arXiv:1604.00940 · Physical Review Letters

Continuous Cold-Atom Inertial Sensor with 1 nrad/sec Rotation Stability

Indranil Dutta, Denis Savoie, Bess Fang, Bertrand Venon, Carlos L. Garrido Alzar, Rémi Geiger, Arnaud Landragin

Published May 6, 2016• 285 citations
arXivHTMLPDF

Abstract

We report the operation of a cold-atom inertial sensor which continuously captures the rotation signal. Using a joint interrogation scheme, where we simultaneously prepare a cold-atom source and operate an atom interferometer (AI), enables us to eliminate the dead times. We show that such continuous operation improves the short-term sensitivity of AIs, and demonstrate a rotation sensitivity of 100 nrad/sec/sqrt[Hz] in a cold-atom gyroscope of 11 cm^{2} Sagnac area. We also demonstrate a rotation stability of 1 nrad/sec at 10^{4} sec of integration time, which represents the state of the art for atomic gyroscopes. The continuous operation of cold-atom inertial sensors will lead to large area AIs at their full sensitivity potential, determined by the quantum noise limit.

DOI
10.1103/physrevlett.116.183003

Related papers

Cold-atom inertial sensor without deadtime

Bess Fang, Denis Savoie, N. Mielec +5 more

We report the operation of a cold-atom inertial sensor in a joint interrogation scheme, where we simultaneously prepare a cold-atom source and operate an atom interferometer in order to eliminate dead times [1]. This is illustrated in Fig. 1. Dead times and noise aliasing are consequences of the sequential operation which is intrinsic to cold-atom interferometers. Both phenomena have deleterious effects on the performance of these sensors. We show that our continuous operation improves the short-term sensitivity of atom interferometers, by demonstrating a record rotation sensitivity of 100 nrad.s-1/√Hz in a cold-atom gyroscope of 11 cm2Sagnac area. We also demonstrate a rotation stability of 1 nrad.s-1after 104s of integration, improving previous results by an order of magnitude [2-4]. We expect that the continuous operation will allow cold-atom inertial sensors with long interrogation time to reach their full sensitivity, determined by the quantum noise limit.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2017•0 citations

Cold-atom inertial sensor without deadtime

Bess Fang, Indranil Dutta, Denis Savoie +4 more

We report the operation of a cold-atom inertial sensor in a joint interrogation scheme, where we simultaneously prepare a cold-atom source and operate an atom interferometer in order to eliminate dead times. Noise aliasing and dead times are consequences of the sequential operation which is intrinsic to cold-atom atom interferometers. Both phenomena have deleterious effects on the performance of these sensors. We show that our continuous operation improves the short-term sensitivity of atom interferometers, by demonstrating a record rotation sensitivity of 100 nrad.s-1/√(Hz) in a cold-atom gyroscope of 11 cm2Sagnac area. We also demonstrate a rotation stability of 1 nrad.s-1after 104s of integration, improving previous results by an order of magnitude. We expect that the continuous operation will allow cold-atom inertial sensors with long interrogation time to reach their full sensitivity, determined by the quantum noise limit.

arXiv:1605.03869•European Frequency and Time Forum•Apr 1, 2016•5 citations

Continuous cold atom inertial sensor with 1 nrad.s^-1 rotation stability (Conference Presentation)

Rémi Geiger, Indranil Dutta, Denis Savoie +4 more

We report the first operation of a cold atom inertial sensor without dead time. Dead times in conventional cold atom interferometers originate from the preparation of a cold atom source prior to its injection in the interferometer and where information on inertial signals is lost. We use a sequence where we simultaneously prepare a cold atom source and operate a light pulse atom interferometer to circumvent the dead time limitation. Therefore the sensor continuously captures all the dynamics with respect to an inertial frame. We show that the continuous operation does not degrade the sensitivity and stability of the atom interferometer, by demonstrating a rotation sensitivity level of less than 1 nrad/s after 10 000 s of integration time. Such a sensitivity level improves previous results by more than an order of magnitude and opens applications of cold atom gyroscopes in inertial navigation and geophysics.

•Aug 3, 2016•1 citation

Closed-loop dual-atom-interferometer inertial sensor with continuous cold atomic beams

Zhi-Xin Meng, Pei-Qiang Yan, Shengzhe Wang +3 more

We demonstrate a closed-loop light-pulse atom-interferometer inertial sensor that can realize continuous decoupled measurements of acceleration and rotation rate. The sensor operates with double-loop atom interferometers, which share the same Raman light pulses in a spatially separated Mach-Zehnder configuration and use continuous cold atomic beams propagating in opposite directions from two ${\text{2D}}^{+}$ magneto-optical trappings. Acceleration and the rotation rate are decoupled and simultaneously measured by the sum and difference of dual-atom-interferometer signals, respectively. The sensitivities of inertial measurements are also increased to be approximately 1.86 times higher than that of a single atom interferometer. The acceleration phase shift is compensated in real time by phase locking these interferometers via the Raman laser phases from the sum-interferometer signal, and the gyroscope performance is improved. We achieve long-term stabilities of $6.1\phantom{\rule{0.2em}{0ex}}\text{\ensuremath{\mu}}\text{g}$ and 840 nrad/s for the acceleration and the rotation rate, respectively, using a short interrogation time of 0.87 ms (interference area $A=0.097\phantom{\rule{0.2em}{0ex}}{\text{mm}}^{2}$). This work provides a building block for an atomic interferometer-based inertial measurement unit for use in field applications that require a high data rate and high stability.

arXiv:2210.15346•Physical Review Applied•Mar 22, 2024•21 citations

Interleaved atom interferometry for high sensitivity inertial measurements

Matteo Altorio, Romain Gautier, Denis Savoie +3 more

Cold-atom inertial sensors target several applications in navigation, geoscience and tests of fundamental physics. Reaching high sampling rates and high inertial sensitivities, obtained with long interrogation times, represents a challenge for these applications. We report on the interleaved operation of a cold-atom gyroscope, where 3 atomic clouds are interrogated simultaneously in an atom interferometer featuring a 3.75 Hz sampling rate and an interrogation time of 801 ms. Interleaving improves the inertial sensitivity by efficiently averaging vibration noise, and allows us to perform dynamic rotation measurements in a so-far unexplored range. We demonstrate a stability of $3\times 10^{-10}$ rad.s$^{-1}$, which competes with the best stability levels obtained with fiber-optics gyroscopes. Our work validates interleaving as a key concept for future atom-interferometry sensors probing time-varying signals, as in on-board navigation and gravity-gradiometry, searches for dark matter, or gravitational wave detection.

•Apr 8, 2019•72 citations

Interleaved Atom Interferometry for High Sensitivity Inertial Measurements

Denis Savoie, Matteo Altorio, Bess Fang +3 more

We report on interleaved operation of a cold-atom inertial sensor, where three atomic clouds are simultaneously probed in an atom interferometer featuring 4 Hz sampling rate and interrogation time of 801 ms. Interleaving improves the inertial sensitivity by efficiently averaging vibration noise and allows us to perform dynamic rotation measurements in a so far unexplored range. We demonstrate sensitivity of 30 nrad.s-1·Hz-1/2and reach the long-term stability of 3·10-10rads-1, which competes with the best stability levels obtained with fiber-optic gyroscopes. Our work validated interleaving as a key concept for future atom-interferometry sensors probing time-varying signals, as in on-board navigation and gravity gradiometry, searches for dark matter, or gravitational wave detection.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 1, 2019•12 citations
We report the operation of a cold-atom inertial sensor which continuously captures the rotation signal. Using a joint interrogation scheme, where we simultaneously prepare a cold-atom source and operate an atom interferometer (AI), enables us to eliminate the dead times. We show that such continuous operation improves the short-term sensitivity of AIs, and demonstrate a rotation sensitivity of 100 nrad/sec/sqrt[Hz] in a cold-atom gyroscope of 11 cm^{2} Sagnac area. We also demonstrate a rotation stability of 1 nrad/sec at 10^{4} sec of integration time, which represents the state of the art for atomic gyroscopes. The continuous operation of cold-atom inertial sensors will lead to large area AIs at their full sensitivity potential, determined by the quantum noise limit.
We report the operation of a cold-atom inertial sensor in a joint interrogation scheme, where we simultaneously prepare a cold-atom source and operate an atom interferometer in order to eliminate dead times [1]. This is illustrated in Fig. 1. Dead times and noise aliasing are consequences of the sequential operation which is intrinsic to cold-atom interferometers. Both phenomena have deleterious effects on the performance of these sensors. We show that our continuous operation improves the short-term sensitivity of atom interferometers, by demonstrating a record rotation sensitivity of 100 nrad.s-1/√Hz in a cold-atom gyroscope of 11 cm2Sagnac area. We also demonstrate a rotation stability of 1 nrad.s-1after 104s of integration, improving previous results by an order of magnitude [2-4]. We expect that the continuous operation will allow cold-atom inertial sensors with long interrogation time to reach their full sensitivity, determined by the quantum noise limit.
We report the operation of a cold-atom inertial sensor in a joint interrogation scheme, where we simultaneously prepare a cold-atom source and operate an atom interferometer in order to eliminate dead times. Noise aliasing and dead times are consequences of the sequential operation which is intrinsic to cold-atom atom interferometers. Both phenomena have deleterious effects on the performance of these sensors. We show that our continuous operation improves the short-term sensitivity of atom interferometers, by demonstrating a record rotation sensitivity of 100 nrad.s-1/√(Hz) in a cold-atom gyroscope of 11 cm2Sagnac area. We also demonstrate a rotation stability of 1 nrad.s-1after 104s of integration, improving previous results by an order of magnitude. We expect that the continuous operation will allow cold-atom inertial sensors with long interrogation time to reach their full sensitivity, determined by the quantum noise limit.
We report the first operation of a cold atom inertial sensor without dead time. Dead times in conventional cold atom interferometers originate from the preparation of a cold atom source prior to its injection in the interferometer and where information on inertial signals is lost. We use a sequence where we simultaneously prepare a cold atom source and operate a light pulse atom interferometer to circumvent the dead time limitation. Therefore the sensor continuously captures all the dynamics with respect to an inertial frame. We show that the continuous operation does not degrade the sensitivity and stability of the atom interferometer, by demonstrating a rotation sensitivity level of less than 1 nrad/s after 10 000 s of integration time. Such a sensitivity level improves previous results by more than an order of magnitude and opens applications of cold atom gyroscopes in inertial navigation and geophysics.
We demonstrate a closed-loop light-pulse atom-interferometer inertial sensor that can realize continuous decoupled measurements of acceleration and rotation rate. The sensor operates with double-loop atom interferometers, which share the same Raman light pulses in a spatially separated Mach-Zehnder configuration and use continuous cold atomic beams propagating in opposite directions from two 2D+{\text{2D}}^{+}2D+ magneto-optical trappings. Acceleration and the rotation rate are decoupled and simultaneously measured by the sum and difference of dual-atom-interferometer signals, respectively. The sensitivities of inertial measurements are also increased to be approximately 1.86 times higher than that of a single atom interferometer. The acceleration phase shift is compensated in real time by phase locking these interferometers via the Raman laser phases from the sum-interferometer signal, and the gyroscope performance is improved. We achieve long-term stabilities of $6.1\phantom{\rule{0.2em}{0ex}}\text{\ensuremath{\mu}}\text{g}$ and 840 nrad/s for the acceleration and the rotation rate, respectively, using a short interrogation time of 0.87 ms (interference area A=0.097mm2A=0.097\phantom{\rule{0.2em}{0ex}}{\text{mm}}^{2}A=0.097mm2). This work provides a building block for an atomic interferometer-based inertial measurement unit for use in field applications that require a high data rate and high stability.
Cold-atom inertial sensors target several applications in navigation, geoscience and tests of fundamental physics. Reaching high sampling rates and high inertial sensitivities, obtained with long interrogation times, represents a challenge for these applications. We report on the interleaved operation of a cold-atom gyroscope, where 3 atomic clouds are interrogated simultaneously in an atom interferometer featuring a 3.75 Hz sampling rate and an interrogation time of 801 ms. Interleaving improves the inertial sensitivity by efficiently averaging vibration noise, and allows us to perform dynamic rotation measurements in a so-far unexplored range. We demonstrate a stability of 3×10−103\times 10^{-10}3×10−10 rad.s−1^{-1}−1, which competes with the best stability levels obtained with fiber-optics gyroscopes. Our work validates interleaving as a key concept for future atom-interferometry sensors probing time-varying signals, as in on-board navigation and gravity-gradiometry, searches for dark matter, or gravitational wave detection.
We report on interleaved operation of a cold-atom inertial sensor, where three atomic clouds are simultaneously probed in an atom interferometer featuring 4 Hz sampling rate and interrogation time of 801 ms. Interleaving improves the inertial sensitivity by efficiently averaging vibration noise and allows us to perform dynamic rotation measurements in a so far unexplored range. We demonstrate sensitivity of 30 nrad.s-1·Hz-1/2and reach the long-term stability of 3·10-10rads-1, which competes with the best stability levels obtained with fiber-optic gyroscopes. Our work validated interleaving as a key concept for future atom-interferometry sensors probing time-varying signals, as in on-board navigation and gravity gradiometry, searches for dark matter, or gravitational wave detection.