Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

High-sensitivity cold-atom gyroscope with real-time vibration compensation

Matteo Altorio, Denis Savoie, Bess Fang, Rémi Geiger, Arnaud Landragin

Published Sep 26, 2017• 0 citations
OpenAlex

Abstract

Our cold-atom gyroscope is based on a four-pulse configuration with a very large Sagnac area. Its short-term stability is limited by aliasing effects of the inertial forces (acceleration and rotation). We will show how continuous measurements and real-time compensation of the vibration during the interferometer sequence overcome this limit.

Related papers

High-sensitivity cold-atom gyroscope with real-time vibration compensation

Denis Savoie, Matteo Altorio, Bess Fang +2 more

Our cold-atom gyroscope is based on a four-pulse configuration with a very large Sagnac area. Its short-term stability is limited by aliasing effects of the inertial forces (acceleration and rotation). We will show how continuous measurements and real-time compensation of the vibration during the interferometer sequence overcome this limit.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 1, 2017•0 citations

Limits on the sensitivity of a cold atom interferometry gyroscope

Wenjie Xu, Lele Chen, Ming-Jie Nie +2 more

We present a precision atom interferometry gyroscope with a Sagnac area of 6.0 cm 2 . To drive the cold atom interferometry gyroscope, we utilize two sets of Raman beams with a pulse sequence of π /2- π - π - π /2. We present a procedure for aligning the two sets of Raman beams at the microradian level by making use of the atom interferometer itself in different configurations. Additionally, we measured the atomic cloud trajectory and implemented a spatial symmetry alignment for the atom interferometer. With these improvements, we construct a sensitive atom gyroscope with a stability of 1 nrad/s at an integration time of 10000 s. We analyzed the influence of Raman beams and the limitations of the system, and present the technical limits to the sensitivity and long-term stability. Finally, we point out the primary sources of noise in the atom interferometry gyroscope, clearing the way for the construction of further large-area atom gyroscopes.

Optics Express•Oct 28, 2024•7 citations

Characterization and limits of a cold-atom Sagnac interferometer

A. Gauguet, B. Canuel, Thomas Lévèque +2 more

We present the full evaluation of a cold-atom gyroscope based on atom interferometry. We have performed extensive studies to determine the systematic errors, scale factor and sensitivity. We demonstrate that the acceleration noise can be efficiently removed from the rotation signal, allowing us to reach the fundamental limit of the quantum projection noise for short term measurements. The technical limits to the long term sensitivity and accuracy have been identified, clearing the way for the next generation of ultrasensitive atom gyroscopes.

arXiv:0907.2580•Physical Review A•Dec 1, 2009•201 citations

Continuous cold atom inertial sensor with 1 nrad.s^-1 rotation stability (Conference Presentation)

Rémi Geiger, Indranil Dutta, Denis Savoie +4 more

We report the first operation of a cold atom inertial sensor without dead time. Dead times in conventional cold atom interferometers originate from the preparation of a cold atom source prior to its injection in the interferometer and where information on inertial signals is lost. We use a sequence where we simultaneously prepare a cold atom source and operate a light pulse atom interferometer to circumvent the dead time limitation. Therefore the sensor continuously captures all the dynamics with respect to an inertial frame. We show that the continuous operation does not degrade the sensitivity and stability of the atom interferometer, by demonstrating a rotation sensitivity level of less than 1 nrad/s after 10 000 s of integration time. Such a sensitivity level improves previous results by more than an order of magnitude and opens applications of cold atom gyroscopes in inertial navigation and geophysics.

•Aug 3, 2016•1 citation

Rotation rate measurements with a large area cold atom interferometer

Arnaud Landragin, Matteo Altorio, Romain Gautier +2 more

We present a cold atom gyroscope based on the Sagnac effect for matter-wave with very large area of 11 cm2 with record sensitivity and preliminary study of the scaling factor.

Conference on Lasers and Electro-Optics•Jan 1, 2020•0 citations

Continuous Cold-Atom Inertial Sensor with 1 nrad/sec Rotation Stability

Indranil Dutta, Denis Savoie, Bess Fang +4 more

We report the operation of a cold-atom inertial sensor which continuously captures the rotation signal. Using a joint interrogation scheme, where we simultaneously prepare a cold-atom source and operate an atom interferometer (AI), enables us to eliminate the dead times. We show that such continuous operation improves the short-term sensitivity of AIs, and demonstrate a rotation sensitivity of 100 nrad/sec/sqrt[Hz] in a cold-atom gyroscope of 11 cm^{2} Sagnac area. We also demonstrate a rotation stability of 1 nrad/sec at 10^{4} sec of integration time, which represents the state of the art for atomic gyroscopes. The continuous operation of cold-atom inertial sensors will lead to large area AIs at their full sensitivity potential, determined by the quantum noise limit.

arXiv:1604.00940•Physical Review Letters•May 6, 2016•285 citations
Our cold-atom gyroscope is based on a four-pulse configuration with a very large Sagnac area. Its short-term stability is limited by aliasing effects of the inertial forces (acceleration and rotation). We will show how continuous measurements and real-time compensation of the vibration during the interferometer sequence overcome this limit.
We present a precision atom interferometry gyroscope with a Sagnac area of 6.0 cm 2 . To drive the cold atom interferometry gyroscope, we utilize two sets of Raman beams with a pulse sequence of π /2- π - π - π /2. We present a procedure for aligning the two sets of Raman beams at the microradian level by making use of the atom interferometer itself in different configurations. Additionally, we measured the atomic cloud trajectory and implemented a spatial symmetry alignment for the atom interferometer. With these improvements, we construct a sensitive atom gyroscope with a stability of 1 nrad/s at an integration time of 10000 s. We analyzed the influence of Raman beams and the limitations of the system, and present the technical limits to the sensitivity and long-term stability. Finally, we point out the primary sources of noise in the atom interferometry gyroscope, clearing the way for the construction of further large-area atom gyroscopes.
We present the full evaluation of a cold-atom gyroscope based on atom interferometry. We have performed extensive studies to determine the systematic errors, scale factor and sensitivity. We demonstrate that the acceleration noise can be efficiently removed from the rotation signal, allowing us to reach the fundamental limit of the quantum projection noise for short term measurements. The technical limits to the long term sensitivity and accuracy have been identified, clearing the way for the next generation of ultrasensitive atom gyroscopes.
We report the first operation of a cold atom inertial sensor without dead time. Dead times in conventional cold atom interferometers originate from the preparation of a cold atom source prior to its injection in the interferometer and where information on inertial signals is lost. We use a sequence where we simultaneously prepare a cold atom source and operate a light pulse atom interferometer to circumvent the dead time limitation. Therefore the sensor continuously captures all the dynamics with respect to an inertial frame. We show that the continuous operation does not degrade the sensitivity and stability of the atom interferometer, by demonstrating a rotation sensitivity level of less than 1 nrad/s after 10 000 s of integration time. Such a sensitivity level improves previous results by more than an order of magnitude and opens applications of cold atom gyroscopes in inertial navigation and geophysics.
We report the operation of a cold-atom inertial sensor which continuously captures the rotation signal. Using a joint interrogation scheme, where we simultaneously prepare a cold-atom source and operate an atom interferometer (AI), enables us to eliminate the dead times. We show that such continuous operation improves the short-term sensitivity of AIs, and demonstrate a rotation sensitivity of 100 nrad/sec/sqrt[Hz] in a cold-atom gyroscope of 11 cm^{2} Sagnac area. We also demonstrate a rotation stability of 1 nrad/sec at 10^{4} sec of integration time, which represents the state of the art for atomic gyroscopes. The continuous operation of cold-atom inertial sensors will lead to large area AIs at their full sensitivity potential, determined by the quantum noise limit.