Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review A

Efficient loading of a magnetic waveguide on an atom chip

Peter D. D. Schwindt, Eric Cornell, T. Kishimoto, Ying-Ju Wang, Dana Z. Anderson

Published Aug 18, 2005• 13 citations
Publisher

Abstract

We demonstrate efficient loading of neutral atoms into a magnetic waveguide produced by the magnetic fields of microfabricated current-carrying conductors. The lithographically patterned conductors on this ``atom chip'' can be used to make a variety of guiding and trapping structures for manipulating cold atoms and Bose-Einstein condensates. A three-chamber vacuum apparatus collects atoms in a magneto-optical trap, precools them via evaporative cooling, and delivers them to the final chamber containing the atom chip. We describe in detail how the precooled atomic cloud is transferred from a macroscopic magnetic Ioffe-Pritchard trap to the microscopic magnetic waveguide on the atom chip $21\phantom{\rule{0.3em}{0ex}}\mathrm{cm}$ away. Permanent magnets provide a confining two-dimensional quadrupole field to guide the atoms between the two chambers while longitudinally the cloud is allowed to freely expand during the transfer. Strategically placed coils are used to control the longitudinal size and speed of the atomic cloud as it is loaded on the atom chip.

DOI
10.1103/physreva.72.023612

Related papers

Direct loading of atoms from a macroscopic quadrupole magnetic trap into a microchip trap

Jun Jie Cheng, Jingfang Zhang, Xinping Xu +2 more

We demonstrate the direct loading of cold atoms into a microchip 2-mm Z-trap, where the evaporative cooling can be performed efficiently, from a macroscopic quadrupole magnetic trap with a high loading efficiency. The macroscopic quadrupole magnetic trap potential is designed to be moveable by controlling the currents of the two pairs of anti-Helmholtz coils. The cold atoms are initially prepared in a standard six-beam magneto-optical trap and loaded into the macroscopic quadrupole magnetic trap, and then transported to the atom chip surface by moving the macroscopic trap potential. By means of a three-dimensional absorption imaging system, we are able to optimize the position alignment of the atom cloud in the macroscopic trap and the microchip Z-shaped wire. Consequently, with a proper magnetic transfer scheme, we load the cold atoms into the microchip Z-trap directly and efficiently. The loading efficiency is measured to be about 50%. This approach can be used to generate appropriate ultracold atoms sources, for example, for a magnetically guided atom interferometer based on atom chip.

Chinese Physics B•Mar 1, 2017•3 citations

Practical scheme to realize 2D array of BECs on an atom chip: novel 2D magneto-optical and magnetic lattices

Min Yun, Jianping Yin

An array of square current-carrying wires is proposed to construct a two-dimensional (2D) array of surface magneto-optical traps and Ioffe magnetic ones for realizing a 2D lattice of Bose-Einstein condensations (BECs) on an atom chip. Our study shows that when a vertical homogeneous bias magnetic field is only used, the wires will form a 2D array of quadrupole magnetic traps, which can be used to construct 2D lattice of surface magneto-optical micro-traps. While another horizontal homogeneous bias field is added simultaneously, the above 2D array of quadrupole micro-traps will be changed as an array of surface Ioffe micro-traps, which can be used to form a 2D magnetic lattice and then realize a 2D array of BECs. The dynamic loading process of cold (87)Rb atoms from each micro-MOT into Ioffe micro-trap is studied by using Monte-Carlo simulations, and our results show that the scheme can be used to realize a natural and effective loading of cold atoms from 2D array of micro-MOTs into 2D array of Ioffe micro-traps, and the loading efficiency can be reach ~ 65%. Moreover, the positions of each BEC (or MOT) in 2D array of magnetic micro-traps can be controlled by adjusting the currents in the wires or by changing the additional vertical bias field.

Optics Express•Jan 1, 2006•9 citations

Characterization of magnetic field for loading, trapping and transferring cold atom close to the atom chip’s surface

Nuttida Kaewart, Nithiwadee Thaicharoen, Pimonpan Sompet +1 more

Abstract Atom chips provide flexible technologies for implementing modern concepts in quantum optics, quantum measurement, and quantum information processing. Atom chips are miniature devices that confine, control and manipulate cold atoms using electric, magnetic, and light fields. Due to the shrinkage of scale, arbitrary magnetic traps can be generated from current sources outside the chip’s vacuum compartment, in contrast to a traditional setup. This makes it easy to change trap configurations in an experiment that involves rapid prototyping of quantum states and quantum trajectory designs in free space. In this work, we show relevant parameters needed for transferring a cold atom cloud at the recoil limit from a magneto-optical trap (MOT) to an area close to the atom chip. To create a movable magnetic potential for this transfer, we used the MOT coils and an additional pair of coils in an anti-Helmholtz configuration. The properties of the movable potential were obtained by performing the Computer Simulation Tool (CST EM Studio suite®). Furthermore, an appropriate magnetic trap on a chip is developed, based on the simulation from COMSOL Multiphysics. We used a magnetic field gradient of around 20 G/cm to transport the cold atom with a distance over 20 mm with a temperature gain below 100 micro-Kelvin. The simulation results are based on an atom chip with a size of 2×2 cm2 and a copper wire thickness of 2 mm. The atom chip consists of Z, U and I-shaped wires that generate a quadrupole magnetic field. The resulting field minimum can be made at least 7 mm away from the chip surface.

Journal of Physics Conference Series•Dec 1, 2023•1 citation

Atomic Micromanipulation with Magnetic Surface Traps

Jakob Reichel, W. Hänsel, Theodor W. Hänsch

We describe manipulation of neutral atoms using the magnetic field of microfabricated current-carrying conductors. It is shown how this method can be used to achieve adiabatic magnetic transport from one reservoir to another. In the first experimental realization of a microfabricated magnetic neutral-atom trap, efficient loading is achieved with a novel mirror-magneto-optic trap. A cloud of rubidium atoms is stored and compressed using the magnetic field of a ``U''-shaped wire carrying a current of 2 A. An evaporation mechanism is demonstrated which removes hot atoms from the trap by collisions with the substrate surface.

Physical Review Letters•Oct 25, 1999•412 citations

Manipulating Neutral Atoms in Chip-Based Magnetic Traps

David C. Aveline, Robert J. Thompson, Nathan E. Lundblad +3 more

Several techniques for manipulating neutral atoms (more precisely, ultracold clouds of neutral atoms) in chip-based magnetic traps and atomic waveguides have been demonstrated. Such traps and waveguides are promising components of future quantum sensors that would offer sensitivities much greater than those of conventional sensors. Potential applications include gyroscopy and basic research in physical phenomena that involve gravitational and/or electromagnetic fields. The developed techniques make it possible to control atoms with greater versatility and dexterity than were previously possible and, hence, can be expected to contribute to the value of chip-based magnetic traps and atomic waveguides. The basic principle of these techniques is to control gradient magnetic fields with suitable timing so as to alter a trap to exert position-, velocity-, and/or time-dependent forces on atoms in the trap to obtain desired effects. The trap magnetic fields are generated by controlled electric currents flowing in both macroscopic off-chip electromagnet coils and microscopic wires on the surface of the chip. The methods are best explained in terms of examples. Rather than simply allowing atoms to expand freely into an atomic waveguide, one can give them a controllable push by switching on an externally generated or a chip-based gradient magnetic field. This push can increase the speed of the atoms, typically from about 5 to about 20 cm/s. Applying a non-linear magnetic-field gradient exerts different forces on atoms in different positions a phenomenon that one can exploit by introducing a delay between releasing atoms into the waveguide and turning on the magnetic field.

•May 1, 2009•1 citation

Guiding Neutral Atoms with Two Current-Carrying Wires and a Vertical Bias Field on the Atom Chip

Ke Min, Xiaolin Li, Yuzhu Wang

We demonstrate the guiding of neutral atoms with two parallel microfabricated current-carrying wires on the atom chip and a vertical magnetic bias field. The atoms are guided along a magnetic field minimum parallel to the current-carrying wires and confined in the other two directions. We describe in detail how the precooled atoms are efficiently loaded into the two-wire guide. We present a detailed experimental study of the motional properties of the atoms in the guide and the relationship between the location of the guide and the vertical bias field. This two-wire guide with vertical bias field can be used to realize large area atom interferometer.

Chinese Physics Letters•Mar 1, 2008•5 citations
We demonstrate efficient loading of neutral atoms into a magnetic waveguide produced by the magnetic fields of microfabricated current-carrying conductors. The lithographically patterned conductors on this ``atom chip'' can be used to make a variety of guiding and trapping structures for manipulating cold atoms and Bose-Einstein condensates. A three-chamber vacuum apparatus collects atoms in a magneto-optical trap, precools them via evaporative cooling, and delivers them to the final chamber containing the atom chip. We describe in detail how the precooled atomic cloud is transferred from a macroscopic magnetic Ioffe-Pritchard trap to the microscopic magnetic waveguide on the atom chip 21cm21\phantom{\rule{0.3em}{0ex}}\mathrm{cm}21cm away. Permanent magnets provide a confining two-dimensional quadrupole field to guide the atoms between the two chambers while longitudinally the cloud is allowed to freely expand during the transfer. Strategically placed coils are used to control the longitudinal size and speed of the atomic cloud as it is loaded on the atom chip.
We demonstrate the direct loading of cold atoms into a microchip 2-mm Z-trap, where the evaporative cooling can be performed efficiently, from a macroscopic quadrupole magnetic trap with a high loading efficiency. The macroscopic quadrupole magnetic trap potential is designed to be moveable by controlling the currents of the two pairs of anti-Helmholtz coils. The cold atoms are initially prepared in a standard six-beam magneto-optical trap and loaded into the macroscopic quadrupole magnetic trap, and then transported to the atom chip surface by moving the macroscopic trap potential. By means of a three-dimensional absorption imaging system, we are able to optimize the position alignment of the atom cloud in the macroscopic trap and the microchip Z-shaped wire. Consequently, with a proper magnetic transfer scheme, we load the cold atoms into the microchip Z-trap directly and efficiently. The loading efficiency is measured to be about 50%. This approach can be used to generate appropriate ultracold atoms sources, for example, for a magnetically guided atom interferometer based on atom chip.
An array of square current-carrying wires is proposed to construct a two-dimensional (2D) array of surface magneto-optical traps and Ioffe magnetic ones for realizing a 2D lattice of Bose-Einstein condensations (BECs) on an atom chip. Our study shows that when a vertical homogeneous bias magnetic field is only used, the wires will form a 2D array of quadrupole magnetic traps, which can be used to construct 2D lattice of surface magneto-optical micro-traps. While another horizontal homogeneous bias field is added simultaneously, the above 2D array of quadrupole micro-traps will be changed as an array of surface Ioffe micro-traps, which can be used to form a 2D magnetic lattice and then realize a 2D array of BECs. The dynamic loading process of cold (87)Rb atoms from each micro-MOT into Ioffe micro-trap is studied by using Monte-Carlo simulations, and our results show that the scheme can be used to realize a natural and effective loading of cold atoms from 2D array of micro-MOTs into 2D array of Ioffe micro-traps, and the loading efficiency can be reach ~ 65%. Moreover, the positions of each BEC (or MOT) in 2D array of magnetic micro-traps can be controlled by adjusting the currents in the wires or by changing the additional vertical bias field.
Abstract Atom chips provide flexible technologies for implementing modern concepts in quantum optics, quantum measurement, and quantum information processing. Atom chips are miniature devices that confine, control and manipulate cold atoms using electric, magnetic, and light fields. Due to the shrinkage of scale, arbitrary magnetic traps can be generated from current sources outside the chip’s vacuum compartment, in contrast to a traditional setup. This makes it easy to change trap configurations in an experiment that involves rapid prototyping of quantum states and quantum trajectory designs in free space. In this work, we show relevant parameters needed for transferring a cold atom cloud at the recoil limit from a magneto-optical trap (MOT) to an area close to the atom chip. To create a movable magnetic potential for this transfer, we used the MOT coils and an additional pair of coils in an anti-Helmholtz configuration. The properties of the movable potential were obtained by performing the Computer Simulation Tool (CST EM Studio suite®). Furthermore, an appropriate magnetic trap on a chip is developed, based on the simulation from COMSOL Multiphysics. We used a magnetic field gradient of around 20 G/cm to transport the cold atom with a distance over 20 mm with a temperature gain below 100 micro-Kelvin. The simulation results are based on an atom chip with a size of 2×2 cm2 and a copper wire thickness of 2 mm. The atom chip consists of Z, U and I-shaped wires that generate a quadrupole magnetic field. The resulting field minimum can be made at least 7 mm away from the chip surface.
We describe manipulation of neutral atoms using the magnetic field of microfabricated current-carrying conductors. It is shown how this method can be used to achieve adiabatic magnetic transport from one reservoir to another. In the first experimental realization of a microfabricated magnetic neutral-atom trap, efficient loading is achieved with a novel mirror-magneto-optic trap. A cloud of rubidium atoms is stored and compressed using the magnetic field of a ``U''-shaped wire carrying a current of 2 A. An evaporation mechanism is demonstrated which removes hot atoms from the trap by collisions with the substrate surface.
Several techniques for manipulating neutral atoms (more precisely, ultracold clouds of neutral atoms) in chip-based magnetic traps and atomic waveguides have been demonstrated. Such traps and waveguides are promising components of future quantum sensors that would offer sensitivities much greater than those of conventional sensors. Potential applications include gyroscopy and basic research in physical phenomena that involve gravitational and/or electromagnetic fields. The developed techniques make it possible to control atoms with greater versatility and dexterity than were previously possible and, hence, can be expected to contribute to the value of chip-based magnetic traps and atomic waveguides. The basic principle of these techniques is to control gradient magnetic fields with suitable timing so as to alter a trap to exert position-, velocity-, and/or time-dependent forces on atoms in the trap to obtain desired effects. The trap magnetic fields are generated by controlled electric currents flowing in both macroscopic off-chip electromagnet coils and microscopic wires on the surface of the chip. The methods are best explained in terms of examples. Rather than simply allowing atoms to expand freely into an atomic waveguide, one can give them a controllable push by switching on an externally generated or a chip-based gradient magnetic field. This push can increase the speed of the atoms, typically from about 5 to about 20 cm/s. Applying a non-linear magnetic-field gradient exerts different forces on atoms in different positions a phenomenon that one can exploit by introducing a delay between releasing atoms into the waveguide and turning on the magnetic field.
We demonstrate the guiding of neutral atoms with two parallel microfabricated current-carrying wires on the atom chip and a vertical magnetic bias field. The atoms are guided along a magnetic field minimum parallel to the current-carrying wires and confined in the other two directions. We describe in detail how the precooled atoms are efficiently loaded into the two-wire guide. We present a detailed experimental study of the motional properties of the atoms in the guide and the relationship between the location of the guide and the vertical bias field. This two-wire guide with vertical bias field can be used to realize large area atom interferometer.