Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

International Conference on Optoelectronic Information and Optical Engineering (OIOE)

Design and optimization of a miniature physics package for coherent population trapping atomic clocks

Wei Ding, Shilong Jin, Jingpeng Ma, Lufeng Che

Published Jun 5, 2026• 0 citations
Publisher

Abstract

To improve the performance and integration of chip-scale CPT atomic clocks, this work focuses on optimizing key VCSEL parameters and implementing a miniature physics package. A high-stability VCSEL control module was developed, achieving current ripple below 2 μA and temperature stability better than 0.1 °C. Based on systematic measurements of cesium Doppler absorption spectra under varying operational conditions, the optimal VCSEL settings were identified as: 70.6 °C temperature, 1.3 mA to 1.9 mA drive current, and 10 dBm microwave modulation power— conditions that maximize the amplitude of the ±1st-order sideband absorption peaks. Guided by these results, a compact physics package was integrated, incorporating a VCSEL, MEMS cesium vapor cell, photodetector, and other components. A vertical coaxial optical layout, combined with a modular mechanical assembly, enabled precise and rapid optical alignment while minimizing footprint. Using parallel seam welding for hermetic sealing enabled a highly compact physics package with a total volume under 5.6 cm³. Doppler absorption peaks were successfully measured from this miniature physics package, demonstrating its optical functionality. Quantitative comparison with a desktop prototype reveals that this miniaturization enhances spectroscopic performance, yielding a 9 dB improvement in SNR (to 46 dB) and an 8-fold reduction in noise floor. This approach provides a robust technical foundation for chip-scale CPT atomic clocks with high frequency stability.

DOI
10.1117/12.3116259

Related papers

CPT chip-scale atomic clock with direct-modulation chip-external cavity diode laser

Jiqing Lian, Jie Miao, Tian Zhao +7 more

Chip-scale atomic clocks are critical for applications requiring compact, energy-efficient, and highly stable timing, such as GPS receivers and communication systems. Coherent population trapping (CPT)-based atomic clocks, which commonly use vertical-cavity surface-emitting lasers (VCSELs), have enabled significant miniaturization. However, their precision is limited by the broad linewidth of VCSELs. Alternative laser technologies, such as distributed Bragg reflector lasers, distributed feedback lasers, and external cavity diode lasers (ECDLs), offer potential improvements but face challenges in achieving compact size and adequate modulation bandwidth. This study presents a 795 nm chip-ECDL with a direct modulation bandwidth up to 4 GHz, specifically designed for CPT chip-scale atomic clocks. Based on the chip-ECDL, a CPT atomic clock with a compact volume of 19.4 ml and power consumption of 1.5 W has been developed. Under identical operating conditions, the CPT signal produced by the chip-ECDL exhibits a 34% reduction in linewidth and a 1.14-fold increase in contrast compared to a VCSEL-based clock. Demonstrating short-term stability better than 5×10−11τ−1/2(1 s<τ<2000 s) and reaching a best stability of 6.6×10−13 at 2000 s, this work represents the application of an ECDL in a CPT chip-scale clock, advancing the development of next-generation, high-performance chip-scale atomic clocks.

Applied Physics Letters•Jun 2, 2025•11 citations

Microfabricated Atomic Clocks at NIST

Svenja A. Knappe, Peter D. D. Schwindt, Vladislav P. Gerginov +5 more

This paper presents the latest progress in the development, fabrication, and characterization of microfabricated atomic frequency references at NIST. With volumes below 10 mm3 the physics packages contain the complete integrated assembly for probing the ground-state hyperfine splitting frequency of the alkali atoms by coherent population trapping (CPT). This technique allows for a simple and compact device containing a vertical-cavity surface-emitting laser (VCSEL), optics to shape the laser beam, a vapor cell containing the atoms, and a detector. We present an improved technique for microfabricating the miniature alkali vapor cells. When integrated into a CPT clock, a clear reduction of long-term frequency drifts is observed. This leads to a fractional frequency instability of less than 10-11 at one hour of integration, a more than one order of magnitude improvement over previous results. We identify the remaining sensitivities of the clock frequency to environmental influences and propose ways to reduce them.

•Dec 1, 2004•3 citations

Integrated physics package of a chip-scale atomic clock

Shao-Liang Li, Jing Chao Xu, Zhiqiang Zhang +3 more

The physics package of a chip-scale atomic clock (CSAC) has been successfully realized by integrating vertical cavity surface emitting laser (VCSEL), neutral density (ND) filter, λ/4 wave plate, 87 Rb vapor cell, photodiode (PD), and magnetic coil into a cuboid metal package with a volume of about 2.8 cm 3 . In this physics package, the critical component, 87 Rb vapor cell, is batch-fabricated based on MEMS technology and in-situ chemical reaction method. Pt heater and thermistors are integrated in the physics package. A PTFE pillar is used to support the optical elements in the physics package, in order to reduce the power dissipation. The optical absorption spectrum of 87 Rb D1 line and the microwave frequency correction signal are successfully observed while connecting the package with the servo circuit system. Using the above mentioned packaging solution, a CSAC with short-term frequency stability of about 7 × 10 −10 τ −1/2 has been successfully achieved, which demonstrates that this physics package would become one promising solution for the CSAC.

Chinese Physics B•Jul 1, 2014•17 citations

VCSELs for atomic clocks

Darwin K. Serkland, Gregory M. Peake, K.M. Geib +4 more

The spectroscopic technique of coherent population trapping (CPT) enables an all-optical interrogation of the groundstate hyperfine splitting of cesium (or rubidium), compared to the optical-microwave double resonance technique conventionally employed in atomic frequency standards. All-optical interrogation enables the reduction of the size and power consumption of an atomic clock by two orders of magnitude, and vertical-cavity surface-emitting lasers (VCSELs) are preferred optical sources due to their low power consumption and circular output beam. Several research teams are currently using VCSELs for DARPA's chip-scale atomic clock (CSAC) program with the goal of producing an atomic clock having a volume < 1 cm^3, a power consumption < 30 mW, and an instability (Allan deviation) < 1x10^-11 during a 1-hour averaging interval. This paper describes the VCSEL requirements for CPT-based atomic clocks, which include single mode operation, single polarization operation, modulation bandwidth > 4 GHz, low power consumption (for the CSAC), narrow linewidth, and low relative intensity noise (RIN). A significant manufacturing challenge is to reproducibly obtain the required wavelength at the specified VCSEL operating temperature and drive current. Data are presented that show the advantage of operating at the D1 (rather than D2) resonance of the alkali atoms. Measurements of VCSEL linewidth will be discussed in particular, since atomic clock performance is especially sensitive to this parameter.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Feb 9, 2006•78 citations

The Chip-Scale Atomic Clock - Recent Development Progress

Robert Lutwak, Donald A. Emmons, Thomas C. English +1 more

We have undertaken the development of a chip-scale atomic clock (CSAC) whose design goals include short-term stability, sigma(sub y)(tau=1 hour), of 1x10(exp 11) with a total power consumption of 30 mW and an overall device volume of 1 cu cm. The stringent power requirement dominates the physics package architecture, dictating a small (<5 mm(exp 3) gaseous atomic ensemble interrogated by a low-power semiconductor laser. At PTTI 2002, we reported on initial experimental investigations leading to the decision to employ the coherent population trapping (CPT) interrogation technique. This paper describes our further progress on the CSAC effort, including the development of custom vertical cavity surface emitting laser (VCSEL) sources and techniques for microfabricating miniature cesium vapor cells comprised of anodically bonded silicon and glass. Measurements of the signal contrast and linewidth of both the cesium D1 and D2 resonance transitions are compared, and frequency stability measurements of the CSAC testbed are presented.

•Sep 1, 2004•71 citations

Performance of a prototype atomic clock based on lin‖lin coherent population trapping resonances in Rb atomic vapor

Eugeniy E. Mikhailov, Travis Horrom, Nathan Belcher +1 more

We report on the performance of the first table-top prototype atomic clock based on coherent population trapping (CPT) resonances with parallel linearly polarized optical fields (lin‖lin configuration). Our apparatus uses a vertical-cavity surface-emitting laser (VCSEL) tuned to the D1 line of 87Rb with the current modulation at the 87Rb hyperfine frequency. We demonstrate cancellation of the first-order light shift by the proper choice of rf modulation power and further improve our prototype clock stability by optimizing the parameters of the microwave lock loop. Operating in these optimal conditions, we measured a short-term fractional frequency stability (Allan deviation) 2×10−11τ−1/2 for observation times 1 s ≤ τ ≤ 20 s. This value is limited by large VCSEL phase noise and environmental temperature fluctuation. Further improvements in frequency stability should be possible with an apparatus designed as a dedicated lin‖lin CPT resonance clock with environmental impacts minimized.

arXiv:0910.5881•Journal of the Optical Society of America B•Feb 4, 2010•62 citations
To improve the performance and integration of chip-scale CPT atomic clocks, this work focuses on optimizing key VCSEL parameters and implementing a miniature physics package. A high-stability VCSEL control module was developed, achieving current ripple below 2 μA and temperature stability better than 0.1 °C. Based on systematic measurements of cesium Doppler absorption spectra under varying operational conditions, the optimal VCSEL settings were identified as: 70.6 °C temperature, 1.3 mA to 1.9 mA drive current, and 10 dBm microwave modulation power— conditions that maximize the amplitude of the ±1st-order sideband absorption peaks. Guided by these results, a compact physics package was integrated, incorporating a VCSEL, MEMS cesium vapor cell, photodetector, and other components. A vertical coaxial optical layout, combined with a modular mechanical assembly, enabled precise and rapid optical alignment while minimizing footprint. Using parallel seam welding for hermetic sealing enabled a highly compact physics package with a total volume under 5.6 cm³. Doppler absorption peaks were successfully measured from this miniature physics package, demonstrating its optical functionality. Quantitative comparison with a desktop prototype reveals that this miniaturization enhances spectroscopic performance, yielding a 9 dB improvement in SNR (to 46 dB) and an 8-fold reduction in noise floor. This approach provides a robust technical foundation for chip-scale CPT atomic clocks with high frequency stability.
Chip-scale atomic clocks are critical for applications requiring compact, energy-efficient, and highly stable timing, such as GPS receivers and communication systems. Coherent population trapping (CPT)-based atomic clocks, which commonly use vertical-cavity surface-emitting lasers (VCSELs), have enabled significant miniaturization. However, their precision is limited by the broad linewidth of VCSELs. Alternative laser technologies, such as distributed Bragg reflector lasers, distributed feedback lasers, and external cavity diode lasers (ECDLs), offer potential improvements but face challenges in achieving compact size and adequate modulation bandwidth. This study presents a 795 nm chip-ECDL with a direct modulation bandwidth up to 4 GHz, specifically designed for CPT chip-scale atomic clocks. Based on the chip-ECDL, a CPT atomic clock with a compact volume of 19.4 ml and power consumption of 1.5 W has been developed. Under identical operating conditions, the CPT signal produced by the chip-ECDL exhibits a 34% reduction in linewidth and a 1.14-fold increase in contrast compared to a VCSEL-based clock. Demonstrating short-term stability better than 5×10−11τ−1/2(1 s<τ<2000 s) and reaching a best stability of 6.6×10−13 at 2000 s, this work represents the application of an ECDL in a CPT chip-scale clock, advancing the development of next-generation, high-performance chip-scale atomic clocks.
This paper presents the latest progress in the development, fabrication, and characterization of microfabricated atomic frequency references at NIST. With volumes below 10 mm3 the physics packages contain the complete integrated assembly for probing the ground-state hyperfine splitting frequency of the alkali atoms by coherent population trapping (CPT). This technique allows for a simple and compact device containing a vertical-cavity surface-emitting laser (VCSEL), optics to shape the laser beam, a vapor cell containing the atoms, and a detector. We present an improved technique for microfabricating the miniature alkali vapor cells. When integrated into a CPT clock, a clear reduction of long-term frequency drifts is observed. This leads to a fractional frequency instability of less than 10-11 at one hour of integration, a more than one order of magnitude improvement over previous results. We identify the remaining sensitivities of the clock frequency to environmental influences and propose ways to reduce them.
The physics package of a chip-scale atomic clock (CSAC) has been successfully realized by integrating vertical cavity surface emitting laser (VCSEL), neutral density (ND) filter, λ/4 wave plate, 87 Rb vapor cell, photodiode (PD), and magnetic coil into a cuboid metal package with a volume of about 2.8 cm 3 . In this physics package, the critical component, 87 Rb vapor cell, is batch-fabricated based on MEMS technology and in-situ chemical reaction method. Pt heater and thermistors are integrated in the physics package. A PTFE pillar is used to support the optical elements in the physics package, in order to reduce the power dissipation. The optical absorption spectrum of 87 Rb D1 line and the microwave frequency correction signal are successfully observed while connecting the package with the servo circuit system. Using the above mentioned packaging solution, a CSAC with short-term frequency stability of about 7 × 10 −10 τ −1/2 has been successfully achieved, which demonstrates that this physics package would become one promising solution for the CSAC.
The spectroscopic technique of coherent population trapping (CPT) enables an all-optical interrogation of the groundstate hyperfine splitting of cesium (or rubidium), compared to the optical-microwave double resonance technique conventionally employed in atomic frequency standards. All-optical interrogation enables the reduction of the size and power consumption of an atomic clock by two orders of magnitude, and vertical-cavity surface-emitting lasers (VCSELs) are preferred optical sources due to their low power consumption and circular output beam. Several research teams are currently using VCSELs for DARPA's chip-scale atomic clock (CSAC) program with the goal of producing an atomic clock having a volume < 1 cm^3, a power consumption < 30 mW, and an instability (Allan deviation) < 1x10^-11 during a 1-hour averaging interval. This paper describes the VCSEL requirements for CPT-based atomic clocks, which include single mode operation, single polarization operation, modulation bandwidth > 4 GHz, low power consumption (for the CSAC), narrow linewidth, and low relative intensity noise (RIN). A significant manufacturing challenge is to reproducibly obtain the required wavelength at the specified VCSEL operating temperature and drive current. Data are presented that show the advantage of operating at the D1 (rather than D2) resonance of the alkali atoms. Measurements of VCSEL linewidth will be discussed in particular, since atomic clock performance is especially sensitive to this parameter.
We have undertaken the development of a chip-scale atomic clock (CSAC) whose design goals include short-term stability, sigma(sub y)(tau=1 hour), of 1x10(exp 11) with a total power consumption of 30 mW and an overall device volume of 1 cu cm. The stringent power requirement dominates the physics package architecture, dictating a small (<5 mm(exp 3) gaseous atomic ensemble interrogated by a low-power semiconductor laser. At PTTI 2002, we reported on initial experimental investigations leading to the decision to employ the coherent population trapping (CPT) interrogation technique. This paper describes our further progress on the CSAC effort, including the development of custom vertical cavity surface emitting laser (VCSEL) sources and techniques for microfabricating miniature cesium vapor cells comprised of anodically bonded silicon and glass. Measurements of the signal contrast and linewidth of both the cesium D1 and D2 resonance transitions are compared, and frequency stability measurements of the CSAC testbed are presented.
We report on the performance of the first table-top prototype atomic clock based on coherent population trapping (CPT) resonances with parallel linearly polarized optical fields (lin‖lin configuration). Our apparatus uses a vertical-cavity surface-emitting laser (VCSEL) tuned to the D1 line of 87Rb with the current modulation at the 87Rb hyperfine frequency. We demonstrate cancellation of the first-order light shift by the proper choice of rf modulation power and further improve our prototype clock stability by optimizing the parameters of the microwave lock loop. Operating in these optimal conditions, we measured a short-term fractional frequency stability (Allan deviation) 2×10−11τ−1/2 for observation times 1 s ≤ τ ≤ 20 s. This value is limited by large VCSEL phase noise and environmental temperature fluctuation. Further improvements in frequency stability should be possible with an apparatus designed as a dedicated lin‖lin CPT resonance clock with environmental impacts minimized.