Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Tạp chí Khoa học và Công nghệ- Đại học Công nghệ Đồng Nai

STUDY OF A BALANCED HOMODYNE DETECTOR WITH HIGH COMMON-MODE NOISE SUPPRESSION FOR QUANTUM OPTICS EXPERIMENTS

ThS. Nguyễn Thị Hiền, ThS. Hùynh Đức Chấn

Published Jul 21, 2026• 0 citations
OpenAlex

Abstract

This paper presents the design, construction, and performance evaluation of a balanced homodyne detector (BHD) intended for continuous-variable quantum optics applications. The system employs two closely matched IG17X500 photodiodes and a low-noise differential amplifier to suppress classical technical noise and enhance the sensitivity of quadrature measurements. Experimental tests using a 1064 nm Nd:YAG laser demonstrate strong photodiode linearity and a quantum efficiency of approximately 68%. Spectral analysis further reveals a Common-Mode Rejection Ratio (CMRR) of around 52 dB, indicating highly effective cancellation of laser-induced and electronic noise. A characteristic relaxation-oscillation peak at 284.375 kHz is observed in the unbalanced detector output but significantly reduced in the balanced output, confirming the robustness of the homodyne architecture. These results verify that the implemented BHD operates near the shot-noise limit and is well suited for applications such as squeezed-state detection, vacuum noise characterization, and precision continuous-variable quantum measurements.

Related papers

Balanced homodyne detection circuit design analysis for high gain and low noise performance

Akanksha Angural, Joyee Ghosh

The study, generation, and application of squeezed states of light has been a widely researched area in quantum optics. Vacuum fluctuations or photon shot noise quantified in terms of quadrature operators, impose a quantum limit on the sensitivity of quantum sensing and quantum communication systems. Thus, squeezing the quadratures reduces the quantum uncertainty in a particular quadrature. The amount of squeezing is, however, highly limited by the optics in the experiments and the performance of the balanced homodyne detection (BHD) systems employed for the detection of the squeezed states of light. In this paper, we have analytically studied the steady state, transient and noise responses of the balanced homodyne detection (BHD) circuitry by comparing two configurations i.e., a variable gain circuit with a differential amplifier and a current subtracting circuit with differential fine-tuning circuit (DFTC) and an adjustable bias (ABV). The current subtracting circuit design with DFTC and ABV has been adopted from Xiaoli et al. [1] in order to compensate for any differences in the photodiode performance characteristics in the two arms. A variable gain configuration is used to compensate for the unequal beam splitter ratio and uneven optical powers in the two arms. In order to further improve the noise performance of the system, a differential amplifier is used in the output of the variable gain configuration. A high transimpedance gain (~>70 dB) and a low noise (~<500nV/ √ Hz) performance can be achieved using these circuits as per our analysis.

IEEE International Conference on Emerging Electronics (ICEE)•Dec 11, 2022•0 citations

Fully discrete 2.5-GHz balanced homodyne detector with 66-dB common-mode rejection ratio

Shaofeng Wang, Shijun Zhang, Zhihao Zhang +1 more

We present a high-performance, fully discrete balanced homodyne detector (BHD) with a 2.5 GHz bandwidth, exceptional gain flatness, and superior common-mode rejection ratio. The design leverages a Rogers 4350B-based printed circuit board, a broadband multi-section RF choke bias network, and inter-stage π-section attenuators, complemented by precise photodiode matching and phase-magnitude compensation to ensure signal integrity and suppress common-mode noise. Experimental results show a -3 dB bandwidth of 2.5 GHz and 1 dB gain flatness up to 2.4 GHz-significantly exceeding our prior 1.55 GHz/1.4 GHz implementation and representing state-of-the-art performance among discrete BHDs. At 16 mW optical input, the detector delivers a 16.5 dB signal-to-noise ratio at 2 GHz while maintaining excellent linearity, and achieves a 66 dB common-mode rejection ratio at the same frequency. This cost-effective and flexible BHD is ideally suited for high-speed continuous-variable quantum key distribution and quantum random number generation.

Review of Scientific Instruments•Apr 1, 2026•2 citations

A Simple and Robust Balanced Homodyne Detector for High-Repetition-Rate Pulsed Sources

Samuele Altilia, Edoardo Suerra, Pietro Puppi +3 more

We design and experimentally characterize a balanced homodyne detector optimized for high-repetition-rate (100 MHz) pulsed optical sources. Unlike conventional transimpedance-amplifier architectures, which suffer from nonlinearities and dynamic instabilities with ultrashort pulses, our approach allows to directly amplify the photocurrent extracted at the common photodiode node without feedback loops. A theoretical model describing the detector response, noise, and pulse-to-pulse correlations is developed, providing quantitative predictions for the signal variance, signal-to-noise ratio (SNR), and inter-pulse correlations. Implemented with two matched InGaAs photodiodes illuminated by a 1030 nm mode-locked laser at 100 MHz, the detector exhibits excellent linearity and shot-noise-limited scaling of the signal variance with optical power. Optimizing the temporal integration window yields a maximum SNR of about 14 dB, while correlation measurements confirm negligible inter-pulse correlations. These results demonstrate that the proposed architecture offers a robust and simple solution for high-speed pulsed homodyne detection, suitable for quantum optics and continuous-variable quantum information applications.

physics.opticsCross-listedarXiv:2604.06994•Measurement Science and Technology•Apr 9, 2026•1 citation

A Low-Noise Hybrid-Integrated Balanced Homodyne Receiver with 2.5 GHz Bandwidth and 15 dB Quantum Shot Noise Clearance

Yihao Yang, Chao Zeng Cheng, Ruixuan Yang +5 more

The rapid development of continuous-variable quantum communication has driven an increasing demand for high-performance quantum signal processing modules. Among these, the balanced homodyne detector (BHD) has emerged as a leading solution for practical quantum state measurement due to its capability to provide complete quantum mechanical characterization. However, its performance is often constrained by limited bandwidth and high noise levels, primarily due to the reliance on bulk optical components and discrete receiver electronics. The dominant noise source in these systems typically stems from electronic noise, while imbalances in the optical path further degrade the signal-to-noise ratio (SNR) of the BHD. In this work, we present an adjustable integrated optical path to enhance the balance within the BHD system, along with a low-noise transimpedance amplifier (TIA) by employing optoelectronic co-design. Our design achieves a bandwidth of 2.5 GHz, an input-referred noise current of only 2 pA/√Hz in 180 nm CMOS technology, and a measured quantum shot noise clearance of 15 dB generated from a 700 μA photocurrent. This is the maximum quantum shot noise clearance at the same BHD photocurrent reported to date above the GHz bandwidth.

Micromachines•Dec 17, 2025•1 citation

A 600 MHz Balanced Homodyne Detector for Quantum Information Processing

Tianxiang Zhang, Yundi Huang, Xiangyu Wang +2 more

Balanced homodyne detector (BHD) has been widely used in quantum information processing. In this paper, we design a wide bandwidth BHD and implement an optical layout to test the performance of our BHD. The test results show that the bandwidth is about 600 MHz, the quantum to classical noise ratio (QCNR) is 15.2 dB and the common mode rejection ratio (CMRR) is 41.16 dB. The performance of BHD shows that it can meet the requirements of high-speed applications in quantum information processing.

Advances in Engineering Technology Research•May 13, 2022•1 citation

基于R‑C耦合跨阻设计的1 kHz~200 MHz宽带平衡零拍探测器

王少锋 Wang Shaofeng, 刘宣泽 Liu Xuanze, 李汉卿 Li Hanqing +2 more

Objective The balanced homodyne detector (BHD) is widely used in quantum noise measurement, gravitational wave detection, high-sensitivity interferometric timing measurement, continuous-variable quantum key distribution, and quantum random number generation. Highly sensitive to the amplitude and phase of the incident light, the BHD can reliably extract quantum fluctuations, suppress the classical common-mode noise, and amplify quantum fluctuations to the macro level. However, the performance of the BHD is limited by the bandwidth, signal-to-noise ratio (SNR), and common-mode rejection ratio (CMRR) of the detector. The optimal design of the BHD has always been a research hotspot. The transimpedance circuit based on a direct current (DC) coupled circuit is not suitable for detecting quantum noise. The reason is that as the power of the incident light increases, the unbalanced DC increases rapidly, and the transimpedance amplifier is saturated, which significantly reduces the dynamic range of the BHD. The BHD based on an inductor-capacitor (L-C) coupled circuit generates higher electronic noise at an analyzing frequency in the kHz range. It is not suitable for low-frequency measurements due to the parasitic effect of the inductor and the low impedance of the inductor at an analyzing frequency in the kHz range. In this paper, the noise sources of the BHD are analyzed theoretically, and a resistor-capacitor (R-C) coupled transimpedance circuit is used to improve the performance of the BHD at an analyzing frequency in the kHz range. Furthermore, the transimpedance circuit is optimized to increase the bandwidth to 200 MHz. The CMRR of the BHD is improved by designing a self-subtraction photodetector scheme, a variable optical attenuator, and an adjustable reverse bias voltage. These designs allow the BHD to meet the low-frequency and high-frequency measurements with high SNR and CMRR in quantum noise measurement. Methods To enable the BHD to measure both low-frequency and high-frequency signals with high sensitivity, this paper adopts the BHD based on an R-C coupled transimpedance circuit. Two photodiodes are connected in series, and the balanced current signal in the two photodiodes is divided into a DC signal and an alternating current (AC) signal by the R-C coupled structure. The AC signal is converted into a voltage signal by a transimpedance amplifier (TIA) and is further used to measure the shot-noise power of the incident light. The DC signal is converted into a voltage signal by a load resistor and is then used to measure the balance between the two incident lights. To reduce the crosstalk between the DC circuit and the AC circuit, an isolation amplifier is added after the load resistor. An adjustable bias voltage (BV) circuit is used to adjust the junction capacitance of the photodiodes and further improve the CMRR. To compensate for the difference in the amplitude of the two photodiodes and thereby improve the CMRR of the BHD, the paper also utilizes a variable optical attenuator based on fiber bending, where variable attenuation is achieved by changing the radius of the bent fiber. The attenuation of the fiber is precisely adjusted to balance the photocurrent. In addition, an equivalent noise model is constructed. The electronic noise from the TIA circuit includes four parts, i.e., the noise introduced by the dark current in the photodiodes, the thermal noise in the feedback resistor, the noise generated by the input current noise in the TIA, and the noise produced by the input voltage noise. On the basis of theoretical analysis, reasonable DC load resistance and feedback capacitance, photodiodes with low dark current and low junction capacitance, and a TIA with low input noise are selected to reduce the electronic noise and improve the SNR of the BHD. Results and Discussions A BHD with an R-C coupled circuit structure is designed (Fig. 1). A test device is built to test the performance of the BHD. The AC output is connected with a spectrometer to measure the bandwidth and the SNR of the BHD. The DC output is connected with an oscilloscope to make sure that the power of the two incident lights is balanced (Fig. 3). When the incident optical power is 8, 4, 2, and 1 mW, respectively, the paper tests the shot-noise spectrum and the electronic noise spectrum of the BHD with different analyzing frequencies. The test results show that the 3-dB bandwidth of the BHD is 1 kHz-200 MHz. The resolution bandwidth (RBW) and the video bandwidth (VBW) of the spectrum analyzer are set to 10 Hz and 1 Hz, respectively, and the number of averaging times is set to 40. In this case, the SNR is 12 dB at the analyzing frequency of 5 kHz under an incident optical power of 8 mW. The SNR is 20 dB at the analyzing frequency of 100 MHz when the RBW is 200 kHz and the VBW is 100 Hz. Moreover, in the analyzing frequency range of 10 kHz-200 MHz, the shot-noise power decreases by about 3 dB when the incident optical power decreases by half, indicating that the AC output of the BHD has favorable linear gain characteristics in the range of 1 mW to 8 mW (Fig. 4). In addition, 5 kHz and 100 MHz sinusoidal signals are loaded into an electro-optical amplitude modulator to modulate the incident light and thereby test the CMRR. The results show that the CMRR is 70 dB at the analyzing frequency of 5 kHz and 66 dB at the analyzing frequency of 100 MHz (Fig. 5). Conclusions By analyzing the noise sources of the BHD, adopting the R-C coupled transimpedance circuit, and optimizing the TIA circuit, this paper implements a broadband balanced homodyne detector that works in the bandwidth range from 1 kHz to 200 MHz with low noise and high CMRR. In the case of an incident optical power of 8 mW@1550 nm, the shot-noise power is 12 dB higher than the electronic noise power and the CMRR reaches 70 dB at the analyzing frequency of 5 kHz, and the shot-noise power is 20 dB higher than the electronic noise power and the CMRR reaches 66 dB at the analyzing frequency of 100 MHz. Such a homodyne detector can serve as a high-performance detection tool in various applications, such as low-frequency gravitational wave detection, high-speed continuous-variable quantum key distribution, and high-speed quantum random number generation.

Acta Optica Sinica•Jan 1, 2023•7 citations
This paper presents the design, construction, and performance evaluation of a balanced homodyne detector (BHD) intended for continuous-variable quantum optics applications. The system employs two closely matched IG17X500 photodiodes and a low-noise differential amplifier to suppress classical technical noise and enhance the sensitivity of quadrature measurements. Experimental tests using a 1064 nm Nd:YAG laser demonstrate strong photodiode linearity and a quantum efficiency of approximately 68%. Spectral analysis further reveals a Common-Mode Rejection Ratio (CMRR) of around 52 dB, indicating highly effective cancellation of laser-induced and electronic noise. A characteristic relaxation-oscillation peak at 284.375 kHz is observed in the unbalanced detector output but significantly reduced in the balanced output, confirming the robustness of the homodyne architecture. These results verify that the implemented BHD operates near the shot-noise limit and is well suited for applications such as squeezed-state detection, vacuum noise characterization, and precision continuous-variable quantum measurements.
The study, generation, and application of squeezed states of light has been a widely researched area in quantum optics. Vacuum fluctuations or photon shot noise quantified in terms of quadrature operators, impose a quantum limit on the sensitivity of quantum sensing and quantum communication systems. Thus, squeezing the quadratures reduces the quantum uncertainty in a particular quadrature. The amount of squeezing is, however, highly limited by the optics in the experiments and the performance of the balanced homodyne detection (BHD) systems employed for the detection of the squeezed states of light. In this paper, we have analytically studied the steady state, transient and noise responses of the balanced homodyne detection (BHD) circuitry by comparing two configurations i.e., a variable gain circuit with a differential amplifier and a current subtracting circuit with differential fine-tuning circuit (DFTC) and an adjustable bias (ABV). The current subtracting circuit design with DFTC and ABV has been adopted from Xiaoli et al. [1] in order to compensate for any differences in the photodiode performance characteristics in the two arms. A variable gain configuration is used to compensate for the unequal beam splitter ratio and uneven optical powers in the two arms. In order to further improve the noise performance of the system, a differential amplifier is used in the output of the variable gain configuration. A high transimpedance gain (~>70 dB) and a low noise (~<500nV/ √ Hz) performance can be achieved using these circuits as per our analysis.
We present a high-performance, fully discrete balanced homodyne detector (BHD) with a 2.5 GHz bandwidth, exceptional gain flatness, and superior common-mode rejection ratio. The design leverages a Rogers 4350B-based printed circuit board, a broadband multi-section RF choke bias network, and inter-stage π-section attenuators, complemented by precise photodiode matching and phase-magnitude compensation to ensure signal integrity and suppress common-mode noise. Experimental results show a -3 dB bandwidth of 2.5 GHz and 1 dB gain flatness up to 2.4 GHz-significantly exceeding our prior 1.55 GHz/1.4 GHz implementation and representing state-of-the-art performance among discrete BHDs. At 16 mW optical input, the detector delivers a 16.5 dB signal-to-noise ratio at 2 GHz while maintaining excellent linearity, and achieves a 66 dB common-mode rejection ratio at the same frequency. This cost-effective and flexible BHD is ideally suited for high-speed continuous-variable quantum key distribution and quantum random number generation.
We design and experimentally characterize a balanced homodyne detector optimized for high-repetition-rate (100 MHz) pulsed optical sources. Unlike conventional transimpedance-amplifier architectures, which suffer from nonlinearities and dynamic instabilities with ultrashort pulses, our approach allows to directly amplify the photocurrent extracted at the common photodiode node without feedback loops. A theoretical model describing the detector response, noise, and pulse-to-pulse correlations is developed, providing quantitative predictions for the signal variance, signal-to-noise ratio (SNR), and inter-pulse correlations. Implemented with two matched InGaAs photodiodes illuminated by a 1030 nm mode-locked laser at 100 MHz, the detector exhibits excellent linearity and shot-noise-limited scaling of the signal variance with optical power. Optimizing the temporal integration window yields a maximum SNR of about 14 dB, while correlation measurements confirm negligible inter-pulse correlations. These results demonstrate that the proposed architecture offers a robust and simple solution for high-speed pulsed homodyne detection, suitable for quantum optics and continuous-variable quantum information applications.
The rapid development of continuous-variable quantum communication has driven an increasing demand for high-performance quantum signal processing modules. Among these, the balanced homodyne detector (BHD) has emerged as a leading solution for practical quantum state measurement due to its capability to provide complete quantum mechanical characterization. However, its performance is often constrained by limited bandwidth and high noise levels, primarily due to the reliance on bulk optical components and discrete receiver electronics. The dominant noise source in these systems typically stems from electronic noise, while imbalances in the optical path further degrade the signal-to-noise ratio (SNR) of the BHD. In this work, we present an adjustable integrated optical path to enhance the balance within the BHD system, along with a low-noise transimpedance amplifier (TIA) by employing optoelectronic co-design. Our design achieves a bandwidth of 2.5 GHz, an input-referred noise current of only 2 pA/√Hz in 180 nm CMOS technology, and a measured quantum shot noise clearance of 15 dB generated from a 700 μA photocurrent. This is the maximum quantum shot noise clearance at the same BHD photocurrent reported to date above the GHz bandwidth.
Objective The balanced homodyne detector (BHD) is widely used in quantum noise measurement, gravitational wave detection, high-sensitivity interferometric timing measurement, continuous-variable quantum key distribution, and quantum random number generation. Highly sensitive to the amplitude and phase of the incident light, the BHD can reliably extract quantum fluctuations, suppress the classical common-mode noise, and amplify quantum fluctuations to the macro level. However, the performance of the BHD is limited by the bandwidth, signal-to-noise ratio (SNR), and common-mode rejection ratio (CMRR) of the detector. The optimal design of the BHD has always been a research hotspot. The transimpedance circuit based on a direct current (DC) coupled circuit is not suitable for detecting quantum noise. The reason is that as the power of the incident light increases, the unbalanced DC increases rapidly, and the transimpedance amplifier is saturated, which significantly reduces the dynamic range of the BHD. The BHD based on an inductor-capacitor (L-C) coupled circuit generates higher electronic noise at an analyzing frequency in the kHz range. It is not suitable for low-frequency measurements due to the parasitic effect of the inductor and the low impedance of the inductor at an analyzing frequency in the kHz range. In this paper, the noise sources of the BHD are analyzed theoretically, and a resistor-capacitor (R-C) coupled transimpedance circuit is used to improve the performance of the BHD at an analyzing frequency in the kHz range. Furthermore, the transimpedance circuit is optimized to increase the bandwidth to 200 MHz. The CMRR of the BHD is improved by designing a self-subtraction photodetector scheme, a variable optical attenuator, and an adjustable reverse bias voltage. These designs allow the BHD to meet the low-frequency and high-frequency measurements with high SNR and CMRR in quantum noise measurement. Methods To enable the BHD to measure both low-frequency and high-frequency signals with high sensitivity, this paper adopts the BHD based on an R-C coupled transimpedance circuit. Two photodiodes are connected in series, and the balanced current signal in the two photodiodes is divided into a DC signal and an alternating current (AC) signal by the R-C coupled structure. The AC signal is converted into a voltage signal by a transimpedance amplifier (TIA) and is further used to measure the shot-noise power of the incident light. The DC signal is converted into a voltage signal by a load resistor and is then used to measure the balance between the two incident lights. To reduce the crosstalk between the DC circuit and the AC circuit, an isolation amplifier is added after the load resistor. An adjustable bias voltage (BV) circuit is used to adjust the junction capacitance of the photodiodes and further improve the CMRR. To compensate for the difference in the amplitude of the two photodiodes and thereby improve the CMRR of the BHD, the paper also utilizes a variable optical attenuator based on fiber bending, where variable attenuation is achieved by changing the radius of the bent fiber. The attenuation of the fiber is precisely adjusted to balance the photocurrent. In addition, an equivalent noise model is constructed. The electronic noise from the TIA circuit includes four parts, i.e., the noise introduced by the dark current in the photodiodes, the thermal noise in the feedback resistor, the noise generated by the input current noise in the TIA, and the noise produced by the input voltage noise. On the basis of theoretical analysis, reasonable DC load resistance and feedback capacitance, photodiodes with low dark current and low junction capacitance, and a TIA with low input noise are selected to reduce the electronic noise and improve the SNR of the BHD. Results and Discussions A BHD with an R-C coupled circuit structure is designed (Fig. 1). A test device is built to test the performance of the BHD. The AC output is connected with a spectrometer to measure the bandwidth and the SNR of the BHD. The DC output is connected with an oscilloscope to make sure that the power of the two incident lights is balanced (Fig. 3). When the incident optical power is 8, 4, 2, and 1 mW, respectively, the paper tests the shot-noise spectrum and the electronic noise spectrum of the BHD with different analyzing frequencies. The test results show that the 3-dB bandwidth of the BHD is 1 kHz-200 MHz. The resolution bandwidth (RBW) and the video bandwidth (VBW) of the spectrum analyzer are set to 10 Hz and 1 Hz, respectively, and the number of averaging times is set to 40. In this case, the SNR is 12 dB at the analyzing frequency of 5 kHz under an incident optical power of 8 mW. The SNR is 20 dB at the analyzing frequency of 100 MHz when the RBW is 200 kHz and the VBW is 100 Hz. Moreover, in the analyzing frequency range of 10 kHz-200 MHz, the shot-noise power decreases by about 3 dB when the incident optical power decreases by half, indicating that the AC output of the BHD has favorable linear gain characteristics in the range of 1 mW to 8 mW (Fig. 4). In addition, 5 kHz and 100 MHz sinusoidal signals are loaded into an electro-optical amplitude modulator to modulate the incident light and thereby test the CMRR. The results show that the CMRR is 70 dB at the analyzing frequency of 5 kHz and 66 dB at the analyzing frequency of 100 MHz (Fig. 5). Conclusions By analyzing the noise sources of the BHD, adopting the R-C coupled transimpedance circuit, and optimizing the TIA circuit, this paper implements a broadband balanced homodyne detector that works in the bandwidth range from 1 kHz to 200 MHz with low noise and high CMRR. In the case of an incident optical power of 8 mW@1550 nm, the shot-noise power is 12 dB higher than the electronic noise power and the CMRR reaches 70 dB at the analyzing frequency of 5 kHz, and the shot-noise power is 20 dB higher than the electronic noise power and the CMRR reaches 66 dB at the analyzing frequency of 100 MHz. Such a homodyne detector can serve as a high-performance detection tool in various applications, such as low-frequency gravitational wave detection, high-speed continuous-variable quantum key distribution, and high-speed quantum random number generation.