Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1705.02662 · Physical Review Letters

Detection Loss Tolerant Supersensitive Phase Measurement with an SU(1,1) Interferometer

Mathieu Manceau, Gerd Leuchs, Farid Ya Khalili, Maria V. Chekhova

Published Nov 29, 2017• 171 citations
arXivHTMLPDF

Abstract

In an unseeded SU(1,1) interferometer composed of two cascaded degenerate parametric amplifiers, with direct detection at the output, we demonstrate a phase sensitivity overcoming the shot noise limit by 2.3 dB. The interferometer is strongly unbalanced, with the parametric gain of the second amplifier exceeding the gain of the first one by a factor of 2, which makes the scheme extremely tolerant to detection losses. We show that by increasing the gain of the second amplifier, the phase supersensitivity of the interferometer can be preserved even with detection losses as high as 80%. This finding can considerably improve the state-of-the-art interferometry, enable sub-shot-noise phase sensitivity in spectral ranges with inefficient detection, and allow extension to quantum imaging.

DOI
10.1103/physrevlett.119.223604

Related papers

Overcoming detection losses in a supersensitive interferometer with coherent and squeezed vacuum inputs

Gaetano Frascella, Sascha Agne, Farid Ya Khalili +1 more

We report phase sensitivity overcoming the shot-noise limit by 3 dB for a squeezing-assisted interferometer with 50% detection losses. The performance is tolerant to losses up to 87% because of an optical parametric amplifier at the output.

Conference on Lasers and Electro-Optics•Jan 1, 2020•1 citation

Improving the phase super-sensitivity of squeezing-assisted interferometers by squeeze factor unbalancing

Mathieu Manceau, Farid Ya Khalili, Maria V. Chekhova

The sensitivity properties of an SU(1,1) interferometer made of two cascaded parametric amplifiers, as well as of an ordinary SU(2) interferometer preceded by a squeezer and followed by an anti-squeezer, are theoretically investigated.Several possible experimental configurations are considered, such as the absence or presence of a seed beam, direct or homodyne detection scheme.In all cases we formulate the optimal conditions to achieve phase super-sensitivity, meaning a sensitivity overcoming the shotnoise limit.We show that for a given gain of the first parametric amplifier, unbalancing the interferometer by increasing the gain of the second amplifier improves the interferometer properties.In particular, a broader super-sensitivity phase range and a better overall sensitivity can be achieved by gain unbalancing.

arXiv:1607.07332•New Journal of Physics•Dec 15, 2016•69 citations

Overcoming detection inefficiency in squeezing-assisted interferometers

Gaetano Frascella, Sascha Agne, Farid Ya Khalili +1 more

Squeezing-assisted interferometers achieve sub-shot-noise sensitivity to phase shifts, but losses can strongly degrade their performance. Here we present the first experimental demonstration of detection-loss tolerance for this class of interferometers employing degenerate optical parametric amplification at one output port. For $50\%$ detection efficiency, the phase sensitivity of any interferometer with coherent and squeezed vacuum inputs would not overcome the shot-noise limit, but in our case the output amplification gives $6$ dB sub-shot-noise sensitivity. We further demonstrate that robustness increases with higher gain of the output amplifier: sub-shot-noise sensitivity is achieved for detection efficiency as low as $13\%$. We believe that overcoming detection inefficiency will become crucial to take full advantage of quantum metrology, for example in gravitational-wave detection, quantum sensing and imaging.

•May 18, 2020•0 citations

Loss-tolerant interferometry with squeezed light

Maria V. Chekhova, Gaetano Frascella, Sascha Agne +1 more

An important part of optical sensing is interferometry, where direct or homodyne detection at the output of an interferometer yields information about small phase shifts. Classical interferometry operates at the shot-noise limit (SNL), caused by the photon structure of light and reached when an interferometer is fed with coherent light. The use of nonclassical light at the input of an interferometer enables overcoming the SNL. In particular, squeezed light is known to be less noisy than coherent light. An interferometer fed with strongly squeezed light can, in principle, provide the phase sensitivity at the Heisenberg limit, the ultimate limit allowed by the laws of physics. However, this supersensitive operation is strongly degraded by loss – both inside the interferometer and outside it, at the stage of detection. While the former (internal loss) seems to be inevitable, the latter (detection loss) can be overcome, and we demonstrate it in our recent experiment. The clue is to amplify light at the interferometer output using a phase-sensitive optical parametric amplifier. This device does not introduce additional noise, but it amplifies the fragile quantum signal and thus makes it tolerant to loss at the detection stage. In a proof-of-principle experiment, we build a polarization Mach-Zehnder interferometer and feed it with coherent light in one port and a squeezed vacuum in another port. At one output port, we amplify light with an optical parametric amplifier and measure a phase sensitivity of 13 mrad for 1500 photons in the interferometer. This result, achieved with 50% detection efficiency, overcomes the SNL by 3 dB. Moreover, by using stronger amplification, we can overcome the SNL under detection efficiency as low as 13%. Our results outline a way to use squeezed light for real-life sensing, where the detection efficiency cannot be very high, especially in spectral ranges like middle-infrared or terahertz.

Emerging Imaging and Sensing Technologies for Security and Defence; and Advanced Manufacturing Technologies for Micro- and Nanosystems in Security and Defence•Sep 18, 2020•0 citations

Phase sensitivity of gain-unbalanced nonlinear interferometers

Enno Giese, Samuel Lemieux, Mathieu Manceau +2 more

The phase uncertainty of an unseeded nonlinear interferometer, where the output of one nonlinear crystal is transmitted to the input of a second crystal that analyzes it, is commonly said to be below the shot-noise level but highly dependent on detection and internal loss. Unbalancing the gains of the first (source) and second (analyzer) crystals leads to a configuration that is tolerant against detection loss. However, in terms of sensitivity, there is no advantage in choosing a stronger analyzer over a stronger source, and hence the comparison to a shot-noise level is not straightforward. Internal loss breaks this symmetry and shows that it is crucial whether the source or analyzer is dominating. Based on these results, claiming a Heisenberg scaling of the sensitivity is more subtle than in a balanced setup.

arXiv:1711.06226•Physical Review A•Nov 29, 2017•43 citations

Sensitivity Evaluation of SU(1,1) Interferometers with Arbitrary Input Probe State and Homodyne Detections

Sonu Jana, Dhruv Baheti, Paul Grossiord +3 more

We provide a general theoretical derivation of the phase sensitivity achieved by SU(1,1) interferometers under homodyne detection. The general expressions obtained accommodate arbitrary input states and include internal and external losses. In this systematic review, both full SU(1,1) interferometers with two parametric amplifiers and the truncated interferometers with only one parametric amplifier are examined. We investigate scenarios involving both single-output ports and joint homodyne detection, and consider parametric amplifiers with equal gains or with a boosted gain second amplifier. Our analytical formulation provides physical insight and understanding of the improvements in the sensitivity, which are shown to originate from noise reduction and/or signal amplification, depending on the configurations and practical implementations. Surprisingly, the configuration with single-output mode detection and parametric amplifiers with equal gains exhibits the highest robustness to very high internal losses. We finally apply this framework to a ubiquitous $|α,0\rangle$ input two-mode coherent probe state. This approach permits the comparison of different strategies and the optimization of the interferometer performance in the presence of losses. In particular, we determine which amplification and detection configurations provide the best performance, depending on the level of losses. This exemplifies how this general analytical approach provides a powerful tool to design quantum-enhanced interferometers and achieve optimal sensitivity with selected probe states and homodyne detection.

quant-pharXiv:2605.22029•May 22, 2026•0 citations
In an unseeded SU(1,1) interferometer composed of two cascaded degenerate parametric amplifiers, with direct detection at the output, we demonstrate a phase sensitivity overcoming the shot noise limit by 2.3 dB. The interferometer is strongly unbalanced, with the parametric gain of the second amplifier exceeding the gain of the first one by a factor of 2, which makes the scheme extremely tolerant to detection losses. We show that by increasing the gain of the second amplifier, the phase supersensitivity of the interferometer can be preserved even with detection losses as high as 80%. This finding can considerably improve the state-of-the-art interferometry, enable sub-shot-noise phase sensitivity in spectral ranges with inefficient detection, and allow extension to quantum imaging.
The sensitivity properties of an SU(1,1) interferometer made of two cascaded parametric amplifiers, as well as of an ordinary SU(2) interferometer preceded by a squeezer and followed by an anti-squeezer, are theoretically investigated.Several possible experimental configurations are considered, such as the absence or presence of a seed beam, direct or homodyne detection scheme.In all cases we formulate the optimal conditions to achieve phase super-sensitivity, meaning a sensitivity overcoming the shotnoise limit.We show that for a given gain of the first parametric amplifier, unbalancing the interferometer by increasing the gain of the second amplifier improves the interferometer properties.In particular, a broader super-sensitivity phase range and a better overall sensitivity can be achieved by gain unbalancing.
Squeezing-assisted interferometers achieve sub-shot-noise sensitivity to phase shifts, but losses can strongly degrade their performance. Here we present the first experimental demonstration of detection-loss tolerance for this class of interferometers employing degenerate optical parametric amplification at one output port. For 50%50\%50% detection efficiency, the phase sensitivity of any interferometer with coherent and squeezed vacuum inputs would not overcome the shot-noise limit, but in our case the output amplification gives 666 dB sub-shot-noise sensitivity. We further demonstrate that robustness increases with higher gain of the output amplifier: sub-shot-noise sensitivity is achieved for detection efficiency as low as 13%13\%13%. We believe that overcoming detection inefficiency will become crucial to take full advantage of quantum metrology, for example in gravitational-wave detection, quantum sensing and imaging.
An important part of optical sensing is interferometry, where direct or homodyne detection at the output of an interferometer yields information about small phase shifts. Classical interferometry operates at the shot-noise limit (SNL), caused by the photon structure of light and reached when an interferometer is fed with coherent light. The use of nonclassical light at the input of an interferometer enables overcoming the SNL. In particular, squeezed light is known to be less noisy than coherent light. An interferometer fed with strongly squeezed light can, in principle, provide the phase sensitivity at the Heisenberg limit, the ultimate limit allowed by the laws of physics. However, this supersensitive operation is strongly degraded by loss – both inside the interferometer and outside it, at the stage of detection. While the former (internal loss) seems to be inevitable, the latter (detection loss) can be overcome, and we demonstrate it in our recent experiment. The clue is to amplify light at the interferometer output using a phase-sensitive optical parametric amplifier. This device does not introduce additional noise, but it amplifies the fragile quantum signal and thus makes it tolerant to loss at the detection stage. In a proof-of-principle experiment, we build a polarization Mach-Zehnder interferometer and feed it with coherent light in one port and a squeezed vacuum in another port. At one output port, we amplify light with an optical parametric amplifier and measure a phase sensitivity of 13 mrad for 1500 photons in the interferometer. This result, achieved with 50% detection efficiency, overcomes the SNL by 3 dB. Moreover, by using stronger amplification, we can overcome the SNL under detection efficiency as low as 13%. Our results outline a way to use squeezed light for real-life sensing, where the detection efficiency cannot be very high, especially in spectral ranges like middle-infrared or terahertz.
The phase uncertainty of an unseeded nonlinear interferometer, where the output of one nonlinear crystal is transmitted to the input of a second crystal that analyzes it, is commonly said to be below the shot-noise level but highly dependent on detection and internal loss. Unbalancing the gains of the first (source) and second (analyzer) crystals leads to a configuration that is tolerant against detection loss. However, in terms of sensitivity, there is no advantage in choosing a stronger analyzer over a stronger source, and hence the comparison to a shot-noise level is not straightforward. Internal loss breaks this symmetry and shows that it is crucial whether the source or analyzer is dominating. Based on these results, claiming a Heisenberg scaling of the sensitivity is more subtle than in a balanced setup.
We provide a general theoretical derivation of the phase sensitivity achieved by SU(1,1) interferometers under homodyne detection. The general expressions obtained accommodate arbitrary input states and include internal and external losses. In this systematic review, both full SU(1,1) interferometers with two parametric amplifiers and the truncated interferometers with only one parametric amplifier are examined. We investigate scenarios involving both single-output ports and joint homodyne detection, and consider parametric amplifiers with equal gains or with a boosted gain second amplifier. Our analytical formulation provides physical insight and understanding of the improvements in the sensitivity, which are shown to originate from noise reduction and/or signal amplification, depending on the configurations and practical implementations. Surprisingly, the configuration with single-output mode detection and parametric amplifiers with equal gains exhibits the highest robustness to very high internal losses. We finally apply this framework to a ubiquitous ∣α,0⟩|α,0\rangle∣α,0⟩ input two-mode coherent probe state. This approach permits the comparison of different strategies and the optimization of the interferometer performance in the presence of losses. In particular, we determine which amplification and detection configurations provide the best performance, depending on the level of losses. This exemplifies how this general analytical approach provides a powerful tool to design quantum-enhanced interferometers and achieve optimal sensitivity with selected probe states and homodyne detection.