Balanced homodyne detection circuit design analysis for high gain and low noise performance

Akanksha Angural, Joyee Ghosh

Published Dec 11, 2022• 0 citations
Publisher

Abstract

The study, generation, and application of squeezed states of light has been a widely researched area in quantum optics. Vacuum fluctuations or photon shot noise quantified in terms of quadrature operators, impose a quantum limit on the sensitivity of quantum sensing and quantum communication systems. Thus, squeezing the quadratures reduces the quantum uncertainty in a particular quadrature. The amount of squeezing is, however, highly limited by the optics in the experiments and the performance of the balanced homodyne detection (BHD) systems employed for the detection of the squeezed states of light. In this paper, we have analytically studied the steady state, transient and noise responses of the balanced homodyne detection (BHD) circuitry by comparing two configurations i.e., a variable gain circuit with a differential amplifier and a current subtracting circuit with differential fine-tuning circuit (DFTC) and an adjustable bias (ABV). The current subtracting circuit design with DFTC and ABV has been adopted from Xiaoli et al. [1] in order to compensate for any differences in the photodiode performance characteristics in the two arms. A variable gain configuration is used to compensate for the unequal beam splitter ratio and uneven optical powers in the two arms. In order to further improve the noise performance of the system, a differential amplifier is used in the output of the variable gain configuration. A high transimpedance gain (~>70 dB) and a low noise (~<500nV/ √ Hz) performance can be achieved using these circuits as per our analysis.

DOI
10.1109/icee56203.2022.10118151

Related papers

基于R‑C耦合跨阻设计的1 kHz~200 MHz宽带平衡零拍探测器

王少锋 Wang Shaofeng, 刘宣泽 Liu Xuanze, 李汉卿 Li Hanqing +2 more

Objective The balanced homodyne detector (BHD) is widely used in quantum noise measurement, gravitational wave detection, high-sensitivity interferometric timing measurement, continuous-variable quantum key distribution, and quantum random number generation. Highly sensitive to the amplitude and phase of the incident light, the BHD can reliably extract quantum fluctuations, suppress the classical common-mode noise, and amplify quantum fluctuations to the macro level. However, the performance of the BHD is limited by the bandwidth, signal-to-noise ratio (SNR), and common-mode rejection ratio (CMRR) of the detector. The optimal design of the BHD has always been a research hotspot. The transimpedance circuit based on a direct current (DC) coupled circuit is not suitable for detecting quantum noise. The reason is that as the power of the incident light increases, the unbalanced DC increases rapidly, and the transimpedance amplifier is saturated, which significantly reduces the dynamic range of the BHD. The BHD based on an inductor-capacitor (L-C) coupled circuit generates higher electronic noise at an analyzing frequency in the kHz range. It is not suitable for low-frequency measurements due to the parasitic effect of the inductor and the low impedance of the inductor at an analyzing frequency in the kHz range. In this paper, the noise sources of the BHD are analyzed theoretically, and a resistor-capacitor (R-C) coupled transimpedance circuit is used to improve the performance of the BHD at an analyzing frequency in the kHz range. Furthermore, the transimpedance circuit is optimized to increase the bandwidth to 200 MHz. The CMRR of the BHD is improved by designing a self-subtraction photodetector scheme, a variable optical attenuator, and an adjustable reverse bias voltage. These designs allow the BHD to meet the low-frequency and high-frequency measurements with high SNR and CMRR in quantum noise measurement. Methods To enable the BHD to measure both low-frequency and high-frequency signals with high sensitivity, this paper adopts the BHD based on an R-C coupled transimpedance circuit. Two photodiodes are connected in series, and the balanced current signal in the two photodiodes is divided into a DC signal and an alternating current (AC) signal by the R-C coupled structure. The AC signal is converted into a voltage signal by a transimpedance amplifier (TIA) and is further used to measure the shot-noise power of the incident light. The DC signal is converted into a voltage signal by a load resistor and is then used to measure the balance between the two incident lights. To reduce the crosstalk between the DC circuit and the AC circuit, an isolation amplifier is added after the load resistor. An adjustable bias voltage (BV) circuit is used to adjust the junction capacitance of the photodiodes and further improve the CMRR. To compensate for the difference in the amplitude of the two photodiodes and thereby improve the CMRR of the BHD, the paper also utilizes a variable optical attenuator based on fiber bending, where variable attenuation is achieved by changing the radius of the bent fiber. The attenuation of the fiber is precisely adjusted to balance the photocurrent. In addition, an equivalent noise model is constructed. The electronic noise from the TIA circuit includes four parts, i.e., the noise introduced by the dark current in the photodiodes, the thermal noise in the feedback resistor, the noise generated by the input current noise in the TIA, and the noise produced by the input voltage noise. On the basis of theoretical analysis, reasonable DC load resistance and feedback capacitance, photodiodes with low dark current and low junction capacitance, and a TIA with low input noise are selected to reduce the electronic noise and improve the SNR of the BHD. Results and Discussions A BHD with an R-C coupled circuit structure is designed (Fig. 1). A test device is built to test the performance of the BHD. The AC output is connected with a spectrometer to measure the bandwidth and the SNR of the BHD. The DC output is connected with an oscilloscope to make sure that the power of the two incident lights is balanced (Fig. 3). When the incident optical power is 8, 4, 2, and 1 mW, respectively, the paper tests the shot-noise spectrum and the electronic noise spectrum of the BHD with different analyzing frequencies. The test results show that the 3-dB bandwidth of the BHD is 1 kHz-200 MHz. The resolution bandwidth (RBW) and the video bandwidth (VBW) of the spectrum analyzer are set to 10 Hz and 1 Hz, respectively, and the number of averaging times is set to 40. In this case, the SNR is 12 dB at the analyzing frequency of 5 kHz under an incident optical power of 8 mW. The SNR is 20 dB at the analyzing frequency of 100 MHz when the RBW is 200 kHz and the VBW is 100 Hz. Moreover, in the analyzing frequency range of 10 kHz-200 MHz, the shot-noise power decreases by about 3 dB when the incident optical power decreases by half, indicating that the AC output of the BHD has favorable linear gain characteristics in the range of 1 mW to 8 mW (Fig. 4). In addition, 5 kHz and 100 MHz sinusoidal signals are loaded into an electro-optical amplitude modulator to modulate the incident light and thereby test the CMRR. The results show that the CMRR is 70 dB at the analyzing frequency of 5 kHz and 66 dB at the analyzing frequency of 100 MHz (Fig. 5). Conclusions By analyzing the noise sources of the BHD, adopting the R-C coupled transimpedance circuit, and optimizing the TIA circuit, this paper implements a broadband balanced homodyne detector that works in the bandwidth range from 1 kHz to 200 MHz with low noise and high CMRR. In the case of an incident optical power of 8 mW@1550 nm, the shot-noise power is 12 dB higher than the electronic noise power and the CMRR reaches 70 dB at the analyzing frequency of 5 kHz, and the shot-noise power is 20 dB higher than the electronic noise power and the CMRR reaches 66 dB at the analyzing frequency of 100 MHz. Such a homodyne detector can serve as a high-performance detection tool in various applications, such as low-frequency gravitational wave detection, high-speed continuous-variable quantum key distribution, and high-speed quantum random number generation.

Acta Optica Sinica•Jan 1, 2023•7 citations

STUDY OF A BALANCED HOMODYNE DETECTOR WITH HIGH COMMON-MODE NOISE SUPPRESSION FOR QUANTUM OPTICS EXPERIMENTS

ThS. Nguyễn Thị Hiền, ThS. Hùynh Đức Chấn

This paper presents the design, construction, and performance evaluation of a balanced homodyne detector (BHD) intended for continuous-variable quantum optics applications. The system employs two closely matched IG17X500 photodiodes and a low-noise differential amplifier to suppress classical technical noise and enhance the sensitivity of quadrature measurements. Experimental tests using a 1064 nm Nd:YAG laser demonstrate strong photodiode linearity and a quantum efficiency of approximately 68%. Spectral analysis further reveals a Common-Mode Rejection Ratio (CMRR) of around 52 dB, indicating highly effective cancellation of laser-induced and electronic noise. A characteristic relaxation-oscillation peak at 284.375 kHz is observed in the unbalanced detector output but significantly reduced in the balanced output, confirming the robustness of the homodyne architecture. These results verify that the implemented BHD operates near the shot-noise limit and is well suited for applications such as squeezed-state detection, vacuum noise characterization, and precision continuous-variable quantum measurements.

Tạp chí Khoa học và Công nghệ- Đại học Công nghệ Đồng Nai•Jul 21, 2026•0 citations

A Low-Noise Hybrid-Integrated Balanced Homodyne Receiver with 2.5 GHz Bandwidth and 15 dB Quantum Shot Noise Clearance

Yihao Yang, Chao Zeng Cheng, Ruixuan Yang +5 more

The rapid development of continuous-variable quantum communication has driven an increasing demand for high-performance quantum signal processing modules. Among these, the balanced homodyne detector (BHD) has emerged as a leading solution for practical quantum state measurement due to its capability to provide complete quantum mechanical characterization. However, its performance is often constrained by limited bandwidth and high noise levels, primarily due to the reliance on bulk optical components and discrete receiver electronics. The dominant noise source in these systems typically stems from electronic noise, while imbalances in the optical path further degrade the signal-to-noise ratio (SNR) of the BHD. In this work, we present an adjustable integrated optical path to enhance the balance within the BHD system, along with a low-noise transimpedance amplifier (TIA) by employing optoelectronic co-design. Our design achieves a bandwidth of 2.5 GHz, an input-referred noise current of only 2 pA/√Hz in 180 nm CMOS technology, and a measured quantum shot noise clearance of 15 dB generated from a 700 μA photocurrent. This is the maximum quantum shot noise clearance at the same BHD photocurrent reported to date above the GHz bandwidth.

Micromachines•Dec 17, 2025•1 citation

多像素平衡零拍探测器研究

王少锋 Wang Shaofeng, 李汉卿 Li Hanqing, 李康康 Li Kangkang +3 more

Objective As an important tool for quantum optical measurement, the balanced homodyne detector (BHD) is highly sensitive to the amplitude and phase of the incident light. It can reliably extract quantum fluctuations, suppress classical common-mode noise, and amplify quantum fluctuations to the macro level. Additionally, it has been widely employed in quantum noise measurement, gravitational wave detection, high-sensitivity interferometric timing measurement, continuous variable quantum key distribution, and quantum random number generator. The common-mode rejection ratio (CMRR), operating bandwidth, and signal-to-noise ratio (SNR) of the detector have been the research focuses. The optical frequency comb contains a large number of equally spaced longitudinal modes, which is a good multi-mode resource. The spectrum width of the optical frequency comb is in the order of nanometers. The quantum optical frequency comb which breaks the limit of shot noise can be generated by nonlinear processes. Quantum optical frequency comb has a great application prospect in quantum precision measurement. Spectrally resolved balanced homodyne detection is an important detection method of quantum optical frequency comb. We analyze the noise source of the balanced homodyne detector theoretically and design the multi-pixel balanced homodyne detector (MBHD) based on photodiode array and multi-channel inductance-capacitance (L-C) coupled transimpedance amplifier (TIA) circuit. These designs enable MBHD to meet multi-channel parallel and high-SNR quantum noise measurements. Methods The MBHD consists of two highly symmetrical multi-pixel photodetectors (MPDs) and a multi-channel subtracter (Fig. 1). Each MPD includes a photodiode array, a multi-channel L-C coupled structure, AC amplification, and DC amplification. The photocurrent generated by the corresponding pair of pixels in the two MPD flows through their respective AC amplification outputs, and the common-mode signal in the detection result is eliminated by the subtracter to complete the multi-pixel parallel balanced homodyne detection. Multi-channel DC output monitors the optical power of all pixels by a multi-function data acquisition card (DAQ). In the amplification circuit structure of the single pixel in MPD, the generated photocurrent signal is divided into DC signal and AC signal through the L-C coupled circuit. The AC signal is converted into a voltage signal by a TIA and is further adopted to measure the intensity noise power of the incident light. The DC signal is converted into a voltage signal by a load resistor and a isolation amplifier. Additionally, an equivalent noise model is built to analyze the electronic noise. Due to the multi-channel parallel structure of the MBHD, each channel is similar to each other and independent. The electronic noise of the single-pixel channel includes the noise generated by the dark current of the photodiode, the thermal noise generated by the feedback resistance in the transimpedance amplifier circuit, the noise generated by the input voltage noise of the transimpedance amplifier, and the noise generated by the input current noise of the transimpedance amplifier. Theoretical analysis shows that a reasonable selection of feedback resistance and inductance, photodiode with low dark current and low junction capacitance, and the TIA with low input noise can reduce the electronic noise of the detector. Meanwhile, the L-C coupled structure is better than the R-C coupled structure in experimental conditions (Fig. 2). Results and Discussions The device is constructed to test the performance of MBHD (Fig. 3). AC output of MBHD is connected to a spectrometer to measure the bandwidth and SNR. The DC signals of each pixel are measured by a DAQ to monitor the optical powers of each pixel. When the optical power is distributed on all pixel channels, the distribution of the shot noise power in each channel is proportional to the distribution of the incident optical power, which verifies that the multi-pixel BHD can achieve spectrally resolved multi-channel parallel balanced homodyne detection (Fig. 4). When the incident optical power is 1.660 mW, 0.834 mW, 0.418 mW, 0.208 mW, and 0.102 mW respectively, the shot noise spectrum and electronic noise spectrum of one pixel are measured at different analysis frequencies (Fig. 5). The test results show that the 3 dB bandwidth of MBHD is 5 MHz. The resolution bandwidth is set to 100 kHz, the video bandwidth is 100 Hz, and the number of averaging times is 10. When the incident optical power is 1.660 mW, the shot noise power is 23 dB higher than the electronic noise power at the analysis frequency of 2 MHz. By comparing the shot noise power under different incident optical power, the shot noise power decreases by 3 dB when the incident optical power decreases by half, which indicates that the detector has a good linear gain within 0.102 mW to 1.660 mW of the optical power. Conclusions Based on the noise model of the BHD, the electronic noise source is analyzed theoretically. The results indicate that the L-C coupled structure is better. By adopting the multi-pixel photodiode array and L-C coupled structure, a high-performance multi-pixel BHD is developed. In each pixel channel, when the 815 nm laser with optical power of 1.660 mW is incident, the shot noise power is 23 dB higher than the electronic noise at the analysis frequency of 2 MHz. By employing the grating to scatter the incident light horizontally, the shot noise power in each channel is proportional to the incident optical power. It is verified that the multi-pixel BHD can realize the spectrally resolved multi-channel parallel balanced homodyne detection. The detector provides a high-performance detection tool for quantum precision measurement based on quantum optical frequency comb.

Acta Optica Sinica•Jan 1, 2024•2 citations

高性能GHz带宽平衡零拍探测器的研制

段放世 Fangshi DUAN, 李超 Chao LI, 索普一 Puyi SUO +1 more

ObjectiveHigh performance balanced homodyne detectors with high bandwidth, high quantum efficiency, reasonable gain, and high common-mode rejection ratio are critical in the fields of high-speed quantum communication, broadband squeezed light and entangled light detection, and broadband quantum precision measurement. However, it is challenging to design and develop GHz bandwidth balanced homodyne detectors with overall high performance. For example, the actually achieved bandwidth and gain are usually limited by the distributed capacitance of the circuit board. Furthermore, high common-mode rejection ratio, linear response and low noise performance are also technically challenging due to fabrication and soldering processes of the printed circuit board (PCB).MethodsIn comparison with other high bandwidth balanced homodyne detectors developed in previous works, we have adopted a design that separates alternating current (AC) and direct current (DC). The DC output helps us monitor the optical power and ensures the balance of the two photodiodes, which is crucial for balanced homodyne detection in quantum optical experiments. Our circuit board design involves placing two photodiodes on opposite sides of the PCB. This makes it easier to ensure the circuit lengths of the two photodiodes are exactly the same and reduce the distributed capacitance of the circuit board. This is important for enhancing the detector bandwidth and improving the common-mode rejection ratio. Additionally, this design is more convenient for quantum optical experiment operations.Results and DiscussionsWe used two photodiodes with 95% quantum efficiency, low capacitance and dark current for our balanced homodyne detector. The DC gain of the balanced homodyne detector is 1003.6 V/W, which is at a reasonable level for optical power monitor. We also took the noise power spectra of the balanced homodyne detector at different optical powers. We demonstrate the detector response is linear at five different frequencies. An effective bandwidth of 1 GHz and a maximum signal-to-noise ratio of 12 dB were realized at 1550 nm. The common-mode rejection ratio of the homodyne detector was tested by modulating the input beam with an electro-optical modulator. By placing two photodiodes symmetrically on the front and back sides of the double-sided PCB board, a common-mode rejection ratio of 60.65 dB at 20 MHz was achieved. Subsequently, the balanced homodyne detector was used to measure 1550 nm quadrature amplitude squeezed light. Up to -2.5 dB squeezing was observed over a bandwidth range from 3.5 MHz to 71.5 MHz.ConclusionsIn this paper, we designed and developed a balanced homodyne detector with GHz bandwidth, high quantum efficiency, reasonable gain, and high common-mode rejection ratio. The results show that the balanced homodyne detector with high bandwidth and high common-mode rejection ratio are useful in broadband squeezed state measurement.

Acta Sinica Quantum Optica•Jan 1, 2025•0 citations

Balanced homodyne detection with high common mode rejection ratio based on parameter compensation of two arbitrary photodiodes

Xiaoli Jin, Jing Su, Yaohui Zheng +3 more

A balanced homodyne detector, with a maximum common mode rejection ratio and clearance of 75.2 dB and 37 dB, is experimentally obtained with two arbitrary photodiodes of the same model. On the basis of self-subtraction photodetector scheme, we divide the influence of photodiodes on the common mode rejection ratio into two parts, including magnitude and phase of output signal. The discrepancy of quantum efficiency and dark current affects magnitude of output signal of photodiodes, which is compensated by adjusting the splitter ratio. The difference of the equivalent capacitance and resistance affects the phase of output signal of photodiodes, which is compensated by the differential fine tuning circuit and adjustable bias voltage circuit. With these designs, the developed homodyne detector can be used for measuring accurately the squeezed state.

Optics Express•Sep 2, 2015•82 citations
The study, generation, and application of squeezed states of light has been a widely researched area in quantum optics. Vacuum fluctuations or photon shot noise quantified in terms of quadrature operators, impose a quantum limit on the sensitivity of quantum sensing and quantum communication systems. Thus, squeezing the quadratures reduces the quantum uncertainty in a particular quadrature. The amount of squeezing is, however, highly limited by the optics in the experiments and the performance of the balanced homodyne detection (BHD) systems employed for the detection of the squeezed states of light. In this paper, we have analytically studied the steady state, transient and noise responses of the balanced homodyne detection (BHD) circuitry by comparing two configurations i.e., a variable gain circuit with a differential amplifier and a current subtracting circuit with differential fine-tuning circuit (DFTC) and an adjustable bias (ABV). The current subtracting circuit design with DFTC and ABV has been adopted from Xiaoli et al. [1] in order to compensate for any differences in the photodiode performance characteristics in the two arms. A variable gain configuration is used to compensate for the unequal beam splitter ratio and uneven optical powers in the two arms. In order to further improve the noise performance of the system, a differential amplifier is used in the output of the variable gain configuration. A high transimpedance gain (>70 dB) and a low noise (<500nV/ √ Hz) performance can be achieved using these circuits as per our analysis.
Objective The balanced homodyne detector (BHD) is widely used in quantum noise measurement, gravitational wave detection, high-sensitivity interferometric timing measurement, continuous-variable quantum key distribution, and quantum random number generation. Highly sensitive to the amplitude and phase of the incident light, the BHD can reliably extract quantum fluctuations, suppress the classical common-mode noise, and amplify quantum fluctuations to the macro level. However, the performance of the BHD is limited by the bandwidth, signal-to-noise ratio (SNR), and common-mode rejection ratio (CMRR) of the detector. The optimal design of the BHD has always been a research hotspot. The transimpedance circuit based on a direct current (DC) coupled circuit is not suitable for detecting quantum noise. The reason is that as the power of the incident light increases, the unbalanced DC increases rapidly, and the transimpedance amplifier is saturated, which significantly reduces the dynamic range of the BHD. The BHD based on an inductor-capacitor (L-C) coupled circuit generates higher electronic noise at an analyzing frequency in the kHz range. It is not suitable for low-frequency measurements due to the parasitic effect of the inductor and the low impedance of the inductor at an analyzing frequency in the kHz range. In this paper, the noise sources of the BHD are analyzed theoretically, and a resistor-capacitor (R-C) coupled transimpedance circuit is used to improve the performance of the BHD at an analyzing frequency in the kHz range. Furthermore, the transimpedance circuit is optimized to increase the bandwidth to 200 MHz. The CMRR of the BHD is improved by designing a self-subtraction photodetector scheme, a variable optical attenuator, and an adjustable reverse bias voltage. These designs allow the BHD to meet the low-frequency and high-frequency measurements with high SNR and CMRR in quantum noise measurement. Methods To enable the BHD to measure both low-frequency and high-frequency signals with high sensitivity, this paper adopts the BHD based on an R-C coupled transimpedance circuit. Two photodiodes are connected in series, and the balanced current signal in the two photodiodes is divided into a DC signal and an alternating current (AC) signal by the R-C coupled structure. The AC signal is converted into a voltage signal by a transimpedance amplifier (TIA) and is further used to measure the shot-noise power of the incident light. The DC signal is converted into a voltage signal by a load resistor and is then used to measure the balance between the two incident lights. To reduce the crosstalk between the DC circuit and the AC circuit, an isolation amplifier is added after the load resistor. An adjustable bias voltage (BV) circuit is used to adjust the junction capacitance of the photodiodes and further improve the CMRR. To compensate for the difference in the amplitude of the two photodiodes and thereby improve the CMRR of the BHD, the paper also utilizes a variable optical attenuator based on fiber bending, where variable attenuation is achieved by changing the radius of the bent fiber. The attenuation of the fiber is precisely adjusted to balance the photocurrent. In addition, an equivalent noise model is constructed. The electronic noise from the TIA circuit includes four parts, i.e., the noise introduced by the dark current in the photodiodes, the thermal noise in the feedback resistor, the noise generated by the input current noise in the TIA, and the noise produced by the input voltage noise. On the basis of theoretical analysis, reasonable DC load resistance and feedback capacitance, photodiodes with low dark current and low junction capacitance, and a TIA with low input noise are selected to reduce the electronic noise and improve the SNR of the BHD. Results and Discussions A BHD with an R-C coupled circuit structure is designed (Fig. 1). A test device is built to test the performance of the BHD. The AC output is connected with a spectrometer to measure the bandwidth and the SNR of the BHD. The DC output is connected with an oscilloscope to make sure that the power of the two incident lights is balanced (Fig. 3). When the incident optical power is 8, 4, 2, and 1 mW, respectively, the paper tests the shot-noise spectrum and the electronic noise spectrum of the BHD with different analyzing frequencies. The test results show that the 3-dB bandwidth of the BHD is 1 kHz-200 MHz. The resolution bandwidth (RBW) and the video bandwidth (VBW) of the spectrum analyzer are set to 10 Hz and 1 Hz, respectively, and the number of averaging times is set to 40. In this case, the SNR is 12 dB at the analyzing frequency of 5 kHz under an incident optical power of 8 mW. The SNR is 20 dB at the analyzing frequency of 100 MHz when the RBW is 200 kHz and the VBW is 100 Hz. Moreover, in the analyzing frequency range of 10 kHz-200 MHz, the shot-noise power decreases by about 3 dB when the incident optical power decreases by half, indicating that the AC output of the BHD has favorable linear gain characteristics in the range of 1 mW to 8 mW (Fig. 4). In addition, 5 kHz and 100 MHz sinusoidal signals are loaded into an electro-optical amplitude modulator to modulate the incident light and thereby test the CMRR. The results show that the CMRR is 70 dB at the analyzing frequency of 5 kHz and 66 dB at the analyzing frequency of 100 MHz (Fig. 5). Conclusions By analyzing the noise sources of the BHD, adopting the R-C coupled transimpedance circuit, and optimizing the TIA circuit, this paper implements a broadband balanced homodyne detector that works in the bandwidth range from 1 kHz to 200 MHz with low noise and high CMRR. In the case of an incident optical power of 8 mW@1550 nm, the shot-noise power is 12 dB higher than the electronic noise power and the CMRR reaches 70 dB at the analyzing frequency of 5 kHz, and the shot-noise power is 20 dB higher than the electronic noise power and the CMRR reaches 66 dB at the analyzing frequency of 100 MHz. Such a homodyne detector can serve as a high-performance detection tool in various applications, such as low-frequency gravitational wave detection, high-speed continuous-variable quantum key distribution, and high-speed quantum random number generation.
This paper presents the design, construction, and performance evaluation of a balanced homodyne detector (BHD) intended for continuous-variable quantum optics applications. The system employs two closely matched IG17X500 photodiodes and a low-noise differential amplifier to suppress classical technical noise and enhance the sensitivity of quadrature measurements. Experimental tests using a 1064 nm Nd:YAG laser demonstrate strong photodiode linearity and a quantum efficiency of approximately 68%. Spectral analysis further reveals a Common-Mode Rejection Ratio (CMRR) of around 52 dB, indicating highly effective cancellation of laser-induced and electronic noise. A characteristic relaxation-oscillation peak at 284.375 kHz is observed in the unbalanced detector output but significantly reduced in the balanced output, confirming the robustness of the homodyne architecture. These results verify that the implemented BHD operates near the shot-noise limit and is well suited for applications such as squeezed-state detection, vacuum noise characterization, and precision continuous-variable quantum measurements.
The rapid development of continuous-variable quantum communication has driven an increasing demand for high-performance quantum signal processing modules. Among these, the balanced homodyne detector (BHD) has emerged as a leading solution for practical quantum state measurement due to its capability to provide complete quantum mechanical characterization. However, its performance is often constrained by limited bandwidth and high noise levels, primarily due to the reliance on bulk optical components and discrete receiver electronics. The dominant noise source in these systems typically stems from electronic noise, while imbalances in the optical path further degrade the signal-to-noise ratio (SNR) of the BHD. In this work, we present an adjustable integrated optical path to enhance the balance within the BHD system, along with a low-noise transimpedance amplifier (TIA) by employing optoelectronic co-design. Our design achieves a bandwidth of 2.5 GHz, an input-referred noise current of only 2 pA/√Hz in 180 nm CMOS technology, and a measured quantum shot noise clearance of 15 dB generated from a 700 μA photocurrent. This is the maximum quantum shot noise clearance at the same BHD photocurrent reported to date above the GHz bandwidth.
Objective As an important tool for quantum optical measurement, the balanced homodyne detector (BHD) is highly sensitive to the amplitude and phase of the incident light. It can reliably extract quantum fluctuations, suppress classical common-mode noise, and amplify quantum fluctuations to the macro level. Additionally, it has been widely employed in quantum noise measurement, gravitational wave detection, high-sensitivity interferometric timing measurement, continuous variable quantum key distribution, and quantum random number generator. The common-mode rejection ratio (CMRR), operating bandwidth, and signal-to-noise ratio (SNR) of the detector have been the research focuses. The optical frequency comb contains a large number of equally spaced longitudinal modes, which is a good multi-mode resource. The spectrum width of the optical frequency comb is in the order of nanometers. The quantum optical frequency comb which breaks the limit of shot noise can be generated by nonlinear processes. Quantum optical frequency comb has a great application prospect in quantum precision measurement. Spectrally resolved balanced homodyne detection is an important detection method of quantum optical frequency comb. We analyze the noise source of the balanced homodyne detector theoretically and design the multi-pixel balanced homodyne detector (MBHD) based on photodiode array and multi-channel inductance-capacitance (L-C) coupled transimpedance amplifier (TIA) circuit. These designs enable MBHD to meet multi-channel parallel and high-SNR quantum noise measurements. Methods The MBHD consists of two highly symmetrical multi-pixel photodetectors (MPDs) and a multi-channel subtracter (Fig. 1). Each MPD includes a photodiode array, a multi-channel L-C coupled structure, AC amplification, and DC amplification. The photocurrent generated by the corresponding pair of pixels in the two MPD flows through their respective AC amplification outputs, and the common-mode signal in the detection result is eliminated by the subtracter to complete the multi-pixel parallel balanced homodyne detection. Multi-channel DC output monitors the optical power of all pixels by a multi-function data acquisition card (DAQ). In the amplification circuit structure of the single pixel in MPD, the generated photocurrent signal is divided into DC signal and AC signal through the L-C coupled circuit. The AC signal is converted into a voltage signal by a TIA and is further adopted to measure the intensity noise power of the incident light. The DC signal is converted into a voltage signal by a load resistor and a isolation amplifier. Additionally, an equivalent noise model is built to analyze the electronic noise. Due to the multi-channel parallel structure of the MBHD, each channel is similar to each other and independent. The electronic noise of the single-pixel channel includes the noise generated by the dark current of the photodiode, the thermal noise generated by the feedback resistance in the transimpedance amplifier circuit, the noise generated by the input voltage noise of the transimpedance amplifier, and the noise generated by the input current noise of the transimpedance amplifier. Theoretical analysis shows that a reasonable selection of feedback resistance and inductance, photodiode with low dark current and low junction capacitance, and the TIA with low input noise can reduce the electronic noise of the detector. Meanwhile, the L-C coupled structure is better than the R-C coupled structure in experimental conditions (Fig. 2). Results and Discussions The device is constructed to test the performance of MBHD (Fig. 3). AC output of MBHD is connected to a spectrometer to measure the bandwidth and SNR. The DC signals of each pixel are measured by a DAQ to monitor the optical powers of each pixel. When the optical power is distributed on all pixel channels, the distribution of the shot noise power in each channel is proportional to the distribution of the incident optical power, which verifies that the multi-pixel BHD can achieve spectrally resolved multi-channel parallel balanced homodyne detection (Fig. 4). When the incident optical power is 1.660 mW, 0.834 mW, 0.418 mW, 0.208 mW, and 0.102 mW respectively, the shot noise spectrum and electronic noise spectrum of one pixel are measured at different analysis frequencies (Fig. 5). The test results show that the 3 dB bandwidth of MBHD is 5 MHz. The resolution bandwidth is set to 100 kHz, the video bandwidth is 100 Hz, and the number of averaging times is 10. When the incident optical power is 1.660 mW, the shot noise power is 23 dB higher than the electronic noise power at the analysis frequency of 2 MHz. By comparing the shot noise power under different incident optical power, the shot noise power decreases by 3 dB when the incident optical power decreases by half, which indicates that the detector has a good linear gain within 0.102 mW to 1.660 mW of the optical power. Conclusions Based on the noise model of the BHD, the electronic noise source is analyzed theoretically. The results indicate that the L-C coupled structure is better. By adopting the multi-pixel photodiode array and L-C coupled structure, a high-performance multi-pixel BHD is developed. In each pixel channel, when the 815 nm laser with optical power of 1.660 mW is incident, the shot noise power is 23 dB higher than the electronic noise at the analysis frequency of 2 MHz. By employing the grating to scatter the incident light horizontally, the shot noise power in each channel is proportional to the incident optical power. It is verified that the multi-pixel BHD can realize the spectrally resolved multi-channel parallel balanced homodyne detection. The detector provides a high-performance detection tool for quantum precision measurement based on quantum optical frequency comb.
ObjectiveHigh performance balanced homodyne detectors with high bandwidth, high quantum efficiency, reasonable gain, and high common-mode rejection ratio are critical in the fields of high-speed quantum communication, broadband squeezed light and entangled light detection, and broadband quantum precision measurement. However, it is challenging to design and develop GHz bandwidth balanced homodyne detectors with overall high performance. For example, the actually achieved bandwidth and gain are usually limited by the distributed capacitance of the circuit board. Furthermore, high common-mode rejection ratio, linear response and low noise performance are also technically challenging due to fabrication and soldering processes of the printed circuit board (PCB).MethodsIn comparison with other high bandwidth balanced homodyne detectors developed in previous works, we have adopted a design that separates alternating current (AC) and direct current (DC). The DC output helps us monitor the optical power and ensures the balance of the two photodiodes, which is crucial for balanced homodyne detection in quantum optical experiments. Our circuit board design involves placing two photodiodes on opposite sides of the PCB. This makes it easier to ensure the circuit lengths of the two photodiodes are exactly the same and reduce the distributed capacitance of the circuit board. This is important for enhancing the detector bandwidth and improving the common-mode rejection ratio. Additionally, this design is more convenient for quantum optical experiment operations.Results and DiscussionsWe used two photodiodes with 95% quantum efficiency, low capacitance and dark current for our balanced homodyne detector. The DC gain of the balanced homodyne detector is 1003.6 V/W, which is at a reasonable level for optical power monitor. We also took the noise power spectra of the balanced homodyne detector at different optical powers. We demonstrate the detector response is linear at five different frequencies. An effective bandwidth of 1 GHz and a maximum signal-to-noise ratio of 12 dB were realized at 1550 nm. The common-mode rejection ratio of the homodyne detector was tested by modulating the input beam with an electro-optical modulator. By placing two photodiodes symmetrically on the front and back sides of the double-sided PCB board, a common-mode rejection ratio of 60.65 dB at 20 MHz was achieved. Subsequently, the balanced homodyne detector was used to measure 1550 nm quadrature amplitude squeezed light. Up to -2.5 dB squeezing was observed over a bandwidth range from 3.5 MHz to 71.5 MHz.ConclusionsIn this paper, we designed and developed a balanced homodyne detector with GHz bandwidth, high quantum efficiency, reasonable gain, and high common-mode rejection ratio. The results show that the balanced homodyne detector with high bandwidth and high common-mode rejection ratio are useful in broadband squeezed state measurement.
A balanced homodyne detector, with a maximum common mode rejection ratio and clearance of 75.2 dB and 37 dB, is experimentally obtained with two arbitrary photodiodes of the same model. On the basis of self-subtraction photodetector scheme, we divide the influence of photodiodes on the common mode rejection ratio into two parts, including magnitude and phase of output signal. The discrepancy of quantum efficiency and dark current affects magnitude of output signal of photodiodes, which is compensated by adjusting the splitter ratio. The difference of the equivalent capacitance and resistance affects the phase of output signal of photodiodes, which is compensated by the differential fine tuning circuit and adjustable bias voltage circuit. With these designs, the developed homodyne detector can be used for measuring accurately the squeezed state.