We theoretically study the phase sensitivity of an SU(1,1) interferometer with a coherent state in one input port and a squeezed-vacuum state in the other input port using the method of homodyne detection. In this interferometer, beam splitting and recombination are generated by the parametric amplifiers instead of the beam splitters. Compared with the traditional Mach–Zehnder interferometer, the phase sensitivity of this interferometer can be improved due to the amplification process of the parametric amplifiers. Combined with the squeezed state input, the sensitivity can be improved further due to the noise reduction. The phase sensitivity of our scheme can approach the Heisenberg limit and the associated optimal condition is analyzed. The scheme can be implemented with current experimental technology.
We theoretically study the phase sensitivity of an SU(1,1) interferometer with a coherent state in one input port and a squeezed-vacuum state in the other input port using the method of homodyne detection. In this interferometer, beam splitting and recombination are generated by the parametric amplifiers instead of the beam splitters. Compared with the traditional Mach–Zehnder interferometer, the phase sensitivity of this interferometer can be improved due to the amplification process of the parametric amplifiers. Combined with the squeezed state input, the sensitivity can be improved further due to the noise reduction. The phase sensitivity of our scheme can approach the Heisenberg limit and the associated optimal condition is analyzed. The scheme can be implemented with current experimental technology.
We theoretically investigate the phase sensitivity with parity detection on an SU(1,1) interferometer with a coherent state combined with a squeezed vacuum state. This interferometer is formed with two parametric amplifiers for beam splitting and recombination instead of beam splitters. We show that the sensitivity of phase estimation approaches the Heisenberg limit and give the corresponding optimal condition. Moreover, we derive the quantum Cram\'er-Rao bound of the SU(1,1) interferometer.
Phase sensitivity of an SU(1,1) interferometer via product detection
Abstract We theoretically analyze the phase sensitivity of an SU(1,1) SU ( 1 , 1 ) interferometer with various input states by product detection in this paper. This interferometer consists of two parametric amplifiers that play the role of beam splitters in a traditional Mach–Zehnder interferometer. The product of the amplitude quadrature of one output mode and the momentum quadrature of the other output mode is measured via balanced homodyne detection. We show that product detection has the same phase sensitivity as parity detection for most cases, and it is even better in the case with two coherent states at the input ports. The phase sensitivity is also compared with the Heisenberg limit and the quantum Cramér–Rao bound of the SU(1,1) SU ( 1 , 1 ) interferometer. This detection scheme can be easily implemented with current homodyne technology, which makes it highly feasible. It can be widely applied in the field of quantum metrology.
Improving interferometric phase sensitivity is crucial for high-precision measurements in rapidly developing quantum technologies. The Mach–Zehnder interferometer (MZI) is a versatile tool for analyzing this phenomenon. By splitting and recombining a light beam using beam splitters, the MZI allows for precise phase sensitivity analysis using tools like the quantum Cramér–Rao bound (QCRB) and the quantum Fisher information (QFI). This paper analyzes the phase sensitivity of an MZI in various scenarios using different detection schemes and input states. We compare the single- and two-parameter quantum estimation and their associated QCRB for three phase-shift situations: in both arms; only in the upper arm (asymmetric); and in both arms symmetrically. We then investigate the phase sensitivity under three detection schemes: intensity difference; single-mode intensity; and balanced homodyne. Additionally, we explore the use of Perelomov and Barut–Girardello coherent states, two types of SU(1,1) coherent states, in all scenarios. Notably, we demonstrate that, under optimal conditions, all detection schemes can achieve the QCRB by utilizing SU(1,1) coherent states as input states.
Introducing squeezed states of light into interferometers can increase the phase sensitivity of the device beyond the standard quantum limit (SQL). We discuss an SU(1,1) interferometer, where nonlinear optical elements replace the beam splitters in a Mach-Zehnder interferometer. A two-mode squeezed state of light is generated inside of such an interferometer. We talk about the phase sensitivities of an SU(1,1) interferometer with different detection schemes and their improvement over the SQL. We also discuss the concept of an optimal detection scheme for phase measurement in an interferometer. We describe a modification of the SU(1,1) interferometer which reduces the experimental complexities while giving the same phase sensitivity. We call the design a truncated SU(1,1) interferometer. We show our experimental results of 4 dB improvement in phase sensitivity over the SQL using a truncated SU(1,1) interferometer. We also compare the theoretical sensitivities of vacuum-seeded configurations of a conventional and a truncated SU(1,1) interferometer, and show our experimental results for the phase sensitivity of the truncated version. We explain the dependence of phase sensitivity on the measurement of squeezing. We talk about the methods to improve the measurement of squeezing in a 4-wave mixing experiment, and our efforts in implementing them. Finally, we mention our progress in measuring a big phase shift using an adaptive algorithm in the truncated SU(1,1) interferometer, and discuss the technicalities involved in big phase measurements.
We provide a general theoretical derivation of the phase sensitivity achieved by SU(1,1) interferometers under homodyne detection. The general expressions obtained accommodate arbitrary input states and include internal and external losses. In this systematic review, both full SU(1,1) interferometers with two parametric amplifiers and the truncated interferometers with only one parametric amplifier are examined. We investigate scenarios involving both single-output ports and joint homodyne detection, and consider parametric amplifiers with equal gains or with a boosted gain second amplifier. Our analytical formulation provides physical insight and understanding of the improvements in the sensitivity, which are shown to originate from noise reduction and/or signal amplification, depending on the configurations and practical implementations. Surprisingly, the configuration with single-output mode detection and parametric amplifiers with equal gains exhibits the highest robustness to very high internal losses. We finally apply this framework to a ubiquitous ∣α,0⟩ input two-mode coherent probe state. This approach permits the comparison of different strategies and the optimization of the interferometer performance in the presence of losses. In particular, we determine which amplification and detection configurations provide the best performance, depending on the level of losses. This exemplifies how this general analytical approach provides a powerful tool to design quantum-enhanced interferometers and achieve optimal sensitivity with selected probe states and homodyne detection.
Abstract The SU(1,1) interferometer, a nonlinear analog of the traditional Mach–Zehnder interferometer, has emerged as a powerful tool for achieving phase sensitivity beyond the standard quantum limit. In this work, we propose the use of a superposition of even and odd coherent states as input state to enhance the phase sensitivity of an SU(1,1) interferometer. These non-classical states exhibit unique properties such as squeezing, entanglement, and quantum interference, which can be harnessed to improve metrological precision. Phase sensitivity is analyzed using single-intensity detection and homodyne detection schemes under both ideal and photon loss cases, which demonstrates significant improvements over classical and squeezed-vacuum inputs. In addition, we evaluate the quantum Cramér-Rao lower bound by employing the quantum Fisher information formalism, showing that it surpasses the standard quantum limit and approaches the Heisenberg limit under optimal conditions. Our results highlight the potential of the even and odd coherent states superposition in quantum metrology and provide a pathway for achieving ultra-precise phase measurements in SU(1,1) interferometers for applications in optical sensing, and quantum information processing.