Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Continuously Excited Ramsey Simulation for High Sensitive Magnetometry

裕太 荒木, Yuta Araki, 伊久哉 藤崎, Ikuya Fujisaki, 則含 李, Zehan Li, 雄治 波多野, Yuji Hatano, 孝之 岩崎, Takayuki Iwasaki, 睦子 波多野, Mutsuko Hatano, M. Hatano

Published Nov 1, 2023• 0 citations
OpenAlex

Related papers

Implementation of Double Quantum Magnetometry to Continuously Excited Ramsey Method

裕太 荒木, Yuta Araki, 伊久哉 藤崎 +8 more

•Nov 1, 2022•0 citations

Sensitivity enhancement of a diamond quantum sensor with continuously excited Ramsey protocol

裕太 荒木, Yuta Araki, 伊久哉 藤崎 +10 more

•Feb 1, 2024•0 citations

High sensitivity magnetometry with Cs vapor

Rujie Li, Jiancheng Fang, Wei Quan

Bulletin of the American Physical Society•May 2, 2014•0 citations

Investigation on Sensitivity Parameters of Diamond Quantum Sensors Controlled by Continuously Excited Ramsey Protocol

則含 李, Zehan Li, 伊久哉 藤崎 +10 more

•Nov 1, 2023•0 citations

Watt-scale NV magnetometry with high sensitivity at sub-hertz frequencies

Jiahong Ying, Junjie Meng, Yunbin Zhu +2 more

Diamond and Related Materials•Jun 4, 2026•0 citations

Extension of Spin Dephasing Time of Continuously Excited Ensemble Nitrogen Vacancy Centers by Double‐Quantum Ramsey Magnetometry with Spin Bath Driving

Ikuya Fujisaki, Yuta Araki, Yuji Hatano +7 more

Quantum magnetic sensors based on nitrogen vacancy (NV) centers are expected to be used for various biological and medical applications. Continuously excited (CE) Ramsey magnetometry is one of the most sensitive measurement protocols and has the potential to improve the sensitivity of sensors using additional quantum manipulations to extend the spin dephasing time. In a typical ensemble NV measurement, the spin dephasing time is limited by inhomogeneous coupling. To overcome this limitation, a magnetometry that extends the CE Ramsey protocol with a double‐quantum (DQ) Ramsey sequence and spin bath driving is developed. It is demonstrated that the electric noise due to the spatial inhomogeneity of the crystal strain is cancelled out by the DQ Ramsey, and the magnetic noise due to the P1 centers was suppressed by spin bath driving. Compared to the conventional CE Ramsey, the CE‐DQ Ramsey with spin bath driving effectively doubles the gyromagnetic ratio and yields a twofold extension of , corresponding to a fourfold enhancement of the photon‐shot‐noise limited sensitivity.

physica status solidi (a)•Jul 3, 2023•3 citations
Quantum magnetic sensors based on nitrogen vacancy (NV) centers are expected to be used for various biological and medical applications. Continuously excited (CE) Ramsey magnetometry is one of the most sensitive measurement protocols and has the potential to improve the sensitivity of sensors using additional quantum manipulations to extend the spin dephasing time. In a typical ensemble NV measurement, the spin dephasing time is limited by inhomogeneous coupling. To overcome this limitation, a magnetometry that extends the CE Ramsey protocol with a double‐quantum (DQ) Ramsey sequence and spin bath driving is developed. It is demonstrated that the electric noise due to the spatial inhomogeneity of the crystal strain is cancelled out by the DQ Ramsey, and the magnetic noise due to the P1 centers was suppressed by spin bath driving. Compared to the conventional CE Ramsey, the CE‐DQ Ramsey with spin bath driving effectively doubles the gyromagnetic ratio and yields a twofold extension of , corresponding to a fourfold enhancement of the photon‐shot‐noise limited sensitivity.