Results in Physics

A low-noise, high-SNR and large-dynamic-range balanced homodyne detector for broadband squeezed light measurement

Jinrong Wang, Shuange Wu, Liying Hou, Chengdong Mi, Xurong Shi, Xuzhen Gao

Published Jan 18, 2024• 5 citations
Publisher

Abstract

Squeezing-based quantum metrology has been extensively applied in the field of precision measurement. Performance characteristics of squeezed light are obtained by a balanced homodyne detector. Here, we report a large dynamic range balanced homodyne detector with low-noise and high-signal-to-noise-ratio (SNR) for broadband squeezed light measurement. We perform a comprehensive theoretical analysis of the SNR in a wide bandwidth and experimentally analyze the important printed circuit board (PCB) layout and electronic components. Consequently, in the 100 MHz frequency band, the SNR and common mode rejection ratio (CMRR) rise over 12.6 dB and 55 dB, respectively, and the electronic noise is suppressed below -90 dB. The directly observed squeezing level at 1550 nm with the specified detector is 11.8 dB at 2 MHz and 3.1 dB at 100 MHz.

DOI
10.1016/j.rinp.2024.107356

Related papers

Low Noise Balanced Homodyne Detector for Quantum Noise Measurement

Shubo Lang, Shicheng Zhang, Xiaolin Li +2 more

The research of quantum noise in the interaction of laser and atoms plays a critical role in quantum optical experiments. The measurement of quantum noise is mainly based on the balanced homodyne detection method. Here, we reported a balanced homodyne detector with low noise, high gain, and high common-mode rejection ratio (CMRR) at the wavelength of 795 nm. By optimizing the selection of components and printed circuit board (PCB) layout, a minimum electronic noise of −96.7 dBm is obtained. Over the range of 1 MHz to 5 MHz, we get a flat CMRR above 59 dB and a linear gain regime, which can enable a shot noise measurement with the laser power of$100~\mu \text{w}$. The developed detector can be used in quantum coherent experiments with a weak probe laser of power down to tens of microwatts.

IEEE Access•Jan 1, 2022•4 citations

20 MHz resonant photodetector for the homodyne measurement of picosecond pulsed squeezed light

Zhihao Li, Jun Liu, Fengjuan Guo +3 more

A high-performance resonant balanced homodyne detector is a key element for the measurement of picosecond pulsed squeezed light, which is an important quantum resource in quantum-enhanced microscopic imaging. In this paper, we design and demonstrate a resonant photodetector for homodyne measurement with a maximum signal-to-noise ratio of 22.42 dB at resonant frequency of 20 MHz. Using this detector to pulsed regime, a maximum signal-to-noise ratio at resonant frequency is 10.02 dB, where a 40 dB subtraction capability at 80 MHz repetition rate of pulsed laser is obtained. With this design, the quantum noise of picosecond pulsed squeezed light is measured and the best squeezing level −1.7 dB below the shot noise level is clearly observed at 20 MHz.

Optics Continuum•Feb 1, 2023•6 citations

Die-Level Balanced Homodyne Receiver for Squeezed Light Detection in the GHz Regime

Emmily Zaiser, Alessandro Trenti, Dinka Milovančev +3 more

Quantum receiver scalability and cost-effectiveness are crucial in the evolving quantum landscape. Application based on squeezed light (e.g. high-precision measurements and quantum communication), can profit especially from integrated and low-noise detectors. The presented die-level receiver is shown in figure 1 a) and combines a novel custom transimpedance amplifier (TIA) with commercial photodiodes (PDs) [1]. This offers a more scalable solution than bulk balanced homodyne detectors (BHDs) while being low-cost compared to fully customized receivers. This design targets a high bandwidth operation while maintaining low-noise properties for the detection of weak quantum signals. To characterize this receiver, we evaluate its performance through measurements of clearance, and common-mode rejection ratio (CMRR). Based on these parameters, a simulation for its performance in the squeezed light detection measurement is presented.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 23, 2025•0 citations

A low-noise, high-SNR balanced homodyne detector for the bright squeezed state measurement in 1–100 kHz range*

JinRong Wang, Qing-Wei Wang, Long Tian +2 more

We report a low-noise, high-signal-to-noise-ratio (SNR) balanced homodyne detector based on the standard transimpedance amplifier circuit and the inductance and capacitance combination for the measurement of the bright squeezed state in the range from 1 kHz to 100 kHz. A capacitance is mounted at the input end of the AC branch to prevent the DC photocurrent from entering the AC branch and avoid AC branch saturation. By adding a switch at the DC branch, the DC branch can be flexibly turned on and off on different occasions. When the switch is on, the DC output provides a monitor signal for laser beam alignment. When the switch is off, the electronic noise of the AC branch is greatly reduced at audio-frequency band due to immunity to the impedance of the DC branch, hence the SNR of the AC branch is significantly improved. As a result, the electronic noise of the AC branch is close to −125 dBm, and the maximum SNR of the AC branch is 48 dB with the incident power of 8 mW in the range from 1 kHz to 100 kHz. The developed photodetector paves a path for measuring the bright squeezed state at audio-frequency band.

Chinese Physics B•Jan 7, 2020•14 citations

High-Bandwidth Intensity-Difference Squeezed State at 895 nm Based on Four-Wave Mixing

Rong Ma, Wen Zhang, Xiaowei Wu +2 more

As an essential quantum resource, the intensity-difference squeezed state based on four-wave mixing (FWM) in atomic vapor is widely applied in quantum information processing. In particular, a high intensity-difference squeezing bandwidth is vital for the realization of high-speed information processing. However, limited by the bandwidth of photodetectors, broadband intensity-difference squeezed state based on this system has not yet been reported. Here, we developed a transimpedance broadband balanced homodyne detector at 895 nm, achieving a bandwidth greater than 100 MHz and a maximum signal-to-noise ratio of 15 dB with 4 mW optical power. Utilizing this detector in a nondegenerate FWM process based on cesium vapor, we experimentally achieved broadband intensity-difference squeezing with a bandwidth of 100 MHz, which yielded a maximum squeezing of −7.17 ± 0.8 dB between 20 and 40 MHz. Meanwhile, using this detector, we experimentally investigated the cavity-enhanced FWM process, achieving a squeezing level of −6.07 ± 0.5 dB within a 4 MHz frequency range, which is limited by the cavity bandwidth. This work provides a reliable detection tool and experimental foundation for the research and application of broadband squeezed light sources based on FWM.

Photonics•Oct 30, 2025•3 citations

A 600 MHz Balanced Homodyne Detector for Quantum Information Processing

Tianxiang Zhang, Yundi Huang, Xiangyu Wang +2 more

Balanced homodyne detector (BHD) has been widely used in quantum information processing. In this paper, we design a wide bandwidth BHD and implement an optical layout to test the performance of our BHD. The test results show that the bandwidth is about 600 MHz, the quantum to classical noise ratio (QCNR) is 15.2 dB and the common mode rejection ratio (CMRR) is 41.16 dB. The performance of BHD shows that it can meet the requirements of high-speed applications in quantum information processing.

Advances in Engineering Technology Research•May 13, 2022•0 citations
Squeezing-based quantum metrology has been extensively applied in the field of precision measurement. Performance characteristics of squeezed light are obtained by a balanced homodyne detector. Here, we report a large dynamic range balanced homodyne detector with low-noise and high-signal-to-noise-ratio (SNR) for broadband squeezed light measurement. We perform a comprehensive theoretical analysis of the SNR in a wide bandwidth and experimentally analyze the important printed circuit board (PCB) layout and electronic components. Consequently, in the 100 MHz frequency band, the SNR and common mode rejection ratio (CMRR) rise over 12.6 dB and 55 dB, respectively, and the electronic noise is suppressed below -90 dB. The directly observed squeezing level at 1550 nm with the specified detector is 11.8 dB at 2 MHz and 3.1 dB at 100 MHz.
The research of quantum noise in the interaction of laser and atoms plays a critical role in quantum optical experiments. The measurement of quantum noise is mainly based on the balanced homodyne detection method. Here, we reported a balanced homodyne detector with low noise, high gain, and high common-mode rejection ratio (CMRR) at the wavelength of 795 nm. By optimizing the selection of components and printed circuit board (PCB) layout, a minimum electronic noise of −96.7 dBm is obtained. Over the range of 1 MHz to 5 MHz, we get a flat CMRR above 59 dB and a linear gain regime, which can enable a shot noise measurement with the laser power of100 μw100~\mu \text{w}100 μw. The developed detector can be used in quantum coherent experiments with a weak probe laser of power down to tens of microwatts.
A high-performance resonant balanced homodyne detector is a key element for the measurement of picosecond pulsed squeezed light, which is an important quantum resource in quantum-enhanced microscopic imaging. In this paper, we design and demonstrate a resonant photodetector for homodyne measurement with a maximum signal-to-noise ratio of 22.42 dB at resonant frequency of 20 MHz. Using this detector to pulsed regime, a maximum signal-to-noise ratio at resonant frequency is 10.02 dB, where a 40 dB subtraction capability at 80 MHz repetition rate of pulsed laser is obtained. With this design, the quantum noise of picosecond pulsed squeezed light is measured and the best squeezing level −1.7 dB below the shot noise level is clearly observed at 20 MHz.
Quantum receiver scalability and cost-effectiveness are crucial in the evolving quantum landscape. Application based on squeezed light (e.g. high-precision measurements and quantum communication), can profit especially from integrated and low-noise detectors. The presented die-level receiver is shown in figure 1 a) and combines a novel custom transimpedance amplifier (TIA) with commercial photodiodes (PDs) [1]. This offers a more scalable solution than bulk balanced homodyne detectors (BHDs) while being low-cost compared to fully customized receivers. This design targets a high bandwidth operation while maintaining low-noise properties for the detection of weak quantum signals. To characterize this receiver, we evaluate its performance through measurements of clearance, and common-mode rejection ratio (CMRR). Based on these parameters, a simulation for its performance in the squeezed light detection measurement is presented.
We report a low-noise, high-signal-to-noise-ratio (SNR) balanced homodyne detector based on the standard transimpedance amplifier circuit and the inductance and capacitance combination for the measurement of the bright squeezed state in the range from 1 kHz to 100 kHz. A capacitance is mounted at the input end of the AC branch to prevent the DC photocurrent from entering the AC branch and avoid AC branch saturation. By adding a switch at the DC branch, the DC branch can be flexibly turned on and off on different occasions. When the switch is on, the DC output provides a monitor signal for laser beam alignment. When the switch is off, the electronic noise of the AC branch is greatly reduced at audio-frequency band due to immunity to the impedance of the DC branch, hence the SNR of the AC branch is significantly improved. As a result, the electronic noise of the AC branch is close to −125 dBm, and the maximum SNR of the AC branch is 48 dB with the incident power of 8 mW in the range from 1 kHz to 100 kHz. The developed photodetector paves a path for measuring the bright squeezed state at audio-frequency band.
As an essential quantum resource, the intensity-difference squeezed state based on four-wave mixing (FWM) in atomic vapor is widely applied in quantum information processing. In particular, a high intensity-difference squeezing bandwidth is vital for the realization of high-speed information processing. However, limited by the bandwidth of photodetectors, broadband intensity-difference squeezed state based on this system has not yet been reported. Here, we developed a transimpedance broadband balanced homodyne detector at 895 nm, achieving a bandwidth greater than 100 MHz and a maximum signal-to-noise ratio of 15 dB with 4 mW optical power. Utilizing this detector in a nondegenerate FWM process based on cesium vapor, we experimentally achieved broadband intensity-difference squeezing with a bandwidth of 100 MHz, which yielded a maximum squeezing of −7.17 ± 0.8 dB between 20 and 40 MHz. Meanwhile, using this detector, we experimentally investigated the cavity-enhanced FWM process, achieving a squeezing level of −6.07 ± 0.5 dB within a 4 MHz frequency range, which is limited by the cavity bandwidth. This work provides a reliable detection tool and experimental foundation for the research and application of broadband squeezed light sources based on FWM.