Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

European Frequency and Time Forum

Beyond one-second laser coherence via active optical atomic clock

Zhuang, Chen

Published Jan 1, 2006• 5 citations
OpenAlex

Related papers

Atomic coherence and novel laser systems

Guo Qin Ge

•Jan 1, 2001•0 citations

Superradiant active optical atomic clocks: motivations and current challenges

Martina Matusko, Marion Delehaye

Current state-of-the-art frequency standards are passive optical atomic clocks where the frequency of an optical resonator is stabilized to a narrow atomic transition. Passive clocks have achieved unprecedented stabilities of 6.6 × 10−19 over one hour of averaging time [1]. However, they face intrinsic limitations, particularly due to thermal and mechanical fluctuations of the local oscillator. To surpass the limitations of the passive clocks and go beyond the state-of-the-art, the idea of building active optical atomic clocks emerges. These clocks would be optical counterparts of hydrogen masers, with the emitted frequency defined by the atomic transition and therefore inherently stable against cavity instabilities. This paper discusses the latest developments and future prospects in the field of active optical atomic clocks.

arXiv:2411.03760•Journal of Physics Conference Series•Nov 1, 2024•3 citations

Research progress on active optical clocks

Jingbiao Chen, Wei Zhang

Active optical clocks, a new class of optical atomic clocks, work through stimulated emission lasing, a unique mechanism that is distinct from laser absorption spectroscopy of conventional optical clocks. With coherent weak optical feedback from a Fabry-Perot resonator operating in the bad-cavity regime, active optical clocks sustain a lasing oscillation at an atomic transition frequency. They are used directly as quantum optical frequency standards with expected stability better by about two orders of magnitude than that of the best clocks. This review starts with a simplified account of historical developments and the limitations of critical techniques in optical atomic clocks. After an introduction of the basic mechanism underlying active optical clocks, we discuss the most recent experimental results for several configurations and experimental set-ups of active optical clocks. These include those based on a 2-level atomic beam and 3-level laser-cooled trapped-atom system, those based on a 4-level atom scheme, and the Faraday active optical clock. Moreover, following the successful lasing and preliminary results on a Faraday active optical frequency standard with Faraday atomic filter using thermal Cs cell, we describe an experimental scheme of a Faraday active optical clock with a Faraday atomic filter using magic-lattice-trapped Sr atoms at the 689-nm transition, and Faraday optical clocks operating in the good-cavity regime. We conclude with a comprehensive comparison of the different active optical clocks, prospects for active Faraday optical clocks, and potential applications of active optical clocks.

Chinese Science Bulletin (Chinese Version)•Jul 1, 2015•3 citations

Optical-Transition Atomic Clock Beyond the Standard Quantum Limit

Vladan Vuletić

•Feb 12, 2021•0 citations

Laser spectroscopy and atomic coherence

Dipankar Bhattacharyya, Jyotirmoy Guha

Institute of Physics eBooks•Jan 1, 2022•0 citations

Optical atomic clocks and the quest for ultrastable lasers

F. Riehle

Optical atomic clocks with fractional uncertainties around and below 10−17 [1] and fractional instabilities at one second interrogation time of below 10−15 [2] have outperformed the best microwave clocks like the cesium atomic clock. In optical atomic clocks a highly stable laser is used to interrogate optical transitions in laser-cooled atoms, ions, or molecules. The increase in accuracy and stability of the optical atomic clocks results from the increased line quality factor Q= ν/Δν given by the five orders of magnitude higher frequency of optical transitions as compared to the transition relevant in the microwave domain. To utilize this potential it is furthermore necessary to realize a suitable narrow linewidth of the interrogated line. The linewidth of any optical transition is given by the different broadening mechanisms of the respective quantum transition relevant for particular interrogation process as well as by the coherence properties of the interrogating laser.

Frontiers in Optics•Jan 1, 2013•1 citation
Current state-of-the-art frequency standards are passive optical atomic clocks where the frequency of an optical resonator is stabilized to a narrow atomic transition. Passive clocks have achieved unprecedented stabilities of 6.6 × 10−19 over one hour of averaging time [1]. However, they face intrinsic limitations, particularly due to thermal and mechanical fluctuations of the local oscillator. To surpass the limitations of the passive clocks and go beyond the state-of-the-art, the idea of building active optical atomic clocks emerges. These clocks would be optical counterparts of hydrogen masers, with the emitted frequency defined by the atomic transition and therefore inherently stable against cavity instabilities. This paper discusses the latest developments and future prospects in the field of active optical atomic clocks.
Active optical clocks, a new class of optical atomic clocks, work through stimulated emission lasing, a unique mechanism that is distinct from laser absorption spectroscopy of conventional optical clocks. With coherent weak optical feedback from a Fabry-Perot resonator operating in the bad-cavity regime, active optical clocks sustain a lasing oscillation at an atomic transition frequency. They are used directly as quantum optical frequency standards with expected stability better by about two orders of magnitude than that of the best clocks. This review starts with a simplified account of historical developments and the limitations of critical techniques in optical atomic clocks. After an introduction of the basic mechanism underlying active optical clocks, we discuss the most recent experimental results for several configurations and experimental set-ups of active optical clocks. These include those based on a 2-level atomic beam and 3-level laser-cooled trapped-atom system, those based on a 4-level atom scheme, and the Faraday active optical clock. Moreover, following the successful lasing and preliminary results on a Faraday active optical frequency standard with Faraday atomic filter using thermal Cs cell, we describe an experimental scheme of a Faraday active optical clock with a Faraday atomic filter using magic-lattice-trapped Sr atoms at the 689-nm transition, and Faraday optical clocks operating in the good-cavity regime. We conclude with a comprehensive comparison of the different active optical clocks, prospects for active Faraday optical clocks, and potential applications of active optical clocks.
Optical atomic clocks with fractional uncertainties around and below 10−17 [1] and fractional instabilities at one second interrogation time of below 10−15 [2] have outperformed the best microwave clocks like the cesium atomic clock. In optical atomic clocks a highly stable laser is used to interrogate optical transitions in laser-cooled atoms, ions, or molecules. The increase in accuracy and stability of the optical atomic clocks results from the increased line quality factor Q= ν/Δν given by the five orders of magnitude higher frequency of optical transitions as compared to the transition relevant in the microwave domain. To utilize this potential it is furthermore necessary to realize a suitable narrow linewidth of the interrogated line. The linewidth of any optical transition is given by the different broadening mechanisms of the respective quantum transition relevant for particular interrogation process as well as by the coherence properties of the interrogating laser.