Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEEE Sensors Journal

Measurement of Relaxation Mechanism for the Spin-Exchange Relaxation-Free Magnetometer

Jin Peng, An‐Ning Xu, Yiran Yin, Bei Liu

Published Dec 7, 2023• 11 citations
Publisher

Abstract

The spin-exchange relaxation-free (SERF) atomic magnetometer (AM) has vital importance in advanced research and has been widely applied in different fields. To improve the sensitivity and robustness of SERF magnetometers, understanding the relaxation mechanism is a significant approach. By controlling the amplitude and direction of external magnetic fields, and switching statuses of the pump and probe laser beam, we measured both the transverse and longitudinal relaxation rate in two experimental methods, respectively, and obtained the Larmor precession frequency, the spin-exchange relaxation rate, the spin-destruction relaxation rate, and the relaxation rate due to collisions between atoms and vapor cell walls. All experimental results are verified with the theoretical calculations. The final longitudinal relaxation rate of our magnetometer is 53 Hz. Furthermore, we measured the sensitivity of our SERF magnetometer reaching 5 fT/Hz1/2 from 5 to 70 Hz after differential measurement with the 3-dB bandwidth of 70 Hz. Our work helps to improve the detection capability of SERF magnetometers, providing performance assurance for searching for exotic spin-dependent interactions and applications, including magnetoencephalograms and magnetocardiograms.

DOI
10.1109/jsen.2023.3334710

Related papers

A fast determination method for identifying the spin exchange relaxation free regime of atomic magnetometer

Yanzhang Wang, Xue Zhang, Jianan Qin +1 more

Spin-exchange-relaxation-free (SERF) atomic magnetometer is the most sensitive magnetic detector in the world at present due to the fact that the broadening of spin-exchange collision is eliminated by operating at high alkali-mental density and low magnetic field. On that condition, the precession frequency of high-density alkali vapor becomes a constant fractional value of Larmor frequency, and the width of magnetic-resonance line gets narrower. This paper analyzes the principle of SERF regime and proposes an innovation based on measuring the slowing-down Larmor frequency directly instead of the complicated conventional method based on the width of magnetic resonance line. We calculated and simulated the slowing-down precession frequency and linewidth of magnetic resonance on certain conditions. The experimental results have verified that the method is valid to identify the regime of SERF of atomic magnetometer via detecting the slowing-down precession frequency.

Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ...•Oct 1, 2016•1 citation

A Fast Identification on the Spin-Exchange Relaxation-Free Regime of Atomic Magnetometer Exploiting Measurement on Gyromagnetic Ratio

Xue Zhang, Jianan Qin, Yanzhang Wang +1 more

Spin-exchange relaxation-free (SERF) atomic magnetometers seem to be the state-of-the-art magnetic sensors today as they have achieved a sensitivity of femtotesla in the elimination of broadening contribution of spin-exchange collisions operated in the mode of SERF regime. In order to extend the practicability of SERF atomic magnetometry in superb performances in a movable platform, ensuring and testing the working status of alkali atoms are of great importance. Given the fact that in the premise of SERF regime, the linewidth of magnetic resonance would be narrowing down and the precession frequency would become a constant fractional value of the Larmor frequency for alkali atoms, we measure the gyromagnetic ratio of weakly polarized alkali-metal vapor by yielding the damped oscillating curves and fitting measured increments of frequency and magnetic field to identify the working regime of alkali atoms in a fast and straightforward manner. The experimental results have good agreements with theoretical analysis and simulation, and the whole measurement process lasts milliseconds with relatively measured error ±1% in the temperature range of T = 156 °C-184 °C. To testify the validity of the innovation, magnetic resonance line is obtained in the same condition proffering the width comparative with the outcome from simulation, indicating the spin-exchange broadening has been eliminated, presenting the same conclusion with innovation, and providing systematic sensitivity 30 fT/Hz1/2.

IEEE Transactions on Instrumentation and Measurement•Aug 24, 2018•35 citations

A Fast Determination Method for Transverse Relaxation Rate of Minimized SERF Atomic Magnetometer

Le Jia, Xinda Song, Jianli Li +4 more

The sensitivity and bandwidth (BW) as the primary criteria of spin-exchange relaxation-free (SERF) atomic magnetometer (AM) are closely related to the transverse relaxation rate of atomic ensemble. In this study, we show an effective method for transverse relaxation rate measurement drawing on the golden Section algorithm. With no requirement of offline fitting, the measuring time of this method is only 7 s. This is especially advantageous for reducing measurement errors due to the drifts of spatial magnetic field and light intensity and using multiple measurements to better monitor the performance of magnetometers. Moreover, the reset after measuring is optimized as the sensitive axis magnetic field correction, ensuring the integrity of measurement while improving the accuracy of magnetic compensation. Furthermore, we find that the acquired experimental data using this method can be adopted for the evaluation of magnetic field compensation performance and the monitoring of magnetic anomaly states. This determination method for transverse relaxation rate is anticipated to play a greater important role in multichannel SERF AMs’ arrays.

IEEE Sensors Journal•Apr 28, 2023•5 citations

Fast extraction of the electron spin-relaxation rate in the SERF magnetometer from a transient response

Yanning Ma, Kaixuan Zhang, Yaoguo Wang +3 more

The magnitude of the electron spin-relaxation rate Rrel of the atomic ensemble directly affects the sensitivity of the spin-exchange relaxation-free (SERF) atomic magnetometer (AM). The rapid and in-situ characterization of Rrel is of great importance. In this work, a fast extraction method of Rrel is proposed with a measurement period shorten to 0.5 s, merely detecting the transient response of SERF AM to a transverse DC excitation magnetic field after switching off the pump beam. In contrast to the conventional methods based on the measurement of the magnetic resonance linewidth, this method circumvents the involvement of optical pumping rate, and enables monitoring Rrel under arbitrary polarization, which is expected to improve the authenticity of Rrel measurement in a more convenient way.

Optics Express•May 2, 2022•12 citations

A Performance-Enhanced Closed-Loop SERF Atomic Magnetometer

Ziao Liu, Jianli Li, Xiaoyu Li +3 more

The spin-exchange relaxation-free (SERF) atomic magnetometers (AMs) exhibit ultrahigh sensitivity in ultraweak magnetic field measurement, but their narrow bandwidth constrains the scope of their applications. To increase the bandwidth, magnetic field closed-loop control technology has been introduced into AMs with demonstrated efficacy. However, previous research on closed-loop AMs resulted in signal distortion problems, primarily due to imprecise closed-loop models and control parameters selection without theoretical support. This problem is specifically characterized by the unexpected amplification or reduction of signals at certain frequencies, directly leading to the degradation of the frequency performance of the closed-loop AM, making it unsuitable for applications requiring full-bandwidth measurement. In this study, we proposed a performance-enhanced closed-loop SERF AM, maximizing the bandwidth while ensuring consistent performance across the entire bandwidth. An accurate closed-loop system model was first established. Subsequently, an optimal relationship between the control parameters was proposed according to the eigenvalues of the closed-loop system, and the particle swarm optimization (PSO) algorithm was introduced to determine the optimal control parameters. The improved closed-loop system was constructed in a triaxial SERF AM, achieving an average bandwidth of 410 Hz and a sensitivity of 10 fT/Hz$^{{1}/{2}}$in three axes, while ensuring consistent performance across the entire bandwidth. With the proposed method, the optimized control parameters can be obtained only by requiring the frequency response of the open-loop AM, which is convenient and useful for closed-loop AM applications.

IEEE Sensors Journal•Oct 1, 2024•5 citations

A High Sensitivity Closed-Loop Spin-Exchange Relaxation-Free Atomic Magnetometer With Broad Bandwidth

Qingqian Guo, Tao Hu, Chun-qiao Chen +6 more

Spin-exchange relaxation-free (SERF) atomic magnetometers are the promising non-cryogenic sensors to potentially replace the superconducting quantum interference device (SQUID) in the ultra-weak magnetic-field measurements. Although the SERF magnetometers have achieved a sensitivity of sub-femtotesla, the bandwidth is limited at a narrow range. In this work, we developed a closed-loop SERF magnetometer under proportional-integral (PI) control, the bandwidth could be adaptively tuned and extended above 1.2 kHz. A nearly 40-fold enhancement of the typical bandwidth was achieved in comparison with the open-loop system and the sensitivity was maintained at 15 fT/Hz1/2from 30 Hz to 750 Hz. Moreover, the magnetic field dynamic range could also be greatly improved. This proposed atomic magnetometer with higher bandwidth, sensitivity, and dynamic range has a good prospect in developing a compact, portable, and non-cryogenic magnetic field sensor and may find more applications in biomedical, nuclear magnetic resonance, and fundamental physics research.

IEEE Sensors Journal•Aug 3, 2021•36 citations
The spin-exchange relaxation-free (SERF) atomic magnetometer (AM) has vital importance in advanced research and has been widely applied in different fields. To improve the sensitivity and robustness of SERF magnetometers, understanding the relaxation mechanism is a significant approach. By controlling the amplitude and direction of external magnetic fields, and switching statuses of the pump and probe laser beam, we measured both the transverse and longitudinal relaxation rate in two experimental methods, respectively, and obtained the Larmor precession frequency, the spin-exchange relaxation rate, the spin-destruction relaxation rate, and the relaxation rate due to collisions between atoms and vapor cell walls. All experimental results are verified with the theoretical calculations. The final longitudinal relaxation rate of our magnetometer is 53 Hz. Furthermore, we measured the sensitivity of our SERF magnetometer reaching 5 fT/Hz1/2 from 5 to 70 Hz after differential measurement with the 3-dB bandwidth of 70 Hz. Our work helps to improve the detection capability of SERF magnetometers, providing performance assurance for searching for exotic spin-dependent interactions and applications, including magnetoencephalograms and magnetocardiograms.
Spin-exchange-relaxation-free (SERF) atomic magnetometer is the most sensitive magnetic detector in the world at present due to the fact that the broadening of spin-exchange collision is eliminated by operating at high alkali-mental density and low magnetic field. On that condition, the precession frequency of high-density alkali vapor becomes a constant fractional value of Larmor frequency, and the width of magnetic-resonance line gets narrower. This paper analyzes the principle of SERF regime and proposes an innovation based on measuring the slowing-down Larmor frequency directly instead of the complicated conventional method based on the width of magnetic resonance line. We calculated and simulated the slowing-down precession frequency and linewidth of magnetic resonance on certain conditions. The experimental results have verified that the method is valid to identify the regime of SERF of atomic magnetometer via detecting the slowing-down precession frequency.
Spin-exchange relaxation-free (SERF) atomic magnetometers seem to be the state-of-the-art magnetic sensors today as they have achieved a sensitivity of femtotesla in the elimination of broadening contribution of spin-exchange collisions operated in the mode of SERF regime. In order to extend the practicability of SERF atomic magnetometry in superb performances in a movable platform, ensuring and testing the working status of alkali atoms are of great importance. Given the fact that in the premise of SERF regime, the linewidth of magnetic resonance would be narrowing down and the precession frequency would become a constant fractional value of the Larmor frequency for alkali atoms, we measure the gyromagnetic ratio of weakly polarized alkali-metal vapor by yielding the damped oscillating curves and fitting measured increments of frequency and magnetic field to identify the working regime of alkali atoms in a fast and straightforward manner. The experimental results have good agreements with theoretical analysis and simulation, and the whole measurement process lasts milliseconds with relatively measured error ±1% in the temperature range of T = 156 °C-184 °C. To testify the validity of the innovation, magnetic resonance line is obtained in the same condition proffering the width comparative with the outcome from simulation, indicating the spin-exchange broadening has been eliminated, presenting the same conclusion with innovation, and providing systematic sensitivity 30 fT/Hz1/2.
The sensitivity and bandwidth (BW) as the primary criteria of spin-exchange relaxation-free (SERF) atomic magnetometer (AM) are closely related to the transverse relaxation rate of atomic ensemble. In this study, we show an effective method for transverse relaxation rate measurement drawing on the golden Section algorithm. With no requirement of offline fitting, the measuring time of this method is only 7 s. This is especially advantageous for reducing measurement errors due to the drifts of spatial magnetic field and light intensity and using multiple measurements to better monitor the performance of magnetometers. Moreover, the reset after measuring is optimized as the sensitive axis magnetic field correction, ensuring the integrity of measurement while improving the accuracy of magnetic compensation. Furthermore, we find that the acquired experimental data using this method can be adopted for the evaluation of magnetic field compensation performance and the monitoring of magnetic anomaly states. This determination method for transverse relaxation rate is anticipated to play a greater important role in multichannel SERF AMs’ arrays.
The magnitude of the electron spin-relaxation rate Rrel of the atomic ensemble directly affects the sensitivity of the spin-exchange relaxation-free (SERF) atomic magnetometer (AM). The rapid and in-situ characterization of Rrel is of great importance. In this work, a fast extraction method of Rrel is proposed with a measurement period shorten to 0.5 s, merely detecting the transient response of SERF AM to a transverse DC excitation magnetic field after switching off the pump beam. In contrast to the conventional methods based on the measurement of the magnetic resonance linewidth, this method circumvents the involvement of optical pumping rate, and enables monitoring Rrel under arbitrary polarization, which is expected to improve the authenticity of Rrel measurement in a more convenient way.
The spin-exchange relaxation-free (SERF) atomic magnetometers (AMs) exhibit ultrahigh sensitivity in ultraweak magnetic field measurement, but their narrow bandwidth constrains the scope of their applications. To increase the bandwidth, magnetic field closed-loop control technology has been introduced into AMs with demonstrated efficacy. However, previous research on closed-loop AMs resulted in signal distortion problems, primarily due to imprecise closed-loop models and control parameters selection without theoretical support. This problem is specifically characterized by the unexpected amplification or reduction of signals at certain frequencies, directly leading to the degradation of the frequency performance of the closed-loop AM, making it unsuitable for applications requiring full-bandwidth measurement. In this study, we proposed a performance-enhanced closed-loop SERF AM, maximizing the bandwidth while ensuring consistent performance across the entire bandwidth. An accurate closed-loop system model was first established. Subsequently, an optimal relationship between the control parameters was proposed according to the eigenvalues of the closed-loop system, and the particle swarm optimization (PSO) algorithm was introduced to determine the optimal control parameters. The improved closed-loop system was constructed in a triaxial SERF AM, achieving an average bandwidth of 410 Hz and a sensitivity of 10 fT/Hz1/2^{{1}/{2}}1/2in three axes, while ensuring consistent performance across the entire bandwidth. With the proposed method, the optimized control parameters can be obtained only by requiring the frequency response of the open-loop AM, which is convenient and useful for closed-loop AM applications.
Spin-exchange relaxation-free (SERF) atomic magnetometers are the promising non-cryogenic sensors to potentially replace the superconducting quantum interference device (SQUID) in the ultra-weak magnetic-field measurements. Although the SERF magnetometers have achieved a sensitivity of sub-femtotesla, the bandwidth is limited at a narrow range. In this work, we developed a closed-loop SERF magnetometer under proportional-integral (PI) control, the bandwidth could be adaptively tuned and extended above 1.2 kHz. A nearly 40-fold enhancement of the typical bandwidth was achieved in comparison with the open-loop system and the sensitivity was maintained at 15 fT/Hz1/2from 30 Hz to 750 Hz. Moreover, the magnetic field dynamic range could also be greatly improved. This proposed atomic magnetometer with higher bandwidth, sensitivity, and dynamic range has a good prospect in developing a compact, portable, and non-cryogenic magnetic field sensor and may find more applications in biomedical, nuclear magnetic resonance, and fundamental physics research.