arXiv:2604.06994

A Simple and Robust Balanced Homodyne Detector for High-Repetition-Rate Pulsed Sources

Samuele Altilia, Edoardo Suerra, Pietro Puppi, Sebastiano Corli, Enrico Prati, Simone Cialdi

physics.opticsquant-phSubmitted Apr 8, 2026• Announced Apr 9, 2026• 0 citations
arXivHTMLPDF

Abstract

We design and experimentally characterize a balanced homodyne detector optimized for high-repetition-rate (100 MHz) pulsed optical sources. Unlike conventional transimpedance-amplifier architectures, which suffer from nonlinearities and dynamic instabilities with ultrashort pulses, our approach allows to directly amplify the photocurrent extracted at the common photodiode node without feedback loops. A theoretical model describing the detector response, noise, and pulse-to-pulse correlations is developed, providing quantitative predictions for the signal variance, signal-to-noise ratio (SNR), and inter-pulse correlations. Implemented with two matched InGaAs photodiodes illuminated by a 1030 nm mode-locked laser at 100 MHz, the detector exhibits excellent linearity and shot-noise-limited scaling of the signal variance with optical power. Optimizing the temporal integration window yields a maximum SNR of about 14 dB, while correlation measurements confirm negligible inter-pulse correlations. These results demonstrate that the proposed architecture offers a robust and simple solution for high-speed pulsed homodyne detection, suitable for quantum optics and continuous-variable quantum information applications.

Related papers

High-speed time-domain balanced homodyne detector for nanosecond optical field applications

Shanna Du, Zongyang Li, Wenyuan Liu +2 more

We present a high-speed time-domain shot-noise-limited balanced homodyne detector that is suitable for the detection of the quantum states of nanosecond pulsed optical fields. The detector can detect the quantum noise of individual nanosecond optical pulses at a repetition rate of 40 MHz and achieve a signal-to-noise ratio of above 14.5 dB at a local oscillator power of 9.9×107 photons per pulse. The stability of the detector is characterized via an Allan variance measurement, and superior stability is observed. The detector is especially applicable in the fields of quantum optics and quantum information, where high-speed time-domain detection of nanosecond pulsed optical field quadratures is required.

Journal of the Optical Society of America B•Feb 1, 2018•19 citations

Ultrastable Fiber-Based Time-Domain Balanced Homodyne Detector for Quantum Communication

Xuyang Wang, Zengliang Bai, Peng-Yan Du +2 more

We present an ultrastable fiber-based time-domain balanced homodyne detector which can be used for precise characterization of pulsed quantum light fields. A variable optical attenuator based on bending the fiber is utilized to compensate for the different quantum efficiencies of the photodiodes precisely, and a common mode rejection ratio of above 76 dB is achieved. The detector has a gain of 3.2 μV per photon and a signal-to-noise ratio above 20 dB. Optical pulses with repetition rates up to 2 MHz can be measured with a detection efficiency of 66%. The stability of the detector is analyzed via an Allan variance measurement and the detector exhibits superior stability which enables a 100-s window for measurement without calibration.

Chinese Physics Letters•Dec 1, 2012•15 citations

Integrated balanced homodyne detector using CMOS capacitive-feedback TIA for quantum measurements

Sarah Bastiaens, Cedric Bruynsteen, Simone Cammarata +5 more

A low-noise, high-speed balanced homodyne detector is demonstrated, combining a capacitive-feedback transimpedance amplifier implemented in 28 nm CMOS with a custom photonic integrated circuit fabricated in imec's iSiPP200 silicon photonics platform. The receiver achieves a 3-dB bandwidth of 7.6 GHz, a maximum shot noise clearance of 27 dB, a shot noise-limited bandwidth of 13.7 GHz and a common-mode rejection ratio up to 54.8 dB. These results demonstrate the suitability of CMOS capacitive-feedback transimpedance amplifiers for demanding quantum and coherent sensing optical applications, including continuous-variable quantum key distribution, quantum random number generation, and optical coherence tomography.

quant-pharXiv:2609.37671•Sep 30, 2026•0 citations

A Low-Noise Hybrid-Integrated Balanced Homodyne Receiver with 2.5 GHz Bandwidth and 15 dB Quantum Shot Noise Clearance

Yihao Yang, Chao Zeng Cheng, Ruixuan Yang +5 more

The rapid development of continuous-variable quantum communication has driven an increasing demand for high-performance quantum signal processing modules. Among these, the balanced homodyne detector (BHD) has emerged as a leading solution for practical quantum state measurement due to its capability to provide complete quantum mechanical characterization. However, its performance is often constrained by limited bandwidth and high noise levels, primarily due to the reliance on bulk optical components and discrete receiver electronics. The dominant noise source in these systems typically stems from electronic noise, while imbalances in the optical path further degrade the signal-to-noise ratio (SNR) of the BHD. In this work, we present an adjustable integrated optical path to enhance the balance within the BHD system, along with a low-noise transimpedance amplifier (TIA) by employing optoelectronic co-design. Our design achieves a bandwidth of 2.5 GHz, an input-referred noise current of only 2 pA/√Hz in 180 nm CMOS technology, and a measured quantum shot noise clearance of 15 dB generated from a 700 μA photocurrent. This is the maximum quantum shot noise clearance at the same BHD photocurrent reported to date above the GHz bandwidth.

Micromachines•Dec 17, 2025•0 citations

Integrated balanced homodyne photonic–electronic detector for beyond 20 GHz shot-noise-limited measurements

Cédric Bruynsteen, Michael Vanhoecke, Johan Bauwelinck +1 more

Optical homodyne detection is used in numerous quantum and classical applications that demand high levels of sensitivity. However, performance is typically limited due to the use of bulk optics and discrete receiver electronics. To address these performance issues, in this work we present a co-integrated balanced homodyne detector consisting of a silicon photonics optical front end and a custom integrated transimpedance amplifier designed in a 100 nm GaAs pHEMT technology. The high level of co-design and integration provides enhanced levels of stability, bandwidth, and noise performance. The presented detector shows a linear operation up to 28 dB quantum shot noise clearance and a high degree of common-mode rejection, at the same time achieving a shot-noise-limited bandwidth of more than 20 GHz. The high performance of the developed devices provide enhanced operation to many sensitive quantum applications such as continuous variable quantum key distribution, quantum random number generation, or high-speed quantum tomography.

Optica•Jul 23, 2021•90 citations

20 MHz resonant photodetector for the homodyne measurement of picosecond pulsed squeezed light

Zhihao Li, Jun Liu, Fengjuan Guo +3 more

A high-performance resonant balanced homodyne detector is a key element for the measurement of picosecond pulsed squeezed light, which is an important quantum resource in quantum-enhanced microscopic imaging. In this paper, we design and demonstrate a resonant photodetector for homodyne measurement with a maximum signal-to-noise ratio of 22.42 dB at resonant frequency of 20 MHz. Using this detector to pulsed regime, a maximum signal-to-noise ratio at resonant frequency is 10.02 dB, where a 40 dB subtraction capability at 80 MHz repetition rate of pulsed laser is obtained. With this design, the quantum noise of picosecond pulsed squeezed light is measured and the best squeezing level −1.7 dB below the shot noise level is clearly observed at 20 MHz.

Optics Continuum•Feb 1, 2023•6 citations
We design and experimentally characterize a balanced homodyne detector optimized for high-repetition-rate (100 MHz) pulsed optical sources. Unlike conventional transimpedance-amplifier architectures, which suffer from nonlinearities and dynamic instabilities with ultrashort pulses, our approach allows to directly amplify the photocurrent extracted at the common photodiode node without feedback loops. A theoretical model describing the detector response, noise, and pulse-to-pulse correlations is developed, providing quantitative predictions for the signal variance, signal-to-noise ratio (SNR), and inter-pulse correlations. Implemented with two matched InGaAs photodiodes illuminated by a 1030 nm mode-locked laser at 100 MHz, the detector exhibits excellent linearity and shot-noise-limited scaling of the signal variance with optical power. Optimizing the temporal integration window yields a maximum SNR of about 14 dB, while correlation measurements confirm negligible inter-pulse correlations. These results demonstrate that the proposed architecture offers a robust and simple solution for high-speed pulsed homodyne detection, suitable for quantum optics and continuous-variable quantum information applications.
We present a high-speed time-domain shot-noise-limited balanced homodyne detector that is suitable for the detection of the quantum states of nanosecond pulsed optical fields. The detector can detect the quantum noise of individual nanosecond optical pulses at a repetition rate of 40 MHz and achieve a signal-to-noise ratio of above 14.5 dB at a local oscillator power of 9.9×107 photons per pulse. The stability of the detector is characterized via an Allan variance measurement, and superior stability is observed. The detector is especially applicable in the fields of quantum optics and quantum information, where high-speed time-domain detection of nanosecond pulsed optical field quadratures is required.
We present an ultrastable fiber-based time-domain balanced homodyne detector which can be used for precise characterization of pulsed quantum light fields. A variable optical attenuator based on bending the fiber is utilized to compensate for the different quantum efficiencies of the photodiodes precisely, and a common mode rejection ratio of above 76 dB is achieved. The detector has a gain of 3.2 μV per photon and a signal-to-noise ratio above 20 dB. Optical pulses with repetition rates up to 2 MHz can be measured with a detection efficiency of 66%. The stability of the detector is analyzed via an Allan variance measurement and the detector exhibits superior stability which enables a 100-s window for measurement without calibration.
A low-noise, high-speed balanced homodyne detector is demonstrated, combining a capacitive-feedback transimpedance amplifier implemented in 28 nm CMOS with a custom photonic integrated circuit fabricated in imec's iSiPP200 silicon photonics platform. The receiver achieves a 3-dB bandwidth of 7.6 GHz, a maximum shot noise clearance of 27 dB, a shot noise-limited bandwidth of 13.7 GHz and a common-mode rejection ratio up to 54.8 dB. These results demonstrate the suitability of CMOS capacitive-feedback transimpedance amplifiers for demanding quantum and coherent sensing optical applications, including continuous-variable quantum key distribution, quantum random number generation, and optical coherence tomography.
The rapid development of continuous-variable quantum communication has driven an increasing demand for high-performance quantum signal processing modules. Among these, the balanced homodyne detector (BHD) has emerged as a leading solution for practical quantum state measurement due to its capability to provide complete quantum mechanical characterization. However, its performance is often constrained by limited bandwidth and high noise levels, primarily due to the reliance on bulk optical components and discrete receiver electronics. The dominant noise source in these systems typically stems from electronic noise, while imbalances in the optical path further degrade the signal-to-noise ratio (SNR) of the BHD. In this work, we present an adjustable integrated optical path to enhance the balance within the BHD system, along with a low-noise transimpedance amplifier (TIA) by employing optoelectronic co-design. Our design achieves a bandwidth of 2.5 GHz, an input-referred noise current of only 2 pA/√Hz in 180 nm CMOS technology, and a measured quantum shot noise clearance of 15 dB generated from a 700 μA photocurrent. This is the maximum quantum shot noise clearance at the same BHD photocurrent reported to date above the GHz bandwidth.
Optical homodyne detection is used in numerous quantum and classical applications that demand high levels of sensitivity. However, performance is typically limited due to the use of bulk optics and discrete receiver electronics. To address these performance issues, in this work we present a co-integrated balanced homodyne detector consisting of a silicon photonics optical front end and a custom integrated transimpedance amplifier designed in a 100 nm GaAs pHEMT technology. The high level of co-design and integration provides enhanced levels of stability, bandwidth, and noise performance. The presented detector shows a linear operation up to 28 dB quantum shot noise clearance and a high degree of common-mode rejection, at the same time achieving a shot-noise-limited bandwidth of more than 20 GHz. The high performance of the developed devices provide enhanced operation to many sensitive quantum applications such as continuous variable quantum key distribution, quantum random number generation, or high-speed quantum tomography.
A high-performance resonant balanced homodyne detector is a key element for the measurement of picosecond pulsed squeezed light, which is an important quantum resource in quantum-enhanced microscopic imaging. In this paper, we design and demonstrate a resonant photodetector for homodyne measurement with a maximum signal-to-noise ratio of 22.42 dB at resonant frequency of 20 MHz. Using this detector to pulsed regime, a maximum signal-to-noise ratio at resonant frequency is 10.02 dB, where a 40 dB subtraction capability at 80 MHz repetition rate of pulsed laser is obtained. With this design, the quantum noise of picosecond pulsed squeezed light is measured and the best squeezing level −1.7 dB below the shot noise level is clearly observed at 20 MHz.