Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE

VCSELs for atomic clocks

Darwin K. Serkland, Gregory M. Peake, K.M. Geib, Robert Lutwak, R. Michael Garvey, Mathew K. Varghese, Mark J. Mescher

Published Feb 9, 2006• 60 citations
Publisher

Abstract

The spectroscopic technique of coherent population trapping (CPT) enables an all-optical interrogation of the groundstate hyperfine splitting of cesium (or rubidium), compared to the optical-microwave double resonance technique conventionally employed in atomic frequency standards. All-optical interrogation enables the reduction of the size and power consumption of an atomic clock by two orders of magnitude, and vertical-cavity surface-emitting lasers (VCSELs) are preferred optical sources due to their low power consumption and circular output beam. Several research teams are currently using VCSELs for DARPA's chip-scale atomic clock (CSAC) program with the goal of producing an atomic clock having a volume < 1 cm^3, a power consumption < 30 mW, and an instability (Allan deviation) < 1x10^-11 during a 1-hour averaging interval. This paper describes the VCSEL requirements for CPT-based atomic clocks, which include single mode operation, single polarization operation, modulation bandwidth > 4 GHz, low power consumption (for the CSAC), narrow linewidth, and low relative intensity noise (RIN). A significant manufacturing challenge is to reproducibly obtain the required wavelength at the specified VCSEL operating temperature and drive current. Data are presented that show the advantage of operating at the D1 (rather than D2) resonance of the alkali atoms. Measurements of VCSEL linewidth will be discussed in particular, since atomic clock performance is especially sensitive to this parameter.

DOI
10.1117/12.647095

Related papers

The Chip-Scale Atomic Clock - Recent Development Progress

Robert Lutwak, Donald A. Emmons, Thomas C. English +1 more

We have undertaken the development of a chip-scale atomic clock (CSAC) whose design goals include short-term stability, sigma(sub y)(tau=1 hour), of 1x10(exp 11) with a total power consumption of 30 mW and an overall device volume of 1 cu cm. The stringent power requirement dominates the physics package architecture, dictating a small (<5 mm(exp 3) gaseous atomic ensemble interrogated by a low-power semiconductor laser. At PTTI 2002, we reported on initial experimental investigations leading to the decision to employ the coherent population trapping (CPT) interrogation technique. This paper describes our further progress on the CSAC effort, including the development of custom vertical cavity surface emitting laser (VCSEL) sources and techniques for microfabricating miniature cesium vapor cells comprised of anodically bonded silicon and glass. Measurements of the signal contrast and linewidth of both the cesium D1 and D2 resonance transitions are compared, and frequency stability measurements of the CSAC testbed are presented.

•Sep 1, 2004•55 citations

VCSELs for Atomic Sensors.

Darwin K. Serkland

A new generation of small low-power atomic sensors, including clocks, magnetometers, and gyroscopes, is being developed based on recently available MEMS and VCSEL technologies.These sensors rely on spectroscopic interrogation of alkali atoms, typically rubidium or cesium, contained in small vapor cells.The relevant spectroscopic wavelengths (in vacuum) are 894.6 nm (D1) and 852.3 nm (D2) for cesium, and 795.0 nm (D1) and 780.2 nm (D2) for rubidium.The D1 wavelengths are either preferred or required, depending on the application, and vertical-cavity surface-emitting lasers (VCSELs) are preferred optical sources because of their low power consumption and circular output beam.This paper describes the required VCSEL characteristics for atomic clocks and magnetometers.The fundamental VCSEL requirement is single-frequency output with tunability to the particular spectroscopic line of interest.Singlepolarization and single-transverse-mode operation are implicit requirements.VCSEL amplitude noise and frequency noise are also important because they contribute significantly to the sensor signal-to-noise ratio.Additional desired VCSEL attributes are low cost, low power consumption, and several years of continuous operating lifetime.This paper also describes the 894-nm VCSELs that we have developed for cesium-based atomic sensors.In particular, we discuss VCSEL noise measurements and accelerated lifetime testing.Finally, we report the performance of prototype atomic clocks employing VCSELs.

•Jul 26, 2016•0 citations

CPT chip-scale atomic clock with direct-modulation chip-external cavity diode laser

Jiqing Lian, Jie Miao, Tian Zhao +7 more

Chip-scale atomic clocks are critical for applications requiring compact, energy-efficient, and highly stable timing, such as GPS receivers and communication systems. Coherent population trapping (CPT)-based atomic clocks, which commonly use vertical-cavity surface-emitting lasers (VCSELs), have enabled significant miniaturization. However, their precision is limited by the broad linewidth of VCSELs. Alternative laser technologies, such as distributed Bragg reflector lasers, distributed feedback lasers, and external cavity diode lasers (ECDLs), offer potential improvements but face challenges in achieving compact size and adequate modulation bandwidth. This study presents a 795 nm chip-ECDL with a direct modulation bandwidth up to 4 GHz, specifically designed for CPT chip-scale atomic clocks. Based on the chip-ECDL, a CPT atomic clock with a compact volume of 19.4 ml and power consumption of 1.5 W has been developed. Under identical operating conditions, the CPT signal produced by the chip-ECDL exhibits a 34% reduction in linewidth and a 1.14-fold increase in contrast compared to a VCSEL-based clock. Demonstrating short-term stability better than 5×10−11τ−1/2(1 s<τ<2000 s) and reaching a best stability of 6.6×10−13 at 2000 s, this work represents the application of an ECDL in a CPT chip-scale clock, advancing the development of next-generation, high-performance chip-scale atomic clocks.

Applied Physics Letters•Jun 2, 2025•9 citations

External Cavity Laser for Chip-Scale Atomic Clock

Jie Miao, Jiqing Lian, Tianyu Liu +2 more

In this paper we report a new coherent population trapping (CPT) atomic clock based on external cavity laser. Unlike usual CPT atomic clocks, where used the vertical cavity surface emitting laser (VCSEL), we combine the external cavity laser (ECL) with CPT atomic clock to improve the stability. Compared with VCSEL, the ECL has higher laser power of 10 mW and narrower linewidth of 0.8 MHz, meaning that the signal-to-noise ratio of clock can be further improved.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 15, 2023•1 citation

Performance of a prototype atomic clock based on lin‖lin coherent population trapping resonances in Rb atomic vapor

Eugeniy E. Mikhailov, Travis Horrom, Nathan Belcher +1 more

We report on the performance of the first table-top prototype atomic clock based on coherent population trapping (CPT) resonances with parallel linearly polarized optical fields (lin‖lin configuration). Our apparatus uses a vertical-cavity surface-emitting laser (VCSEL) tuned to the D1 line of 87Rb with the current modulation at the 87Rb hyperfine frequency. We demonstrate cancellation of the first-order light shift by the proper choice of rf modulation power and further improve our prototype clock stability by optimizing the parameters of the microwave lock loop. Operating in these optimal conditions, we measured a short-term fractional frequency stability (Allan deviation) 2×10−11τ−1/2 for observation times 1 s ≤ τ ≤ 20 s. This value is limited by large VCSEL phase noise and environmental temperature fluctuation. Further improvements in frequency stability should be possible with an apparatus designed as a dedicated lin‖lin CPT resonance clock with environmental impacts minimized.

arXiv:0910.5881•Journal of the Optical Society of America B•Feb 3, 2010•53 citations

85Rb D1-Line Coherent-Population-Trapping Atomic Clock for Low-Power Operation

Shigeyoshi Goka

A 85Rb D1-line coherent-population-trapping (CPT) atomic clock with a natural-mixture Rb gas cell is demonstrated. D1-line excitation can generate a larger CPT resonance amplitude, and the choice of 85Rb rather than conventional 87Rb is because of its lower ground-state hyperfine-splitting frequency. The frequency deviation for the D1 line was measured using the same experimental setup as that for the D2 line except for the vertical-cavity surface-emitting laser (VCSEL) wavelength and RF power. In the case of D1-line excitation, the CPT resonance amplitude was 1.5 times that for the D2 line, and the light shift sensitivity was one-half that for the D2 line. The Allan standard deviations for the 85Rb D1 line, estimated from the frequency deviations, are <2.5×10-12 per day. In addition, the required RF is 1.5 GHz and its power is only -8.0 dBm.

Japanese Journal of Applied Physics•Jun 1, 2010•7 citations
The spectroscopic technique of coherent population trapping (CPT) enables an all-optical interrogation of the groundstate hyperfine splitting of cesium (or rubidium), compared to the optical-microwave double resonance technique conventionally employed in atomic frequency standards. All-optical interrogation enables the reduction of the size and power consumption of an atomic clock by two orders of magnitude, and vertical-cavity surface-emitting lasers (VCSELs) are preferred optical sources due to their low power consumption and circular output beam. Several research teams are currently using VCSELs for DARPA's chip-scale atomic clock (CSAC) program with the goal of producing an atomic clock having a volume < 1 cm^3, a power consumption < 30 mW, and an instability (Allan deviation) < 1x10^-11 during a 1-hour averaging interval. This paper describes the VCSEL requirements for CPT-based atomic clocks, which include single mode operation, single polarization operation, modulation bandwidth > 4 GHz, low power consumption (for the CSAC), narrow linewidth, and low relative intensity noise (RIN). A significant manufacturing challenge is to reproducibly obtain the required wavelength at the specified VCSEL operating temperature and drive current. Data are presented that show the advantage of operating at the D1 (rather than D2) resonance of the alkali atoms. Measurements of VCSEL linewidth will be discussed in particular, since atomic clock performance is especially sensitive to this parameter.
We have undertaken the development of a chip-scale atomic clock (CSAC) whose design goals include short-term stability, sigma(sub y)(tau=1 hour), of 1x10(exp 11) with a total power consumption of 30 mW and an overall device volume of 1 cu cm. The stringent power requirement dominates the physics package architecture, dictating a small (<5 mm(exp 3) gaseous atomic ensemble interrogated by a low-power semiconductor laser. At PTTI 2002, we reported on initial experimental investigations leading to the decision to employ the coherent population trapping (CPT) interrogation technique. This paper describes our further progress on the CSAC effort, including the development of custom vertical cavity surface emitting laser (VCSEL) sources and techniques for microfabricating miniature cesium vapor cells comprised of anodically bonded silicon and glass. Measurements of the signal contrast and linewidth of both the cesium D1 and D2 resonance transitions are compared, and frequency stability measurements of the CSAC testbed are presented.
A new generation of small low-power atomic sensors, including clocks, magnetometers, and gyroscopes, is being developed based on recently available MEMS and VCSEL technologies.These sensors rely on spectroscopic interrogation of alkali atoms, typically rubidium or cesium, contained in small vapor cells.The relevant spectroscopic wavelengths (in vacuum) are 894.6 nm (D1) and 852.3 nm (D2) for cesium, and 795.0 nm (D1) and 780.2 nm (D2) for rubidium.The D1 wavelengths are either preferred or required, depending on the application, and vertical-cavity surface-emitting lasers (VCSELs) are preferred optical sources because of their low power consumption and circular output beam.This paper describes the required VCSEL characteristics for atomic clocks and magnetometers.The fundamental VCSEL requirement is single-frequency output with tunability to the particular spectroscopic line of interest.Singlepolarization and single-transverse-mode operation are implicit requirements.VCSEL amplitude noise and frequency noise are also important because they contribute significantly to the sensor signal-to-noise ratio.Additional desired VCSEL attributes are low cost, low power consumption, and several years of continuous operating lifetime.This paper also describes the 894-nm VCSELs that we have developed for cesium-based atomic sensors.In particular, we discuss VCSEL noise measurements and accelerated lifetime testing.Finally, we report the performance of prototype atomic clocks employing VCSELs.
Chip-scale atomic clocks are critical for applications requiring compact, energy-efficient, and highly stable timing, such as GPS receivers and communication systems. Coherent population trapping (CPT)-based atomic clocks, which commonly use vertical-cavity surface-emitting lasers (VCSELs), have enabled significant miniaturization. However, their precision is limited by the broad linewidth of VCSELs. Alternative laser technologies, such as distributed Bragg reflector lasers, distributed feedback lasers, and external cavity diode lasers (ECDLs), offer potential improvements but face challenges in achieving compact size and adequate modulation bandwidth. This study presents a 795 nm chip-ECDL with a direct modulation bandwidth up to 4 GHz, specifically designed for CPT chip-scale atomic clocks. Based on the chip-ECDL, a CPT atomic clock with a compact volume of 19.4 ml and power consumption of 1.5 W has been developed. Under identical operating conditions, the CPT signal produced by the chip-ECDL exhibits a 34% reduction in linewidth and a 1.14-fold increase in contrast compared to a VCSEL-based clock. Demonstrating short-term stability better than 5×10−11τ−1/2(1 s<τ<2000 s) and reaching a best stability of 6.6×10−13 at 2000 s, this work represents the application of an ECDL in a CPT chip-scale clock, advancing the development of next-generation, high-performance chip-scale atomic clocks.
We report on the performance of the first table-top prototype atomic clock based on coherent population trapping (CPT) resonances with parallel linearly polarized optical fields (lin‖lin configuration). Our apparatus uses a vertical-cavity surface-emitting laser (VCSEL) tuned to the D1 line of 87Rb with the current modulation at the 87Rb hyperfine frequency. We demonstrate cancellation of the first-order light shift by the proper choice of rf modulation power and further improve our prototype clock stability by optimizing the parameters of the microwave lock loop. Operating in these optimal conditions, we measured a short-term fractional frequency stability (Allan deviation) 2×10−11τ−1/2 for observation times 1 s ≤ τ ≤ 20 s. This value is limited by large VCSEL phase noise and environmental temperature fluctuation. Further improvements in frequency stability should be possible with an apparatus designed as a dedicated lin‖lin CPT resonance clock with environmental impacts minimized.
A 85Rb D1-line coherent-population-trapping (CPT) atomic clock with a natural-mixture Rb gas cell is demonstrated. D1-line excitation can generate a larger CPT resonance amplitude, and the choice of 85Rb rather than conventional 87Rb is because of its lower ground-state hyperfine-splitting frequency. The frequency deviation for the D1 line was measured using the same experimental setup as that for the D2 line except for the vertical-cavity surface-emitting laser (VCSEL) wavelength and RF power. In the case of D1-line excitation, the CPT resonance amplitude was 1.5 times that for the D2 line, and the light shift sensitivity was one-half that for the D2 line. The Allan standard deviations for the 85Rb D1 line, estimated from the frequency deviations, are <2.5×10-12 per day. In addition, the required RF is 1.5 GHz and its power is only -8.0 dBm.