Chinese Physics B

Realization of ultralow power phase locking by optimizing Q factor of resonant photodetector*

JinRong Wang, Hongyu Zhang, Zilin Zhao, Yaohui Zheng

Published Sep 28, 2020• 6 citations
Publisher

Abstract

We design and construct a resonant photodetector (RPD) with a Q factor of 320.83 at the resonant frequency of 38.5 MHz on the basis of a theoretical analysis. Compared with the existing RPD under the same conditions, the signal-to-noise-ratio of the error signal is increased by 15 dB and the minimum operation power is reduced from −55 dBm to −70 dBm. By comparing the standard deviations of the stability curves, we confirm that the RPD has a dramatic improvement on ultralow power extraction. In virtue of the RPD, we have completed the demonstration of channel multiplexing quantum communication.

DOI
10.1088/1674-1056/abbbfb

Related papers

Design of low-noise photodetector with a bandwidth of 130 MHz based on transimpedance amplification circuit

Jiliang Qin, Zhihui Yan, Meiru Huo +2 more

A low-noise photodetector is a basic tool for the research of quantum information processing.We present a specially designed low-noise photoelectric detector with a bandwidth of 130 MHz, using a transimpedance amplification circuit.Based on the detailed calculation of the dependence on each parameter of the detector, a useful method of how to design a low-noise and broadband photodetector is provided.When the optical power is between 1.0 and 16 mW, the photodetector has a good linear response to the injected light.Its electronics noise power is below -77 dBm, which is within the whole bandwidth.When the incident light power is 2 mW, the output noise powers are 10.0, 8.0, and 6.0 dB higher than the corresponding electronics noise within the bandwidth of 1-50, 50-90, and 90-130 MHz, respectively, which is in good agreement with the theoretical prediction.Thus, this photoelectric detector could have good application prospects in quantum communication and an optical cavity locking system.

Chinese Optics Letters•Jan 1, 2016•13 citations

Resonant photodetector for cavity- and phase-locking of squeezed state generation

Chaoyong Chen, Zhixiu Li, Xiaoli Jin +1 more

Based on the requirement of squeezed state generation, we build the phase relationship between two electronic local oscillators for the cavity- and phase-locking branches, and a 2-way 90° power splitter is adopted to satisfy the phase relationship simultaneously, which greatly simplifies the experimental setup and adjusting process. A LC parallel resonant circuit, which is composed by the inherent capacitance of a photodiode and an extra inductor, is adopted in the resonant photodetector to improve the gain factor at the expected frequency. The gain of the resonant photodetector is about 30 dB higher than that of the broadband photodetector at the resonant frequency. The peak-to-peak value of the error signal for cavity-locking (phase-locking) with the resonant photodetector is 240 (260) times of that with the broadband photodetector, which can improve the locking performance on the premise of not affecting the squeezing degree.

Review of Scientific Instruments•Oct 1, 2016•22 citations

20 MHz resonant photodetector for the homodyne measurement of picosecond pulsed squeezed light

Zhihao Li, Jun Liu, Fengjuan Guo +3 more

A high-performance resonant balanced homodyne detector is a key element for the measurement of picosecond pulsed squeezed light, which is an important quantum resource in quantum-enhanced microscopic imaging. In this paper, we design and demonstrate a resonant photodetector for homodyne measurement with a maximum signal-to-noise ratio of 22.42 dB at resonant frequency of 20 MHz. Using this detector to pulsed regime, a maximum signal-to-noise ratio at resonant frequency is 10.02 dB, where a 40 dB subtraction capability at 80 MHz repetition rate of pulsed laser is obtained. With this design, the quantum noise of picosecond pulsed squeezed light is measured and the best squeezing level −1.7 dB below the shot noise level is clearly observed at 20 MHz.

Optics Continuum•Feb 15, 2023•6 citations

高信噪比集成化共振光电探测器

李卫 Li Wei, 武志学 Wu Zhixue, 王庆伟 Wang Qingwei +7 more

Objective In squeezing-enhanced system, the stability and squeezing level of the squeezed states directly affect the improvement of quantum enhancement sensitivity and signal-to-noise ratio (SNR). Squeezed states can be generated by an optical parametric oscillator (OPO) based on second-order nonlinearity. At present, Pound-Drever-Hall (PDH) is the most commonly employed method for locking the OPO cavity, and the photodetector plays a key role in extracting extremely weak signals. For PDH locking systems, the useful signals coupled to photodetectors are narrowband signals at the modulated frequency, while the traditional wideband photodetectors amplify signals and noise in the whole frequency band, which is not conducive to improving the SNR. It is worth noting that the seed light is employed in the active stable parametric cavity in the preparation of the bright squeezed state, and the increased seed power will lead to the coupling of the pump noise into the bright squeezed state, thereby resulting in the reduced squeezing level. However, the increased optical power of extracting signal can improve the error signal of the locked parameter cavity. Thus, it is important to design photodetectors with high gain and SNR. Photodiodes have certain junction capacitance, and combined with variable inductance, inductance and capacitance (LC) resonance circuit can be formed to enhance the resonance of specific frequency signals. The detector is named resonant photodetector (RPD). The LC resonance circuit can be equivalent to the parallel resonance circuit and is regarded as a bandpass filter, which only amplifies the required frequency band and suppresses the noise of unnecessary frequency bands. However, the quality factor Q directly characterizes the suppression effect on the external noise signal of the resonant frequency, and the SNR of the error signal directly affects the minimum jitter of the cavity length and phase after locking. Methods To evaluate the newly designed RPD, this paper builds a test platform to evaluate transfer functions and error signals, as shown in Fig. 4. The laser source is a single-frequency laser of 1550 nm. The half-wave plate HWP1 is employed to adjust the laser power reaching the modulator, and HWP2 is to adjust the polarization direction of the laser, perpendicular or horizontal to the modulator. This means that the direction is 45°from the main axis of the electro-optical crystal. The network analyzer sets the start and end frequencies of the test (starting from 1-100 MHz in the experiment, and then being refined according to the resonance frequency). The output signal is divided into two parts, one of which is loaded on the modulator for modulating the laser beam, and the other is returned as a reference signal. The second part is the measurement of the error signal, which adopts the electro-optical modulator (EOM). MC is closely related to the preparation of high level squeezed state. According to PDH technology, the anti-interference ability of locking is proportional to the peak-to-peak value of the error signal, and the larger peak-to-peak value will lead to stronger anti-interference ability. In addition to the incident laser power, the amplitude and SNR of the error signal also depend on the signal extraction capability of the photodetector, so the SNR of the error signal extracted by the photodetector determines the stability of the whole feedback loop. Therefore, the performance of the developed resonant detector is evaluated by the SNR and the stability of the error signal in MC cavity locking. Results and Discussions This paper measures the transfer functions of commercial BPD (THORLABS PDA10D2) and RPD under the same conditions (Fig. 5). At the resonant frequency of 20 MHz, the gain of RPD is about 30 dB higher than that of BPD. The high gain helps to obtain a stable phase locking at lower power, thus improving the stability of the system in the squeezed state without reducing the quantum noise. Through external mixing and integrated circuit design, the 3 dB bandwidth of RPD is 0.285 MHz. The quality factor Q of RPD is 70 and can be calculated from the measurement results by Formula (5). The experimental results are shown in Figs. 6 and 7. The SNR improvement of the newly designed RPD is more obvious than that of BPD, and the SNR is defined as the ratio of the peak-to-peak value to the noise of the error signal. The error signal is a DC signal, which cannot be measured by a spectrum analyzer and can only be recorded by an oscilloscope. At the resonance frequency of 20 MHz, the peak-to-peak value of the RPD error signal is 560 mV, the peak-to-peak value of noise is 42 mV, and the SNR is about 22.5 dB. The peak-to-peak value of the BPD error signal is 35 mV, and the peak-to-peak value of noise is 20.8 mV. The SNR of the newly designed RPD is about 18 dB higher than that of BPD. Conclusions Based on the theoretical analysis of the resonance circuit and cross-resistance amplifier circuit, the selection of low noise devices, and the optimized circuit layout, this paper develops a resonant detector with Q factor of 70 and SNR of 22.5 dB. Compared with the traditional broadband photodetector (BPD), the gain of RPD at 20 MHz is about 30 dB higher than that of BPD. By measuring the peak-to-peak value and SNR of error signals, the peak-to-peak value of RPD locking cavity error signals is 16 times that of BPD, and the SNR of RPD error signals is about 18 dB higher than that of BPD under the same condition. This RPD can provide a key device for photoelectric feedback control and the preparation of continuous variable nonclassical light fields.

Acta Optica Sinica•Jan 1, 2023•4 citations

500 MHz resonant photodetector for high-quantum-efficiency, low-noise homodyne measurement

Takahiro Serikawa, Akira Furusawa

We design and demonstrate a resonant-type differential photodetector for a low-noise quantum homodyne measurement at 500 MHz optical sideband with 17 MHz of bandwidth. By using a microwave monolithic amplifier and a discrete voltage buffer circuit, a low-noise voltage amplifier is realized and applied to our detector. 12 dB of signal-to-noise ratio of the shot noise to the electric noise is obtained with 5 mW of a continuous-wave local oscillator. We analyze the frequency response and the noise characteristics of a resonant photodetector, and the theoretical model agrees with the shot noise measurement.

arXiv:1803.06462•Review of Scientific Instruments•Jun 1, 2018•29 citations

Low-noise, transformer-coupled resonant photodetector for squeezed state generation

Chaoyong Chen, Shaoping Shi, Yaohui Zheng

In an actual setup of squeezed state generation, the stability of a squeezing factor is mainly limited by the performance of the servo-control system, which is mainly influenced by the shot noise and gain of a photodetector. We present a unique transformer-coupled LC resonant amplifier as a photodetector circuit to reduce the electronic noise and increase the gain of the photodetector. As a result, we obtain a low-noise, high gain photodetector with the gain of more than 1.8×105 V/A, and the input current noise of less than 4.7 pA/Hz. By adjusting the parameters of the transformer, the quality factor Q of the resonant circuit is close to 100 in the frequency range of more than 100 MHz, which meets the requirement for weak power detection in the application of squeezed state generation.

Review of Scientific Instruments•Oct 1, 2017•20 citations
We design and construct a resonant photodetector (RPD) with a Q factor of 320.83 at the resonant frequency of 38.5 MHz on the basis of a theoretical analysis. Compared with the existing RPD under the same conditions, the signal-to-noise-ratio of the error signal is increased by 15 dB and the minimum operation power is reduced from −55 dBm to −70 dBm. By comparing the standard deviations of the stability curves, we confirm that the RPD has a dramatic improvement on ultralow power extraction. In virtue of the RPD, we have completed the demonstration of channel multiplexing quantum communication.
A low-noise photodetector is a basic tool for the research of quantum information processing.We present a specially designed low-noise photoelectric detector with a bandwidth of 130 MHz, using a transimpedance amplification circuit.Based on the detailed calculation of the dependence on each parameter of the detector, a useful method of how to design a low-noise and broadband photodetector is provided.When the optical power is between 1.0 and 16 mW, the photodetector has a good linear response to the injected light.Its electronics noise power is below -77 dBm, which is within the whole bandwidth.When the incident light power is 2 mW, the output noise powers are 10.0, 8.0, and 6.0 dB higher than the corresponding electronics noise within the bandwidth of 1-50, 50-90, and 90-130 MHz, respectively, which is in good agreement with the theoretical prediction.Thus, this photoelectric detector could have good application prospects in quantum communication and an optical cavity locking system.
Based on the requirement of squeezed state generation, we build the phase relationship between two electronic local oscillators for the cavity- and phase-locking branches, and a 2-way 90° power splitter is adopted to satisfy the phase relationship simultaneously, which greatly simplifies the experimental setup and adjusting process. A LC parallel resonant circuit, which is composed by the inherent capacitance of a photodiode and an extra inductor, is adopted in the resonant photodetector to improve the gain factor at the expected frequency. The gain of the resonant photodetector is about 30 dB higher than that of the broadband photodetector at the resonant frequency. The peak-to-peak value of the error signal for cavity-locking (phase-locking) with the resonant photodetector is 240 (260) times of that with the broadband photodetector, which can improve the locking performance on the premise of not affecting the squeezing degree.
A high-performance resonant balanced homodyne detector is a key element for the measurement of picosecond pulsed squeezed light, which is an important quantum resource in quantum-enhanced microscopic imaging. In this paper, we design and demonstrate a resonant photodetector for homodyne measurement with a maximum signal-to-noise ratio of 22.42 dB at resonant frequency of 20 MHz. Using this detector to pulsed regime, a maximum signal-to-noise ratio at resonant frequency is 10.02 dB, where a 40 dB subtraction capability at 80 MHz repetition rate of pulsed laser is obtained. With this design, the quantum noise of picosecond pulsed squeezed light is measured and the best squeezing level −1.7 dB below the shot noise level is clearly observed at 20 MHz.
Objective In squeezing-enhanced system, the stability and squeezing level of the squeezed states directly affect the improvement of quantum enhancement sensitivity and signal-to-noise ratio (SNR). Squeezed states can be generated by an optical parametric oscillator (OPO) based on second-order nonlinearity. At present, Pound-Drever-Hall (PDH) is the most commonly employed method for locking the OPO cavity, and the photodetector plays a key role in extracting extremely weak signals. For PDH locking systems, the useful signals coupled to photodetectors are narrowband signals at the modulated frequency, while the traditional wideband photodetectors amplify signals and noise in the whole frequency band, which is not conducive to improving the SNR. It is worth noting that the seed light is employed in the active stable parametric cavity in the preparation of the bright squeezed state, and the increased seed power will lead to the coupling of the pump noise into the bright squeezed state, thereby resulting in the reduced squeezing level. However, the increased optical power of extracting signal can improve the error signal of the locked parameter cavity. Thus, it is important to design photodetectors with high gain and SNR. Photodiodes have certain junction capacitance, and combined with variable inductance, inductance and capacitance (LC) resonance circuit can be formed to enhance the resonance of specific frequency signals. The detector is named resonant photodetector (RPD). The LC resonance circuit can be equivalent to the parallel resonance circuit and is regarded as a bandpass filter, which only amplifies the required frequency band and suppresses the noise of unnecessary frequency bands. However, the quality factor Q directly characterizes the suppression effect on the external noise signal of the resonant frequency, and the SNR of the error signal directly affects the minimum jitter of the cavity length and phase after locking. Methods To evaluate the newly designed RPD, this paper builds a test platform to evaluate transfer functions and error signals, as shown in Fig. 4. The laser source is a single-frequency laser of 1550 nm. The half-wave plate HWP1 is employed to adjust the laser power reaching the modulator, and HWP2 is to adjust the polarization direction of the laser, perpendicular or horizontal to the modulator. This means that the direction is 45°from the main axis of the electro-optical crystal. The network analyzer sets the start and end frequencies of the test (starting from 1-100 MHz in the experiment, and then being refined according to the resonance frequency). The output signal is divided into two parts, one of which is loaded on the modulator for modulating the laser beam, and the other is returned as a reference signal. The second part is the measurement of the error signal, which adopts the electro-optical modulator (EOM). MC is closely related to the preparation of high level squeezed state. According to PDH technology, the anti-interference ability of locking is proportional to the peak-to-peak value of the error signal, and the larger peak-to-peak value will lead to stronger anti-interference ability. In addition to the incident laser power, the amplitude and SNR of the error signal also depend on the signal extraction capability of the photodetector, so the SNR of the error signal extracted by the photodetector determines the stability of the whole feedback loop. Therefore, the performance of the developed resonant detector is evaluated by the SNR and the stability of the error signal in MC cavity locking. Results and Discussions This paper measures the transfer functions of commercial BPD (THORLABS PDA10D2) and RPD under the same conditions (Fig. 5). At the resonant frequency of 20 MHz, the gain of RPD is about 30 dB higher than that of BPD. The high gain helps to obtain a stable phase locking at lower power, thus improving the stability of the system in the squeezed state without reducing the quantum noise. Through external mixing and integrated circuit design, the 3 dB bandwidth of RPD is 0.285 MHz. The quality factor Q of RPD is 70 and can be calculated from the measurement results by Formula (5). The experimental results are shown in Figs. 6 and 7. The SNR improvement of the newly designed RPD is more obvious than that of BPD, and the SNR is defined as the ratio of the peak-to-peak value to the noise of the error signal. The error signal is a DC signal, which cannot be measured by a spectrum analyzer and can only be recorded by an oscilloscope. At the resonance frequency of 20 MHz, the peak-to-peak value of the RPD error signal is 560 mV, the peak-to-peak value of noise is 42 mV, and the SNR is about 22.5 dB. The peak-to-peak value of the BPD error signal is 35 mV, and the peak-to-peak value of noise is 20.8 mV. The SNR of the newly designed RPD is about 18 dB higher than that of BPD. Conclusions Based on the theoretical analysis of the resonance circuit and cross-resistance amplifier circuit, the selection of low noise devices, and the optimized circuit layout, this paper develops a resonant detector with Q factor of 70 and SNR of 22.5 dB. Compared with the traditional broadband photodetector (BPD), the gain of RPD at 20 MHz is about 30 dB higher than that of BPD. By measuring the peak-to-peak value and SNR of error signals, the peak-to-peak value of RPD locking cavity error signals is 16 times that of BPD, and the SNR of RPD error signals is about 18 dB higher than that of BPD under the same condition. This RPD can provide a key device for photoelectric feedback control and the preparation of continuous variable nonclassical light fields.
We design and demonstrate a resonant-type differential photodetector for a low-noise quantum homodyne measurement at 500 MHz optical sideband with 17 MHz of bandwidth. By using a microwave monolithic amplifier and a discrete voltage buffer circuit, a low-noise voltage amplifier is realized and applied to our detector. 12 dB of signal-to-noise ratio of the shot noise to the electric noise is obtained with 5 mW of a continuous-wave local oscillator. We analyze the frequency response and the noise characteristics of a resonant photodetector, and the theoretical model agrees with the shot noise measurement.
In an actual setup of squeezed state generation, the stability of a squeezing factor is mainly limited by the performance of the servo-control system, which is mainly influenced by the shot noise and gain of a photodetector. We present a unique transformer-coupled LC resonant amplifier as a photodetector circuit to reduce the electronic noise and increase the gain of the photodetector. As a result, we obtain a low-noise, high gain photodetector with the gain of more than 1.8×105 V/A, and the input current noise of less than 4.7 pA/Hz. By adjusting the parameters of the transformer, the quality factor Q of the resonant circuit is close to 100 in the frequency range of more than 100 MHz, which meets the requirement for weak power detection in the application of squeezed state generation.