Emerging Imaging and Sensing Technologies for Security and Defence; and Advanced Manufacturing Technologies for Micro- and Nanosystems in Security and Defence

Loss-tolerant interferometry with squeezed light

Maria V. Chekhova, Gaetano Frascella, Sascha Agne, Farid Ya Khalili

Published Sep 18, 2020• 0 citations
Publisher

Abstract

An important part of optical sensing is interferometry, where direct or homodyne detection at the output of an interferometer yields information about small phase shifts. Classical interferometry operates at the shot-noise limit (SNL), caused by the photon structure of light and reached when an interferometer is fed with coherent light. The use of nonclassical light at the input of an interferometer enables overcoming the SNL. In particular, squeezed light is known to be less noisy than coherent light. An interferometer fed with strongly squeezed light can, in principle, provide the phase sensitivity at the Heisenberg limit, the ultimate limit allowed by the laws of physics. However, this supersensitive operation is strongly degraded by loss – both inside the interferometer and outside it, at the stage of detection. While the former (internal loss) seems to be inevitable, the latter (detection loss) can be overcome, and we demonstrate it in our recent experiment. The clue is to amplify light at the interferometer output using a phase-sensitive optical parametric amplifier. This device does not introduce additional noise, but it amplifies the fragile quantum signal and thus makes it tolerant to loss at the detection stage. In a proof-of-principle experiment, we build a polarization Mach-Zehnder interferometer and feed it with coherent light in one port and a squeezed vacuum in another port. At one output port, we amplify light with an optical parametric amplifier and measure a phase sensitivity of 13 mrad for 1500 photons in the interferometer. This result, achieved with 50% detection efficiency, overcomes the SNL by 3 dB. Moreover, by using stronger amplification, we can overcome the SNL under detection efficiency as low as 13%. Our results outline a way to use squeezed light for real-life sensing, where the detection efficiency cannot be very high, especially in spectral ranges like middle-infrared or terahertz.

DOI
10.1117/12.2574780

Related papers

Overcoming detection loss and noise in squeezing-based optical sensing

Gaetano Frascella, Sascha Agne, Farid Ya. Khalili +1 more

Among the known resources of quantum metrology, one of the most practical and efficient is squeezing. Squeezed states of atoms and light improve the sensing of the phase, magnetic field, polarization, mechanical displacement. They promise to considerably increase signal-to-noise ratio in imaging and spectroscopy, and are already used in real-life gravitational-wave detectors. But despite being more robust than other states, they are still very fragile, which narrows the scope of their application. In particular, squeezed states are useless in measurements where the detection is inefficient or the noise is high. Here, we experimentally demonstrate a remedy against loss and noise: strong noiseless amplification before detection. This way, we achieve loss-tolerant operation of an interferometer fed with squeezed and coherent light. With only 50% detection efficiency and with noise exceeding the level of squeezed light more than 50 times, we overcome the shot-noise limit by 6 dB. Sub-shot-noise phase sensitivity survives up to 87% loss. Application of this technique to other types of optical sensing and imaging promises a full use of quantum resources in these fields.

arXiv:2005.08843•npj Quantum Information•May 12, 2021•98 citations

Overcoming detection losses in a supersensitive interferometer with coherent and squeezed vacuum inputs

Gaetano Frascella, Sascha Agne, Farid Ya Khalili +1 more

We report phase sensitivity overcoming the shot-noise limit by 3 dB for a squeezing-assisted interferometer with 50% detection losses. The performance is tolerant to losses up to 87% because of an optical parametric amplifier at the output.

Conference on Lasers and Electro-Optics•Jan 1, 2020•1 citation

Detection Loss Tolerant Supersensitive Phase Measurement with an SU(1,1) Interferometer

Mathieu Manceau, Gerd Leuchs, Farid Ya Khalili +1 more

In an unseeded SU(1,1) interferometer composed of two cascaded degenerate parametric amplifiers, with direct detection at the output, we demonstrate a phase sensitivity overcoming the shot noise limit by 2.3 dB. The interferometer is strongly unbalanced, with the parametric gain of the second amplifier exceeding the gain of the first one by a factor of 2, which makes the scheme extremely tolerant to detection losses. We show that by increasing the gain of the second amplifier, the phase supersensitivity of the interferometer can be preserved even with detection losses as high as 80%. This finding can considerably improve the state-of-the-art interferometry, enable sub-shot-noise phase sensitivity in spectral ranges with inefficient detection, and allow extension to quantum imaging.

arXiv:1705.02662•Physical Review Letters•Nov 29, 2017•202 citations

Precision measurement beyond the shot-noise limit

Min Xiao, Ling-An Wu, H. J. Kimble

Improvements in precision beyond the limit set by the vacuum state or zero-point fluctuations of the field are reported for two optical experiments. Both experiments employ the squeezed light from an optical parametric oscillator to reduce the level of fluctuations in one of two quadrature phase amplitudes below the shot-noise level (SNL). The first experiment follows the work of Caves1 on precision interferometry with squeezed states. An increase in signal-to-noise of 2.5 dB relative to the SNL is demonstrated for the detection of phase modulation in a Mach-Zehnder interferometer. In the second experiment amplitude modulation is encoded on a weak signal beam with an acoustooptic modulator. For the case of a squeezed signal beam compared with a beam in a coherent state, an improvement in sensitivity of 2.5 dB is achieved for the detection of amplitude changes of the field. The observed increases in sensitivity in both experiments are currently limited by simple linear losses in propagation and detection and not by the degree of available squeezing.

Annual Meeting Optical Society of America•Jan 1, 1987•3 citations

The phase sensitivity of an SU(1,1) interferometer with coherent and squeezed-vacuum light

Dong Li, Chun-Hua Yuan, Z. Y. Ou +1 more

We theoretically study the phase sensitivity of an SU(1,1) interferometer with a coherent state in one input port and a squeezed-vacuum state in the other input port using the method of homodyne detection. In this interferometer, beam splitting and recombination are generated by the parametric amplifiers instead of the beam splitters. Compared with the traditional Mach–Zehnder interferometer, the phase sensitivity of this interferometer can be improved due to the amplification process of the parametric amplifiers. Combined with the squeezed state input, the sensitivity can be improved further due to the noise reduction. The phase sensitivity of our scheme can approach the Heisenberg limit and the associated optimal condition is analyzed. The scheme can be implemented with current experimental technology.

arXiv:1305.4769•New Journal of Physics•Jul 17, 2014•135 citations

Loss-tolerant and quantum-enhanced interferometer by reversed squeezing processes

Long Tian, Wenxiu Yao, Yimiao Wu +4 more

Reversed nonlinear dynamics is predicted to be capable of enhancing the quantum sensing in unprecedented ways. Here, we report the experimental demonstration of a loss-tolerant (external loss) and quantum-enhanced interferometer. Two cascaded optical parametric amplifiers are used to judiciously construct an interferometry with two orthogonal squeezing operation. As a consequence, a weak displacement introduced by a test cavity can be amplified for measurement, and the measured signal-to-noise ratio is better than that of both conventional photon shot-noise limited and squeezed-light assisted interferometers. We further confirm its superior loss-tolerant performance by varying the external losses and comparing with both conventional photon shot-noise limited and squeezed-light assisted configurations, illustrating the potential application in gravitational wave detection.

Optics Letters•Jul 20, 2023•10 citations
An important part of optical sensing is interferometry, where direct or homodyne detection at the output of an interferometer yields information about small phase shifts. Classical interferometry operates at the shot-noise limit (SNL), caused by the photon structure of light and reached when an interferometer is fed with coherent light. The use of nonclassical light at the input of an interferometer enables overcoming the SNL. In particular, squeezed light is known to be less noisy than coherent light. An interferometer fed with strongly squeezed light can, in principle, provide the phase sensitivity at the Heisenberg limit, the ultimate limit allowed by the laws of physics. However, this supersensitive operation is strongly degraded by loss – both inside the interferometer and outside it, at the stage of detection. While the former (internal loss) seems to be inevitable, the latter (detection loss) can be overcome, and we demonstrate it in our recent experiment. The clue is to amplify light at the interferometer output using a phase-sensitive optical parametric amplifier. This device does not introduce additional noise, but it amplifies the fragile quantum signal and thus makes it tolerant to loss at the detection stage. In a proof-of-principle experiment, we build a polarization Mach-Zehnder interferometer and feed it with coherent light in one port and a squeezed vacuum in another port. At one output port, we amplify light with an optical parametric amplifier and measure a phase sensitivity of 13 mrad for 1500 photons in the interferometer. This result, achieved with 50% detection efficiency, overcomes the SNL by 3 dB. Moreover, by using stronger amplification, we can overcome the SNL under detection efficiency as low as 13%. Our results outline a way to use squeezed light for real-life sensing, where the detection efficiency cannot be very high, especially in spectral ranges like middle-infrared or terahertz.
Among the known resources of quantum metrology, one of the most practical and efficient is squeezing. Squeezed states of atoms and light improve the sensing of the phase, magnetic field, polarization, mechanical displacement. They promise to considerably increase signal-to-noise ratio in imaging and spectroscopy, and are already used in real-life gravitational-wave detectors. But despite being more robust than other states, they are still very fragile, which narrows the scope of their application. In particular, squeezed states are useless in measurements where the detection is inefficient or the noise is high. Here, we experimentally demonstrate a remedy against loss and noise: strong noiseless amplification before detection. This way, we achieve loss-tolerant operation of an interferometer fed with squeezed and coherent light. With only 50% detection efficiency and with noise exceeding the level of squeezed light more than 50 times, we overcome the shot-noise limit by 6 dB. Sub-shot-noise phase sensitivity survives up to 87% loss. Application of this technique to other types of optical sensing and imaging promises a full use of quantum resources in these fields.
In an unseeded SU(1,1) interferometer composed of two cascaded degenerate parametric amplifiers, with direct detection at the output, we demonstrate a phase sensitivity overcoming the shot noise limit by 2.3 dB. The interferometer is strongly unbalanced, with the parametric gain of the second amplifier exceeding the gain of the first one by a factor of 2, which makes the scheme extremely tolerant to detection losses. We show that by increasing the gain of the second amplifier, the phase supersensitivity of the interferometer can be preserved even with detection losses as high as 80%. This finding can considerably improve the state-of-the-art interferometry, enable sub-shot-noise phase sensitivity in spectral ranges with inefficient detection, and allow extension to quantum imaging.
Improvements in precision beyond the limit set by the vacuum state or zero-point fluctuations of the field are reported for two optical experiments. Both experiments employ the squeezed light from an optical parametric oscillator to reduce the level of fluctuations in one of two quadrature phase amplitudes below the shot-noise level (SNL). The first experiment follows the work of Caves1 on precision interferometry with squeezed states. An increase in signal-to-noise of 2.5 dB relative to the SNL is demonstrated for the detection of phase modulation in a Mach-Zehnder interferometer. In the second experiment amplitude modulation is encoded on a weak signal beam with an acoustooptic modulator. For the case of a squeezed signal beam compared with a beam in a coherent state, an improvement in sensitivity of 2.5 dB is achieved for the detection of amplitude changes of the field. The observed increases in sensitivity in both experiments are currently limited by simple linear losses in propagation and detection and not by the degree of available squeezing.
We theoretically study the phase sensitivity of an SU(1,1) interferometer with a coherent state in one input port and a squeezed-vacuum state in the other input port using the method of homodyne detection. In this interferometer, beam splitting and recombination are generated by the parametric amplifiers instead of the beam splitters. Compared with the traditional Mach–Zehnder interferometer, the phase sensitivity of this interferometer can be improved due to the amplification process of the parametric amplifiers. Combined with the squeezed state input, the sensitivity can be improved further due to the noise reduction. The phase sensitivity of our scheme can approach the Heisenberg limit and the associated optimal condition is analyzed. The scheme can be implemented with current experimental technology.
Reversed nonlinear dynamics is predicted to be capable of enhancing the quantum sensing in unprecedented ways. Here, we report the experimental demonstration of a loss-tolerant (external loss) and quantum-enhanced interferometer. Two cascaded optical parametric amplifiers are used to judiciously construct an interferometry with two orthogonal squeezing operation. As a consequence, a weak displacement introduced by a test cavity can be amplified for measurement, and the measured signal-to-noise ratio is better than that of both conventional photon shot-noise limited and squeezed-light assisted interferometers. We further confirm its superior loss-tolerant performance by varying the external losses and comparing with both conventional photon shot-noise limited and squeezed-light assisted configurations, illustrating the potential application in gravitational wave detection.