Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Annual Meeting Optical Society of America

Precision measurement beyond the shot-noise limit

Min Xiao, Ling-An Wu, H. J. Kimble

Published Jan 1, 1987• 3 citations
Publisher

Abstract

Improvements in precision beyond the limit set by the vacuum state or zero-point fluctuations of the field are reported for two optical experiments. Both experiments employ the squeezed light from an optical parametric oscillator to reduce the level of fluctuations in one of two quadrature phase amplitudes below the shot-noise level (SNL). The first experiment follows the work of Caves1 on precision interferometry with squeezed states. An increase in signal-to-noise of 2.5 dB relative to the SNL is demonstrated for the detection of phase modulation in a Mach-Zehnder interferometer. In the second experiment amplitude modulation is encoded on a weak signal beam with an acoustooptic modulator. For the case of a squeezed signal beam compared with a beam in a coherent state, an improvement in sensitivity of 2.5 dB is achieved for the detection of amplitude changes of the field. The observed increases in sensitivity in both experiments are currently limited by simple linear losses in propagation and detection and not by the degree of available squeezing.

DOI
10.1364/oam.1987.me2

Related papers

Precision measurement beyond the shot-noise limit

Min Xiao, Ling-An Wu, Harry J. Kimble

An improvement in precision beyond the limit set by the vacuum-state or zero-point fluctuations of the electromagnetic field is reported for the measurement of phase modulation in an optical interferometer. The experiment makes use of squeezed light to reduce the level of fluctuations below the shot-noise limit. An increase in the signal-to-noise ratio of 3.0 dB relative to the shot-noise limit is demonstrated, with the improvement currently limited by losses in propagation and detection and not by the degree of available squeezing.

Physical Review Letters•Jul 20, 1987•728 citations

Detection of amplitude modulation with squeezed light for sensitivity beyond the shot-noise limit

Min Xiao, Ling-An Wu, Harry J. Kimble

An improvement in precision beyond the limit set by the vacuum-state or zero-point fluctuations of the electromagnetic field is reported for the detection of amplitude modulation encoded on a weak signal beam. The improvement is achieved by employing the squeezed light from an optical parametric oscillator to reduce the level of fluctuations below the shot-noise limit. An increase in signal-to-noise ratio of 2.5 dB relative to the shot-noise limit is demonstrated.

Optics Letters•Jun 1, 1988•63 citations

Squeezed states of light

Harry J. Kimble

Squeezed states of the electromagnetic field are characterized by a reduction of fluctuations for one of two quadrature phase amplitudes below the level of fluctuations for the vacuum state. This reduction is a manifestly quantum or nonclassical feature which is of great interest in its own right but also potentially important for precision measurement with sensitivity beyond the shot-noise or vacuum-state limit. We describe three different experiments in which squeezed light has been generated in our laboratory involving parametric downconversion, intracavity frequency doubling, and optical bistability with two-state atoms. By employing the squeezed light produced by a subthreshold optical parametric oscillator, we have achieved improvements in sensitivity beyond the vacuum-state limit for the detection of both phase and amplitude changes of the electromagnetic field. An alternate route to sensitivity beyond the vacuum-state limit is through quantum nondemolition measurement, where we have suggested and are implementing a scheme involving parametric conversion and polarization mixing.

Annual Meeting Optical Society of America•Jan 1, 1988•0 citations

Quantum-enhanced optical precision measurement assisted by low-frequency squeezed vacuum states

Guohui 国辉 Kang 康, Jinxia 晋霞 Feng 冯, Lin 琳 Cheng 程 +2 more

Stable low-frequency squeezed vacuum states at a wavelength of 1550 nm were generated. By controlling the squeezing angle of the squeezed vacuum states, two types of low-frequency quadrature-phase squeezed vacuum states and quadrature-amplitude squeezed vacuum states were obtained using one setup respectively. A quantum-enhanced fiber Mach–Zehnder interferometer (FMZI) was demonstrated for low-frequency phase measurement using the generated quadrature-phase squeezed vacuum states that were injected. When phase modulation was measured with the quantum-enhanced FMZI, there were above 3 dB quantum improvements beyond the shot-noise limit (SNL) from 40 kHz to 200 kHz, and 2.3 dB quantum improvement beyond the SNL at 20 kHz was obtained. The generated quadrature-amplitude squeezed vacuum state was applied to perform low-frequency amplitude modulation measurement for sensitivity beyond the SNL based on optical fiber construction. There were about 2 dB quantum improvements beyond the SNL from 60 kHz to 200 kHz. The current scheme proves that quantum-enhanced fiber-based sensors are feasible and have potential applications in high-precision measurements based on fiber, particularly in the low-frequency range.

Chinese Physics B•Mar 17, 2023•4 citations

Loss-tolerant interferometry with squeezed light

Maria V. Chekhova, Gaetano Frascella, Sascha Agne +1 more

An important part of optical sensing is interferometry, where direct or homodyne detection at the output of an interferometer yields information about small phase shifts. Classical interferometry operates at the shot-noise limit (SNL), caused by the photon structure of light and reached when an interferometer is fed with coherent light. The use of nonclassical light at the input of an interferometer enables overcoming the SNL. In particular, squeezed light is known to be less noisy than coherent light. An interferometer fed with strongly squeezed light can, in principle, provide the phase sensitivity at the Heisenberg limit, the ultimate limit allowed by the laws of physics. However, this supersensitive operation is strongly degraded by loss – both inside the interferometer and outside it, at the stage of detection. While the former (internal loss) seems to be inevitable, the latter (detection loss) can be overcome, and we demonstrate it in our recent experiment. The clue is to amplify light at the interferometer output using a phase-sensitive optical parametric amplifier. This device does not introduce additional noise, but it amplifies the fragile quantum signal and thus makes it tolerant to loss at the detection stage. In a proof-of-principle experiment, we build a polarization Mach-Zehnder interferometer and feed it with coherent light in one port and a squeezed vacuum in another port. At one output port, we amplify light with an optical parametric amplifier and measure a phase sensitivity of 13 mrad for 1500 photons in the interferometer. This result, achieved with 50% detection efficiency, overcomes the SNL by 3 dB. Moreover, by using stronger amplification, we can overcome the SNL under detection efficiency as low as 13%. Our results outline a way to use squeezed light for real-life sensing, where the detection efficiency cannot be very high, especially in spectral ranges like middle-infrared or terahertz.

Emerging Imaging and Sensing Technologies for Security and Defence; and Advanced Manufacturing Technologies for Micro- and Nanosystems in Security and Defence•Sep 18, 2020•0 citations

Sub-Shot Noise Interferometry and Quantum Imaging

Richard E. Slusher, Arthur La Porta, Philippe Grangier +2 more

Optimizing the sensitivity for interferometric measurement of optical phase involves maximizing the intensity of the illuminating light source and minimizing any noise sources. Limits to the light source intensity may arise from the availability of a stable high-power laser or from damage to the system being measured. For example, we describe here a scanning confocal polarization microscope designed to image the dynamics of nerve networks. In this case the light intensity limit is set by several factors, including the scanning rate, the required response time and damage limits of the biological system. Assuming a stable experimental configuration for the interferometer and light source, the limiting noise source for visible light interferometry is shot-noise associated with the quantum state of the light inputs to the interferometer. Shot-noise can be thought of as arising from vacuum fluctuations entering the dark input port of the interferometer.(1) These vacuum field fluctuations combine with the light entering the other port to cause shot-noise in the detected photocurrent at the output ports of the interferometer. This shot-noise current normally limits the measured phase variance Δϕ to a value of 1/N where N is the average number of photons detected in a measurement interval. We describe an experiment which demonstrates that this shot-noise limit can be improved by injecting squeezed vacuum into the normally dark input port.(2) In this case the phase variance is reduced below the 1/N limit by the degree of squeezing. In contrast to early experiments,(2) we are now operating the interferometer in a dark fringe mode(3–5) in order to avoid setting a limit to the light level caused by detector saturation (near 1 mW).

Topical Meeting on Quantum-Limited Imaging and Image Processing•Jan 1, 1989•0 citations
Improvements in precision beyond the limit set by the vacuum state or zero-point fluctuations of the field are reported for two optical experiments. Both experiments employ the squeezed light from an optical parametric oscillator to reduce the level of fluctuations in one of two quadrature phase amplitudes below the shot-noise level (SNL). The first experiment follows the work of Caves1 on precision interferometry with squeezed states. An increase in signal-to-noise of 2.5 dB relative to the SNL is demonstrated for the detection of phase modulation in a Mach-Zehnder interferometer. In the second experiment amplitude modulation is encoded on a weak signal beam with an acoustooptic modulator. For the case of a squeezed signal beam compared with a beam in a coherent state, an improvement in sensitivity of 2.5 dB is achieved for the detection of amplitude changes of the field. The observed increases in sensitivity in both experiments are currently limited by simple linear losses in propagation and detection and not by the degree of available squeezing.
An improvement in precision beyond the limit set by the vacuum-state or zero-point fluctuations of the electromagnetic field is reported for the measurement of phase modulation in an optical interferometer. The experiment makes use of squeezed light to reduce the level of fluctuations below the shot-noise limit. An increase in the signal-to-noise ratio of 3.0 dB relative to the shot-noise limit is demonstrated, with the improvement currently limited by losses in propagation and detection and not by the degree of available squeezing.
Squeezed states of the electromagnetic field are characterized by a reduction of fluctuations for one of two quadrature phase amplitudes below the level of fluctuations for the vacuum state. This reduction is a manifestly quantum or nonclassical feature which is of great interest in its own right but also potentially important for precision measurement with sensitivity beyond the shot-noise or vacuum-state limit. We describe three different experiments in which squeezed light has been generated in our laboratory involving parametric downconversion, intracavity frequency doubling, and optical bistability with two-state atoms. By employing the squeezed light produced by a subthreshold optical parametric oscillator, we have achieved improvements in sensitivity beyond the vacuum-state limit for the detection of both phase and amplitude changes of the electromagnetic field. An alternate route to sensitivity beyond the vacuum-state limit is through quantum nondemolition measurement, where we have suggested and are implementing a scheme involving parametric conversion and polarization mixing.
Stable low-frequency squeezed vacuum states at a wavelength of 1550 nm were generated. By controlling the squeezing angle of the squeezed vacuum states, two types of low-frequency quadrature-phase squeezed vacuum states and quadrature-amplitude squeezed vacuum states were obtained using one setup respectively. A quantum-enhanced fiber Mach–Zehnder interferometer (FMZI) was demonstrated for low-frequency phase measurement using the generated quadrature-phase squeezed vacuum states that were injected. When phase modulation was measured with the quantum-enhanced FMZI, there were above 3 dB quantum improvements beyond the shot-noise limit (SNL) from 40 kHz to 200 kHz, and 2.3 dB quantum improvement beyond the SNL at 20 kHz was obtained. The generated quadrature-amplitude squeezed vacuum state was applied to perform low-frequency amplitude modulation measurement for sensitivity beyond the SNL based on optical fiber construction. There were about 2 dB quantum improvements beyond the SNL from 60 kHz to 200 kHz. The current scheme proves that quantum-enhanced fiber-based sensors are feasible and have potential applications in high-precision measurements based on fiber, particularly in the low-frequency range.
An important part of optical sensing is interferometry, where direct or homodyne detection at the output of an interferometer yields information about small phase shifts. Classical interferometry operates at the shot-noise limit (SNL), caused by the photon structure of light and reached when an interferometer is fed with coherent light. The use of nonclassical light at the input of an interferometer enables overcoming the SNL. In particular, squeezed light is known to be less noisy than coherent light. An interferometer fed with strongly squeezed light can, in principle, provide the phase sensitivity at the Heisenberg limit, the ultimate limit allowed by the laws of physics. However, this supersensitive operation is strongly degraded by loss – both inside the interferometer and outside it, at the stage of detection. While the former (internal loss) seems to be inevitable, the latter (detection loss) can be overcome, and we demonstrate it in our recent experiment. The clue is to amplify light at the interferometer output using a phase-sensitive optical parametric amplifier. This device does not introduce additional noise, but it amplifies the fragile quantum signal and thus makes it tolerant to loss at the detection stage. In a proof-of-principle experiment, we build a polarization Mach-Zehnder interferometer and feed it with coherent light in one port and a squeezed vacuum in another port. At one output port, we amplify light with an optical parametric amplifier and measure a phase sensitivity of 13 mrad for 1500 photons in the interferometer. This result, achieved with 50% detection efficiency, overcomes the SNL by 3 dB. Moreover, by using stronger amplification, we can overcome the SNL under detection efficiency as low as 13%. Our results outline a way to use squeezed light for real-life sensing, where the detection efficiency cannot be very high, especially in spectral ranges like middle-infrared or terahertz.
Optimizing the sensitivity for interferometric measurement of optical phase involves maximizing the intensity of the illuminating light source and minimizing any noise sources. Limits to the light source intensity may arise from the availability of a stable high-power laser or from damage to the system being measured. For example, we describe here a scanning confocal polarization microscope designed to image the dynamics of nerve networks. In this case the light intensity limit is set by several factors, including the scanning rate, the required response time and damage limits of the biological system. Assuming a stable experimental configuration for the interferometer and light source, the limiting noise source for visible light interferometry is shot-noise associated with the quantum state of the light inputs to the interferometer. Shot-noise can be thought of as arising from vacuum fluctuations entering the dark input port of the interferometer.(1) These vacuum field fluctuations combine with the light entering the other port to cause shot-noise in the detected photocurrent at the output ports of the interferometer. This shot-noise current normally limits the measured phase variance Δϕ to a value of 1/N where N is the average number of photons detected in a measurement interval. We describe an experiment which demonstrates that this shot-noise limit can be improved by injecting squeezed vacuum into the normally dark input port.(2) In this case the phase variance is reduced below the 1/N limit by the degree of squeezing. In contrast to early experiments,(2) we are now operating the interferometer in a dark fringe mode(3–5) in order to avoid setting a limit to the light level caused by detector saturation (near 1 mW).