Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Express

High precision microwave measurement based on nitrogen-vacancy color center and application in velocity detection

Hao Zhang, Zhonghao Li, Chenyu Yang, Zongmin Ma, Hao Guo, Huanfei Wen, Xin Li, Jun Tang, Jun Liu

Published Jan 23, 2024• 9 citations
Publisher

Abstract

Wide-range high-precision velocity detection with nitrogen-vacancy (NV) color center has been realized. By treating the NV color center as a mixer, the high-precision microwave measurement is realized. Through optimization of acquisition time, the microwave frequency resolution is improved to the mHz level. Combined with the frequency-velocity conversion model, velocity detection is realized in the range of 0-100 cm/s, and the velocity resolution is up to 0.012 cm/s. The maximum deviation in repeated measurements does not exceed 1/1000. Finally, combined with the multiplexed microwave reference technique, the range of velocity can be extended to 7.4 × 10 5 m/s. All of the results provide reference for high-precision velocity detection and play a significant role in various domains of quantum precision measurement. This study provides a crucial technical foundation for the development of high-dynamic-range velocity detectors and novel quantum precision velocity measurement technologies.

DOI
10.1364/oe.511056

Related papers

High-frequency resolution diamond nitrogen-vacancy center wide-spectrum imaging technology

Yuanyuan Shen, Bo Wang, Dongqian Ke +10 more

High-resolution wide-spectrum measurement techniques have important applications in fields such as astronomy, wireless communication, and medical imaging. Nitrogen-vacancy (NV) center in diamond is well known for its high stability, high sensitivity, real-time monitoring, single-point detection, and suitability for long-term measurement, and has an outstanding choice for spectrum analyzers. Currently, spectrum analyzers based on NV centers as detectors can perform real-time spectrum analysis in the range of several tens of gigahertz, but their frequency resolution is limited to a MHz level. In this study, we construct a quantum diamond microwave spectrum imaging system by combining continuous wave-mixing techniques. According to the spin-related properties of the NV center in diamond, we implement optical pumping by 532 nm green laser light illuminating the diamond NV center. A spherical magnet is used to produce a magnetic field gradient along the direction of the diamond crystal. By adjusting the size and direction of the magnetic field gradient, spatial encoding of the resonance frequency of the NV center is achieved. The magnetic field gradient induces the Zeeman effect on the diamond surface at different positions, generating corresponding ODMR signals. Through accurate programming, we coordinate the frequency scanning step size of the microwave source with the camera exposure and image storage time, and synchronize them circularly according to the order of image acquisition. Ultimately, after algorithmic processing, we successfully obtain comprehensive spectrum data in a range from 900 MHz to 6.0 GHz. Within the measurable spectrum range, the system employs continuous wave-mixing, simultaneously applying resonant microwaves and slightly detuning auxiliary microwaves to effectively excite the NV center. This method triggers off microwave interference effects, disrupting the balance between laser-induced polarization and microwave-induced spontaneous relaxation. Specifically, microwave interference causes the phase and amplitude of the fluorescence signal to change, leading to the generation of alternating current fluorescence signals. This further enhances the response of the NV magnetometer to weak microwave signals. The method enables the system to achieve a frequency resolution of 1 Hz in the measurable spectrum range, and it can separately measure the frequency resolution of multiple frequency points with a frequency step size of 1 MHz. The research results indicate that the wide-spectrum measurement based on NV centers can achieve sub-hertz frequency resolution, providing robust technical support for future spectrum analysis and applications.

Acta Physica Sinica•Jan 1, 2024•0 citations

Simultaneously Detecting the Power and Temperature of a Microwave Sensor via the Quantum Technique

Zhenrong Zhang, Y. W. Jin, Jun Tang +1 more

This study introduces a novel method for the simultaneous detection of microwave sensor power and temperature, leveraging nitrogen-vacancy (NV) centers as a robust quantum system. Through precise measurement of the optical detection magnetic resonance contrast in NV centers, the microwave power is accurately determined. Furthermore, the temperature of the sensor is obtained by monitoring the variations in zero-field splitting and thorough spectral analysis. This method enables the efficient real-time acquisition of synchronized data on both microwave power and temperature from the sensor, facilitating concurrent monitoring without the necessity of additional sensing devices. Finally, we verified that the magnetic sensitivity of the system is approximately 1.2 nT/Hz1/2, and the temperature sensitivity is around 0.38 mK/Hz1/2. The minimum resolution of microwave power is about 20 nW. The experimental results demonstrate that this quantum measurement technique provides stable and accurate data across a wide range of microwave power and temperature conditions. These findings indicate substantial potential for this technique in advanced applications such as aerospace, medical diagnostics, and high-frequency communications. Future studies will aim to extend the industrial applicability of this method by refining quantum control techniques within NV center systems.

Micromachines•Oct 28, 2024•1 citation

Spatial Microwave Field Frequency Measurement through Two‐Level Resonance of Nitrogen‐Vacancy Color Center in Diamond

Yanjie Gao, Yusong Liu, Hao Guo +5 more

This article presents a frequency measurement method for spatial microwave signals with solid‐state atom resonance, performing measurements based on the burnt hole in spectrum with two microwave fields acting on nitrogen vacancies (NVs) simultaneously. The population on |0⟩ of the NV color center in the ground state affected by the resonance of two microwave fields with similar frequencies responds excellently to external microwave frequencies, and a phenomenon named hole burning occurs. The full width at half maximum (FWHM) of the resonant peak at the hole is 18.9 kHz. When microwaves of different frequencies are applied, the resonant peak precisely follows the signal frequency in the experiment. Subsequently, the resonant peak is processed using the differential method to obtain a frequency measurement error on the order of 100 Hz. The spatial resolution of this method is within the millimeter scale. This study can provide technical support for applications in microwave frequency measurement and spatial mapping with quantum precision measurement.

physica status solidi (b)•Sep 17, 2023•0 citations

Simultaneous Identification of Multiple Microwave Signals in 313-MHz Continuous Bandwidth Using Nitrogen-Vacancy Centers in Diamond

Y. W. Jin, Huan Fei Wen, Ding Wang +8 more

The efficient and reliable detection of microwave signals is a key element of the breakthrough in new-generation communication technology. In this article, we proposed an approach for the simultaneous identification of multiple microwave signals in a continuous frequency range based on the spectral hole-burning effect of nitrogen-vacancy (NV) centers. The protocol combines the quantum wide-field imaging method with magnetic gradient means, breaking the narrowband and discrete detection limitations of conventional optically detected magnetic resonance (ODMR) techniques. The frequencies of multiple microwave signals can be accurately decoupled by locating the relevant gaps on resonance frequency curves. Meanwhile, the effects induced by fixed-frequency signals with different powers on the resonance frequency curves were systematically analyzed. The experimental results indicated that the system realized a multiple-frequency resolution of 1 MHz and a minimum detectable power of 1 mW over a continuous bandwidth of 313-MHz. This proposal is capable of real-time and simultaneous detection of multiple microwave signals, which remarkably improves the utilization efficiency of spectrum resources.

IEEE Transactions on Microwave Theory and Techniques•Jul 30, 2024•0 citations

Simultaneous Determination of Multiple Microwave Signals With High-Frequency Resolution Using Quantum Sensing Technique

Rui Zhao, Ding Wang, Huan Fei Wen +4 more

This article presents a method to simultaneously determine multiple microwave signals using the hole-burning effect based on nitrogen-vacancy (NV) centers in diamonds. Tracking the anomalous peaks caused by fixed-frequency microwave signals in the optically detected magnetic resonance spectrum, the frequencies under test can be detected with high precision and accuracy in real time. Meanwhile, the applicability of the scheme in detecting microwave signals of different power is evaluated systematically by adjusting the power of measured fixed-frequency microwave signals. In addition, the frequency resolution of the system is characterized by modulating the frequency of one of the microwave signals. The experiment results indicate that the frequency resolution is as small as 5 kHz and the recognition deviation is less than 0.40 kHz. The method will provide a new idea in the field of electromagnetic compatibility testing, radio signal processing, and Internet of Things Engineering.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2024•2 citations

Wideband microwave resonator for NV center vector magnetometry

S. V. Bolshedvorskii, E. A. Koreshin, V. V. Soshenko +10 more

The nitrogen-vacancy (NV) color center in diamond has found applications in magnetometry across various geometrical scales. In particular, vector magnetometry using hand-held devices with low power consumption is of interest for mobile and geological applications. However, such a device requires efficient driving of the four different orientations of the NV center, thus placing demands on a broadband microwave resonator that provides a uniform and highly insensitive microwave magnetic field at the resonance frequencies of the NV centers. Here, we propose a unique planar resonator design that enables efficient driving of all four orientations of NV color centers over a 100 MHz range with only 0.5 W of microwave input power and 250 mW of laser power, allowing vector magnetic field measurements. Using the planar resonator to drive NV centers in diamond, a compact vector magnetometer was fabricated and experimentally studied. The sensitivity of the device is about \[{1.2\text{ nT}}/{\sqrt{\text{Hz}}}\;\]. While this is not a record sensitivity for diamond-based magnetometers, this device occupies its own niche as a compact hand-held magnetometer.

quant-pharXiv:2610.13379•Oct 12, 2026
Wide-range high-precision velocity detection with nitrogen-vacancy (NV) color center has been realized. By treating the NV color center as a mixer, the high-precision microwave measurement is realized. Through optimization of acquisition time, the microwave frequency resolution is improved to the mHz level. Combined with the frequency-velocity conversion model, velocity detection is realized in the range of 0-100 cm/s, and the velocity resolution is up to 0.012 cm/s. The maximum deviation in repeated measurements does not exceed 1/1000. Finally, combined with the multiplexed microwave reference technique, the range of velocity can be extended to 7.4 × 10 5 m/s. All of the results provide reference for high-precision velocity detection and play a significant role in various domains of quantum precision measurement. This study provides a crucial technical foundation for the development of high-dynamic-range velocity detectors and novel quantum precision velocity measurement technologies.
High-resolution wide-spectrum measurement techniques have important applications in fields such as astronomy, wireless communication, and medical imaging. Nitrogen-vacancy (NV) center in diamond is well known for its high stability, high sensitivity, real-time monitoring, single-point detection, and suitability for long-term measurement, and has an outstanding choice for spectrum analyzers. Currently, spectrum analyzers based on NV centers as detectors can perform real-time spectrum analysis in the range of several tens of gigahertz, but their frequency resolution is limited to a MHz level. In this study, we construct a quantum diamond microwave spectrum imaging system by combining continuous wave-mixing techniques. According to the spin-related properties of the NV center in diamond, we implement optical pumping by 532 nm green laser light illuminating the diamond NV center. A spherical magnet is used to produce a magnetic field gradient along the direction of the diamond crystal. By adjusting the size and direction of the magnetic field gradient, spatial encoding of the resonance frequency of the NV center is achieved. The magnetic field gradient induces the Zeeman effect on the diamond surface at different positions, generating corresponding ODMR signals. Through accurate programming, we coordinate the frequency scanning step size of the microwave source with the camera exposure and image storage time, and synchronize them circularly according to the order of image acquisition. Ultimately, after algorithmic processing, we successfully obtain comprehensive spectrum data in a range from 900 MHz to 6.0 GHz. Within the measurable spectrum range, the system employs continuous wave-mixing, simultaneously applying resonant microwaves and slightly detuning auxiliary microwaves to effectively excite the NV center. This method triggers off microwave interference effects, disrupting the balance between laser-induced polarization and microwave-induced spontaneous relaxation. Specifically, microwave interference causes the phase and amplitude of the fluorescence signal to change, leading to the generation of alternating current fluorescence signals. This further enhances the response of the NV magnetometer to weak microwave signals. The method enables the system to achieve a frequency resolution of 1 Hz in the measurable spectrum range, and it can separately measure the frequency resolution of multiple frequency points with a frequency step size of 1 MHz. The research results indicate that the wide-spectrum measurement based on NV centers can achieve sub-hertz frequency resolution, providing robust technical support for future spectrum analysis and applications.
This study introduces a novel method for the simultaneous detection of microwave sensor power and temperature, leveraging nitrogen-vacancy (NV) centers as a robust quantum system. Through precise measurement of the optical detection magnetic resonance contrast in NV centers, the microwave power is accurately determined. Furthermore, the temperature of the sensor is obtained by monitoring the variations in zero-field splitting and thorough spectral analysis. This method enables the efficient real-time acquisition of synchronized data on both microwave power and temperature from the sensor, facilitating concurrent monitoring without the necessity of additional sensing devices. Finally, we verified that the magnetic sensitivity of the system is approximately 1.2 nT/Hz1/2, and the temperature sensitivity is around 0.38 mK/Hz1/2. The minimum resolution of microwave power is about 20 nW. The experimental results demonstrate that this quantum measurement technique provides stable and accurate data across a wide range of microwave power and temperature conditions. These findings indicate substantial potential for this technique in advanced applications such as aerospace, medical diagnostics, and high-frequency communications. Future studies will aim to extend the industrial applicability of this method by refining quantum control techniques within NV center systems.
This article presents a frequency measurement method for spatial microwave signals with solid‐state atom resonance, performing measurements based on the burnt hole in spectrum with two microwave fields acting on nitrogen vacancies (NVs) simultaneously. The population on |0⟩ of the NV color center in the ground state affected by the resonance of two microwave fields with similar frequencies responds excellently to external microwave frequencies, and a phenomenon named hole burning occurs. The full width at half maximum (FWHM) of the resonant peak at the hole is 18.9 kHz. When microwaves of different frequencies are applied, the resonant peak precisely follows the signal frequency in the experiment. Subsequently, the resonant peak is processed using the differential method to obtain a frequency measurement error on the order of 100 Hz. The spatial resolution of this method is within the millimeter scale. This study can provide technical support for applications in microwave frequency measurement and spatial mapping with quantum precision measurement.
The efficient and reliable detection of microwave signals is a key element of the breakthrough in new-generation communication technology. In this article, we proposed an approach for the simultaneous identification of multiple microwave signals in a continuous frequency range based on the spectral hole-burning effect of nitrogen-vacancy (NV) centers. The protocol combines the quantum wide-field imaging method with magnetic gradient means, breaking the narrowband and discrete detection limitations of conventional optically detected magnetic resonance (ODMR) techniques. The frequencies of multiple microwave signals can be accurately decoupled by locating the relevant gaps on resonance frequency curves. Meanwhile, the effects induced by fixed-frequency signals with different powers on the resonance frequency curves were systematically analyzed. The experimental results indicated that the system realized a multiple-frequency resolution of 1 MHz and a minimum detectable power of 1 mW over a continuous bandwidth of 313-MHz. This proposal is capable of real-time and simultaneous detection of multiple microwave signals, which remarkably improves the utilization efficiency of spectrum resources.
This article presents a method to simultaneously determine multiple microwave signals using the hole-burning effect based on nitrogen-vacancy (NV) centers in diamonds. Tracking the anomalous peaks caused by fixed-frequency microwave signals in the optically detected magnetic resonance spectrum, the frequencies under test can be detected with high precision and accuracy in real time. Meanwhile, the applicability of the scheme in detecting microwave signals of different power is evaluated systematically by adjusting the power of measured fixed-frequency microwave signals. In addition, the frequency resolution of the system is characterized by modulating the frequency of one of the microwave signals. The experiment results indicate that the frequency resolution is as small as 5 kHz and the recognition deviation is less than 0.40 kHz. The method will provide a new idea in the field of electromagnetic compatibility testing, radio signal processing, and Internet of Things Engineering.
The nitrogen-vacancy (NV) color center in diamond has found applications in magnetometry across various geometrical scales. In particular, vector magnetometry using hand-held devices with low power consumption is of interest for mobile and geological applications. However, such a device requires efficient driving of the four different orientations of the NV center, thus placing demands on a broadband microwave resonator that provides a uniform and highly insensitive microwave magnetic field at the resonance frequencies of the NV centers. Here, we propose a unique planar resonator design that enables efficient driving of all four orientations of NV color centers over a 100 MHz range with only 0.5 W of microwave input power and 250 mW of laser power, allowing vector magnetic field measurements. Using the planar resonator to drive NV centers in diamond, a compact vector magnetometer was fabricated and experimentally studied. The sensitivity of the device is about 1.2 nT/Hz  {1.2\text{ nT}}/{\sqrt{\text{Hz}}}\;1.2 nT/Hz​. While this is not a record sensitivity for diamond-based magnetometers, this device occupies its own niche as a compact hand-held magnetometer.