Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Results in Physics

A low-noise, high-SNR and large-dynamic-range balanced homodyne detector for broadband squeezed light measurement

Jinrong Wang, Shuange Wu, Liying Hou, Chengdong Mi, Xurong Shi, Xuzhen Gao

Published Jan 18, 2024• 6 citations
Publisher

Abstract

Squeezing-based quantum metrology has been extensively applied in the field of precision measurement. Performance characteristics of squeezed light are obtained by a balanced homodyne detector. Here, we report a large dynamic range balanced homodyne detector with low-noise and high-signal-to-noise-ratio (SNR) for broadband squeezed light measurement. We perform a comprehensive theoretical analysis of the SNR in a wide bandwidth and experimentally analyze the important printed circuit board (PCB) layout and electronic components. Consequently, in the 100 MHz frequency band, the SNR and common mode rejection ratio (CMRR) rise over 12.6 dB and 55 dB, respectively, and the electronic noise is suppressed below −90 dB. The directly observed squeezing level at 1550 nm with the specified detector is 11.8 dB at 2 MHz and 3.1 dB at 100 MHz.

DOI
10.1016/j.rinp.2024.107356

Related papers

Low Noise Balanced Homodyne Detector for Quantum Noise Measurement

Shubo Lang, Shicheng Zhang, Xiaolin Li +2 more

The research of quantum noise in the interaction of laser and atoms plays a critical role in quantum optical experiments. The measurement of quantum noise is mainly based on the balanced homodyne detection method. Here, we reported a balanced homodyne detector with low noise, high gain, and high common-mode rejection ratio (CMRR) at the wavelength of 795 nm. By optimizing the selection of components and printed circuit board (PCB) layout, a minimum electronic noise of −96.7 dBm is obtained. Over the range of 1 MHz to 5 MHz, we get a flat CMRR above 59 dB and a linear gain regime, which can enable a shot noise measurement with the laser power of$100~\mu \text{w}$. The developed detector can be used in quantum coherent experiments with a weak probe laser of power down to tens of microwatts.

IEEE Access•Jan 1, 2022•4 citations

高性能GHz带宽平衡零拍探测器的研制

段放世 Fangshi DUAN, 李超 Chao LI, 索普一 Puyi SUO +1 more

ObjectiveHigh performance balanced homodyne detectors with high bandwidth, high quantum efficiency, reasonable gain, and high common-mode rejection ratio are critical in the fields of high-speed quantum communication, broadband squeezed light and entangled light detection, and broadband quantum precision measurement. However, it is challenging to design and develop GHz bandwidth balanced homodyne detectors with overall high performance. For example, the actually achieved bandwidth and gain are usually limited by the distributed capacitance of the circuit board. Furthermore, high common-mode rejection ratio, linear response and low noise performance are also technically challenging due to fabrication and soldering processes of the printed circuit board (PCB).MethodsIn comparison with other high bandwidth balanced homodyne detectors developed in previous works, we have adopted a design that separates alternating current (AC) and direct current (DC). The DC output helps us monitor the optical power and ensures the balance of the two photodiodes, which is crucial for balanced homodyne detection in quantum optical experiments. Our circuit board design involves placing two photodiodes on opposite sides of the PCB. This makes it easier to ensure the circuit lengths of the two photodiodes are exactly the same and reduce the distributed capacitance of the circuit board. This is important for enhancing the detector bandwidth and improving the common-mode rejection ratio. Additionally, this design is more convenient for quantum optical experiment operations.Results and DiscussionsWe used two photodiodes with 95% quantum efficiency, low capacitance and dark current for our balanced homodyne detector. The DC gain of the balanced homodyne detector is 1003.6 V/W, which is at a reasonable level for optical power monitor. We also took the noise power spectra of the balanced homodyne detector at different optical powers. We demonstrate the detector response is linear at five different frequencies. An effective bandwidth of 1 GHz and a maximum signal-to-noise ratio of 12 dB were realized at 1550 nm. The common-mode rejection ratio of the homodyne detector was tested by modulating the input beam with an electro-optical modulator. By placing two photodiodes symmetrically on the front and back sides of the double-sided PCB board, a common-mode rejection ratio of 60.65 dB at 20 MHz was achieved. Subsequently, the balanced homodyne detector was used to measure 1550 nm quadrature amplitude squeezed light. Up to -2.5 dB squeezing was observed over a bandwidth range from 3.5 MHz to 71.5 MHz.ConclusionsIn this paper, we designed and developed a balanced homodyne detector with GHz bandwidth, high quantum efficiency, reasonable gain, and high common-mode rejection ratio. The results show that the balanced homodyne detector with high bandwidth and high common-mode rejection ratio are useful in broadband squeezed state measurement.

Acta Sinica Quantum Optica•Jan 1, 2025•0 citations

20 MHz resonant photodetector for the homodyne measurement of picosecond pulsed squeezed light

Zhihao Li, Jun Liu, Fengjuan Guo +3 more

A high-performance resonant balanced homodyne detector is a key element for the measurement of picosecond pulsed squeezed light, which is an important quantum resource in quantum-enhanced microscopic imaging. In this paper, we design and demonstrate a resonant photodetector for homodyne measurement with a maximum signal-to-noise ratio of 22.42 dB at resonant frequency of 20 MHz. Using this detector to pulsed regime, a maximum signal-to-noise ratio at resonant frequency is 10.02 dB, where a 40 dB subtraction capability at 80 MHz repetition rate of pulsed laser is obtained. With this design, the quantum noise of picosecond pulsed squeezed light is measured and the best squeezing level −1.7 dB below the shot noise level is clearly observed at 20 MHz.

Optics Continuum•Feb 15, 2023•6 citations

Die-Level Balanced Homodyne Receiver for Squeezed Light Detection in the GHz Regime

Emmily Zaiser, Alessandro Trenti, Dinka Milovančev +3 more

Quantum receiver scalability and cost-effectiveness are crucial in the evolving quantum landscape. Application based on squeezed light (e.g. high-precision measurements and quantum communication), can profit especially from integrated and low-noise detectors. The presented die-level receiver is shown in figure 1 a) and combines a novel custom transimpedance amplifier (TIA) with commercial photodiodes (PDs) [1]. This offers a more scalable solution than bulk balanced homodyne detectors (BHDs) while being low-cost compared to fully customized receivers. This design targets a high bandwidth operation while maintaining low-noise properties for the detection of weak quantum signals. To characterize this receiver, we evaluate its performance through measurements of clearance, and common-mode rejection ratio (CMRR). Based on these parameters, a simulation for its performance in the squeezed light detection measurement is presented.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 23, 2025•1 citation

A low-noise, high-SNR balanced homodyne detector for the bright squeezed state measurement in 1–100 kHz range*

JinRong Wang, Qing-Wei Wang, Long Tian +2 more

We report a low-noise, high-signal-to-noise-ratio (SNR) balanced homodyne detector based on the standard transimpedance amplifier circuit and the inductance and capacitance combination for the measurement of the bright squeezed state in the range from 1 kHz to 100 kHz. A capacitance is mounted at the input end of the AC branch to prevent the DC photocurrent from entering the AC branch and avoid AC branch saturation. By adding a switch at the DC branch, the DC branch can be flexibly turned on and off on different occasions. When the switch is on, the DC output provides a monitor signal for laser beam alignment. When the switch is off, the electronic noise of the AC branch is greatly reduced at audio-frequency band due to immunity to the impedance of the DC branch, hence the SNR of the AC branch is significantly improved. As a result, the electronic noise of the AC branch is close to −125 dBm, and the maximum SNR of the AC branch is 48 dB with the incident power of 8 mW in the range from 1 kHz to 100 kHz. The developed photodetector paves a path for measuring the bright squeezed state at audio-frequency band.

Chinese Physics B•Jan 7, 2020•15 citations

STUDY OF A BALANCED HOMODYNE DETECTOR WITH HIGH COMMON-MODE NOISE SUPPRESSION FOR QUANTUM OPTICS EXPERIMENTS

ThS. Nguyễn Thị Hiền, ThS. Hùynh Đức Chấn

This paper presents the design, construction, and performance evaluation of a balanced homodyne detector (BHD) intended for continuous-variable quantum optics applications. The system employs two closely matched IG17X500 photodiodes and a low-noise differential amplifier to suppress classical technical noise and enhance the sensitivity of quadrature measurements. Experimental tests using a 1064 nm Nd:YAG laser demonstrate strong photodiode linearity and a quantum efficiency of approximately 68%. Spectral analysis further reveals a Common-Mode Rejection Ratio (CMRR) of around 52 dB, indicating highly effective cancellation of laser-induced and electronic noise. A characteristic relaxation-oscillation peak at 284.375 kHz is observed in the unbalanced detector output but significantly reduced in the balanced output, confirming the robustness of the homodyne architecture. These results verify that the implemented BHD operates near the shot-noise limit and is well suited for applications such as squeezed-state detection, vacuum noise characterization, and precision continuous-variable quantum measurements.

Tạp chí Khoa học và Công nghệ- Đại học Công nghệ Đồng Nai•Jul 21, 2026•0 citations
Squeezing-based quantum metrology has been extensively applied in the field of precision measurement. Performance characteristics of squeezed light are obtained by a balanced homodyne detector. Here, we report a large dynamic range balanced homodyne detector with low-noise and high-signal-to-noise-ratio (SNR) for broadband squeezed light measurement. We perform a comprehensive theoretical analysis of the SNR in a wide bandwidth and experimentally analyze the important printed circuit board (PCB) layout and electronic components. Consequently, in the 100 MHz frequency band, the SNR and common mode rejection ratio (CMRR) rise over 12.6 dB and 55 dB, respectively, and the electronic noise is suppressed below −90 dB. The directly observed squeezing level at 1550 nm with the specified detector is 11.8 dB at 2 MHz and 3.1 dB at 100 MHz.
The research of quantum noise in the interaction of laser and atoms plays a critical role in quantum optical experiments. The measurement of quantum noise is mainly based on the balanced homodyne detection method. Here, we reported a balanced homodyne detector with low noise, high gain, and high common-mode rejection ratio (CMRR) at the wavelength of 795 nm. By optimizing the selection of components and printed circuit board (PCB) layout, a minimum electronic noise of −96.7 dBm is obtained. Over the range of 1 MHz to 5 MHz, we get a flat CMRR above 59 dB and a linear gain regime, which can enable a shot noise measurement with the laser power of100 μw100~\mu \text{w}100 μw. The developed detector can be used in quantum coherent experiments with a weak probe laser of power down to tens of microwatts.
ObjectiveHigh performance balanced homodyne detectors with high bandwidth, high quantum efficiency, reasonable gain, and high common-mode rejection ratio are critical in the fields of high-speed quantum communication, broadband squeezed light and entangled light detection, and broadband quantum precision measurement. However, it is challenging to design and develop GHz bandwidth balanced homodyne detectors with overall high performance. For example, the actually achieved bandwidth and gain are usually limited by the distributed capacitance of the circuit board. Furthermore, high common-mode rejection ratio, linear response and low noise performance are also technically challenging due to fabrication and soldering processes of the printed circuit board (PCB).MethodsIn comparison with other high bandwidth balanced homodyne detectors developed in previous works, we have adopted a design that separates alternating current (AC) and direct current (DC). The DC output helps us monitor the optical power and ensures the balance of the two photodiodes, which is crucial for balanced homodyne detection in quantum optical experiments. Our circuit board design involves placing two photodiodes on opposite sides of the PCB. This makes it easier to ensure the circuit lengths of the two photodiodes are exactly the same and reduce the distributed capacitance of the circuit board. This is important for enhancing the detector bandwidth and improving the common-mode rejection ratio. Additionally, this design is more convenient for quantum optical experiment operations.Results and DiscussionsWe used two photodiodes with 95% quantum efficiency, low capacitance and dark current for our balanced homodyne detector. The DC gain of the balanced homodyne detector is 1003.6 V/W, which is at a reasonable level for optical power monitor. We also took the noise power spectra of the balanced homodyne detector at different optical powers. We demonstrate the detector response is linear at five different frequencies. An effective bandwidth of 1 GHz and a maximum signal-to-noise ratio of 12 dB were realized at 1550 nm. The common-mode rejection ratio of the homodyne detector was tested by modulating the input beam with an electro-optical modulator. By placing two photodiodes symmetrically on the front and back sides of the double-sided PCB board, a common-mode rejection ratio of 60.65 dB at 20 MHz was achieved. Subsequently, the balanced homodyne detector was used to measure 1550 nm quadrature amplitude squeezed light. Up to -2.5 dB squeezing was observed over a bandwidth range from 3.5 MHz to 71.5 MHz.ConclusionsIn this paper, we designed and developed a balanced homodyne detector with GHz bandwidth, high quantum efficiency, reasonable gain, and high common-mode rejection ratio. The results show that the balanced homodyne detector with high bandwidth and high common-mode rejection ratio are useful in broadband squeezed state measurement.
A high-performance resonant balanced homodyne detector is a key element for the measurement of picosecond pulsed squeezed light, which is an important quantum resource in quantum-enhanced microscopic imaging. In this paper, we design and demonstrate a resonant photodetector for homodyne measurement with a maximum signal-to-noise ratio of 22.42 dB at resonant frequency of 20 MHz. Using this detector to pulsed regime, a maximum signal-to-noise ratio at resonant frequency is 10.02 dB, where a 40 dB subtraction capability at 80 MHz repetition rate of pulsed laser is obtained. With this design, the quantum noise of picosecond pulsed squeezed light is measured and the best squeezing level −1.7 dB below the shot noise level is clearly observed at 20 MHz.
Quantum receiver scalability and cost-effectiveness are crucial in the evolving quantum landscape. Application based on squeezed light (e.g. high-precision measurements and quantum communication), can profit especially from integrated and low-noise detectors. The presented die-level receiver is shown in figure 1 a) and combines a novel custom transimpedance amplifier (TIA) with commercial photodiodes (PDs) [1]. This offers a more scalable solution than bulk balanced homodyne detectors (BHDs) while being low-cost compared to fully customized receivers. This design targets a high bandwidth operation while maintaining low-noise properties for the detection of weak quantum signals. To characterize this receiver, we evaluate its performance through measurements of clearance, and common-mode rejection ratio (CMRR). Based on these parameters, a simulation for its performance in the squeezed light detection measurement is presented.
We report a low-noise, high-signal-to-noise-ratio (SNR) balanced homodyne detector based on the standard transimpedance amplifier circuit and the inductance and capacitance combination for the measurement of the bright squeezed state in the range from 1 kHz to 100 kHz. A capacitance is mounted at the input end of the AC branch to prevent the DC photocurrent from entering the AC branch and avoid AC branch saturation. By adding a switch at the DC branch, the DC branch can be flexibly turned on and off on different occasions. When the switch is on, the DC output provides a monitor signal for laser beam alignment. When the switch is off, the electronic noise of the AC branch is greatly reduced at audio-frequency band due to immunity to the impedance of the DC branch, hence the SNR of the AC branch is significantly improved. As a result, the electronic noise of the AC branch is close to −125 dBm, and the maximum SNR of the AC branch is 48 dB with the incident power of 8 mW in the range from 1 kHz to 100 kHz. The developed photodetector paves a path for measuring the bright squeezed state at audio-frequency band.
This paper presents the design, construction, and performance evaluation of a balanced homodyne detector (BHD) intended for continuous-variable quantum optics applications. The system employs two closely matched IG17X500 photodiodes and a low-noise differential amplifier to suppress classical technical noise and enhance the sensitivity of quadrature measurements. Experimental tests using a 1064 nm Nd:YAG laser demonstrate strong photodiode linearity and a quantum efficiency of approximately 68%. Spectral analysis further reveals a Common-Mode Rejection Ratio (CMRR) of around 52 dB, indicating highly effective cancellation of laser-induced and electronic noise. A characteristic relaxation-oscillation peak at 284.375 kHz is observed in the unbalanced detector output but significantly reduced in the balanced output, confirming the robustness of the homodyne architecture. These results verify that the implemented BHD operates near the shot-noise limit and is well suited for applications such as squeezed-state detection, vacuum noise characterization, and precision continuous-variable quantum measurements.