Micromachines

A Low-Noise Hybrid-Integrated Balanced Homodyne Receiver with 2.5 GHz Bandwidth and 15 dB Quantum Shot Noise Clearance

Yihao Yang, Chao Zeng Cheng, Ruixuan Yang, Yangming Ren, Shenlei Bao, Jintao Xue, Houyou Lai, Binhao Wang

Published Dec 17, 2025• 0 citations
Publisher

Abstract

The rapid development of continuous-variable quantum communication has driven an increasing demand for high-performance quantum signal processing modules. Among these, the balanced homodyne detector (BHD) has emerged as a leading solution for practical quantum state measurement due to its capability to provide complete quantum mechanical characterization. However, its performance is often constrained by limited bandwidth and high noise levels, primarily due to the reliance on bulk optical components and discrete receiver electronics. The dominant noise source in these systems typically stems from electronic noise, while imbalances in the optical path further degrade the signal-to-noise ratio (SNR) of the BHD. In this work, we present an adjustable integrated optical path to enhance the balance within the BHD system, along with a low-noise transimpedance amplifier (TIA) by employing optoelectronic co-design. Our design achieves a bandwidth of 2.5 GHz, an input-referred noise current of only 2 pA/√Hz in 180 nm CMOS technology, and a measured quantum shot noise clearance of 15 dB generated from a 700 μA photocurrent. This is the maximum quantum shot noise clearance at the same BHD photocurrent reported to date above the GHz bandwidth.

DOI
10.3390/mi16121416

Related papers

Integrated balanced homodyne photonic–electronic detector for beyond 20 GHz shot-noise-limited measurements

Cédric Bruynsteen, Michael Vanhoecke, Johan Bauwelinck +1 more

Optical homodyne detection is used in numerous quantum and classical applications that demand high levels of sensitivity. However, performance is typically limited due to the use of bulk optics and discrete receiver electronics. To address these performance issues, in this work we present a co-integrated balanced homodyne detector consisting of a silicon photonics optical front end and a custom integrated transimpedance amplifier designed in a 100 nm GaAs pHEMT technology. The high level of co-design and integration provides enhanced levels of stability, bandwidth, and noise performance. The presented detector shows a linear operation up to 28 dB quantum shot noise clearance and a high degree of common-mode rejection, at the same time achieving a shot-noise-limited bandwidth of more than 20 GHz. The high performance of the developed devices provide enhanced operation to many sensitive quantum applications such as continuous variable quantum key distribution, quantum random number generation, or high-speed quantum tomography.

Optica•Jul 23, 2021•90 citations

A chip-integrated homodyne detection system with enhanced bandwidth performance for quantum applications

Si Qi Ng, Gong Zhang, Charles Ci Wen Lim +1 more

Abstract The rapid development of quantum technology has driven the need for high-performance quantum signal processing modules. Balanced homodyne detector (BHD) is one of the most promising options for practical quantum state measurement, providing substantial advantages of cost-effectiveness, no cooling requirement, and system compactness. However, due to the stringent requirements in BHD design, it typically suffers from a relatively small operating bandwidth which limits the overall speed of a quantum system. In this study, we propose comprehensive modelling for the BHD in quantum applications and enhance the performance of BHDs based on our modelling. Specifically, we utilise a photonic chip approach and optimise the electronic design to create the integrated BHD, which significantly boosts the 3 dB bandwidth to 4.75 GHz and achieves a shot-noise-limited bandwidth of 23 GHz. We demonstrate the capability of this setup to generate quantum random numbers at a rate of 240 Gbit s−1, highlighting its potential for ultra-high-speed quantum communication and quantum cryptography applications.

Quantum Science and Technology•Jun 28, 2024•9 citations

Integrated balanced homodyne detector using CMOS capacitive-feedback TIA for quantum measurements

Sarah Bastiaens, Cedric Bruynsteen, Simone Cammarata +5 more

A low-noise, high-speed balanced homodyne detector is demonstrated, combining a capacitive-feedback transimpedance amplifier implemented in 28 nm CMOS with a custom photonic integrated circuit fabricated in imec's iSiPP200 silicon photonics platform. The receiver achieves a 3-dB bandwidth of 7.6 GHz, a maximum shot noise clearance of 27 dB, a shot noise-limited bandwidth of 13.7 GHz and a common-mode rejection ratio up to 54.8 dB. These results demonstrate the suitability of CMOS capacitive-feedback transimpedance amplifiers for demanding quantum and coherent sensing optical applications, including continuous-variable quantum key distribution, quantum random number generation, and optical coherence tomography.

quant-pharXiv:2609.37671•Sep 30, 2026•0 citations

Die-Level Balanced Homodyne Receiver for Squeezed Light Detection in the GHz Regime

Emmily Zaiser, Alessandro Trenti, Dinka Milovančev +3 more

Quantum receiver scalability and cost-effectiveness are crucial in the evolving quantum landscape. Application based on squeezed light (e.g. high-precision measurements and quantum communication), can profit especially from integrated and low-noise detectors. The presented die-level receiver is shown in figure 1 a) and combines a novel custom transimpedance amplifier (TIA) with commercial photodiodes (PDs) [1]. This offers a more scalable solution than bulk balanced homodyne detectors (BHDs) while being low-cost compared to fully customized receivers. This design targets a high bandwidth operation while maintaining low-noise properties for the detection of weak quantum signals. To characterize this receiver, we evaluate its performance through measurements of clearance, and common-mode rejection ratio (CMRR). Based on these parameters, a simulation for its performance in the squeezed light detection measurement is presented.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 23, 2025•0 citations

1.55 GHz balanced homodyne detector with high gain flatness based on low noise amplifier

Shaofeng Wang, Xuyin Niu, Guangqian Wu +1 more

In this paper, a model for simulating the shot noise power and the electronic noise power of a balanced homodyne detector (BHD) using cascaded low noise amplifiers (LNAs) is presented. Moreover, the factors influencing the enhancement of BHD gain flatness are analyzed. Based on these theories, a BHD with a large clearance between shot noise and electronic noise, along with a flat broadband frequency response, is designed using LNAs and an optimized printed circuit board design. According to the experimental measurements, the bandwidth for 1 dB flatness reaches 1.4 GHz with the -3 dB bandwidth extending up to 1.55 GHz. With a 4 mW optical signal input, a signal-to-noise ratio of 12 dB is obtained at 1 GHz. The BHD exhibits excellent linearity for shot noise output up to an 8 mW optical signal input and a tested common mode rejection ratio of 63 dB. This developed BHD is well-suited for applications in high-speed continuous variable quantum key distribution and quantum random number generation.

Review of Scientific Instruments•Feb 1, 2025•7 citations

Fully discrete 2.5-GHz balanced homodyne detector with 66-dB common-mode rejection ratio

Shaofeng Wang, Shijun Zhang, Zhihao Zhang +1 more

We present a high-performance, fully discrete balanced homodyne detector (BHD) with a 2.5 GHz bandwidth, exceptional gain flatness, and superior common-mode rejection ratio. The design leverages a Rogers 4350B-based printed circuit board, a broadband multi-section RF choke bias network, and inter-stage π-section attenuators, complemented by precise photodiode matching and phase-magnitude compensation to ensure signal integrity and suppress common-mode noise. Experimental results show a -3 dB bandwidth of 2.5 GHz and 1 dB gain flatness up to 2.4 GHz-significantly exceeding our prior 1.55 GHz/1.4 GHz implementation and representing state-of-the-art performance among discrete BHDs. At 16 mW optical input, the detector delivers a 16.5 dB signal-to-noise ratio at 2 GHz while maintaining excellent linearity, and achieves a 66 dB common-mode rejection ratio at the same frequency. This cost-effective and flexible BHD is ideally suited for high-speed continuous-variable quantum key distribution and quantum random number generation.

Review of Scientific Instruments•Apr 1, 2026•1 citation
The rapid development of continuous-variable quantum communication has driven an increasing demand for high-performance quantum signal processing modules. Among these, the balanced homodyne detector (BHD) has emerged as a leading solution for practical quantum state measurement due to its capability to provide complete quantum mechanical characterization. However, its performance is often constrained by limited bandwidth and high noise levels, primarily due to the reliance on bulk optical components and discrete receiver electronics. The dominant noise source in these systems typically stems from electronic noise, while imbalances in the optical path further degrade the signal-to-noise ratio (SNR) of the BHD. In this work, we present an adjustable integrated optical path to enhance the balance within the BHD system, along with a low-noise transimpedance amplifier (TIA) by employing optoelectronic co-design. Our design achieves a bandwidth of 2.5 GHz, an input-referred noise current of only 2 pA/√Hz in 180 nm CMOS technology, and a measured quantum shot noise clearance of 15 dB generated from a 700 μA photocurrent. This is the maximum quantum shot noise clearance at the same BHD photocurrent reported to date above the GHz bandwidth.
Optical homodyne detection is used in numerous quantum and classical applications that demand high levels of sensitivity. However, performance is typically limited due to the use of bulk optics and discrete receiver electronics. To address these performance issues, in this work we present a co-integrated balanced homodyne detector consisting of a silicon photonics optical front end and a custom integrated transimpedance amplifier designed in a 100 nm GaAs pHEMT technology. The high level of co-design and integration provides enhanced levels of stability, bandwidth, and noise performance. The presented detector shows a linear operation up to 28 dB quantum shot noise clearance and a high degree of common-mode rejection, at the same time achieving a shot-noise-limited bandwidth of more than 20 GHz. The high performance of the developed devices provide enhanced operation to many sensitive quantum applications such as continuous variable quantum key distribution, quantum random number generation, or high-speed quantum tomography.
Abstract The rapid development of quantum technology has driven the need for high-performance quantum signal processing modules. Balanced homodyne detector (BHD) is one of the most promising options for practical quantum state measurement, providing substantial advantages of cost-effectiveness, no cooling requirement, and system compactness. However, due to the stringent requirements in BHD design, it typically suffers from a relatively small operating bandwidth which limits the overall speed of a quantum system. In this study, we propose comprehensive modelling for the BHD in quantum applications and enhance the performance of BHDs based on our modelling. Specifically, we utilise a photonic chip approach and optimise the electronic design to create the integrated BHD, which significantly boosts the 3 dB bandwidth to 4.75 GHz and achieves a shot-noise-limited bandwidth of 23 GHz. We demonstrate the capability of this setup to generate quantum random numbers at a rate of 240 Gbit s−1, highlighting its potential for ultra-high-speed quantum communication and quantum cryptography applications.
A low-noise, high-speed balanced homodyne detector is demonstrated, combining a capacitive-feedback transimpedance amplifier implemented in 28 nm CMOS with a custom photonic integrated circuit fabricated in imec's iSiPP200 silicon photonics platform. The receiver achieves a 3-dB bandwidth of 7.6 GHz, a maximum shot noise clearance of 27 dB, a shot noise-limited bandwidth of 13.7 GHz and a common-mode rejection ratio up to 54.8 dB. These results demonstrate the suitability of CMOS capacitive-feedback transimpedance amplifiers for demanding quantum and coherent sensing optical applications, including continuous-variable quantum key distribution, quantum random number generation, and optical coherence tomography.
Quantum receiver scalability and cost-effectiveness are crucial in the evolving quantum landscape. Application based on squeezed light (e.g. high-precision measurements and quantum communication), can profit especially from integrated and low-noise detectors. The presented die-level receiver is shown in figure 1 a) and combines a novel custom transimpedance amplifier (TIA) with commercial photodiodes (PDs) [1]. This offers a more scalable solution than bulk balanced homodyne detectors (BHDs) while being low-cost compared to fully customized receivers. This design targets a high bandwidth operation while maintaining low-noise properties for the detection of weak quantum signals. To characterize this receiver, we evaluate its performance through measurements of clearance, and common-mode rejection ratio (CMRR). Based on these parameters, a simulation for its performance in the squeezed light detection measurement is presented.
In this paper, a model for simulating the shot noise power and the electronic noise power of a balanced homodyne detector (BHD) using cascaded low noise amplifiers (LNAs) is presented. Moreover, the factors influencing the enhancement of BHD gain flatness are analyzed. Based on these theories, a BHD with a large clearance between shot noise and electronic noise, along with a flat broadband frequency response, is designed using LNAs and an optimized printed circuit board design. According to the experimental measurements, the bandwidth for 1 dB flatness reaches 1.4 GHz with the -3 dB bandwidth extending up to 1.55 GHz. With a 4 mW optical signal input, a signal-to-noise ratio of 12 dB is obtained at 1 GHz. The BHD exhibits excellent linearity for shot noise output up to an 8 mW optical signal input and a tested common mode rejection ratio of 63 dB. This developed BHD is well-suited for applications in high-speed continuous variable quantum key distribution and quantum random number generation.
We present a high-performance, fully discrete balanced homodyne detector (BHD) with a 2.5 GHz bandwidth, exceptional gain flatness, and superior common-mode rejection ratio. The design leverages a Rogers 4350B-based printed circuit board, a broadband multi-section RF choke bias network, and inter-stage π-section attenuators, complemented by precise photodiode matching and phase-magnitude compensation to ensure signal integrity and suppress common-mode noise. Experimental results show a -3 dB bandwidth of 2.5 GHz and 1 dB gain flatness up to 2.4 GHz-significantly exceeding our prior 1.55 GHz/1.4 GHz implementation and representing state-of-the-art performance among discrete BHDs. At 16 mW optical input, the detector delivers a 16.5 dB signal-to-noise ratio at 2 GHz while maintaining excellent linearity, and achieves a 66 dB common-mode rejection ratio at the same frequency. This cost-effective and flexible BHD is ideally suited for high-speed continuous-variable quantum key distribution and quantum random number generation.