Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEEE Transactions on Antennas and Propagation

Microwave Angle-of-Arrival Detection using Nitrogen-Vacancy Center Receiver

Hao Zhang, Zhonghao Li, Bokun Duan, Xu Liu, Zongmin Ma, Jun Tang, Jun Liu, Liantuan Xiao

Published Jan 1, 2026• 0 citations
Publisher

Abstract

Angle of Arrival (AoA) detection plays a pivotal role in wireless communication, target localization, and remote sensing navigation, demonstrating significant importance and extensive application potential. This study introduces a microwave AoA measurement method based on a solid-state quantum spin nitrogen-vacancy (NV) center receiver, which has tunable microwave frequency response. By integrating microwave heterodyne detection with an electron spin model, the proposed approach achieves high-precision microwave phase measurement. Exploiting the functional relationship between phase and incident angle, accurate AoA sensing is realized. Furthermore, leveraging the magnetic field-tuned resonance characteristics of NV centers, a microwave AoA measurement system capable of accommo-dating diverse detection frequency bands is constructed. Experimental validation at multiple operating frequencies confirms the system’s frequency reconfigurability, stability, and reliability. Results indicate that within the tested range of 40° to 140°, the AoA measurements exhibit the smallest deviation of 0.62° at an incident angle of 90°, while the largest deviation of 4.58° is observed at an incident angle of 140°. Long-term heterodyne measurements further verify the phase stability of the proposed detection scheme. These findings provide crucial experimental evidence for the application of quantum technology in electromagnetic target identification, navigation, and localization, while laying a robust foundation for the development of miniaturized and integrated AoA quantum measurement systems.

DOI
10.1109/tap.2026.3739616

Related papers

Measurement of Doppler Frequency Shift and Angle of Arrival With Rydberg Atom-Based Sensors

Shaochen Yan, LI Xin-yao, Xiaoyan Pang +5 more

Doppler frequency shift (DFS) and angle of arrival (AOA) measurements play a crucial role in modern radar, aviation, and satellite communication systems. Rydberg atom-based receivers are renowned for the high sensitivity, wide operating frequency range, and immunity to electromagnetic interference in microwave electric field sensing. In this work, the concept of electromagnetically induced transparency (EIT) with Rydberg atoms, along with heterodyne mixing techniques, is employed to accurately measure both the DFS and AOA of microwave field within a unified experimental system. The proposed scheme utilizes the dual-coupled beams in the Rydberg atom vapor cell to reduce experimental errors and improve the measurement accuracy. The experimental results indicate that within the frequency measurement range from 11 to 18 GHz, the experimental error in measuring the DFS of different Rydberg states is within ±0.5 Hz, showcasing the wideband tunability of the system. Moreover, the AOA measurement for the echo signal reveal that the measurement error is less than 0.5° within the range from –30° to 35°. This research shows the first instance of simultaneously measuring DFS and AOA within the same Rydberg atom system. Additionally, by introducing the concept of ’relative frequency zero point’ in DFS measurement for the first time, the differentiation of the direction of the DFS can be identified. Furthermore, the accuracy of AOA measurement based on Rydberg atoms has been further improved in this research. Overall, this research provides a novel approach for measuring DFS and AOA using Rydberg atomic system.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2025•13 citations

High precision microwave measurement based on nitrogen-vacancy color center and application in velocity detection

Hao Zhang, Zhonghao Li, Chenyu Yang +6 more

Wide-range high-precision velocity detection with nitrogen-vacancy (NV) color center has been realized. By treating the NV color center as a mixer, the high-precision microwave measurement is realized. Through optimization of acquisition time, the microwave frequency resolution is improved to the mHz level. Combined with the frequency-velocity conversion model, velocity detection is realized in the range of 0-100 cm/s, and the velocity resolution is up to 0.012 cm/s. The maximum deviation in repeated measurements does not exceed 1/1000. Finally, combined with the multiplexed microwave reference technique, the range of velocity can be extended to 7.4 × 10 5 m/s. All of the results provide reference for high-precision velocity detection and play a significant role in various domains of quantum precision measurement. This study provides a crucial technical foundation for the development of high-dynamic-range velocity detectors and novel quantum precision velocity measurement technologies.

Optics Express•Jan 23, 2024•9 citations

A novel demodulation method for transmission using nitrogen–vacancy-based solid-state quantum sensor

Ruixin Bai, Xinyue Zhu, Fan Yang +6 more

Diamond based quantum sensing is a fast-emerging field with both scientific and technological significance. The nitrogen–vacancy (NV) center, a crystal defect in diamond, has become a unique object for microwave sensing applications due to its excellent stability, long spin coherence time, and optical properties at ambient condition. In this work, we use diamond NV center as atomic receiver to demodulate on–off keying (OOK) signal transmitted in broad frequency range (2 GHz–14 GHz in a portable benchtop setup). We proposed a unique algorithm of voltage discrimination and demonstrated audio signal transceiving with fidelity above 99%. This diamond receiver is attached to the end of a tapered fiber, having all optic nature, which will find important applications in data transmission tasks under extreme conditions such as strong electromagnetic interference, high temperatures, and high corrosion.

Chinese Physics B•Feb 17, 2022•7 citations

Solid-State Quantum Microwave Standard Using Nitrogen-Vacancy Centers in Diamond

Masahiro Yamamoto, Moriyoshi Haruyama, Moto Kinoshita +3 more

Solid-state quantum sensors based on nitrogen-vacancy (NV) centers in diamond offer room-temperature operation, chemical stability, and a wide range of operating environments, and their application to microwave (MW) measurements are anticipated. In this study, we propose a method for quantitative MW field measurements under continuous-wave driving, referred to as the "NV Candle," aimed at realizing a solid-state quantum MW standard. Building on the atomic candle concept developed in atomic vapor systems, this method employs phase modulation of MW and resonance with Rabi oscillations to extract the Rabi frequency in the frequency domain. Experiments using NV centers in diamond demonstrated that the MW magnetic field derived from the NV Candle signals exhibited linearity over a 20 dB dynamic range. This work presents a novel approach to realize a solid-state quantum MW standard with enhanced robustness and practical applicability.

Conference on Precision Electromagnetic Measurements•Sep 1, 2026•0 citations

Rydberg-Atom-Based Angle-of-Arrival Estimation Method for Ku-Band Microwave Signals

Xingchen Hu, Hao Wu, Yong Gao +3 more

The determination of the angle of arrival (AoA) of Ku-band microwave signals is of great significance in satellite communications, spectrum monitoring, and national defense security, which has created an urgent demand for high-precision and interference-resistant passive detection techniques. In this study, we propose a Rydberg-atom-based passive measurement method for estimating the AoA of Ku-band incident signals. Based on well-established quantum optical techniques, the proposed method converts the EIT-AT splitting intervals induced by waves or signals incident from different directions in Rydberg atoms within a single vapor cell into the electric-field intensity at the atomic sensor. An electric-field-intensity-angle response model is then established for AoA estimation of a 13.6 GHz wave or signal. Simulation results demonstrate that the proposed method can determine the incident direction within a certain angular range, with an estimation error of less than 3.8°. Without the need for self-calibration and free from interference caused by actively emitted probing electromagnetic waves or reference electric fields, the proposed approach enables AoA determination of incident waves or signals using a single vapor cell with a length of 5 cm.

Sensors•Aug 11, 2026•1 citation

Simultaneously Detecting the Power and Temperature of a Microwave Sensor via the Quantum Technique

Zhenrong Zhang, Y. W. Jin, Jun Tang +1 more

This study introduces a novel method for the simultaneous detection of microwave sensor power and temperature, leveraging nitrogen-vacancy (NV) centers as a robust quantum system. Through precise measurement of the optical detection magnetic resonance contrast in NV centers, the microwave power is accurately determined. Furthermore, the temperature of the sensor is obtained by monitoring the variations in zero-field splitting and thorough spectral analysis. This method enables the efficient real-time acquisition of synchronized data on both microwave power and temperature from the sensor, facilitating concurrent monitoring without the necessity of additional sensing devices. Finally, we verified that the magnetic sensitivity of the system is approximately 1.2 nT/Hz1/2, and the temperature sensitivity is around 0.38 mK/Hz1/2. The minimum resolution of microwave power is about 20 nW. The experimental results demonstrate that this quantum measurement technique provides stable and accurate data across a wide range of microwave power and temperature conditions. These findings indicate substantial potential for this technique in advanced applications such as aerospace, medical diagnostics, and high-frequency communications. Future studies will aim to extend the industrial applicability of this method by refining quantum control techniques within NV center systems.

Micromachines•Oct 28, 2024•1 citation
Angle of Arrival (AoA) detection plays a pivotal role in wireless communication, target localization, and remote sensing navigation, demonstrating significant importance and extensive application potential. This study introduces a microwave AoA measurement method based on a solid-state quantum spin nitrogen-vacancy (NV) center receiver, which has tunable microwave frequency response. By integrating microwave heterodyne detection with an electron spin model, the proposed approach achieves high-precision microwave phase measurement. Exploiting the functional relationship between phase and incident angle, accurate AoA sensing is realized. Furthermore, leveraging the magnetic field-tuned resonance characteristics of NV centers, a microwave AoA measurement system capable of accommo-dating diverse detection frequency bands is constructed. Experimental validation at multiple operating frequencies confirms the system’s frequency reconfigurability, stability, and reliability. Results indicate that within the tested range of 40° to 140°, the AoA measurements exhibit the smallest deviation of 0.62° at an incident angle of 90°, while the largest deviation of 4.58° is observed at an incident angle of 140°. Long-term heterodyne measurements further verify the phase stability of the proposed detection scheme. These findings provide crucial experimental evidence for the application of quantum technology in electromagnetic target identification, navigation, and localization, while laying a robust foundation for the development of miniaturized and integrated AoA quantum measurement systems.
Doppler frequency shift (DFS) and angle of arrival (AOA) measurements play a crucial role in modern radar, aviation, and satellite communication systems. Rydberg atom-based receivers are renowned for the high sensitivity, wide operating frequency range, and immunity to electromagnetic interference in microwave electric field sensing. In this work, the concept of electromagnetically induced transparency (EIT) with Rydberg atoms, along with heterodyne mixing techniques, is employed to accurately measure both the DFS and AOA of microwave field within a unified experimental system. The proposed scheme utilizes the dual-coupled beams in the Rydberg atom vapor cell to reduce experimental errors and improve the measurement accuracy. The experimental results indicate that within the frequency measurement range from 11 to 18 GHz, the experimental error in measuring the DFS of different Rydberg states is within ±0.5 Hz, showcasing the wideband tunability of the system. Moreover, the AOA measurement for the echo signal reveal that the measurement error is less than 0.5° within the range from –30° to 35°. This research shows the first instance of simultaneously measuring DFS and AOA within the same Rydberg atom system. Additionally, by introducing the concept of ’relative frequency zero point’ in DFS measurement for the first time, the differentiation of the direction of the DFS can be identified. Furthermore, the accuracy of AOA measurement based on Rydberg atoms has been further improved in this research. Overall, this research provides a novel approach for measuring DFS and AOA using Rydberg atomic system.
Wide-range high-precision velocity detection with nitrogen-vacancy (NV) color center has been realized. By treating the NV color center as a mixer, the high-precision microwave measurement is realized. Through optimization of acquisition time, the microwave frequency resolution is improved to the mHz level. Combined with the frequency-velocity conversion model, velocity detection is realized in the range of 0-100 cm/s, and the velocity resolution is up to 0.012 cm/s. The maximum deviation in repeated measurements does not exceed 1/1000. Finally, combined with the multiplexed microwave reference technique, the range of velocity can be extended to 7.4 × 10 5 m/s. All of the results provide reference for high-precision velocity detection and play a significant role in various domains of quantum precision measurement. This study provides a crucial technical foundation for the development of high-dynamic-range velocity detectors and novel quantum precision velocity measurement technologies.
Diamond based quantum sensing is a fast-emerging field with both scientific and technological significance. The nitrogen–vacancy (NV) center, a crystal defect in diamond, has become a unique object for microwave sensing applications due to its excellent stability, long spin coherence time, and optical properties at ambient condition. In this work, we use diamond NV center as atomic receiver to demodulate on–off keying (OOK) signal transmitted in broad frequency range (2 GHz–14 GHz in a portable benchtop setup). We proposed a unique algorithm of voltage discrimination and demonstrated audio signal transceiving with fidelity above 99%. This diamond receiver is attached to the end of a tapered fiber, having all optic nature, which will find important applications in data transmission tasks under extreme conditions such as strong electromagnetic interference, high temperatures, and high corrosion.
Solid-state quantum sensors based on nitrogen-vacancy (NV) centers in diamond offer room-temperature operation, chemical stability, and a wide range of operating environments, and their application to microwave (MW) measurements are anticipated. In this study, we propose a method for quantitative MW field measurements under continuous-wave driving, referred to as the "NV Candle," aimed at realizing a solid-state quantum MW standard. Building on the atomic candle concept developed in atomic vapor systems, this method employs phase modulation of MW and resonance with Rabi oscillations to extract the Rabi frequency in the frequency domain. Experiments using NV centers in diamond demonstrated that the MW magnetic field derived from the NV Candle signals exhibited linearity over a 20 dB dynamic range. This work presents a novel approach to realize a solid-state quantum MW standard with enhanced robustness and practical applicability.
The determination of the angle of arrival (AoA) of Ku-band microwave signals is of great significance in satellite communications, spectrum monitoring, and national defense security, which has created an urgent demand for high-precision and interference-resistant passive detection techniques. In this study, we propose a Rydberg-atom-based passive measurement method for estimating the AoA of Ku-band incident signals. Based on well-established quantum optical techniques, the proposed method converts the EIT-AT splitting intervals induced by waves or signals incident from different directions in Rydberg atoms within a single vapor cell into the electric-field intensity at the atomic sensor. An electric-field-intensity-angle response model is then established for AoA estimation of a 13.6 GHz wave or signal. Simulation results demonstrate that the proposed method can determine the incident direction within a certain angular range, with an estimation error of less than 3.8°. Without the need for self-calibration and free from interference caused by actively emitted probing electromagnetic waves or reference electric fields, the proposed approach enables AoA determination of incident waves or signals using a single vapor cell with a length of 5 cm.
This study introduces a novel method for the simultaneous detection of microwave sensor power and temperature, leveraging nitrogen-vacancy (NV) centers as a robust quantum system. Through precise measurement of the optical detection magnetic resonance contrast in NV centers, the microwave power is accurately determined. Furthermore, the temperature of the sensor is obtained by monitoring the variations in zero-field splitting and thorough spectral analysis. This method enables the efficient real-time acquisition of synchronized data on both microwave power and temperature from the sensor, facilitating concurrent monitoring without the necessity of additional sensing devices. Finally, we verified that the magnetic sensitivity of the system is approximately 1.2 nT/Hz1/2, and the temperature sensitivity is around 0.38 mK/Hz1/2. The minimum resolution of microwave power is about 20 nW. The experimental results demonstrate that this quantum measurement technique provides stable and accurate data across a wide range of microwave power and temperature conditions. These findings indicate substantial potential for this technique in advanced applications such as aerospace, medical diagnostics, and high-frequency communications. Future studies will aim to extend the industrial applicability of this method by refining quantum control techniques within NV center systems.