International Conference on Optical Fiber Sensors (OFS)
Improved Closed-Loop Slow-Light Temperature Sensor With Millidegree Resolution for Laser Cooling
Enkeleda Balliu, Lauris Talbot, Chun‐Wei Chen, Benjamin N. Frey, Bailey Meehan, Thomas Wade Hawkins, John M. Ballato, Tommy Boilard, Martin Bernier, Michel J. F. Digonnet
Abstract
For applications such as laser cooling of doped fibers, where it is critical to measure accurately the temperature of a cooled fiber that is very close to room temperature, it is paramount to develop a reliable, very short (mm) fiber temperature sensor with millikelvin resolution and very little drift. We report a second generation of a unique slow-light fiber Bragg grating (FBG) temperature sensor that meets these stringent requirements. Experiments and modeling establish that its temperature response depends only on well-known material constants of the silica FBG and the response of the probe laser’s wavelength controller. The response is independent of the linewidth of the slow-light resonance, hence different FBGs and/or resonances have the exact same response. Examples of measured cooling in optically pumped Yb-doped fibers show that more reliable thermal contact with the cooled fiber is obtained by wrapping the FBG and the cooled fiber.