IEEE Transactions on Instrumentation and Measurement

A Fast Identification on the Spin-Exchange Relaxation-Free Regime of Atomic Magnetometer Exploiting Measurement on Gyromagnetic Ratio

Xue Zhang, Jianan Qin, Yanzhang Wang, Chen Chen

Published Aug 24, 2018• 35 citations
Publisher

Abstract

Spin-exchange relaxation-free (SERF) atomic magnetometers seem to be the state-of-the-art magnetic sensors today as they have achieved a sensitivity of femtotesla in the elimination of broadening contribution of spin-exchange collisions operated in the mode of SERF regime. In order to extend the practicability of SERF atomic magnetometry in superb performances in a movable platform, ensuring and testing the working status of alkali atoms are of great importance. Given the fact that in the premise of SERF regime, the linewidth of magnetic resonance would be narrowing down and the precession frequency would become a constant fractional value of the Larmor frequency for alkali atoms, we measure the gyromagnetic ratio of weakly polarized alkali-metal vapor by yielding the damped oscillating curves and fitting measured increments of frequency and magnetic field to identify the working regime of alkali atoms in a fast and straightforward manner. The experimental results have good agreements with theoretical analysis and simulation, and the whole measurement process lasts milliseconds with relatively measured error ±1% in the temperature range of T = 156 °C-184 °C. To testify the validity of the innovation, magnetic resonance line is obtained in the same condition proffering the width comparative with the outcome from simulation, indicating the spin-exchange broadening has been eliminated, presenting the same conclusion with innovation, and providing systematic sensitivity 30 fT/Hz1/2.

DOI
10.1109/tim.2018.2863519

Related papers

A fast determination method for identifying the spin exchange relaxation free regime of atomic magnetometer

Yanzhang Wang, Xue Zhang, Jianan Qin +1 more

Spin-exchange-relaxation-free (SERF) atomic magnetometer is the most sensitive magnetic detector in the world at present due to the fact that the broadening of spin-exchange collision is eliminated by operating at high alkali-mental density and low magnetic field. On that condition, the precession frequency of high-density alkali vapor becomes a constant fractional value of Larmor frequency, and the width of magnetic-resonance line gets narrower. This paper analyzes the principle of SERF regime and proposes an innovation based on measuring the slowing-down Larmor frequency directly instead of the complicated conventional method based on the width of magnetic resonance line. We calculated and simulated the slowing-down precession frequency and linewidth of magnetic resonance on certain conditions. The experimental results have verified that the method is valid to identify the regime of SERF of atomic magnetometer via detecting the slowing-down precession frequency.

Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ...•Oct 1, 2016•1 citation

Measurement of Relaxation Mechanism for the Spin-Exchange Relaxation-Free Magnetometer

Jin Peng, An‐Ning Xu, Yiran Yin +1 more

The spin-exchange relaxation-free (SERF) atomic magnetometer (AM) has vital importance in advanced research and has been widely applied in different fields. To improve the sensitivity and robustness of SERF magnetometers, understanding the relaxation mechanism is a significant approach. By controlling the amplitude and direction of external magnetic fields, and switching statuses of the pump and probe laser beam, we measured both the transverse and longitudinal relaxation rate in two experimental methods, respectively, and obtained the Larmor precession frequency, the spin-exchange relaxation rate, the spin-destruction relaxation rate, and the relaxation rate due to collisions between atoms and vapor cell walls. All experimental results are verified with the theoretical calculations. The final longitudinal relaxation rate of our magnetometer is 53 Hz. Furthermore, we measured the sensitivity of our SERF magnetometer reaching 5 fT/Hz1/2 from 5 to 70 Hz after differential measurement with the 3-dB bandwidth of 70 Hz. Our work helps to improve the detection capability of SERF magnetometers, providing performance assurance for searching for exotic spin-dependent interactions and applications, including magnetoencephalograms and magnetocardiograms.

IEEE Sensors Journal•Dec 7, 2023•11 citations

Spin-exchange-relaxation-free magnetometry with Cs vapor

M. P. Ledbetter, Igor Savukov, Víctor M. Acosta +2 more

We describe a Cs atomic magnetometer operating in the spin-exchange-relaxation-free (SERF) regime. With a vapor cell temperature of $103\text{ }\ifmmode^\circ\else\textdegree\fi{}\text{C}$ we achieve intrinsic magnetic resonance widths $\ensuremath{\Delta}B=17\text{ }\ensuremath{\mu}\text{G}$ corresponding to an electron spin-relaxation rate of $300\text{ }{\text{s}}^{\ensuremath{-}1}$ when the spin-exchange rate is ${\ensuremath{\Gamma}}_{\text{SE}}=14\text{ }000\text{ }{\text{s}}^{\ensuremath{-}1}$. We also observe an interesting narrowing effect due to diffusion. Signal-to-noise measurements yield a sensitivity of about $400\text{ }\text{pG}/\sqrt{\text{Hz}}$. Based on photon shot noise, we project a sensitivity of $40\text{ }\text{pG}/\sqrt{\text{Hz}}$. A theoretical optimization of the magnetometer indicates sensitivities on the order of $2\text{ }\text{pG}/\sqrt{\text{Hz}}$ should be achievable in a $1\text{ }{\text{cm}}^{3}$ volume. Because Cs has a higher saturated vapor pressure than other alkali metals, SERF magnetometers using Cs atoms are particularly attractive in applications requiring lower temperatures.

arXiv:0708.1012•Physical Review A•Mar 13, 2008•400 citations

Accurate determination of alkali atom density based on zero-field magnetic resonance in a single-beam spin-exchange relaxation-free atomic magnetometer

Yintao Ma, Yao Chen, Libo Zhao +6 more

Abstract A single-beam spin-exchange relaxation-free (SERF) atomic magnetometer can extract vector magnetic field information by detecting the transmission intensity of a resonant circularly polarized pumping beam, which depends sensitively on the atomic density of the alkali metal. We present a novel scheme to determine atomic density based on zero-field magnetic resonance. The resonance linewidth under different transverse DC magnetic fields is fitted by means of a quadratic function. The atomic density can be extracted from the quadratic coefficients of the fitted function. The experimental results indicate that the deviation of measured density is less than two times compared with the theoretical values between 378 K and 403 K. Furthermore, the influence of modulation field on resonance linewidth is investigated experimentally and theoretically. A miniature single-beam SERF atomic magnetometer with a sensor head volume of only 16.2 cm 3 and the measuring sensitivity of 40 fT/ Hz 1/2 has been achieved. These results should be beneficial for guiding the development of a chip-scale atomic magnetometer with high sensitivity and spatial resolution for bio-magnetic field imaging applications.

Measurement Science and Technology•May 24, 2022•10 citations

A High Sensitivity Closed-Loop Spin-Exchange Relaxation-Free Atomic Magnetometer With Broad Bandwidth

Qingqian Guo, Tao Hu, Chun-qiao Chen +6 more

Spin-exchange relaxation-free (SERF) atomic magnetometers are the promising non-cryogenic sensors to potentially replace the superconducting quantum interference device (SQUID) in the ultra-weak magnetic-field measurements. Although the SERF magnetometers have achieved a sensitivity of sub-femtotesla, the bandwidth is limited at a narrow range. In this work, we developed a closed-loop SERF magnetometer under proportional-integral (PI) control, the bandwidth could be adaptively tuned and extended above 1.2 kHz. A nearly 40-fold enhancement of the typical bandwidth was achieved in comparison with the open-loop system and the sensitivity was maintained at 15 fT/Hz1/2from 30 Hz to 750 Hz. Moreover, the magnetic field dynamic range could also be greatly improved. This proposed atomic magnetometer with higher bandwidth, sensitivity, and dynamic range has a good prospect in developing a compact, portable, and non-cryogenic magnetic field sensor and may find more applications in biomedical, nuclear magnetic resonance, and fundamental physics research.

IEEE Sensors Journal•Aug 3, 2021•36 citations

Measuring Spin Polarization of a Spin-Exchange Relaxation-Free Atomic Magnetometer at Extremely Large Optical Depths

Yanning Ma, Jixi Lu, Ke Yang +5 more

This paper presents a method for measuring the spin polarization of spin-exchange relaxation-free (SERF) atomic magnetometers at extremely large optical depths. Owing to the slowing-down effect, the spin polarization can be extracted by measuring the slowing-down factor extracted from the precession frequency. However, this technique is limited by a significant error in the regime of extremely large optical depths, where the pump beam intensity for achieving the optimized spin polarization of alkali atoms is significantly increased. We observed that the instantaneous precession frequency measured in the regime where the spin-exchange rate is not much larger than the Larmor frequency was no longer a constant but varied with the pump beam intensity. Thus, a method for measuring spin polarization based on the ratio of the precession frequency to the measured instantaneous precession frequency is proposed. Based on the proposed method, the spin polarization at a temperature of 473K and optical depth of 64 is measured. The measurement results were accordant with theoretical analysis. The expanded uncertainties of the experimental results varied between 1.8% and 9.6%. The proposed method is also applicable to other atomic devices operated in the SERF regime with extremely large optical depths, such as co-magnetometers and atomic spin gyroscopes.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2022•8 citations
Spin-exchange relaxation-free (SERF) atomic magnetometers seem to be the state-of-the-art magnetic sensors today as they have achieved a sensitivity of femtotesla in the elimination of broadening contribution of spin-exchange collisions operated in the mode of SERF regime. In order to extend the practicability of SERF atomic magnetometry in superb performances in a movable platform, ensuring and testing the working status of alkali atoms are of great importance. Given the fact that in the premise of SERF regime, the linewidth of magnetic resonance would be narrowing down and the precession frequency would become a constant fractional value of the Larmor frequency for alkali atoms, we measure the gyromagnetic ratio of weakly polarized alkali-metal vapor by yielding the damped oscillating curves and fitting measured increments of frequency and magnetic field to identify the working regime of alkali atoms in a fast and straightforward manner. The experimental results have good agreements with theoretical analysis and simulation, and the whole measurement process lasts milliseconds with relatively measured error ±1% in the temperature range of T = 156 °C-184 °C. To testify the validity of the innovation, magnetic resonance line is obtained in the same condition proffering the width comparative with the outcome from simulation, indicating the spin-exchange broadening has been eliminated, presenting the same conclusion with innovation, and providing systematic sensitivity 30 fT/Hz1/2.
Spin-exchange-relaxation-free (SERF) atomic magnetometer is the most sensitive magnetic detector in the world at present due to the fact that the broadening of spin-exchange collision is eliminated by operating at high alkali-mental density and low magnetic field. On that condition, the precession frequency of high-density alkali vapor becomes a constant fractional value of Larmor frequency, and the width of magnetic-resonance line gets narrower. This paper analyzes the principle of SERF regime and proposes an innovation based on measuring the slowing-down Larmor frequency directly instead of the complicated conventional method based on the width of magnetic resonance line. We calculated and simulated the slowing-down precession frequency and linewidth of magnetic resonance on certain conditions. The experimental results have verified that the method is valid to identify the regime of SERF of atomic magnetometer via detecting the slowing-down precession frequency.
The spin-exchange relaxation-free (SERF) atomic magnetometer (AM) has vital importance in advanced research and has been widely applied in different fields. To improve the sensitivity and robustness of SERF magnetometers, understanding the relaxation mechanism is a significant approach. By controlling the amplitude and direction of external magnetic fields, and switching statuses of the pump and probe laser beam, we measured both the transverse and longitudinal relaxation rate in two experimental methods, respectively, and obtained the Larmor precession frequency, the spin-exchange relaxation rate, the spin-destruction relaxation rate, and the relaxation rate due to collisions between atoms and vapor cell walls. All experimental results are verified with the theoretical calculations. The final longitudinal relaxation rate of our magnetometer is 53 Hz. Furthermore, we measured the sensitivity of our SERF magnetometer reaching 5 fT/Hz1/2 from 5 to 70 Hz after differential measurement with the 3-dB bandwidth of 70 Hz. Our work helps to improve the detection capability of SERF magnetometers, providing performance assurance for searching for exotic spin-dependent interactions and applications, including magnetoencephalograms and magnetocardiograms.
We describe a Cs atomic magnetometer operating in the spin-exchange-relaxation-free (SERF) regime. With a vapor cell temperature of $103\text{ }\ifmmode^\circ\else\textdegree\fi{}\text{C}$ we achieve intrinsic magnetic resonance widths $\ensuremath{\Delta}B=17\text{ }\ensuremath{\mu}\text{G}$ corresponding to an electron spin-relaxation rate of $300\text{ }{\text{s}}^{\ensuremath{-}1}$ when the spin-exchange rate is ${\ensuremath{\Gamma}}_{\text{SE}}=14\text{ }000\text{ }{\text{s}}^{\ensuremath{-}1}$. We also observe an interesting narrowing effect due to diffusion. Signal-to-noise measurements yield a sensitivity of about 400 pG/Hz400\text{ }\text{pG}/\sqrt{\text{Hz}}400 pG/Hz​. Based on photon shot noise, we project a sensitivity of 40 pG/Hz40\text{ }\text{pG}/\sqrt{\text{Hz}}40 pG/Hz​. A theoretical optimization of the magnetometer indicates sensitivities on the order of 2 pG/Hz2\text{ }\text{pG}/\sqrt{\text{Hz}}2 pG/Hz​ should be achievable in a 1 cm31\text{ }{\text{cm}}^{3}1 cm3 volume. Because Cs has a higher saturated vapor pressure than other alkali metals, SERF magnetometers using Cs atoms are particularly attractive in applications requiring lower temperatures.
Abstract A single-beam spin-exchange relaxation-free (SERF) atomic magnetometer can extract vector magnetic field information by detecting the transmission intensity of a resonant circularly polarized pumping beam, which depends sensitively on the atomic density of the alkali metal. We present a novel scheme to determine atomic density based on zero-field magnetic resonance. The resonance linewidth under different transverse DC magnetic fields is fitted by means of a quadratic function. The atomic density can be extracted from the quadratic coefficients of the fitted function. The experimental results indicate that the deviation of measured density is less than two times compared with the theoretical values between 378 K and 403 K. Furthermore, the influence of modulation field on resonance linewidth is investigated experimentally and theoretically. A miniature single-beam SERF atomic magnetometer with a sensor head volume of only 16.2 cm 3 and the measuring sensitivity of 40 fT/ Hz 1/2 has been achieved. These results should be beneficial for guiding the development of a chip-scale atomic magnetometer with high sensitivity and spatial resolution for bio-magnetic field imaging applications.
Spin-exchange relaxation-free (SERF) atomic magnetometers are the promising non-cryogenic sensors to potentially replace the superconducting quantum interference device (SQUID) in the ultra-weak magnetic-field measurements. Although the SERF magnetometers have achieved a sensitivity of sub-femtotesla, the bandwidth is limited at a narrow range. In this work, we developed a closed-loop SERF magnetometer under proportional-integral (PI) control, the bandwidth could be adaptively tuned and extended above 1.2 kHz. A nearly 40-fold enhancement of the typical bandwidth was achieved in comparison with the open-loop system and the sensitivity was maintained at 15 fT/Hz1/2from 30 Hz to 750 Hz. Moreover, the magnetic field dynamic range could also be greatly improved. This proposed atomic magnetometer with higher bandwidth, sensitivity, and dynamic range has a good prospect in developing a compact, portable, and non-cryogenic magnetic field sensor and may find more applications in biomedical, nuclear magnetic resonance, and fundamental physics research.
This paper presents a method for measuring the spin polarization of spin-exchange relaxation-free (SERF) atomic magnetometers at extremely large optical depths. Owing to the slowing-down effect, the spin polarization can be extracted by measuring the slowing-down factor extracted from the precession frequency. However, this technique is limited by a significant error in the regime of extremely large optical depths, where the pump beam intensity for achieving the optimized spin polarization of alkali atoms is significantly increased. We observed that the instantaneous precession frequency measured in the regime where the spin-exchange rate is not much larger than the Larmor frequency was no longer a constant but varied with the pump beam intensity. Thus, a method for measuring spin polarization based on the ratio of the precession frequency to the measured instantaneous precession frequency is proposed. Based on the proposed method, the spin polarization at a temperature of 473K and optical depth of 64 is measured. The measurement results were accordant with theoretical analysis. The expanded uncertainties of the experimental results varied between 1.8% and 9.6%. The proposed method is also applicable to other atomic devices operated in the SERF regime with extremely large optical depths, such as co-magnetometers and atomic spin gyroscopes.