Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2112.01382 · Optics Express

Shot-noise limited homodyne detection for MHz quantum light characterisation in the 2 µm band

Jake Biele, Joel F. Tasker, Joshua W. Silverstone, Jonathan C. F. Matthews

Published Feb 11, 2022• 2 citations
arXivHTMLPDF

Abstract

Characterising quantum states of light in the 2 µm band requires high-performance shot-noise limited detectors. Here, we present the characterisation of a homodyne detector that we use to observe vacuum shot-noise via homodyne measurement with a 2.07 µm pulsed mode-locked laser. The device is designed primarily for pulsed illumination. It has a 3-dB bandwidth of 13.2 MHz, total conversion efficiency of 57% at 2.07 µm, and a common-mode rejection ratio of 48 dB at 39.5 MHz. The detector begins to saturate at 1.8 mW with 9 dB of shot-noise clearance at 5 MHz. This demonstration enables the characterisation of megahertz-quantum optical behaviour in the 2 µm band and provides a guide of how to design a 2 µm homodyne detector for quantum applications.

DOI
10.1364/oe.450217

Related papers

Low Noise Balanced Homodyne Detector for Quantum Noise Measurement

Shubo Lang, Shicheng Zhang, Xiaolin Li +2 more

The research of quantum noise in the interaction of laser and atoms plays a critical role in quantum optical experiments. The measurement of quantum noise is mainly based on the balanced homodyne detection method. Here, we reported a balanced homodyne detector with low noise, high gain, and high common-mode rejection ratio (CMRR) at the wavelength of 795 nm. By optimizing the selection of components and printed circuit board (PCB) layout, a minimum electronic noise of −96.7 dBm is obtained. Over the range of 1 MHz to 5 MHz, we get a flat CMRR above 59 dB and a linear gain regime, which can enable a shot noise measurement with the laser power of$100~\mu \text{w}$. The developed detector can be used in quantum coherent experiments with a weak probe laser of power down to tens of microwatts.

IEEE Access•Jan 1, 2022•4 citations

20 MHz resonant photodetector for the homodyne measurement of picosecond pulsed squeezed light

Zhihao Li, Jun Liu, Fengjuan Guo +3 more

A high-performance resonant balanced homodyne detector is a key element for the measurement of picosecond pulsed squeezed light, which is an important quantum resource in quantum-enhanced microscopic imaging. In this paper, we design and demonstrate a resonant photodetector for homodyne measurement with a maximum signal-to-noise ratio of 22.42 dB at resonant frequency of 20 MHz. Using this detector to pulsed regime, a maximum signal-to-noise ratio at resonant frequency is 10.02 dB, where a 40 dB subtraction capability at 80 MHz repetition rate of pulsed laser is obtained. With this design, the quantum noise of picosecond pulsed squeezed light is measured and the best squeezing level −1.7 dB below the shot noise level is clearly observed at 20 MHz.

Optics Continuum•Feb 1, 2023•6 citations

A Low-Noise Hybrid-Integrated Balanced Homodyne Receiver with 2.5 GHz Bandwidth and 15 dB Quantum Shot Noise Clearance

Yihao Yang, Chao Zeng Cheng, Ruixuan Yang +5 more

The rapid development of continuous-variable quantum communication has driven an increasing demand for high-performance quantum signal processing modules. Among these, the balanced homodyne detector (BHD) has emerged as a leading solution for practical quantum state measurement due to its capability to provide complete quantum mechanical characterization. However, its performance is often constrained by limited bandwidth and high noise levels, primarily due to the reliance on bulk optical components and discrete receiver electronics. The dominant noise source in these systems typically stems from electronic noise, while imbalances in the optical path further degrade the signal-to-noise ratio (SNR) of the BHD. In this work, we present an adjustable integrated optical path to enhance the balance within the BHD system, along with a low-noise transimpedance amplifier (TIA) by employing optoelectronic co-design. Our design achieves a bandwidth of 2.5 GHz, an input-referred noise current of only 2 pA/√Hz in 180 nm CMOS technology, and a measured quantum shot noise clearance of 15 dB generated from a 700 μA photocurrent. This is the maximum quantum shot noise clearance at the same BHD photocurrent reported to date above the GHz bandwidth.

Micromachines•Dec 17, 2025•0 citations

High-speed time-domain balanced homodyne detector for nanosecond optical field applications

Shanna Du, Zongyang Li, Wenyuan Liu +2 more

We present a high-speed time-domain shot-noise-limited balanced homodyne detector that is suitable for the detection of the quantum states of nanosecond pulsed optical fields. The detector can detect the quantum noise of individual nanosecond optical pulses at a repetition rate of 40 MHz and achieve a signal-to-noise ratio of above 14.5 dB at a local oscillator power of 9.9×107 photons per pulse. The stability of the detector is characterized via an Allan variance measurement, and superior stability is observed. The detector is especially applicable in the fields of quantum optics and quantum information, where high-speed time-domain detection of nanosecond pulsed optical field quadratures is required.

Journal of the Optical Society of America B•Feb 1, 2018•19 citations

A 300-MHz Bandwidth Balanced Homodyne Detector for Continuous Variable Quantum Key Distribution

Duan Huang, Jian Fang, Chao Wang +2 more

In Gaussian-modulated coherent-state quantum key distribution, the measurement of quadratures of coherent states is performed by using a homodyne detector. However, conventional detectors usually suffer from narrow bands. We present a method to design a high-speed shot-noise-limited balanced homodyne detector. A 300-MHz bandwidth detector is experimentally tested and the level of shot noise is 14 dB higher than the electronic noise. The results show that a detector with this method is potential to design a GHz bandwidth detector for continuous variable quantum key distribution at a low level of ratio of shot noise to electronic noise.

Chinese Physics Letters•Nov 1, 2013•65 citations

A low-noise, high-SNR and large-dynamic-range balanced homodyne detector for broadband squeezed light measurement

Jinrong Wang, Shuange Wu, Liying Hou +3 more

Squeezing-based quantum metrology has been extensively applied in the field of precision measurement. Performance characteristics of squeezed light are obtained by a balanced homodyne detector. Here, we report a large dynamic range balanced homodyne detector with low-noise and high-signal-to-noise-ratio (SNR) for broadband squeezed light measurement. We perform a comprehensive theoretical analysis of the SNR in a wide bandwidth and experimentally analyze the important printed circuit board (PCB) layout and electronic components. Consequently, in the 100 MHz frequency band, the SNR and common mode rejection ratio (CMRR) rise over 12.6 dB and 55 dB, respectively, and the electronic noise is suppressed below -90 dB. The directly observed squeezing level at 1550 nm with the specified detector is 11.8 dB at 2 MHz and 3.1 dB at 100 MHz.

Results in Physics•Jan 18, 2024•5 citations
Characterising quantum states of light in the 2 µm band requires high-performance shot-noise limited detectors. Here, we present the characterisation of a homodyne detector that we use to observe vacuum shot-noise via homodyne measurement with a 2.07 µm pulsed mode-locked laser. The device is designed primarily for pulsed illumination. It has a 3-dB bandwidth of 13.2 MHz, total conversion efficiency of 57% at 2.07 µm, and a common-mode rejection ratio of 48 dB at 39.5 MHz. The detector begins to saturate at 1.8 mW with 9 dB of shot-noise clearance at 5 MHz. This demonstration enables the characterisation of megahertz-quantum optical behaviour in the 2 µm band and provides a guide of how to design a 2 µm homodyne detector for quantum applications.
The research of quantum noise in the interaction of laser and atoms plays a critical role in quantum optical experiments. The measurement of quantum noise is mainly based on the balanced homodyne detection method. Here, we reported a balanced homodyne detector with low noise, high gain, and high common-mode rejection ratio (CMRR) at the wavelength of 795 nm. By optimizing the selection of components and printed circuit board (PCB) layout, a minimum electronic noise of −96.7 dBm is obtained. Over the range of 1 MHz to 5 MHz, we get a flat CMRR above 59 dB and a linear gain regime, which can enable a shot noise measurement with the laser power of100 μw100~\mu \text{w}100 μw. The developed detector can be used in quantum coherent experiments with a weak probe laser of power down to tens of microwatts.
A high-performance resonant balanced homodyne detector is a key element for the measurement of picosecond pulsed squeezed light, which is an important quantum resource in quantum-enhanced microscopic imaging. In this paper, we design and demonstrate a resonant photodetector for homodyne measurement with a maximum signal-to-noise ratio of 22.42 dB at resonant frequency of 20 MHz. Using this detector to pulsed regime, a maximum signal-to-noise ratio at resonant frequency is 10.02 dB, where a 40 dB subtraction capability at 80 MHz repetition rate of pulsed laser is obtained. With this design, the quantum noise of picosecond pulsed squeezed light is measured and the best squeezing level −1.7 dB below the shot noise level is clearly observed at 20 MHz.
The rapid development of continuous-variable quantum communication has driven an increasing demand for high-performance quantum signal processing modules. Among these, the balanced homodyne detector (BHD) has emerged as a leading solution for practical quantum state measurement due to its capability to provide complete quantum mechanical characterization. However, its performance is often constrained by limited bandwidth and high noise levels, primarily due to the reliance on bulk optical components and discrete receiver electronics. The dominant noise source in these systems typically stems from electronic noise, while imbalances in the optical path further degrade the signal-to-noise ratio (SNR) of the BHD. In this work, we present an adjustable integrated optical path to enhance the balance within the BHD system, along with a low-noise transimpedance amplifier (TIA) by employing optoelectronic co-design. Our design achieves a bandwidth of 2.5 GHz, an input-referred noise current of only 2 pA/√Hz in 180 nm CMOS technology, and a measured quantum shot noise clearance of 15 dB generated from a 700 μA photocurrent. This is the maximum quantum shot noise clearance at the same BHD photocurrent reported to date above the GHz bandwidth.
We present a high-speed time-domain shot-noise-limited balanced homodyne detector that is suitable for the detection of the quantum states of nanosecond pulsed optical fields. The detector can detect the quantum noise of individual nanosecond optical pulses at a repetition rate of 40 MHz and achieve a signal-to-noise ratio of above 14.5 dB at a local oscillator power of 9.9×107 photons per pulse. The stability of the detector is characterized via an Allan variance measurement, and superior stability is observed. The detector is especially applicable in the fields of quantum optics and quantum information, where high-speed time-domain detection of nanosecond pulsed optical field quadratures is required.
In Gaussian-modulated coherent-state quantum key distribution, the measurement of quadratures of coherent states is performed by using a homodyne detector. However, conventional detectors usually suffer from narrow bands. We present a method to design a high-speed shot-noise-limited balanced homodyne detector. A 300-MHz bandwidth detector is experimentally tested and the level of shot noise is 14 dB higher than the electronic noise. The results show that a detector with this method is potential to design a GHz bandwidth detector for continuous variable quantum key distribution at a low level of ratio of shot noise to electronic noise.
Squeezing-based quantum metrology has been extensively applied in the field of precision measurement. Performance characteristics of squeezed light are obtained by a balanced homodyne detector. Here, we report a large dynamic range balanced homodyne detector with low-noise and high-signal-to-noise-ratio (SNR) for broadband squeezed light measurement. We perform a comprehensive theoretical analysis of the SNR in a wide bandwidth and experimentally analyze the important printed circuit board (PCB) layout and electronic components. Consequently, in the 100 MHz frequency band, the SNR and common mode rejection ratio (CMRR) rise over 12.6 dB and 55 dB, respectively, and the electronic noise is suppressed below -90 dB. The directly observed squeezing level at 1550 nm with the specified detector is 11.8 dB at 2 MHz and 3.1 dB at 100 MHz.