Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

physica status solidi (a)

Extension of Spin Dephasing Time of Continuously Excited Ensemble Nitrogen Vacancy Centers by Double‐Quantum Ramsey Magnetometry with Spin Bath Driving

Ikuya Fujisaki, Yuta Araki, Yuji Hatano, T. Sekiguchi, Hiromitsu Kato, Shinobu Onoda, Takeshi Ohshima, Takayuki Shibata, Takayuki Iwasaki, Mutsuko Hatano

Published Jul 3, 2023• 3 citations
Publisher

Abstract

Quantum magnetic sensors based on nitrogen vacancy (NV) centers are expected to be used for various biological and medical applications. Continuously excited (CE) Ramsey magnetometry is one of the most sensitive measurement protocols and has the potential to improve the sensitivity of sensors using additional quantum manipulations to extend the spin dephasing time. In a typical ensemble NV measurement, the spin dephasing time is limited by inhomogeneous coupling. To overcome this limitation, a magnetometry that extends the CE Ramsey protocol with a double‐quantum (DQ) Ramsey sequence and spin bath driving is developed. It is demonstrated that the electric noise due to the spatial inhomogeneity of the crystal strain is cancelled out by the DQ Ramsey, and the magnetic noise due to the P1 centers was suppressed by spin bath driving. Compared to the conventional CE Ramsey, the CE‐DQ Ramsey with spin bath driving effectively doubles the gyromagnetic ratio and yields a twofold extension of , corresponding to a fourfold enhancement of the photon‐shot‐noise limited sensitivity.

DOI
10.1002/pssa.202300333

Related papers

Extension of Spin Dephasing Time of Millimeter Scale Ensemble NV centers by Suppressing Magnetic and Strain Field Inhomogeneities

Ikuya Fujisaki, Li Zehan, Yuji Hatano +11 more

Quantum magnetic sensors based on nitrogen-vacancy (NV) centers in diamond are expected to be applicable to biological and chemical applications However, their DC magnetic field sensitivity is still insufficient for demanding applications such as magnetoencephalography requiring extraordinary sensitivity. The spin dephasing time 𝑇2∗ is a key parameter to improve the sensitivity, but 𝑇2∗ of typical millimeter-scale NV centers is limited by magnetic field inhomogeneity, strain field inhomogeneity, and electronic spin bath. In this work, we developed (i) a magnet system suppressing both the longitudinal magnetic field and transverse strain field inhomogeneities and (ii) a microwave (MW) and radio-frequency (RF) application system for high-efficiency spin-bath driving (SBD) suitable for a diamond (111) sample.

•Oct 22, 2024•0 citations

Sensitive ac and dc magnetometry with nitrogen-vacancy-center ensembles in diamond

John F. Barry, Matthew Steinecker, Scott T. Alsid +4 more

Quantum sensing with solid-state spins offers the promise of high spatial resolution, bandwidth, and dynamic range at sensitivities comparable to more mature quantum sensing technologies, such as atomic vapor cells and superconducting devices. However, despite comparable theoretical sensitivity limits, the performance of bulk solid-state quantum sensors has so far lagged behind these more mature alternatives. A recent review [Barry et al., Rev. Mod. Phys. 92, 015004 (2020)] suggests several paths to improve performance of magnetometers employing nitrogen-vacancy defects in diamond, the most-studied solid-state quantum sensing platform. Implementing several suggested techniques, we demonstrate the most sensitive nitrogen-vacancy-based bulk magnetometer reported to date. Our approach combines tailored diamond growth to achieve low strain and long intrinsic dephasing times, the use of double-quantum Ramsey and Hahn-echo magnetometry sequences for broadband and narrowband magnetometry, respectively, and P1 driving to further extend dephasing time. Notably, the device does not include a flux concentrator, preserving the fixed response of the nitrogen vacancies to magnetic field. The magnetometer realizes a minimum sensitivity of $460\phantom{\rule{0.2em}{0ex}}\mathrm{fT}\phantom{\rule{0.2em}{0ex}}{\mathrm{s}}^{1/2}$ in a broadband dc-sensitive mode and $210\phantom{\rule{0.2em}{0ex}}\mathrm{fT}\phantom{\rule{0.2em}{0ex}}{\mathrm{s}}^{1/2}$ in a narrowband ac mode. We describe the experimental setup in detail and highlight potential paths for future improvement.

arXiv:2305.06269•Physical Review Applied•Oct 25, 2024•87 citations

Extension of Spin Dephasing Time of Continuously Excited Ensemble Nitrogen Vacancy Centers by Double-Quantum Ramsey Magnetometry with Spin Bath Driving

伊久哉 藤崎, Ikuya Fujisaki, 裕太 荒木 +11 more

•Jul 1, 2023•0 citations

Effects of optical excitation on the Ramsey magnetometry of ensemble NV centers in diamond

Y. Aoki, T. Sekiguchi, T. Shibata +10 more

Nitrogen-vacancy (NV) centers in diamond have found broad applications owing to optical spin initialization and readout as well as long spin coherence time at room temperature.1 Recently, we have reported the construction of a pulsed optically detected magnetic resonance (ODMR) system based on double quantum (DQ) Ramsey magnetometry with lock-in (LI) detection towards DC magnetic field sensitivity sufficient for magnetoencephalography.2 The LI detection of fluorescence allowed reduction of the noise floor, removal of the signal offset, and real-time monitoring of the magnetic field. Beyond the CW-ODMR, where spectral broadening and contrast reduction are induced by high-power excitation, the DQ-Ramsey is expected to have highersensitivity, as it allows extension of spin dephasing time T2 * and increase of contrast and fluorescence rates.2 In practice, however, the magnetic sensitivity depends also on how the optical excitation is applied. In this study, we report the excitation power stabilization by reducing the phase noise and the effect of the excitation power on the fluorescence saturation behavior.

•Nov 17, 2023•0 citations

Extending dephasing time of nitrogen-vacancy center in diamond by suppressing nuclear spin noise

Xinyu Chen, Chu-Dan Qiu, Ya-Nan Lu +4 more

Nitrogen-vacancy (NV) centers in diamond are a leading competitor for quantum sensing. The resolution of DC magnetic field sensing is limited by dephasing of the NV electron spin, with the main dephasing source being the thermal and quantum noise from the $^{13}\mathrm{C}$ nuclear spin bath. In this work, we propose an effective method to extend the dephasing time of a single NV electron spin by suppressing the nuclear spin noise. On the one hand, we improve the technique of bath driving to accommodate nuclear spin bath decoupling, and extend the dephasing time from 2.6 to 10.2 $\textmu{}\mathrm{s}$ at a magnetic field of 455 G. On the other hand, our method enables decoupling the quantum noise by inserting $\ensuremath{\pi}$ rotations around the $Z$ axis of the nuclear spin bath into the free evolution. By suppressing both the thermal and quantum noise, the dephasing time is extended by more than four times at 100 G. Our results provide a new route to explore strategies of suppressing the thermal noise and quantum noise in quantum information processing, and can be applied to other solid-state defects.

Physical review. B./Physical review. B•Nov 29, 2023•15 citations

Quantum diamond microscope for dynamic imaging of magnetic fields

Jiashen Tang, Zechuan Yin, Connor Hart +6 more

Wide-field imaging of magnetic signals using ensembles of nitrogen-vacancy (NV) centers in diamond has garnered increasing interest due to its combination of micron-scale resolution, millimeter-scale field of view, and compatibility with diverse samples from across the physical and life sciences. Recently, wide-field NV magnetic imaging based on the Ramsey protocol has achieved uniform and enhanced sensitivity compared to conventional measurements. Here, we integrate the Ramsey-based protocol with spin-bath driving to extend the NV spin dephasing time and improve magnetic sensitivity. We also employ a high-speed camera to enable dynamic wide-field magnetic imaging. We benchmark the utility of this quantum diamond microscope (QDM) by imaging magnetic fields produced from a fabricated wire phantom. Over a 270 × 270 μm2 field of view, a median per-pixel magnetic sensitivity of 4.1(1) nT /Hz is realized with a spatial resolution ≲ 10 μm and sub-millisecond temporal resolution. Importantly, the spatial magnetic noise floor can be reduced to the picotesla scale by time-averaging and signal modulation, which enables imaging of a magnetic-field pattern with a peak-to-peak amplitude difference of about 300 pT. Finally, we discuss potential new applications of this dynamic QDM in studying biomineralization and electrically active cells.

arXiv:2309.06587•AVS Quantum Science•Nov 17, 2023•15 citations
Quantum magnetic sensors based on nitrogen vacancy (NV) centers are expected to be used for various biological and medical applications. Continuously excited (CE) Ramsey magnetometry is one of the most sensitive measurement protocols and has the potential to improve the sensitivity of sensors using additional quantum manipulations to extend the spin dephasing time. In a typical ensemble NV measurement, the spin dephasing time is limited by inhomogeneous coupling. To overcome this limitation, a magnetometry that extends the CE Ramsey protocol with a double‐quantum (DQ) Ramsey sequence and spin bath driving is developed. It is demonstrated that the electric noise due to the spatial inhomogeneity of the crystal strain is cancelled out by the DQ Ramsey, and the magnetic noise due to the P1 centers was suppressed by spin bath driving. Compared to the conventional CE Ramsey, the CE‐DQ Ramsey with spin bath driving effectively doubles the gyromagnetic ratio and yields a twofold extension of , corresponding to a fourfold enhancement of the photon‐shot‐noise limited sensitivity.
Quantum magnetic sensors based on nitrogen-vacancy (NV) centers in diamond are expected to be applicable to biological and chemical applications However, their DC magnetic field sensitivity is still insufficient for demanding applications such as magnetoencephalography requiring extraordinary sensitivity. The spin dephasing time 𝑇2∗ is a key parameter to improve the sensitivity, but 𝑇2∗ of typical millimeter-scale NV centers is limited by magnetic field inhomogeneity, strain field inhomogeneity, and electronic spin bath. In this work, we developed (i) a magnet system suppressing both the longitudinal magnetic field and transverse strain field inhomogeneities and (ii) a microwave (MW) and radio-frequency (RF) application system for high-efficiency spin-bath driving (SBD) suitable for a diamond (111) sample.
Quantum sensing with solid-state spins offers the promise of high spatial resolution, bandwidth, and dynamic range at sensitivities comparable to more mature quantum sensing technologies, such as atomic vapor cells and superconducting devices. However, despite comparable theoretical sensitivity limits, the performance of bulk solid-state quantum sensors has so far lagged behind these more mature alternatives. A recent review [Barry et al., Rev. Mod. Phys. 92, 015004 (2020)] suggests several paths to improve performance of magnetometers employing nitrogen-vacancy defects in diamond, the most-studied solid-state quantum sensing platform. Implementing several suggested techniques, we demonstrate the most sensitive nitrogen-vacancy-based bulk magnetometer reported to date. Our approach combines tailored diamond growth to achieve low strain and long intrinsic dephasing times, the use of double-quantum Ramsey and Hahn-echo magnetometry sequences for broadband and narrowband magnetometry, respectively, and P1 driving to further extend dephasing time. Notably, the device does not include a flux concentrator, preserving the fixed response of the nitrogen vacancies to magnetic field. The magnetometer realizes a minimum sensitivity of 460fTs1/2460\phantom{\rule{0.2em}{0ex}}\mathrm{fT}\phantom{\rule{0.2em}{0ex}}{\mathrm{s}}^{1/2}460fTs1/2 in a broadband dc-sensitive mode and 210fTs1/2210\phantom{\rule{0.2em}{0ex}}\mathrm{fT}\phantom{\rule{0.2em}{0ex}}{\mathrm{s}}^{1/2}210fTs1/2 in a narrowband ac mode. We describe the experimental setup in detail and highlight potential paths for future improvement.
Nitrogen-vacancy (NV) centers in diamond have found broad applications owing to optical spin initialization and readout as well as long spin coherence time at room temperature.1 Recently, we have reported the construction of a pulsed optically detected magnetic resonance (ODMR) system based on double quantum (DQ) Ramsey magnetometry with lock-in (LI) detection towards DC magnetic field sensitivity sufficient for magnetoencephalography.2 The LI detection of fluorescence allowed reduction of the noise floor, removal of the signal offset, and real-time monitoring of the magnetic field. Beyond the CW-ODMR, where spectral broadening and contrast reduction are induced by high-power excitation, the DQ-Ramsey is expected to have highersensitivity, as it allows extension of spin dephasing time T2 * and increase of contrast and fluorescence rates.2 In practice, however, the magnetic sensitivity depends also on how the optical excitation is applied. In this study, we report the excitation power stabilization by reducing the phase noise and the effect of the excitation power on the fluorescence saturation behavior.
Nitrogen-vacancy (NV) centers in diamond are a leading competitor for quantum sensing. The resolution of DC magnetic field sensing is limited by dephasing of the NV electron spin, with the main dephasing source being the thermal and quantum noise from the 13C^{13}\mathrm{C}13C nuclear spin bath. In this work, we propose an effective method to extend the dephasing time of a single NV electron spin by suppressing the nuclear spin noise. On the one hand, we improve the technique of bath driving to accommodate nuclear spin bath decoupling, and extend the dephasing time from 2.6 to 10.2 $\textmu{}\mathrm{s}$ at a magnetic field of 455 G. On the other hand, our method enables decoupling the quantum noise by inserting $\ensuremath{\pi}$ rotations around the ZZZ axis of the nuclear spin bath into the free evolution. By suppressing both the thermal and quantum noise, the dephasing time is extended by more than four times at 100 G. Our results provide a new route to explore strategies of suppressing the thermal noise and quantum noise in quantum information processing, and can be applied to other solid-state defects.
Wide-field imaging of magnetic signals using ensembles of nitrogen-vacancy (NV) centers in diamond has garnered increasing interest due to its combination of micron-scale resolution, millimeter-scale field of view, and compatibility with diverse samples from across the physical and life sciences. Recently, wide-field NV magnetic imaging based on the Ramsey protocol has achieved uniform and enhanced sensitivity compared to conventional measurements. Here, we integrate the Ramsey-based protocol with spin-bath driving to extend the NV spin dephasing time and improve magnetic sensitivity. We also employ a high-speed camera to enable dynamic wide-field magnetic imaging. We benchmark the utility of this quantum diamond microscope (QDM) by imaging magnetic fields produced from a fabricated wire phantom. Over a 270 × 270 μm2 field of view, a median per-pixel magnetic sensitivity of 4.1(1) nT /Hz is realized with a spatial resolution ≲ 10 μm and sub-millisecond temporal resolution. Importantly, the spatial magnetic noise floor can be reduced to the picotesla scale by time-averaging and signal modulation, which enables imaging of a magnetic-field pattern with a peak-to-peak amplitude difference of about 300 pT. Finally, we discuss potential new applications of this dynamic QDM in studying biomineralization and electrically active cells.