Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2609.37671

Integrated balanced homodyne detector using CMOS capacitive-feedback TIA for quantum measurements

Sarah Bastiaens, Cedric Bruynsteen, Simone Cammarata, Axl Bomhals, Leandro da Silva, Michiel Van Osta, Johan Bauwelinck, Xin Yin

quant-phSubmitted Sep 29, 2026• Announced Sep 30, 2026• 0 citations
arXivHTMLPDF

Abstract

A low-noise, high-speed balanced homodyne detector is demonstrated, combining a capacitive-feedback transimpedance amplifier implemented in 28 nm CMOS with a custom photonic integrated circuit fabricated in imec's iSiPP200 silicon photonics platform. The receiver achieves a 3-dB bandwidth of 7.6 GHz, a maximum shot noise clearance of 27 dB, a shot noise-limited bandwidth of 13.7 GHz and a common-mode rejection ratio up to 54.8 dB. These results demonstrate the suitability of CMOS capacitive-feedback transimpedance amplifiers for demanding quantum and coherent sensing optical applications, including continuous-variable quantum key distribution, quantum random number generation, and optical coherence tomography.

Comments
This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may no longer be accessible

Related papers

Integrated balanced homodyne photonic–electronic detector for beyond 20 GHz shot-noise-limited measurements

Cédric Bruynsteen, Michael Vanhoecke, Johan Bauwelinck +1 more

Optical homodyne detection is used in numerous quantum and classical applications that demand high levels of sensitivity. However, performance is typically limited due to the use of bulk optics and discrete receiver electronics. To address these performance issues, in this work we present a co-integrated balanced homodyne detector consisting of a silicon photonics optical front end and a custom integrated transimpedance amplifier designed in a 100 nm GaAs pHEMT technology. The high level of co-design and integration provides enhanced levels of stability, bandwidth, and noise performance. The presented detector shows a linear operation up to 28 dB quantum shot noise clearance and a high degree of common-mode rejection, at the same time achieving a shot-noise-limited bandwidth of more than 20 GHz. The high performance of the developed devices provide enhanced operation to many sensitive quantum applications such as continuous variable quantum key distribution, quantum random number generation, or high-speed quantum tomography.

Optica•Jul 23, 2021•90 citations

A Low-Noise Hybrid-Integrated Balanced Homodyne Receiver with 2.5 GHz Bandwidth and 15 dB Quantum Shot Noise Clearance

Yihao Yang, Chao Zeng Cheng, Ruixuan Yang +5 more

The rapid development of continuous-variable quantum communication has driven an increasing demand for high-performance quantum signal processing modules. Among these, the balanced homodyne detector (BHD) has emerged as a leading solution for practical quantum state measurement due to its capability to provide complete quantum mechanical characterization. However, its performance is often constrained by limited bandwidth and high noise levels, primarily due to the reliance on bulk optical components and discrete receiver electronics. The dominant noise source in these systems typically stems from electronic noise, while imbalances in the optical path further degrade the signal-to-noise ratio (SNR) of the BHD. In this work, we present an adjustable integrated optical path to enhance the balance within the BHD system, along with a low-noise transimpedance amplifier (TIA) by employing optoelectronic co-design. Our design achieves a bandwidth of 2.5 GHz, an input-referred noise current of only 2 pA/√Hz in 180 nm CMOS technology, and a measured quantum shot noise clearance of 15 dB generated from a 700 μA photocurrent. This is the maximum quantum shot noise clearance at the same BHD photocurrent reported to date above the GHz bandwidth.

Micromachines•Dec 17, 2025•0 citations

Chip-Level GHz Capable Balanced Quantum Homodyne Receivers

Dinka Milovančev, Florian Honz, Nemanja Vokić +5 more

We present a design of balanced homodyne receivers suitable for ultra-low noise quantum applications such as continuous-variable quantum key distribution and quantum random number generation. For best noise and bandwidth performance a die-level low-parasitic photodiode together with a low-noise high-speed transimpedance amplifier are explored together with a planar lightwave circuit splitter chip serving as a photomixer. Bandwidths of 750 MHz and 2.6 GHz were accomplished while maintaining optimum noise performance, as evidenced by very high quantum-to-classical noise ratios of 26.8 and 18.6 dB, respectively. A common-mode rejection ratio of at least 40 dB was achieved for a frequency range of up to 1 GHz. Its application for continuous-variable quantum key distribution was evaluated by means of estimations under a strict untrusted receiver assumption, showing its potential for generating up to 43 Mbit/s secure-key rate over a reach of 10 km, whereas up to 100 Mbit/s could be supported at shorter reaches. Moreover, the high quantum-to-classical clearance values can enable high quality quantum random number generation at Gb/s rates. The multi-purpose operation of the designed balanced receivers for classical communications was examined showing reception sensitivities of −55.8 and −52.6 dBm at 500 Mbit/s and 1 Gbit/s quadrature phase shift keying transmission, respectively, using the 750 MHz receiver. The faster 2.6 GHz receiver enabled 10 Gbit/s duobinary transmission at −14.8 dBm sensitivity.

Journal of Lightwave Technology•Sep 30, 2022•9 citations

A Simple and Robust Balanced Homodyne Detector for High-Repetition-Rate Pulsed Sources

Samuele Altilia, Edoardo Suerra, Pietro Puppi +3 more

We design and experimentally characterize a balanced homodyne detector optimized for high-repetition-rate (100 MHz) pulsed optical sources. Unlike conventional transimpedance-amplifier architectures, which suffer from nonlinearities and dynamic instabilities with ultrashort pulses, our approach allows to directly amplify the photocurrent extracted at the common photodiode node without feedback loops. A theoretical model describing the detector response, noise, and pulse-to-pulse correlations is developed, providing quantitative predictions for the signal variance, signal-to-noise ratio (SNR), and inter-pulse correlations. Implemented with two matched InGaAs photodiodes illuminated by a 1030 nm mode-locked laser at 100 MHz, the detector exhibits excellent linearity and shot-noise-limited scaling of the signal variance with optical power. Optimizing the temporal integration window yields a maximum SNR of about 14 dB, while correlation measurements confirm negligible inter-pulse correlations. These results demonstrate that the proposed architecture offers a robust and simple solution for high-speed pulsed homodyne detection, suitable for quantum optics and continuous-variable quantum information applications.

physics.opticsCross-listedarXiv:2604.06994•Apr 9, 2026•0 citations

Die-Level Balanced Homodyne Receiver for Squeezed Light Detection in the GHz Regime

Emmily Zaiser, Alessandro Trenti, Dinka Milovančev +3 more

Quantum receiver scalability and cost-effectiveness are crucial in the evolving quantum landscape. Application based on squeezed light (e.g. high-precision measurements and quantum communication), can profit especially from integrated and low-noise detectors. The presented die-level receiver is shown in figure 1 a) and combines a novel custom transimpedance amplifier (TIA) with commercial photodiodes (PDs) [1]. This offers a more scalable solution than bulk balanced homodyne detectors (BHDs) while being low-cost compared to fully customized receivers. This design targets a high bandwidth operation while maintaining low-noise properties for the detection of weak quantum signals. To characterize this receiver, we evaluate its performance through measurements of clearance, and common-mode rejection ratio (CMRR). Based on these parameters, a simulation for its performance in the squeezed light detection measurement is presented.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 23, 2025•0 citations

A Bi-CMOS electronic photonic integrated circuit quantum light detector

Joel F. Tasker, Jonathan Frazer, Giacomo Ferranti +1 more

Complimentary metal-oxide semiconductor (CMOS) integration of quantum technology provides a route to manufacture at volume, simplify assembly, reduce footprint, and increase performance. Quantum noise-limited homodyne detectors have applications across quantum technologies, and they comprise photonics and electronics. Here, we report a quantum noise-limited monolithic electronic-photonic integrated homodyne detector, with a footprint of 80 micrometers by 220 micrometers, fabricated in a 250-nanometer lithography bipolar CMOS process. We measure a 15.3-gigahertz 3-decibel bandwidth with a maximum shot noise clearance of 12 decibels and shot noise clearance out to 26.5 gigahertz, when measured with a 9-decibel-milliwatt power local oscillator. This performance is enabled by monolithic electronic-photonic integration, which goes below the capacitance limits of devices made up of separate integrated chips or discrete components. It exceeds the bandwidth of quantum detectors with macroscopic electronic interconnects, including wire and flip chip bonding. This demonstrates electronic-photonic integration enhancing quantum photonic device performance.

arXiv:2305.08990•Science Advances•May 17, 2024•24 citations
A low-noise, high-speed balanced homodyne detector is demonstrated, combining a capacitive-feedback transimpedance amplifier implemented in 28 nm CMOS with a custom photonic integrated circuit fabricated in imec's iSiPP200 silicon photonics platform. The receiver achieves a 3-dB bandwidth of 7.6 GHz, a maximum shot noise clearance of 27 dB, a shot noise-limited bandwidth of 13.7 GHz and a common-mode rejection ratio up to 54.8 dB. These results demonstrate the suitability of CMOS capacitive-feedback transimpedance amplifiers for demanding quantum and coherent sensing optical applications, including continuous-variable quantum key distribution, quantum random number generation, and optical coherence tomography.
Optical homodyne detection is used in numerous quantum and classical applications that demand high levels of sensitivity. However, performance is typically limited due to the use of bulk optics and discrete receiver electronics. To address these performance issues, in this work we present a co-integrated balanced homodyne detector consisting of a silicon photonics optical front end and a custom integrated transimpedance amplifier designed in a 100 nm GaAs pHEMT technology. The high level of co-design and integration provides enhanced levels of stability, bandwidth, and noise performance. The presented detector shows a linear operation up to 28 dB quantum shot noise clearance and a high degree of common-mode rejection, at the same time achieving a shot-noise-limited bandwidth of more than 20 GHz. The high performance of the developed devices provide enhanced operation to many sensitive quantum applications such as continuous variable quantum key distribution, quantum random number generation, or high-speed quantum tomography.
The rapid development of continuous-variable quantum communication has driven an increasing demand for high-performance quantum signal processing modules. Among these, the balanced homodyne detector (BHD) has emerged as a leading solution for practical quantum state measurement due to its capability to provide complete quantum mechanical characterization. However, its performance is often constrained by limited bandwidth and high noise levels, primarily due to the reliance on bulk optical components and discrete receiver electronics. The dominant noise source in these systems typically stems from electronic noise, while imbalances in the optical path further degrade the signal-to-noise ratio (SNR) of the BHD. In this work, we present an adjustable integrated optical path to enhance the balance within the BHD system, along with a low-noise transimpedance amplifier (TIA) by employing optoelectronic co-design. Our design achieves a bandwidth of 2.5 GHz, an input-referred noise current of only 2 pA/√Hz in 180 nm CMOS technology, and a measured quantum shot noise clearance of 15 dB generated from a 700 μA photocurrent. This is the maximum quantum shot noise clearance at the same BHD photocurrent reported to date above the GHz bandwidth.
We present a design of balanced homodyne receivers suitable for ultra-low noise quantum applications such as continuous-variable quantum key distribution and quantum random number generation. For best noise and bandwidth performance a die-level low-parasitic photodiode together with a low-noise high-speed transimpedance amplifier are explored together with a planar lightwave circuit splitter chip serving as a photomixer. Bandwidths of 750 MHz and 2.6 GHz were accomplished while maintaining optimum noise performance, as evidenced by very high quantum-to-classical noise ratios of 26.8 and 18.6 dB, respectively. A common-mode rejection ratio of at least 40 dB was achieved for a frequency range of up to 1 GHz. Its application for continuous-variable quantum key distribution was evaluated by means of estimations under a strict untrusted receiver assumption, showing its potential for generating up to 43 Mbit/s secure-key rate over a reach of 10 km, whereas up to 100 Mbit/s could be supported at shorter reaches. Moreover, the high quantum-to-classical clearance values can enable high quality quantum random number generation at Gb/s rates. The multi-purpose operation of the designed balanced receivers for classical communications was examined showing reception sensitivities of −55.8 and −52.6 dBm at 500 Mbit/s and 1 Gbit/s quadrature phase shift keying transmission, respectively, using the 750 MHz receiver. The faster 2.6 GHz receiver enabled 10 Gbit/s duobinary transmission at −14.8 dBm sensitivity.
We design and experimentally characterize a balanced homodyne detector optimized for high-repetition-rate (100 MHz) pulsed optical sources. Unlike conventional transimpedance-amplifier architectures, which suffer from nonlinearities and dynamic instabilities with ultrashort pulses, our approach allows to directly amplify the photocurrent extracted at the common photodiode node without feedback loops. A theoretical model describing the detector response, noise, and pulse-to-pulse correlations is developed, providing quantitative predictions for the signal variance, signal-to-noise ratio (SNR), and inter-pulse correlations. Implemented with two matched InGaAs photodiodes illuminated by a 1030 nm mode-locked laser at 100 MHz, the detector exhibits excellent linearity and shot-noise-limited scaling of the signal variance with optical power. Optimizing the temporal integration window yields a maximum SNR of about 14 dB, while correlation measurements confirm negligible inter-pulse correlations. These results demonstrate that the proposed architecture offers a robust and simple solution for high-speed pulsed homodyne detection, suitable for quantum optics and continuous-variable quantum information applications.
Quantum receiver scalability and cost-effectiveness are crucial in the evolving quantum landscape. Application based on squeezed light (e.g. high-precision measurements and quantum communication), can profit especially from integrated and low-noise detectors. The presented die-level receiver is shown in figure 1 a) and combines a novel custom transimpedance amplifier (TIA) with commercial photodiodes (PDs) [1]. This offers a more scalable solution than bulk balanced homodyne detectors (BHDs) while being low-cost compared to fully customized receivers. This design targets a high bandwidth operation while maintaining low-noise properties for the detection of weak quantum signals. To characterize this receiver, we evaluate its performance through measurements of clearance, and common-mode rejection ratio (CMRR). Based on these parameters, a simulation for its performance in the squeezed light detection measurement is presented.
Complimentary metal-oxide semiconductor (CMOS) integration of quantum technology provides a route to manufacture at volume, simplify assembly, reduce footprint, and increase performance. Quantum noise-limited homodyne detectors have applications across quantum technologies, and they comprise photonics and electronics. Here, we report a quantum noise-limited monolithic electronic-photonic integrated homodyne detector, with a footprint of 80 micrometers by 220 micrometers, fabricated in a 250-nanometer lithography bipolar CMOS process. We measure a 15.3-gigahertz 3-decibel bandwidth with a maximum shot noise clearance of 12 decibels and shot noise clearance out to 26.5 gigahertz, when measured with a 9-decibel-milliwatt power local oscillator. This performance is enabled by monolithic electronic-photonic integration, which goes below the capacitance limits of devices made up of separate integrated chips or discrete components. It exceeds the bandwidth of quantum detectors with macroscopic electronic interconnects, including wire and flip chip bonding. This demonstrates electronic-photonic integration enhancing quantum photonic device performance.