Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Conference on Lasers and Electro-Optics

Overcoming detection losses in a supersensitive interferometer with coherent and squeezed vacuum inputs

Gaetano Frascella, Sascha Agne, Farid Ya Khalili, Maria V. Chekhova

Published Jan 1, 2020• 1 citation
Publisher

Abstract

We report phase sensitivity overcoming the shot-noise limit by 3 dB for a squeezing-assisted interferometer with 50% detection losses. The performance is tolerant to losses up to 87% because of an optical parametric amplifier at the output.
DOI
10.1364/cleo_at.2020.jth4b.6

Related papers

Overcoming detection inefficiency in squeezing-assisted interferometers

Gaetano Frascella, Sascha Agne, Farid Ya Khalili +1 more

Squeezing-assisted interferometers achieve sub-shot-noise sensitivity to phase shifts, but losses can strongly degrade their performance. Here we present the first experimental demonstration of detection-loss tolerance for this class of interferometers employing degenerate optical parametric amplification at one output port. For $50\%$ detection efficiency, the phase sensitivity of any interferometer with coherent and squeezed vacuum inputs would not overcome the shot-noise limit, but in our case the output amplification gives $6$ dB sub-shot-noise sensitivity. We further demonstrate that robustness increases with higher gain of the output amplifier: sub-shot-noise sensitivity is achieved for detection efficiency as low as $13\%$. We believe that overcoming detection inefficiency will become crucial to take full advantage of quantum metrology, for example in gravitational-wave detection, quantum sensing and imaging.

•May 18, 2020•0 citations

Loss-tolerant interferometry with squeezed light

Maria V. Chekhova, Gaetano Frascella, Sascha Agne +1 more

An important part of optical sensing is interferometry, where direct or homodyne detection at the output of an interferometer yields information about small phase shifts. Classical interferometry operates at the shot-noise limit (SNL), caused by the photon structure of light and reached when an interferometer is fed with coherent light. The use of nonclassical light at the input of an interferometer enables overcoming the SNL. In particular, squeezed light is known to be less noisy than coherent light. An interferometer fed with strongly squeezed light can, in principle, provide the phase sensitivity at the Heisenberg limit, the ultimate limit allowed by the laws of physics. However, this supersensitive operation is strongly degraded by loss – both inside the interferometer and outside it, at the stage of detection. While the former (internal loss) seems to be inevitable, the latter (detection loss) can be overcome, and we demonstrate it in our recent experiment. The clue is to amplify light at the interferometer output using a phase-sensitive optical parametric amplifier. This device does not introduce additional noise, but it amplifies the fragile quantum signal and thus makes it tolerant to loss at the detection stage. In a proof-of-principle experiment, we build a polarization Mach-Zehnder interferometer and feed it with coherent light in one port and a squeezed vacuum in another port. At one output port, we amplify light with an optical parametric amplifier and measure a phase sensitivity of 13 mrad for 1500 photons in the interferometer. This result, achieved with 50% detection efficiency, overcomes the SNL by 3 dB. Moreover, by using stronger amplification, we can overcome the SNL under detection efficiency as low as 13%. Our results outline a way to use squeezed light for real-life sensing, where the detection efficiency cannot be very high, especially in spectral ranges like middle-infrared or terahertz.

Emerging Imaging and Sensing Technologies for Security and Defence; and Advanced Manufacturing Technologies for Micro- and Nanosystems in Security and Defence•Sep 18, 2020•0 citations

Detection Loss Tolerant Supersensitive Phase Measurement with an SU(1,1) Interferometer

Mathieu Manceau, Gerd Leuchs, Farid Ya Khalili +1 more

In an unseeded SU(1,1) interferometer composed of two cascaded degenerate parametric amplifiers, with direct detection at the output, we demonstrate a phase sensitivity overcoming the shot noise limit by 2.3 dB. The interferometer is strongly unbalanced, with the parametric gain of the second amplifier exceeding the gain of the first one by a factor of 2, which makes the scheme extremely tolerant to detection losses. We show that by increasing the gain of the second amplifier, the phase supersensitivity of the interferometer can be preserved even with detection losses as high as 80%. This finding can considerably improve the state-of-the-art interferometry, enable sub-shot-noise phase sensitivity in spectral ranges with inefficient detection, and allow extension to quantum imaging.

arXiv:1705.02662•Physical Review Letters•Nov 29, 2017•171 citations

Phase estimation in an SU(1,1) interferometer with displaced squeezed states

Sushovit Adhikari, Narayan Bhusal, Chenglong You +2 more

In this paper, we study the phase sensitivity of an SU(1,1) interferometer with coherent and displaced-squeezed-vacuum (DSV) states as inputs, and parity and on-off as detection strategies. Our scheme with parity is sub-shotnoise limited and approaches the Heisenberg limit with increasing squeezing strength of the optical parametric amplifier (OPA). Also, for the on-off detection scheme, we show that sub-shotnoise sensitivity is possible by increasing the squeezing strength of the OPA.

OSA Continuum•Sep 18, 2018•21 citations

Overcoming detection loss and noise in squeezing-based optical sensing

Gaetano Frascella, Sascha Agne, Farid Ya. Khalili +1 more

Abstract Among the known resources of quantum metrology, one of the most practical and efficient is squeezing. Squeezed states of atoms and light improve the sensing of the phase, magnetic field, polarization, mechanical displacement. They promise to considerably increase signal-to-noise ratio in imaging and spectroscopy, and are already used in real-life gravitational-wave detectors. But despite being more robust than other states, they are still very fragile, which narrows the scope of their application. In particular, squeezed states are useless in measurements where the detection is inefficient or the noise is high. Here, we experimentally demonstrate a remedy against loss and noise: strong noiseless amplification before detection. This way, we achieve loss-tolerant operation of an interferometer fed with squeezed and coherent light. With only 50% detection efficiency and with noise exceeding the level of squeezed light more than 50 times, we overcome the shot-noise limit by 6 dB. Sub-shot-noise phase sensitivity survives up to 87% loss. Application of this technique to other types of optical sensing and imaging promises a full use of quantum resources in these fields.

arXiv:2005.08843•npj Quantum Information•May 12, 2021•68 citations

Phase estimation in an SU(1,1) interferometer with displaced squeezed states

Sushovit Adhikari, Narayan Bhusal, Chenglong You +2 more

In this paper, we study the phase sensitivity of an SU(1,1) interferometer with coherent and displaced-squeezed-vacuum (DSV) states as inputs, and parity and on-off as detection strategies. Our scheme with parity is sub-shotnoise limited and approaches the Heisenberg limit with increasing squeezing strength of the optical parametric amplifier (OPA). Also, for the on-off detection scheme, we show that sub-shotnoise sensitivity is possible by increasing the squeezing strength of the OPA.

Bulletin of the American Physical Society•Mar 5, 2019•0 citations
Squeezing-assisted interferometers achieve sub-shot-noise sensitivity to phase shifts, but losses can strongly degrade their performance. Here we present the first experimental demonstration of detection-loss tolerance for this class of interferometers employing degenerate optical parametric amplification at one output port. For 50%50\%50% detection efficiency, the phase sensitivity of any interferometer with coherent and squeezed vacuum inputs would not overcome the shot-noise limit, but in our case the output amplification gives 666 dB sub-shot-noise sensitivity. We further demonstrate that robustness increases with higher gain of the output amplifier: sub-shot-noise sensitivity is achieved for detection efficiency as low as 13%13\%13%. We believe that overcoming detection inefficiency will become crucial to take full advantage of quantum metrology, for example in gravitational-wave detection, quantum sensing and imaging.
An important part of optical sensing is interferometry, where direct or homodyne detection at the output of an interferometer yields information about small phase shifts. Classical interferometry operates at the shot-noise limit (SNL), caused by the photon structure of light and reached when an interferometer is fed with coherent light. The use of nonclassical light at the input of an interferometer enables overcoming the SNL. In particular, squeezed light is known to be less noisy than coherent light. An interferometer fed with strongly squeezed light can, in principle, provide the phase sensitivity at the Heisenberg limit, the ultimate limit allowed by the laws of physics. However, this supersensitive operation is strongly degraded by loss – both inside the interferometer and outside it, at the stage of detection. While the former (internal loss) seems to be inevitable, the latter (detection loss) can be overcome, and we demonstrate it in our recent experiment. The clue is to amplify light at the interferometer output using a phase-sensitive optical parametric amplifier. This device does not introduce additional noise, but it amplifies the fragile quantum signal and thus makes it tolerant to loss at the detection stage. In a proof-of-principle experiment, we build a polarization Mach-Zehnder interferometer and feed it with coherent light in one port and a squeezed vacuum in another port. At one output port, we amplify light with an optical parametric amplifier and measure a phase sensitivity of 13 mrad for 1500 photons in the interferometer. This result, achieved with 50% detection efficiency, overcomes the SNL by 3 dB. Moreover, by using stronger amplification, we can overcome the SNL under detection efficiency as low as 13%. Our results outline a way to use squeezed light for real-life sensing, where the detection efficiency cannot be very high, especially in spectral ranges like middle-infrared or terahertz.
In an unseeded SU(1,1) interferometer composed of two cascaded degenerate parametric amplifiers, with direct detection at the output, we demonstrate a phase sensitivity overcoming the shot noise limit by 2.3 dB. The interferometer is strongly unbalanced, with the parametric gain of the second amplifier exceeding the gain of the first one by a factor of 2, which makes the scheme extremely tolerant to detection losses. We show that by increasing the gain of the second amplifier, the phase supersensitivity of the interferometer can be preserved even with detection losses as high as 80%. This finding can considerably improve the state-of-the-art interferometry, enable sub-shot-noise phase sensitivity in spectral ranges with inefficient detection, and allow extension to quantum imaging.
Abstract Among the known resources of quantum metrology, one of the most practical and efficient is squeezing. Squeezed states of atoms and light improve the sensing of the phase, magnetic field, polarization, mechanical displacement. They promise to considerably increase signal-to-noise ratio in imaging and spectroscopy, and are already used in real-life gravitational-wave detectors. But despite being more robust than other states, they are still very fragile, which narrows the scope of their application. In particular, squeezed states are useless in measurements where the detection is inefficient or the noise is high. Here, we experimentally demonstrate a remedy against loss and noise: strong noiseless amplification before detection. This way, we achieve loss-tolerant operation of an interferometer fed with squeezed and coherent light. With only 50% detection efficiency and with noise exceeding the level of squeezed light more than 50 times, we overcome the shot-noise limit by 6 dB. Sub-shot-noise phase sensitivity survives up to 87% loss. Application of this technique to other types of optical sensing and imaging promises a full use of quantum resources in these fields.