Review of Scientific Instruments

A high-SNR resonant balanced photodetector with LC notch filter for the pulsed light

Rong Ma, Wen Zhang, Fengjuan Guo, Jun Liu, Meihong Wang, Xiaolong Su

Published Dec 1, 2025• 0 citations
Publisher

Abstract

The pulsed squeezed state plays a pivotal role in quantum information processing and precision measurement. In the detection of the pulsed squeezed state, the high noise power at its repetition rate prevents the achievement of a high signal-to-noise ratio (SNR). Therefore, a high-SNR detector that can suppress the high noise power of the repetition rate of pulsed light is very crucial. In this paper, we present a high-SNR resonant balanced photodetector that filters out the noise power of the repetition rate by introducing an LC series notch filter. A 24.37 dB attenuation is obtained at the 80 MHz repetition rate by finely adjusting the capacitance of the LC series notch filter. Consequently, the photodetector's maximum SNR is improved to 19.60 dB, which is 5 dB higher than previous studies. Our work provides a key detection tool for the measurement of the pulsed squeezed state.

DOI
10.1063/5.0284345

Related papers

20 MHz resonant photodetector for the homodyne measurement of picosecond pulsed squeezed light

Zhihao Li, Jun Liu, Fengjuan Guo +3 more

A high-performance resonant balanced homodyne detector is a key element for the measurement of picosecond pulsed squeezed light, which is an important quantum resource in quantum-enhanced microscopic imaging. In this paper, we design and demonstrate a resonant photodetector for homodyne measurement with a maximum signal-to-noise ratio of 22.42 dB at resonant frequency of 20 MHz. Using this detector to pulsed regime, a maximum signal-to-noise ratio at resonant frequency is 10.02 dB, where a 40 dB subtraction capability at 80 MHz repetition rate of pulsed laser is obtained. With this design, the quantum noise of picosecond pulsed squeezed light is measured and the best squeezing level −1.7 dB below the shot noise level is clearly observed at 20 MHz.

Optics Continuum•Feb 1, 2023•6 citations

Stabilization improvement of the squeezed optical fields using a high signal-to-noise ratio bootstrap photodetector

Xiaoli Wang, Liang Wu, Shaocong Liang +6 more

High-precision cavity locking is crucial for squeezing optical fields. Here, a bootstrapped low-noise photodetector is utilized in the generation process of the squeezed state of light. This process is based on a combination of a modified trans-impedance amplifier (TIA) circuit and a two-stage bootstrap amplifier circuit. This not only achieves high-precision and long-term stable locking of the optical cavity, but it also improves the degree to which the light field is squeezed. The experiment results show that the detector has a high signal-to-noise ratio (SNR) of 26.7 dB at the analysis frequency of 3 MHz when measuring the shot noise with an injection optical power of 800 µW, and the equivalent optical power noise level is lower than 2.4 pW/Hz in the frequency range of 1-30 MHz. Moreover, the squeezing degree of the quadrature amplitude squeezed state light field can be improved by more than 34.9% when the detector is used for optical cavity locking. The photodetector is useful in continuous variable (CV) quantum information research.

Optics Express•Dec 5, 2022•5 citations

A low-noise, high-SNR and large-dynamic-range balanced homodyne detector for broadband squeezed light measurement

Jinrong Wang, Shuange Wu, Liying Hou +3 more

Squeezing-based quantum metrology has been extensively applied in the field of precision measurement. Performance characteristics of squeezed light are obtained by a balanced homodyne detector. Here, we report a large dynamic range balanced homodyne detector with low-noise and high-signal-to-noise-ratio (SNR) for broadband squeezed light measurement. We perform a comprehensive theoretical analysis of the SNR in a wide bandwidth and experimentally analyze the important printed circuit board (PCB) layout and electronic components. Consequently, in the 100 MHz frequency band, the SNR and common mode rejection ratio (CMRR) rise over 12.6 dB and 55 dB, respectively, and the electronic noise is suppressed below -90 dB. The directly observed squeezing level at 1550 nm with the specified detector is 11.8 dB at 2 MHz and 3.1 dB at 100 MHz.

Results in Physics•Jan 18, 2024•5 citations

A highly efficient photodetector for squeezed light measurement in the gigahertz range

D. M. Wilken, J. Junker, M. Heurs

Squeezed light plays a crucial role in state-of-the-art quantum metrology and quantum information experiments. There is significant interest in utilizing squeezed states at high MHz and GHz frequencies. However, past efforts to build suitable photodetectors at these frequencies have yet to yield the required high quantum efficiency. Here, we present the development of a high-frequency balanced photodetector with near-unity quantum efficiency, realized with off-the-shelf components. The detector operates in balanced mode up to approximately 500 MHz, above which the differential frequency response limits its performance. To obtain high sensitivity above 500 MHz, the detector can be efficiently used in an unbalanced homodyne detection scheme. We employ our detector in this unbalanced mode to measure a squeezing comb up to 6.4 GHz, achieving a squeezing level of up to 10.7 dB. By sharing our experience, specifically in identifying the unequal frequency response as a limiting factor, we aim to enable and advance further developments in the field.

Applied Physics Letters•Oct 6, 2025•0 citations

A low-noise, high-SNR balanced homodyne detector for the bright squeezed state measurement in 1–100 kHz range*

JinRong Wang, Qing-Wei Wang, Long Tian +2 more

We report a low-noise, high-signal-to-noise-ratio (SNR) balanced homodyne detector based on the standard transimpedance amplifier circuit and the inductance and capacitance combination for the measurement of the bright squeezed state in the range from 1 kHz to 100 kHz. A capacitance is mounted at the input end of the AC branch to prevent the DC photocurrent from entering the AC branch and avoid AC branch saturation. By adding a switch at the DC branch, the DC branch can be flexibly turned on and off on different occasions. When the switch is on, the DC output provides a monitor signal for laser beam alignment. When the switch is off, the electronic noise of the AC branch is greatly reduced at audio-frequency band due to immunity to the impedance of the DC branch, hence the SNR of the AC branch is significantly improved. As a result, the electronic noise of the AC branch is close to −125 dBm, and the maximum SNR of the AC branch is 48 dB with the incident power of 8 mW in the range from 1 kHz to 100 kHz. The developed photodetector paves a path for measuring the bright squeezed state at audio-frequency band.

Chinese Physics B•Jan 7, 2020•14 citations

A Simple and Robust Balanced Homodyne Detector for High-Repetition-Rate Pulsed Sources

Samuele Altilia, Edoardo Suerra, Pietro Puppi +3 more

We design and experimentally characterize a balanced homodyne detector optimized for high-repetition-rate (100 MHz) pulsed optical sources. Unlike conventional transimpedance-amplifier architectures, which suffer from nonlinearities and dynamic instabilities with ultrashort pulses, our approach allows to directly amplify the photocurrent extracted at the common photodiode node without feedback loops. A theoretical model describing the detector response, noise, and pulse-to-pulse correlations is developed, providing quantitative predictions for the signal variance, signal-to-noise ratio (SNR), and inter-pulse correlations. Implemented with two matched InGaAs photodiodes illuminated by a 1030 nm mode-locked laser at 100 MHz, the detector exhibits excellent linearity and shot-noise-limited scaling of the signal variance with optical power. Optimizing the temporal integration window yields a maximum SNR of about 14 dB, while correlation measurements confirm negligible inter-pulse correlations. These results demonstrate that the proposed architecture offers a robust and simple solution for high-speed pulsed homodyne detection, suitable for quantum optics and continuous-variable quantum information applications.

physics.opticsCross-listedarXiv:2604.06994•Apr 9, 2026•0 citations
The pulsed squeezed state plays a pivotal role in quantum information processing and precision measurement. In the detection of the pulsed squeezed state, the high noise power at its repetition rate prevents the achievement of a high signal-to-noise ratio (SNR). Therefore, a high-SNR detector that can suppress the high noise power of the repetition rate of pulsed light is very crucial. In this paper, we present a high-SNR resonant balanced photodetector that filters out the noise power of the repetition rate by introducing an LC series notch filter. A 24.37 dB attenuation is obtained at the 80 MHz repetition rate by finely adjusting the capacitance of the LC series notch filter. Consequently, the photodetector's maximum SNR is improved to 19.60 dB, which is 5 dB higher than previous studies. Our work provides a key detection tool for the measurement of the pulsed squeezed state.
A high-performance resonant balanced homodyne detector is a key element for the measurement of picosecond pulsed squeezed light, which is an important quantum resource in quantum-enhanced microscopic imaging. In this paper, we design and demonstrate a resonant photodetector for homodyne measurement with a maximum signal-to-noise ratio of 22.42 dB at resonant frequency of 20 MHz. Using this detector to pulsed regime, a maximum signal-to-noise ratio at resonant frequency is 10.02 dB, where a 40 dB subtraction capability at 80 MHz repetition rate of pulsed laser is obtained. With this design, the quantum noise of picosecond pulsed squeezed light is measured and the best squeezing level −1.7 dB below the shot noise level is clearly observed at 20 MHz.
High-precision cavity locking is crucial for squeezing optical fields. Here, a bootstrapped low-noise photodetector is utilized in the generation process of the squeezed state of light. This process is based on a combination of a modified trans-impedance amplifier (TIA) circuit and a two-stage bootstrap amplifier circuit. This not only achieves high-precision and long-term stable locking of the optical cavity, but it also improves the degree to which the light field is squeezed. The experiment results show that the detector has a high signal-to-noise ratio (SNR) of 26.7 dB at the analysis frequency of 3 MHz when measuring the shot noise with an injection optical power of 800 µW, and the equivalent optical power noise level is lower than 2.4 pW/Hz in the frequency range of 1-30 MHz. Moreover, the squeezing degree of the quadrature amplitude squeezed state light field can be improved by more than 34.9% when the detector is used for optical cavity locking. The photodetector is useful in continuous variable (CV) quantum information research.
Squeezing-based quantum metrology has been extensively applied in the field of precision measurement. Performance characteristics of squeezed light are obtained by a balanced homodyne detector. Here, we report a large dynamic range balanced homodyne detector with low-noise and high-signal-to-noise-ratio (SNR) for broadband squeezed light measurement. We perform a comprehensive theoretical analysis of the SNR in a wide bandwidth and experimentally analyze the important printed circuit board (PCB) layout and electronic components. Consequently, in the 100 MHz frequency band, the SNR and common mode rejection ratio (CMRR) rise over 12.6 dB and 55 dB, respectively, and the electronic noise is suppressed below -90 dB. The directly observed squeezing level at 1550 nm with the specified detector is 11.8 dB at 2 MHz and 3.1 dB at 100 MHz.
Squeezed light plays a crucial role in state-of-the-art quantum metrology and quantum information experiments. There is significant interest in utilizing squeezed states at high MHz and GHz frequencies. However, past efforts to build suitable photodetectors at these frequencies have yet to yield the required high quantum efficiency. Here, we present the development of a high-frequency balanced photodetector with near-unity quantum efficiency, realized with off-the-shelf components. The detector operates in balanced mode up to approximately 500 MHz, above which the differential frequency response limits its performance. To obtain high sensitivity above 500 MHz, the detector can be efficiently used in an unbalanced homodyne detection scheme. We employ our detector in this unbalanced mode to measure a squeezing comb up to 6.4 GHz, achieving a squeezing level of up to 10.7 dB. By sharing our experience, specifically in identifying the unequal frequency response as a limiting factor, we aim to enable and advance further developments in the field.
We report a low-noise, high-signal-to-noise-ratio (SNR) balanced homodyne detector based on the standard transimpedance amplifier circuit and the inductance and capacitance combination for the measurement of the bright squeezed state in the range from 1 kHz to 100 kHz. A capacitance is mounted at the input end of the AC branch to prevent the DC photocurrent from entering the AC branch and avoid AC branch saturation. By adding a switch at the DC branch, the DC branch can be flexibly turned on and off on different occasions. When the switch is on, the DC output provides a monitor signal for laser beam alignment. When the switch is off, the electronic noise of the AC branch is greatly reduced at audio-frequency band due to immunity to the impedance of the DC branch, hence the SNR of the AC branch is significantly improved. As a result, the electronic noise of the AC branch is close to −125 dBm, and the maximum SNR of the AC branch is 48 dB with the incident power of 8 mW in the range from 1 kHz to 100 kHz. The developed photodetector paves a path for measuring the bright squeezed state at audio-frequency band.
We design and experimentally characterize a balanced homodyne detector optimized for high-repetition-rate (100 MHz) pulsed optical sources. Unlike conventional transimpedance-amplifier architectures, which suffer from nonlinearities and dynamic instabilities with ultrashort pulses, our approach allows to directly amplify the photocurrent extracted at the common photodiode node without feedback loops. A theoretical model describing the detector response, noise, and pulse-to-pulse correlations is developed, providing quantitative predictions for the signal variance, signal-to-noise ratio (SNR), and inter-pulse correlations. Implemented with two matched InGaAs photodiodes illuminated by a 1030 nm mode-locked laser at 100 MHz, the detector exhibits excellent linearity and shot-noise-limited scaling of the signal variance with optical power. Optimizing the temporal integration window yields a maximum SNR of about 14 dB, while correlation measurements confirm negligible inter-pulse correlations. These results demonstrate that the proposed architecture offers a robust and simple solution for high-speed pulsed homodyne detection, suitable for quantum optics and continuous-variable quantum information applications.