Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Topical Meeting on Quantum-Limited Imaging and Image Processing

Sub-Shot Noise Interferometry and Quantum Imaging

Richard E. Slusher, Arthur La Porta, Philippe Grangier, R. Stepnoski, D. Kleinfeld

Published Jan 1, 1989• 0 citations
Publisher

Abstract

Optimizing the sensitivity for interferometric measurement of optical phase involves maximizing the intensity of the illuminating light source and minimizing any noise sources. Limits to the light source intensity may arise from the availability of a stable high-power laser or from damage to the system being measured. For example, we describe here a scanning confocal polarization microscope designed to image the dynamics of nerve networks. In this case the light intensity limit is set by several factors, including the scanning rate, the required response time and damage limits of the biological system. Assuming a stable experimental configuration for the interferometer and light source, the limiting noise source for visible light interferometry is shot-noise associated with the quantum state of the light inputs to the interferometer. Shot-noise can be thought of as arising from vacuum fluctuations entering the dark input port of the interferometer.(1) These vacuum field fluctuations combine with the light entering the other port to cause shot-noise in the detected photocurrent at the output ports of the interferometer. This shot-noise current normally limits the measured phase variance Δϕ to a value of 1/N where N is the average number of photons detected in a measurement interval. We describe an experiment which demonstrates that this shot-noise limit can be improved by injecting squeezed vacuum into the normally dark input port.(2) In this case the phase variance is reduced below the 1/N limit by the degree of squeezing. In contrast to early experiments,(2) we are now operating the interferometer in a dark fringe mode(3–5) in order to avoid setting a limit to the light level caused by detector saturation (near 1 mW).

DOI
10.1364/qlip.1989.mb2

Related papers

Squeezed vacuum enhanced interferometry at the dark fringe

P. Granger, Richard E. Slusher, Arthur LaPorta

An experimental study of enhancement of interferometric sensitivity using squeezed vacuum fluctuations is described. By operating an interferometer at the dark fringe, large laser powers can be used for high sensitivity. It is possible to enhance the interferometric sensitivity beyond the shot-noise limit in the dark fringe arrangement by using an electrooptic modulator in the interferometer to vary the phase periodically away from the dark fringe. A detector at the dark output port can then operate at the shot-noise limit and detect phase imbalance at the sensitivity determined by power level at the bright output port.1 This shot-noise limit can be reduced further by illuminating the dark input port with squeezed vacuum, as demonstrated recently in balanced output port experiments.2,3 However, there are interesting limits to the sensitivity improvement expected in the dark fringe case.1 The experimental arrangement includes a polarization interferometer illuminated with 100 mW of 1.064-μm wavelength light from a Nd:YAG cw laser. Squeezed vacuum is generated by a KTP optical parametric amplifier. Experimental progress is reported at sensitivities in the nanoradian polarization rotation range.

Annual Meeting Optical Society of America•Jan 1, 1988•0 citations

Subhertz interferometry at the quantum noise limit

Peng Yang, Boya Xie, Sheng Feng

Quantum noise limited interferometry for subhertz phase measurement is of essence in precision metrology applications, such as gravitational wave detection. However, suppression of subhertz classical noises below the shot-noise level is very challenging in practice. Two-frequency interferometry has been previously proposed to avoid low-frequency noises and may be useful for squeezing-enhanced high-precision phase measurement. Here we experimentally demonstrate a subhertz interferometer at the standard quantum noise (shot-noise) limit, by use of dual-frequency coherent probe light at the input and phase-sensitive heterodyne detection to measure the output interfered light. When the interferometer is locked at a dark fringe, the noise floor of the phase variance in the interferometer reaches the shot-noise level down to Fourier frequencies below 1 Hz. This work should pave a way for a realization of subhertz interferometry beyond the shot-noise limit.

Optics Letters•Apr 30, 2019•13 citations

Precision measurement beyond the shot-noise limit

Min Xiao, Ling-An Wu, H. J. Kimble

Improvements in precision beyond the limit set by the vacuum state or zero-point fluctuations of the field are reported for two optical experiments. Both experiments employ the squeezed light from an optical parametric oscillator to reduce the level of fluctuations in one of two quadrature phase amplitudes below the shot-noise level (SNL). The first experiment follows the work of Caves1 on precision interferometry with squeezed states. An increase in signal-to-noise of 2.5 dB relative to the SNL is demonstrated for the detection of phase modulation in a Mach-Zehnder interferometer. In the second experiment amplitude modulation is encoded on a weak signal beam with an acoustooptic modulator. For the case of a squeezed signal beam compared with a beam in a coherent state, an improvement in sensitivity of 2.5 dB is achieved for the detection of amplitude changes of the field. The observed increases in sensitivity in both experiments are currently limited by simple linear losses in propagation and detection and not by the degree of available squeezing.

Annual Meeting Optical Society of America•Jan 1, 1987•3 citations

Spectroscopy squeezed beyond the shot-noise limit

Philippe Grangier

For many years the "shot-noise limit" has been considered as the fundamental limitation on measurements made with light beams. Shot noise is due to the quantum nature of light: the number of photons detected in a given time from a "stable" light beam (for instance, a laser beam) is an intrinsically random number which has fluctuations of order N1/2 if the average result is N. So if the number of photons, N, is limited by time or power considerations, shot noise places a fundamental limitation on the precision to which intensity, and changes in intensity, can be measured. This is particularly critical for "one-shot" ultra-sensitive experiments, such as the detection of a gravitational burst using large-scale interferometers.

Physics World•Aug 1, 1992•1 citation

Precision measurement beyond the shot-noise limit

Min Xiao, Ling-An Wu, Harry J. Kimble

An improvement in precision beyond the limit set by the vacuum-state or zero-point fluctuations of the electromagnetic field is reported for the measurement of phase modulation in an optical interferometer. The experiment makes use of squeezed light to reduce the level of fluctuations below the shot-noise limit. An increase in the signal-to-noise ratio of 3.0 dB relative to the shot-noise limit is demonstrated, with the improvement currently limited by losses in propagation and detection and not by the degree of available squeezing.

Physical Review Letters•Jul 20, 1987•823 citations

Quantum noise reduction using squeezed states inLIGO; Sensitivity improvement of a LIGO gravitational Waynedetector through squeezed state injection

S. E. Dwyer

Direct detection of gravitational waves will require earth based detectors to measure strains of the order 10-21, at frequencies of 100 Hz, a sensitivity that has been accomplished with the initial generation of LIGO interferometric gravitational wave detectors. A new generation of detectors currently under construction is designed improve on the sensitivity of the initial detectors by about a factor of 10. The quantum nature of light will limit the sensitivity of these Advanced LIGO interferometers at most frequencies; new approaches to reducing the quantum noise will be needed to improve the sensitivity further. This quantum noise originates from the vacuum fluctuations that enter the unused port of the interferometer and interfere with the laser light. Vacuum fluctuations have the minimum noise allowed by Heisenberg's uncertainty principle, [Delta]X1 [Delta]X2 >/=1, where the two quadratures X1 and X2 are non-commuting observables responsible for the two forms of quantum noise, shot noise and radiation pressure noise. By replacing the vacuum fluctuations entering the interferometer with squeezed states, which have lower noise in one quadrature than the vacuum state, we have reduced the shot noise of a LIGO interferometer. The sensitivity to gravitational waves measured during this experiment represents the best sensitivity achieved to date at frequencies above 200 Hz, and possibly the first time that squeezing has been measured in an interferometer at frequencies below 700 Hz. The possibility that injection of squeezed states could introduce environmental noise couplings that would degrade the crucial but fragile low frequency sensitivity of a LIGO interferometer has been a major concern in planning to implement squeezing as part of baseline interferometer operations. These results demonstrate that squeezing is compatible with the low frequency sensitivity of a full scale gravitational wave interferometer. We also investigated the limits to the level of squeezing observed, including optical losses and fluctuations of the squeezing angle. The lessons learned should allow for responsible planning to implement squeezing in Advanced LIGO, either as an alternative to high power operation or an early upgrade to improve the sensitivity. This thesis is available at DSpace@MIT and has LIGO document number P1300006.

•Jan 1, 2013•0 citations
Optimizing the sensitivity for interferometric measurement of optical phase involves maximizing the intensity of the illuminating light source and minimizing any noise sources. Limits to the light source intensity may arise from the availability of a stable high-power laser or from damage to the system being measured. For example, we describe here a scanning confocal polarization microscope designed to image the dynamics of nerve networks. In this case the light intensity limit is set by several factors, including the scanning rate, the required response time and damage limits of the biological system. Assuming a stable experimental configuration for the interferometer and light source, the limiting noise source for visible light interferometry is shot-noise associated with the quantum state of the light inputs to the interferometer. Shot-noise can be thought of as arising from vacuum fluctuations entering the dark input port of the interferometer.(1) These vacuum field fluctuations combine with the light entering the other port to cause shot-noise in the detected photocurrent at the output ports of the interferometer. This shot-noise current normally limits the measured phase variance Δϕ to a value of 1/N where N is the average number of photons detected in a measurement interval. We describe an experiment which demonstrates that this shot-noise limit can be improved by injecting squeezed vacuum into the normally dark input port.(2) In this case the phase variance is reduced below the 1/N limit by the degree of squeezing. In contrast to early experiments,(2) we are now operating the interferometer in a dark fringe mode(3–5) in order to avoid setting a limit to the light level caused by detector saturation (near 1 mW).
An experimental study of enhancement of interferometric sensitivity using squeezed vacuum fluctuations is described. By operating an interferometer at the dark fringe, large laser powers can be used for high sensitivity. It is possible to enhance the interferometric sensitivity beyond the shot-noise limit in the dark fringe arrangement by using an electrooptic modulator in the interferometer to vary the phase periodically away from the dark fringe. A detector at the dark output port can then operate at the shot-noise limit and detect phase imbalance at the sensitivity determined by power level at the bright output port.1 This shot-noise limit can be reduced further by illuminating the dark input port with squeezed vacuum, as demonstrated recently in balanced output port experiments.2,3 However, there are interesting limits to the sensitivity improvement expected in the dark fringe case.1 The experimental arrangement includes a polarization interferometer illuminated with 100 mW of 1.064-μm wavelength light from a Nd:YAG cw laser. Squeezed vacuum is generated by a KTP optical parametric amplifier. Experimental progress is reported at sensitivities in the nanoradian polarization rotation range.
Quantum noise limited interferometry for subhertz phase measurement is of essence in precision metrology applications, such as gravitational wave detection. However, suppression of subhertz classical noises below the shot-noise level is very challenging in practice. Two-frequency interferometry has been previously proposed to avoid low-frequency noises and may be useful for squeezing-enhanced high-precision phase measurement. Here we experimentally demonstrate a subhertz interferometer at the standard quantum noise (shot-noise) limit, by use of dual-frequency coherent probe light at the input and phase-sensitive heterodyne detection to measure the output interfered light. When the interferometer is locked at a dark fringe, the noise floor of the phase variance in the interferometer reaches the shot-noise level down to Fourier frequencies below 1 Hz. This work should pave a way for a realization of subhertz interferometry beyond the shot-noise limit.
Improvements in precision beyond the limit set by the vacuum state or zero-point fluctuations of the field are reported for two optical experiments. Both experiments employ the squeezed light from an optical parametric oscillator to reduce the level of fluctuations in one of two quadrature phase amplitudes below the shot-noise level (SNL). The first experiment follows the work of Caves1 on precision interferometry with squeezed states. An increase in signal-to-noise of 2.5 dB relative to the SNL is demonstrated for the detection of phase modulation in a Mach-Zehnder interferometer. In the second experiment amplitude modulation is encoded on a weak signal beam with an acoustooptic modulator. For the case of a squeezed signal beam compared with a beam in a coherent state, an improvement in sensitivity of 2.5 dB is achieved for the detection of amplitude changes of the field. The observed increases in sensitivity in both experiments are currently limited by simple linear losses in propagation and detection and not by the degree of available squeezing.
For many years the "shot-noise limit" has been considered as the fundamental limitation on measurements made with light beams. Shot noise is due to the quantum nature of light: the number of photons detected in a given time from a "stable" light beam (for instance, a laser beam) is an intrinsically random number which has fluctuations of order N1/2 if the average result is N. So if the number of photons, N, is limited by time or power considerations, shot noise places a fundamental limitation on the precision to which intensity, and changes in intensity, can be measured. This is particularly critical for "one-shot" ultra-sensitive experiments, such as the detection of a gravitational burst using large-scale interferometers.
An improvement in precision beyond the limit set by the vacuum-state or zero-point fluctuations of the electromagnetic field is reported for the measurement of phase modulation in an optical interferometer. The experiment makes use of squeezed light to reduce the level of fluctuations below the shot-noise limit. An increase in the signal-to-noise ratio of 3.0 dB relative to the shot-noise limit is demonstrated, with the improvement currently limited by losses in propagation and detection and not by the degree of available squeezing.
Direct detection of gravitational waves will require earth based detectors to measure strains of the order 10-21, at frequencies of 100 Hz, a sensitivity that has been accomplished with the initial generation of LIGO interferometric gravitational wave detectors. A new generation of detectors currently under construction is designed improve on the sensitivity of the initial detectors by about a factor of 10. The quantum nature of light will limit the sensitivity of these Advanced LIGO interferometers at most frequencies; new approaches to reducing the quantum noise will be needed to improve the sensitivity further. This quantum noise originates from the vacuum fluctuations that enter the unused port of the interferometer and interfere with the laser light. Vacuum fluctuations have the minimum noise allowed by Heisenberg's uncertainty principle, [Delta]X1 [Delta]X2 >/=1, where the two quadratures X1 and X2 are non-commuting observables responsible for the two forms of quantum noise, shot noise and radiation pressure noise. By replacing the vacuum fluctuations entering the interferometer with squeezed states, which have lower noise in one quadrature than the vacuum state, we have reduced the shot noise of a LIGO interferometer. The sensitivity to gravitational waves measured during this experiment represents the best sensitivity achieved to date at frequencies above 200 Hz, and possibly the first time that squeezing has been measured in an interferometer at frequencies below 700 Hz. The possibility that injection of squeezed states could introduce environmental noise couplings that would degrade the crucial but fragile low frequency sensitivity of a LIGO interferometer has been a major concern in planning to implement squeezing as part of baseline interferometer operations. These results demonstrate that squeezing is compatible with the low frequency sensitivity of a full scale gravitational wave interferometer. We also investigated the limits to the level of squeezing observed, including optical losses and fluctuations of the squeezing angle. The lessons learned should allow for responsible planning to implement squeezing in Advanced LIGO, either as an alternative to high power operation or an early upgrade to improve the sensitivity. This thesis is available at DSpace@MIT and has LIGO document number P1300006.