Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Continuum

20 MHz resonant photodetector for the homodyne measurement of picosecond pulsed squeezed light

Zhihao Li, Jun Liu, Fengjuan Guo, Lujie Zhao, Zhongzhong Qin, Rong Ma

Published Feb 1, 2023• 6 citations
Publisher

Abstract

A high-performance resonant balanced homodyne detector is a key element for the measurement of picosecond pulsed squeezed light, which is an important quantum resource in quantum-enhanced microscopic imaging. In this paper, we design and demonstrate a resonant photodetector for homodyne measurement with a maximum signal-to-noise ratio of 22.42 dB at resonant frequency of 20 MHz. Using this detector to pulsed regime, a maximum signal-to-noise ratio at resonant frequency is 10.02 dB, where a 40 dB subtraction capability at 80 MHz repetition rate of pulsed laser is obtained. With this design, the quantum noise of picosecond pulsed squeezed light is measured and the best squeezing level −1.7 dB below the shot noise level is clearly observed at 20 MHz.

DOI
10.1364/optcon.481271

Related papers

A high-SNR resonant balanced photodetector with LC notch filter for the pulsed light

Rong Ma, Wen Zhang, Fengjuan Guo +3 more

The pulsed squeezed state plays a pivotal role in quantum information processing and precision measurement. In the detection of the pulsed squeezed state, the high noise power at its repetition rate prevents the achievement of a high signal-to-noise ratio (SNR). Therefore, a high-SNR detector that can suppress the high noise power of the repetition rate of pulsed light is very crucial. In this paper, we present a high-SNR resonant balanced photodetector that filters out the noise power of the repetition rate by introducing an LC series notch filter. A 24.37 dB attenuation is obtained at the 80 MHz repetition rate by finely adjusting the capacitance of the LC series notch filter. Consequently, the photodetector's maximum SNR is improved to 19.60 dB, which is 5 dB higher than previous studies. Our work provides a key detection tool for the measurement of the pulsed squeezed state.

Review of Scientific Instruments•Dec 1, 2025•0 citations

A low-noise, high-SNR and large-dynamic-range balanced homodyne detector for broadband squeezed light measurement

Jinrong Wang, Shuange Wu, Liying Hou +3 more

Squeezing-based quantum metrology has been extensively applied in the field of precision measurement. Performance characteristics of squeezed light are obtained by a balanced homodyne detector. Here, we report a large dynamic range balanced homodyne detector with low-noise and high-signal-to-noise-ratio (SNR) for broadband squeezed light measurement. We perform a comprehensive theoretical analysis of the SNR in a wide bandwidth and experimentally analyze the important printed circuit board (PCB) layout and electronic components. Consequently, in the 100 MHz frequency band, the SNR and common mode rejection ratio (CMRR) rise over 12.6 dB and 55 dB, respectively, and the electronic noise is suppressed below -90 dB. The directly observed squeezing level at 1550 nm with the specified detector is 11.8 dB at 2 MHz and 3.1 dB at 100 MHz.

Results in Physics•Jan 18, 2024•5 citations

A Simple and Robust Balanced Homodyne Detector for High-Repetition-Rate Pulsed Sources

Samuele Altilia, Edoardo Suerra, Pietro Puppi +3 more

We design and experimentally characterize a balanced homodyne detector optimized for high-repetition-rate (100 MHz) pulsed optical sources. Unlike conventional transimpedance-amplifier architectures, which suffer from nonlinearities and dynamic instabilities with ultrashort pulses, our approach allows to directly amplify the photocurrent extracted at the common photodiode node without feedback loops. A theoretical model describing the detector response, noise, and pulse-to-pulse correlations is developed, providing quantitative predictions for the signal variance, signal-to-noise ratio (SNR), and inter-pulse correlations. Implemented with two matched InGaAs photodiodes illuminated by a 1030 nm mode-locked laser at 100 MHz, the detector exhibits excellent linearity and shot-noise-limited scaling of the signal variance with optical power. Optimizing the temporal integration window yields a maximum SNR of about 14 dB, while correlation measurements confirm negligible inter-pulse correlations. These results demonstrate that the proposed architecture offers a robust and simple solution for high-speed pulsed homodyne detection, suitable for quantum optics and continuous-variable quantum information applications.

physics.opticsCross-listedarXiv:2604.06994•Apr 9, 2026•0 citations

500 MHz resonant photodetector for high-quantum-efficiency, low-noise homodyne measurement

Takahiro Serikawa, Akira Furusawa

We design and demonstrate a resonant-type differential photodetector for a low-noise quantum homodyne measurement at 500 MHz optical sideband with 17 MHz of bandwidth. By using a microwave monolithic amplifier and a discrete voltage buffer circuit, a low-noise voltage amplifier is realized and applied to our detector. 12 dB of signal-to-noise ratio of the shot noise to the electric noise is obtained with 5 mW of a continuous-wave local oscillator. We analyze the frequency response and the noise characteristics of a resonant photodetector, and the theoretical model agrees with the shot noise measurement.

arXiv:1803.06462•Review of Scientific Instruments•Jun 1, 2018•24 citations

A highly efficient photodetector for squeezed light measurement in the gigahertz range

D. M. Wilken, J. Junker, M. Heurs

Squeezed light plays a crucial role in state-of-the-art quantum metrology and quantum information experiments. There is significant interest in utilizing squeezed states at high MHz and GHz frequencies. However, past efforts to build suitable photodetectors at these frequencies have yet to yield the required high quantum efficiency. Here, we present the development of a high-frequency balanced photodetector with near-unity quantum efficiency, realized with off-the-shelf components. The detector operates in balanced mode up to approximately 500 MHz, above which the differential frequency response limits its performance. To obtain high sensitivity above 500 MHz, the detector can be efficiently used in an unbalanced homodyne detection scheme. We employ our detector in this unbalanced mode to measure a squeezing comb up to 6.4 GHz, achieving a squeezing level of up to 10.7 dB. By sharing our experience, specifically in identifying the unequal frequency response as a limiting factor, we aim to enable and advance further developments in the field.

Applied Physics Letters•Oct 6, 2025•0 citations

A highly efficient photodetector for squeezed light measurement in the gigahertz range

Dennis Wilken, J. Junker, M. Heurs

Squeezed light plays a crucial role in state-of-the-art quantum metrology and quantum information experiments. There is significant interest in utilizing squeezed states at high MHz and GHz frequencies. However, past efforts to build suitable photodetectors at these frequencies have yet to yield the required high quantum efficiency. Here, we present the development of a high-frequency balanced photodetector with near-unity quantum efficiency, realized with off-the-shelf components. The detector operates in balanced mode up to approximately 500 MHz, above which the differential frequency response limits its performance. To obtain high sensitivity above 500 MHz, the detector can be efficiently used in an unbalanced homodyne detection scheme. We employ our detector in this unbalanced mode to measure a squeezing comb up to 6.4 GHz, achieving a squeezing level of up to 10.7 dB. By sharing our experience, specifically in identifying the unequal frequency response as a limiting factor, we aim to enable and advance further developments in the field.

Applied Physics Letters•Jan 1, 2025•0 citations
A high-performance resonant balanced homodyne detector is a key element for the measurement of picosecond pulsed squeezed light, which is an important quantum resource in quantum-enhanced microscopic imaging. In this paper, we design and demonstrate a resonant photodetector for homodyne measurement with a maximum signal-to-noise ratio of 22.42 dB at resonant frequency of 20 MHz. Using this detector to pulsed regime, a maximum signal-to-noise ratio at resonant frequency is 10.02 dB, where a 40 dB subtraction capability at 80 MHz repetition rate of pulsed laser is obtained. With this design, the quantum noise of picosecond pulsed squeezed light is measured and the best squeezing level −1.7 dB below the shot noise level is clearly observed at 20 MHz.
The pulsed squeezed state plays a pivotal role in quantum information processing and precision measurement. In the detection of the pulsed squeezed state, the high noise power at its repetition rate prevents the achievement of a high signal-to-noise ratio (SNR). Therefore, a high-SNR detector that can suppress the high noise power of the repetition rate of pulsed light is very crucial. In this paper, we present a high-SNR resonant balanced photodetector that filters out the noise power of the repetition rate by introducing an LC series notch filter. A 24.37 dB attenuation is obtained at the 80 MHz repetition rate by finely adjusting the capacitance of the LC series notch filter. Consequently, the photodetector's maximum SNR is improved to 19.60 dB, which is 5 dB higher than previous studies. Our work provides a key detection tool for the measurement of the pulsed squeezed state.
Squeezing-based quantum metrology has been extensively applied in the field of precision measurement. Performance characteristics of squeezed light are obtained by a balanced homodyne detector. Here, we report a large dynamic range balanced homodyne detector with low-noise and high-signal-to-noise-ratio (SNR) for broadband squeezed light measurement. We perform a comprehensive theoretical analysis of the SNR in a wide bandwidth and experimentally analyze the important printed circuit board (PCB) layout and electronic components. Consequently, in the 100 MHz frequency band, the SNR and common mode rejection ratio (CMRR) rise over 12.6 dB and 55 dB, respectively, and the electronic noise is suppressed below -90 dB. The directly observed squeezing level at 1550 nm with the specified detector is 11.8 dB at 2 MHz and 3.1 dB at 100 MHz.
We design and experimentally characterize a balanced homodyne detector optimized for high-repetition-rate (100 MHz) pulsed optical sources. Unlike conventional transimpedance-amplifier architectures, which suffer from nonlinearities and dynamic instabilities with ultrashort pulses, our approach allows to directly amplify the photocurrent extracted at the common photodiode node without feedback loops. A theoretical model describing the detector response, noise, and pulse-to-pulse correlations is developed, providing quantitative predictions for the signal variance, signal-to-noise ratio (SNR), and inter-pulse correlations. Implemented with two matched InGaAs photodiodes illuminated by a 1030 nm mode-locked laser at 100 MHz, the detector exhibits excellent linearity and shot-noise-limited scaling of the signal variance with optical power. Optimizing the temporal integration window yields a maximum SNR of about 14 dB, while correlation measurements confirm negligible inter-pulse correlations. These results demonstrate that the proposed architecture offers a robust and simple solution for high-speed pulsed homodyne detection, suitable for quantum optics and continuous-variable quantum information applications.
We design and demonstrate a resonant-type differential photodetector for a low-noise quantum homodyne measurement at 500 MHz optical sideband with 17 MHz of bandwidth. By using a microwave monolithic amplifier and a discrete voltage buffer circuit, a low-noise voltage amplifier is realized and applied to our detector. 12 dB of signal-to-noise ratio of the shot noise to the electric noise is obtained with 5 mW of a continuous-wave local oscillator. We analyze the frequency response and the noise characteristics of a resonant photodetector, and the theoretical model agrees with the shot noise measurement.
Squeezed light plays a crucial role in state-of-the-art quantum metrology and quantum information experiments. There is significant interest in utilizing squeezed states at high MHz and GHz frequencies. However, past efforts to build suitable photodetectors at these frequencies have yet to yield the required high quantum efficiency. Here, we present the development of a high-frequency balanced photodetector with near-unity quantum efficiency, realized with off-the-shelf components. The detector operates in balanced mode up to approximately 500 MHz, above which the differential frequency response limits its performance. To obtain high sensitivity above 500 MHz, the detector can be efficiently used in an unbalanced homodyne detection scheme. We employ our detector in this unbalanced mode to measure a squeezing comb up to 6.4 GHz, achieving a squeezing level of up to 10.7 dB. By sharing our experience, specifically in identifying the unequal frequency response as a limiting factor, we aim to enable and advance further developments in the field.
Squeezed light plays a crucial role in state-of-the-art quantum metrology and quantum information experiments. There is significant interest in utilizing squeezed states at high MHz and GHz frequencies. However, past efforts to build suitable photodetectors at these frequencies have yet to yield the required high quantum efficiency. Here, we present the development of a high-frequency balanced photodetector with near-unity quantum efficiency, realized with off-the-shelf components. The detector operates in balanced mode up to approximately 500 MHz, above which the differential frequency response limits its performance. To obtain high sensitivity above 500 MHz, the detector can be efficiently used in an unbalanced homodyne detection scheme. We employ our detector in this unbalanced mode to measure a squeezing comb up to 6.4 GHz, achieving a squeezing level of up to 10.7 dB. By sharing our experience, specifically in identifying the unequal frequency response as a limiting factor, we aim to enable and advance further developments in the field.