Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Physics Conference Series

Characterization of magnetic field for loading, trapping and transferring cold atom close to the atom chip’s surface

Nuttida Kaewart, Nithiwadee Thaicharoen, Pimonpan Sompet, N Chattrapiban

Published Dec 1, 2023• 1 citation
Publisher

Abstract

Abstract Atom chips provide flexible technologies for implementing modern concepts in quantum optics, quantum measurement, and quantum information processing. Atom chips are miniature devices that confine, control and manipulate cold atoms using electric, magnetic, and light fields. Due to the shrinkage of scale, arbitrary magnetic traps can be generated from current sources outside the chip’s vacuum compartment, in contrast to a traditional setup. This makes it easy to change trap configurations in an experiment that involves rapid prototyping of quantum states and quantum trajectory designs in free space. In this work, we show relevant parameters needed for transferring a cold atom cloud at the recoil limit from a magneto-optical trap (MOT) to an area close to the atom chip. To create a movable magnetic potential for this transfer, we used the MOT coils and an additional pair of coils in an anti-Helmholtz configuration. The properties of the movable potential were obtained by performing the Computer Simulation Tool (CST EM Studio suite®). Furthermore, an appropriate magnetic trap on a chip is developed, based on the simulation from COMSOL Multiphysics. We used a magnetic field gradient of around 20 G/cm to transport the cold atom with a distance over 20 mm with a temperature gain below 100 micro-Kelvin. The simulation results are based on an atom chip with a size of 2×2 cm2 and a copper wire thickness of 2 mm. The atom chip consists of Z, U and I-shaped wires that generate a quadrupole magnetic field. The resulting field minimum can be made at least 7 mm away from the chip surface.

DOI
10.1088/1742-6596/2653/1/012039

Related papers

Direct loading of atoms from a macroscopic quadrupole magnetic trap into a microchip trap

Jun Jie Cheng, Jingfang Zhang, Xinping Xu +2 more

We demonstrate the direct loading of cold atoms into a microchip 2-mm Z-trap, where the evaporative cooling can be performed efficiently, from a macroscopic quadrupole magnetic trap with a high loading efficiency. The macroscopic quadrupole magnetic trap potential is designed to be moveable by controlling the currents of the two pairs of anti-Helmholtz coils. The cold atoms are initially prepared in a standard six-beam magneto-optical trap and loaded into the macroscopic quadrupole magnetic trap, and then transported to the atom chip surface by moving the macroscopic trap potential. By means of a three-dimensional absorption imaging system, we are able to optimize the position alignment of the atom cloud in the macroscopic trap and the microchip Z-shaped wire. Consequently, with a proper magnetic transfer scheme, we load the cold atoms into the microchip Z-trap directly and efficiently. The loading efficiency is measured to be about 50%. This approach can be used to generate appropriate ultracold atoms sources, for example, for a magnetically guided atom interferometer based on atom chip.

Chinese Physics B•Mar 1, 2017•3 citations

Micro-wire Magnetic Trap Chips for use in Ultracold Atom Experiments

Jacques Thibault

In order to take quantum mechanical systems out of the lab and produce practical devices, a method of miniaturizing and integrating apparatus components is needed. In the context of ultracold atomic gas experiments, the ideal method of achieving this miniaturization is the implementation of atom chip technology. By depositing micro-scale current carrying wires onto planar substrates, it is possible to create a magnetic trap capable of confining a cloud of neutral atoms in sufficient proximity to the chip surface for solid state devices to interact with the cloud. This thesis presents our lab’s first steps towards creating an atom chip capable of confining a cloud of rubidium-87. The chip prototypes were developed with the intent to incorporate them into the hybrid system apparatus within our lab. The chips are intended to serve as a platform for facilitating the interaction between the atomic gas ensemble and mesoscopic solid-state devices, allowing for the hybridization of the two systems. In this work I describe the design of the trapping wire configuration and the fabrication of the first two generations of chip prototypes. Additionally, I provide numerical simulations of the produced magnetic field, from which estimates of the trap frequency and depth can be calculated. Finally, I introduce some basic characterization tests of the absolute current limitations and resistive behavior of the chip wires, and the dimensional uniformity of the fabricated wire profiles.

•Jan 1, 2019•1 citation

Combined magnetic field system for atom chips

Xuemei Jia, Bowen Xu, Shuyu Zhou +1 more

In this paper, we have developed a combined magnetic field system to explore an alternative technical route for the generation of Bose–Einstein condensates containing numerous atoms on an atom chip. The system is characterized by the fact that the quadrupole magnetic field required by the magneto-optic trap is generated by U-shaped current-carrying wires combined with bias magnetic fields, whereas the quadrupole magnetic field adopted for the magnetic trap is generated by anti-Helmholtz coils. By fine-tuning the bias magnetic fields, the collection of atoms in the mirror MOT and the loading of the quadrupole magnetic trap can be optimized. The initial number of [Formula: see text]Rb atoms in the magnetic trap is approximately [Formula: see text], and the lifetime of the atoms is over 30 s. This scheme can facilitate the chip-surface design and is suitable for the precise manipulation of Bose–Einstein condensates near the chip surface.

Modern Physics Letters B•Dec 20, 2022•0 citations

On loading of a magneto-optical trap on an atom-chip with U-wire quadrupole field

Vivek Singh, Vibhuti Bhushan Tiwari, K. A. P. Singh +1 more

The role of U-wire generated quadrupole-like magnetic field profile on loading of cold 87Rb atoms in a magneto-optical trap (MOT) on atom-chip has been investigated. It is shown by simulations that the quadrupole field profile and the centre of the quadrupole field vary depending upon the U-wire current and bias field values. Moreover, the resemblance of generated field profile to the ideal quadrupole field critically depends on the values of current in U-wire and bias magnetic field. The observed number of trapped atoms in the MOT and its position has also been found to depend on the quadrupole field profile. The number of trapped atoms in the MOT reaches maximum when the field profile approaches close to an ideal quadrupole field. These studies are, in general, useful in optimizing the number in the MOT before transfer of these cold atoms to the microtraps of an atom-chip.

arXiv:1801.09461•Journal of Modern Optics•Aug 21, 2018•14 citations

A cold atom apparatus for the microscopy of thin membranes

Amruta Gadge

Ultracold atomic gases can be utilised as extremely sensitive probes of their surrounding environment. In particular, samples of ultracold atoms confined using chip-based microtraps are an ideal tool for mapping electric and magnetic field landscapes. Over the course of this thesis, a new experiment capable of performing surface microscopy using magnetically trapped clouds of cold rubidium-87 atoms has been built. The focus of the work is on the design and construction of the experimental system, which must incorporate many different aspects for manipulating thermal atomic gases, with a view to positioning them at sub-micron distances from special surfaces. This reduced atom-surface separation is necessary for implementing a high resolution, high sensitivity magnetic field sensor with cold atoms. Although current microfabrication techniques easily enable trapping at distances on the order of micrometres, several distance-dependent surface effects - such as the Casimir-Polder force, Johnson-Nyquist noise, and stray potentials - eventually impede magnetic trapping at the sub-micron level. These surface effects can greatly modify the confining potentials, which reduces the trap depth and consequently leads to an additional loss rate of atoms from the trap. We have explored the possibility of using special surfaces such as nano-membranes of silicon nitride and graphene, which have reduced atom- surface interactions, to enable trapping distances at the sub-micron level. A multilayer printed circuit board chip has been designed to form an initial magnetic trap and then transport the cloud of atoms to a desired location over the samples. This chip, along with various samples, is mounted on a custom-made electrical feedthrough designed to make connections to all conductor that are inside the vacuum chamber. The initial cloud of cold atoms can then be prepared in the central region of the chip and delivered to the location of the samples on either side. The experimental system is able to routinely capture over 10^8 rubidium-87 atoms at a temperature of 80 micro-Kelvin in a magneto-optical trap using a novel scheme of five laser beams. A method is demonstrated for enhancing the atom number in the magneto-optical traps by a factor of two by using laser beams with two slightly different frequencies. Atoms from the magneto-optical trap are then transferred to a purely magnetic trap formed by the wires on the printed circuit board chip. Time-dependent currents in the chip wires then create a dynamic potential, which is shown to successfully transport the atomic sample over a distance of 12 millimetre with minimal atom loss. This thesis describes the development of the apparatus in detail, along with careful characterisation of the cold cloud at various stages of the experimental sequence. Initial results on the long distance atom transport are presented. Finally, the experimental results of the two frequency magneto-optical trap for atom number improvement are discussed.

•Jul 19, 2018•0 citations

Efficient loading of a magnetic waveguide on an atom chip

Peter D. D. Schwindt, Eric Cornell, T. Kishimoto +2 more

We demonstrate efficient loading of neutral atoms into a magnetic waveguide produced by the magnetic fields of microfabricated current-carrying conductors. The lithographically patterned conductors on this ``atom chip'' can be used to make a variety of guiding and trapping structures for manipulating cold atoms and Bose-Einstein condensates. A three-chamber vacuum apparatus collects atoms in a magneto-optical trap, precools them via evaporative cooling, and delivers them to the final chamber containing the atom chip. We describe in detail how the precooled atomic cloud is transferred from a macroscopic magnetic Ioffe-Pritchard trap to the microscopic magnetic waveguide on the atom chip $21\phantom{\rule{0.3em}{0ex}}\mathrm{cm}$ away. Permanent magnets provide a confining two-dimensional quadrupole field to guide the atoms between the two chambers while longitudinally the cloud is allowed to freely expand during the transfer. Strategically placed coils are used to control the longitudinal size and speed of the atomic cloud as it is loaded on the atom chip.

Physical Review A•Aug 18, 2005•13 citations
Abstract Atom chips provide flexible technologies for implementing modern concepts in quantum optics, quantum measurement, and quantum information processing. Atom chips are miniature devices that confine, control and manipulate cold atoms using electric, magnetic, and light fields. Due to the shrinkage of scale, arbitrary magnetic traps can be generated from current sources outside the chip’s vacuum compartment, in contrast to a traditional setup. This makes it easy to change trap configurations in an experiment that involves rapid prototyping of quantum states and quantum trajectory designs in free space. In this work, we show relevant parameters needed for transferring a cold atom cloud at the recoil limit from a magneto-optical trap (MOT) to an area close to the atom chip. To create a movable magnetic potential for this transfer, we used the MOT coils and an additional pair of coils in an anti-Helmholtz configuration. The properties of the movable potential were obtained by performing the Computer Simulation Tool (CST EM Studio suite®). Furthermore, an appropriate magnetic trap on a chip is developed, based on the simulation from COMSOL Multiphysics. We used a magnetic field gradient of around 20 G/cm to transport the cold atom with a distance over 20 mm with a temperature gain below 100 micro-Kelvin. The simulation results are based on an atom chip with a size of 2×2 cm2 and a copper wire thickness of 2 mm. The atom chip consists of Z, U and I-shaped wires that generate a quadrupole magnetic field. The resulting field minimum can be made at least 7 mm away from the chip surface.
We demonstrate the direct loading of cold atoms into a microchip 2-mm Z-trap, where the evaporative cooling can be performed efficiently, from a macroscopic quadrupole magnetic trap with a high loading efficiency. The macroscopic quadrupole magnetic trap potential is designed to be moveable by controlling the currents of the two pairs of anti-Helmholtz coils. The cold atoms are initially prepared in a standard six-beam magneto-optical trap and loaded into the macroscopic quadrupole magnetic trap, and then transported to the atom chip surface by moving the macroscopic trap potential. By means of a three-dimensional absorption imaging system, we are able to optimize the position alignment of the atom cloud in the macroscopic trap and the microchip Z-shaped wire. Consequently, with a proper magnetic transfer scheme, we load the cold atoms into the microchip Z-trap directly and efficiently. The loading efficiency is measured to be about 50%. This approach can be used to generate appropriate ultracold atoms sources, for example, for a magnetically guided atom interferometer based on atom chip.
In order to take quantum mechanical systems out of the lab and produce practical devices, a method of miniaturizing and integrating apparatus components is needed. In the context of ultracold atomic gas experiments, the ideal method of achieving this miniaturization is the implementation of atom chip technology. By depositing micro-scale current carrying wires onto planar substrates, it is possible to create a magnetic trap capable of confining a cloud of neutral atoms in sufficient proximity to the chip surface for solid state devices to interact with the cloud. This thesis presents our lab’s first steps towards creating an atom chip capable of confining a cloud of rubidium-87. The chip prototypes were developed with the intent to incorporate them into the hybrid system apparatus within our lab. The chips are intended to serve as a platform for facilitating the interaction between the atomic gas ensemble and mesoscopic solid-state devices, allowing for the hybridization of the two systems. In this work I describe the design of the trapping wire configuration and the fabrication of the first two generations of chip prototypes. Additionally, I provide numerical simulations of the produced magnetic field, from which estimates of the trap frequency and depth can be calculated. Finally, I introduce some basic characterization tests of the absolute current limitations and resistive behavior of the chip wires, and the dimensional uniformity of the fabricated wire profiles.
In this paper, we have developed a combined magnetic field system to explore an alternative technical route for the generation of Bose–Einstein condensates containing numerous atoms on an atom chip. The system is characterized by the fact that the quadrupole magnetic field required by the magneto-optic trap is generated by U-shaped current-carrying wires combined with bias magnetic fields, whereas the quadrupole magnetic field adopted for the magnetic trap is generated by anti-Helmholtz coils. By fine-tuning the bias magnetic fields, the collection of atoms in the mirror MOT and the loading of the quadrupole magnetic trap can be optimized. The initial number of [Formula: see text]Rb atoms in the magnetic trap is approximately [Formula: see text], and the lifetime of the atoms is over 30 s. This scheme can facilitate the chip-surface design and is suitable for the precise manipulation of Bose–Einstein condensates near the chip surface.
The role of U-wire generated quadrupole-like magnetic field profile on loading of cold 87Rb atoms in a magneto-optical trap (MOT) on atom-chip has been investigated. It is shown by simulations that the quadrupole field profile and the centre of the quadrupole field vary depending upon the U-wire current and bias field values. Moreover, the resemblance of generated field profile to the ideal quadrupole field critically depends on the values of current in U-wire and bias magnetic field. The observed number of trapped atoms in the MOT and its position has also been found to depend on the quadrupole field profile. The number of trapped atoms in the MOT reaches maximum when the field profile approaches close to an ideal quadrupole field. These studies are, in general, useful in optimizing the number in the MOT before transfer of these cold atoms to the microtraps of an atom-chip.
Ultracold atomic gases can be utilised as extremely sensitive probes of their surrounding environment. In particular, samples of ultracold atoms confined using chip-based microtraps are an ideal tool for mapping electric and magnetic field landscapes. Over the course of this thesis, a new experiment capable of performing surface microscopy using magnetically trapped clouds of cold rubidium-87 atoms has been built. The focus of the work is on the design and construction of the experimental system, which must incorporate many different aspects for manipulating thermal atomic gases, with a view to positioning them at sub-micron distances from special surfaces. This reduced atom-surface separation is necessary for implementing a high resolution, high sensitivity magnetic field sensor with cold atoms. Although current microfabrication techniques easily enable trapping at distances on the order of micrometres, several distance-dependent surface effects - such as the Casimir-Polder force, Johnson-Nyquist noise, and stray potentials - eventually impede magnetic trapping at the sub-micron level. These surface effects can greatly modify the confining potentials, which reduces the trap depth and consequently leads to an additional loss rate of atoms from the trap. We have explored the possibility of using special surfaces such as nano-membranes of silicon nitride and graphene, which have reduced atom- surface interactions, to enable trapping distances at the sub-micron level. A multilayer printed circuit board chip has been designed to form an initial magnetic trap and then transport the cloud of atoms to a desired location over the samples. This chip, along with various samples, is mounted on a custom-made electrical feedthrough designed to make connections to all conductor that are inside the vacuum chamber. The initial cloud of cold atoms can then be prepared in the central region of the chip and delivered to the location of the samples on either side. The experimental system is able to routinely capture over 10^8 rubidium-87 atoms at a temperature of 80 micro-Kelvin in a magneto-optical trap using a novel scheme of five laser beams. A method is demonstrated for enhancing the atom number in the magneto-optical traps by a factor of two by using laser beams with two slightly different frequencies. Atoms from the magneto-optical trap are then transferred to a purely magnetic trap formed by the wires on the printed circuit board chip. Time-dependent currents in the chip wires then create a dynamic potential, which is shown to successfully transport the atomic sample over a distance of 12 millimetre with minimal atom loss. This thesis describes the development of the apparatus in detail, along with careful characterisation of the cold cloud at various stages of the experimental sequence. Initial results on the long distance atom transport are presented. Finally, the experimental results of the two frequency magneto-optical trap for atom number improvement are discussed.
We demonstrate efficient loading of neutral atoms into a magnetic waveguide produced by the magnetic fields of microfabricated current-carrying conductors. The lithographically patterned conductors on this ``atom chip'' can be used to make a variety of guiding and trapping structures for manipulating cold atoms and Bose-Einstein condensates. A three-chamber vacuum apparatus collects atoms in a magneto-optical trap, precools them via evaporative cooling, and delivers them to the final chamber containing the atom chip. We describe in detail how the precooled atomic cloud is transferred from a macroscopic magnetic Ioffe-Pritchard trap to the microscopic magnetic waveguide on the atom chip 21cm21\phantom{\rule{0.3em}{0ex}}\mathrm{cm}21cm away. Permanent magnets provide a confining two-dimensional quadrupole field to guide the atoms between the two chambers while longitudinally the cloud is allowed to freely expand during the transfer. Strategically placed coils are used to control the longitudinal size and speed of the atomic cloud as it is loaded on the atom chip.