電子情報通信学会技術研究報告. LQE, レーザ・量子エレクトロニクス

Performance improvement of optical frequency stabilized Cs optical atomic clock

Kazunari Tokuhira, Fumitaka Suzuki, Masato Yoshida, Masataka Nakazawa

Published Aug 16, 2012• 0 citations
OpenAlex

Related papers

Improvement of the frequency stability of a Raman-Ramsey Cs clock

Stéphane Guérandel, Rodolphe Boudot, Emeric de Clercq +3 more

•May 29, 2007•0 citations

Ramsey-coherent population trapping Cs atomic clock based on lin∥lin optical pumping with dispersion detection*

Pengfei Cheng, Jianwei Zhang, Lijun Wang

A Cs vapor cell-based atomic clock that uses a lin∥lin pumping scheme with dispersion detection is reported. This atomic clock shows potential for high performance because of its high contrast pumping scheme, and for miniaturization because of its simple architecture. The experimental setup and optimal operating parameters for the clock are introduced. The current fractional frequency stability is measured to be 1.3 × 10 − 12 / τ up to 20 s and reaches 3.1 × 10 − 13 at 200 s. We have thoroughly investigated the related noise sources that affect clock frequency stability at the 1 s and 100 s levels. The investigation shows that the laser frequency noise limits the clock frequency stability significantly. The clock performance can be further improved by technically upgrading the laser frequency stabilization setup.

Chinese Physics B•Jul 1, 2019•9 citations

Research on Atomic Phase Feedback in Pulsed Optically Pumped Atomic Clocks

Gongxun Dong, 林锦达 Lin Jinda, 张 松 Zhang Song +2 more

Acta Optica Sinica•Jan 1, 2017•1 citation

Beyond one-second laser coherence via active optical atomic clock

Zhuang, Chen

European Frequency and Time Forum•Jan 1, 2006•5 citations

Dual-Faraday-laser-pumped cesium beam clock with $7.7\times 10^{-13}/\sqrtτ$ frequency stability

Xiaomin Qin, Suyang Wei, Haijun Chen +8 more

Compact cesium beam clocks are major frequency references for deployable timing systems. However, further improvement of their short-term frequency stability is limited by the clock signal-to-noise ratio (SNR). Although two-laser optical pumping can increase the effective atomic utilization, the achievable clock SNR has long been limited by laser-induced frequency-to-amplitude noise conversion. Here, we demonstrate a compact dual-Faraday-laser-pumped (DFP) Cs beam clock enabled by a low-frequency-noise atom-referenced laser architecture. The intracavity Faraday anomalous dispersion optical filter provides inherent alignment to the Cs D$_2$ resonances, while modulation transfer spectroscopy offers suppressed frequency noise and drift. The resulting laser system supports robust turnkey operation with a Lorentzian linewidth of 2.12 kHz. The DFP Cs clock achieves a clock SNR of 46,365 in a 1-Hz bandwidth and a fractional Allan deviation of $7.7\times 10^{-13}/\sqrtτ$ , with Hadamard deviation reaching $7.7\times 10^{-15}$ at 10,000 s. This work pushes the fractional frequency stability of a compact Cs beam clock into the $10^{-13}/\sqrtτ$ regime, providing a pathway toward high-performance Cs frequency references for field-deployable precision timing, navigation, and synchronization.

physics.atom-phCross-listedarXiv:2608.06169•Aug 7, 2026

The development of active optical clock

Jia Zhang, Tiantian Shi, Jianxiang Miao +1 more

The atomic clocks, whether operating at optical or microwave region, can be divided into two categories according to their working mode, namely the passive clocks and active clocks. The passive clocks, whose standard frequency is locked to an ultra-narrow atomic spectral line, such as laser cooled Cs beam or lattice trapped Sr atoms, depend on the spontaneous emission line. On the contrary, the active clocks, in which the atoms are used as the gain medium, are based on the stimulated emission radiation, their spectrum can be directly used as the frequency standard. Up to now, the active hydrogen maser has been the most stable microwave atomic clocks. Also, the Sr superradiant active atomic clock is prospects for a millihertz-linewidth laser. Moreover, the optical clocks are expected to surpass the performance of microwave clocks both in stability and uncertainty, since their higher working frequency. The active optical clock has the potential to improve the stability of the best clocks by 2 orders of magnitude. In this work, we introduce the development of active optical clocks, and their types is classified according to the energy-level structure of atoms for stimulated radiation.

AAPPS bulletin•Apr 24, 2023•21 citations
A Cs vapor cell-based atomic clock that uses a lin∥lin pumping scheme with dispersion detection is reported. This atomic clock shows potential for high performance because of its high contrast pumping scheme, and for miniaturization because of its simple architecture. The experimental setup and optimal operating parameters for the clock are introduced. The current fractional frequency stability is measured to be 1.3 × 10 − 12 / τ up to 20 s and reaches 3.1 × 10 − 13 at 200 s. We have thoroughly investigated the related noise sources that affect clock frequency stability at the 1 s and 100 s levels. The investigation shows that the laser frequency noise limits the clock frequency stability significantly. The clock performance can be further improved by technically upgrading the laser frequency stabilization setup.
Dual-Faraday-laser-pumped cesium beam clock with 7.7×10−13/τ7.7\times 10^{-13}/\sqrtτ7.7×10−13/τ​ frequency stability
Compact cesium beam clocks are major frequency references for deployable timing systems. However, further improvement of their short-term frequency stability is limited by the clock signal-to-noise ratio (SNR). Although two-laser optical pumping can increase the effective atomic utilization, the achievable clock SNR has long been limited by laser-induced frequency-to-amplitude noise conversion. Here, we demonstrate a compact dual-Faraday-laser-pumped (DFP) Cs beam clock enabled by a low-frequency-noise atom-referenced laser architecture. The intracavity Faraday anomalous dispersion optical filter provides inherent alignment to the Cs D2_22​ resonances, while modulation transfer spectroscopy offers suppressed frequency noise and drift. The resulting laser system supports robust turnkey operation with a Lorentzian linewidth of 2.12 kHz. The DFP Cs clock achieves a clock SNR of 46,365 in a 1-Hz bandwidth and a fractional Allan deviation of 7.7×10−13/τ7.7\times 10^{-13}/\sqrtτ7.7×10−13/τ​ , with Hadamard deviation reaching 7.7×10−157.7\times 10^{-15}7.7×10−15 at 10,000 s. This work pushes the fractional frequency stability of a compact Cs beam clock into the 10−13/τ10^{-13}/\sqrtτ10−13/τ​ regime, providing a pathway toward high-performance Cs frequency references for field-deployable precision timing, navigation, and synchronization.
The atomic clocks, whether operating at optical or microwave region, can be divided into two categories according to their working mode, namely the passive clocks and active clocks. The passive clocks, whose standard frequency is locked to an ultra-narrow atomic spectral line, such as laser cooled Cs beam or lattice trapped Sr atoms, depend on the spontaneous emission line. On the contrary, the active clocks, in which the atoms are used as the gain medium, are based on the stimulated emission radiation, their spectrum can be directly used as the frequency standard. Up to now, the active hydrogen maser has been the most stable microwave atomic clocks. Also, the Sr superradiant active atomic clock is prospects for a millihertz-linewidth laser. Moreover, the optical clocks are expected to surpass the performance of microwave clocks both in stability and uncertainty, since their higher working frequency. The active optical clock has the potential to improve the stability of the best clocks by 2 orders of magnitude. In this work, we introduce the development of active optical clocks, and their types is classified according to the energy-level structure of atoms for stimulated radiation.