit.Based on the detailed calculation of the dependence on each parameter of the detector, a useful method of how to design a low-noise and broadband photodetector is provided.When the optical power is between 1.0 and 16 mW, the photodetector has a good linear response to the injected light.Its electronics noise power is below -77 dBm, which is within the whole bandwidth.When the incident light power is 2 mW, the output noise powers are 10.0, 8.0, and 6.0 dB higher than the corresponding electronics noise within the bandwidth of 1-50, 50-90, and 90-130 MHz, respectively, which is in good agreement with the theoretical prediction.Thus, this photoelectric detector could have good application prospects in quantum communication and an optical cavity locking system.

Chinese Optics Letters•Jan 1, 2016•11 citations

Shot-noise limited homodyne detection for MHz quantum light characterisation in the 2 µm band

Jake Biele, Joel F. Tasker, Joshua W. Silverstone +1 more

Characterising quantum states of light in the 2 µm band requires high-performance shot-noise limited detectors. Here, we present the characterisation of a homodyne detector that we use to observe vacuum shot-noise via homodyne measurement with a 2.07 µm pulsed mode-locked laser. The device is designed primarily for pulsed illumination. It has a 3-dB bandwidth of 13.2 MHz, total conversion efficiency of 57% at 2.07 µm, and a common-mode rejection ratio of 48 dB at 39.5 MHz. The detector begins to saturate at 1.8 mW with 9 dB of shot-noise clearance at 5 MHz. This demonstration enables the characterisation of megahertz-quantum optical behaviour in the 2 µm band and provides a guide of how to design a 2 µm homodyne detector for quantum applications.

arXiv:2112.01382•Optics Express•Feb 11, 2022•2 citations

A Simple and Robust Balanced Homodyne Detector for High-Repetition-Rate Pulsed Sources

Samuele Altilia, Edoardo Suerra, Pietro Puppi +3 more

We design and experimentally characterize a balanced homodyne detector optimized for high-repetition-rate (100 MHz) pulsed optical sources. Unlike conventional transimpedance-amplifier architectures, which suffer from nonlinearities and dynamic instabilities with ultrashort pulses, our approach allows to directly amplify the photocurrent extracted at the common photodiode node without feedback loops. A theoretical model describing the detector response, noise, and pulse-to-pulse correlations is developed, providing quantitative predictions for the signal variance, signal-to-noise ratio (SNR), and inter-pulse correlations. Implemented with two matched InGaAs photodiodes illuminated by a 1030 nm mode-locked laser at 100 MHz, the detector exhibits excellent linearity and shot-noise-limited scaling of the signal variance with optical power. Optimizing the temporal integration window yields a maximum SNR of about 14 dB, while correlation measurements confirm negligible inter-pulse correlations. These results demonstrate that the proposed architecture offers a robust and simple solution for high-speed pulsed homodyne detection, suitable for quantum optics and continuous-variable quantum information applications.

physics.opticsCross-listedarXiv:2604.06994•Apr 9, 2026•0 citations
We design and demonstrate a resonant-type differential photodetector for a low-noise quantum homodyne measurement at 500 MHz optical sideband with 17 MHz of bandwidth. By using a microwave monolithic amplifier and a discrete voltage buffer circuit, a low-noise voltage amplifier is realized and applied to our detector. 12 dB of signal-to-noise ratio of the shot noise to the electric noise is obtained with 5 mW of a continuous-wave local oscillator. We analyze the frequency response and the noise characteristics of a resonant photodetector, and the theoretical model agrees with the shot noise measurement.
In this paper, two models for simulating the shot noise and electronic noise performances of resonant photodetectors designed for homodyne measurements are presented. One is based on a combination of a buffer and a low-noise amplifier, and the other is based on an operational amplifier. Through the comparisons between the numerical simulation results and the experimentally obtained data, excellent agreements are achieved, which show that the models provide a highly efficient guide for the development of a high signal-to-noise ratio (SNR) resonant photodetector. Furthermore, we demonstrate a high SNR resonant photodetector for homodyne measurements at the 147 MHz optical sideband, achieving a 20.8 dB SNR of the shot noise to the electronic noise with a 2 mW optical signal input, utilizing a combination of a buffer and a low-noise amplifier. Concurrently, we have obtained another resonant photodetector at the 1.14 GHz optical sideband, which exhibits a 13 dB SNR based on an operational amplifier.
A high-performance resonant balanced homodyne detector is a key element for the measurement of picosecond pulsed squeezed light, which is an important quantum resource in quantum-enhanced microscopic imaging. In this paper, we design and demonstrate a resonant photodetector for homodyne measurement with a maximum signal-to-noise ratio of 22.42 dB at resonant frequency of 20 MHz. Using this detector to pulsed regime, a maximum signal-to-noise ratio at resonant frequency is 10.02 dB, where a 40 dB subtraction capability at 80 MHz repetition rate of pulsed laser is obtained. With this design, the quantum noise of picosecond pulsed squeezed light is measured and the best squeezing level −1.7 dB below the shot noise level is clearly observed at 20 MHz.
Squeezing-based quantum metrology has been extensively applied in the field of precision measurement. Performance characteristics of squeezed light are obtained by a balanced homodyne detector. Here, we report a large dynamic range balanced homodyne detector with low-noise and high-signal-to-noise-ratio (SNR) for broadband squeezed light measurement. We perform a comprehensive theoretical analysis of the SNR in a wide bandwidth and experimentally analyze the important printed circuit board (PCB) layout and electronic components. Consequently, in the 100 MHz frequency band, the SNR and common mode rejection ratio (CMRR) rise over 12.6 dB and 55 dB, respectively, and the electronic noise is suppressed below -90 dB. The directly observed squeezing level at 1550 nm with the specified detector is 11.8 dB at 2 MHz and 3.1 dB at 100 MHz.
A low-noise photodetector is a basic tool for the research of quantum information processing.We present a specially designed low-noise photoelectric detector with a bandwidth of 130 MHz, using a transimpedance amplification circuit.Based on the detailed calculation of the dependence on each parameter of the detector, a useful method of how to design a low-noise and broadband photodetector is provided.When the optical power is between 1.0 and 16 mW, the photodetector has a good linear response to the injected light.Its electronics noise power is below -77 dBm, which is within the whole bandwidth.When the incident light power is 2 mW, the output noise powers are 10.0, 8.0, and 6.0 dB higher than the corresponding electronics noise within the bandwidth of 1-50, 50-90, and 90-130 MHz, respectively, which is in good agreement with the theoretical prediction.Thus, this photoelectric detector could have good application prospects in quantum communication and an optical cavity locking system.
Characterising quantum states of light in the 2 µm band requires high-performance shot-noise limited detectors. Here, we present the characterisation of a homodyne detector that we use to observe vacuum shot-noise via homodyne measurement with a 2.07 µm pulsed mode-locked laser. The device is designed primarily for pulsed illumination. It has a 3-dB bandwidth of 13.2 MHz, total conversion efficiency of 57% at 2.07 µm, and a common-mode rejection ratio of 48 dB at 39.5 MHz. The detector begins to saturate at 1.8 mW with 9 dB of shot-noise clearance at 5 MHz. This demonstration enables the characterisation of megahertz-quantum optical behaviour in the 2 µm band and provides a guide of how to design a 2 µm homodyne detector for quantum applications.
We design and experimentally characterize a balanced homodyne detector optimized for high-repetition-rate (100 MHz) pulsed optical sources. Unlike conventional transimpedance-amplifier architectures, which suffer from nonlinearities and dynamic instabilities with ultrashort pulses, our approach allows to directly amplify the photocurrent extracted at the common photodiode node without feedback loops. A theoretical model describing the detector response, noise, and pulse-to-pulse correlations is developed, providing quantitative predictions for the signal variance, signal-to-noise ratio (SNR), and inter-pulse correlations. Implemented with two matched InGaAs photodiodes illuminated by a 1030 nm mode-locked laser at 100 MHz, the detector exhibits excellent linearity and shot-noise-limited scaling of the signal variance with optical power. Optimizing the temporal integration window yields a maximum SNR of about 14 dB, while correlation measurements confirm negligible inter-pulse correlations. These results demonstrate that the proposed architecture offers a robust and simple solution for high-speed pulsed homodyne detection, suitable for quantum optics and continuous-variable quantum information applications.