Chinese Physics B

Ramsey-coherent population trapping Cs atomic clock based on lin∥lin optical pumping with dispersion detection*

Pengfei Cheng, Jianwei Zhang, Lijun Wang

Published Jul 1, 2019• 9 citations
Publisher

Abstract

A Cs vapor cell-based atomic clock that uses a lin∥lin pumping scheme with dispersion detection is reported. This atomic clock shows potential for high performance because of its high contrast pumping scheme, and for miniaturization because of its simple architecture. The experimental setup and optimal operating parameters for the clock are introduced. The current fractional frequency stability is measured to be 1.3 × 10 − 12 / τ up to 20 s and reaches 3.1 × 10 − 13 at 200 s. We have thoroughly investigated the related noise sources that affect clock frequency stability at the 1 s and 100 s levels. The investigation shows that the laser frequency noise limits the clock frequency stability significantly. The clock performance can be further improved by technically upgrading the laser frequency stabilization setup.

DOI
10.1088/1674-1056/28/7/070601

Related papers

A high-performance Raman-Ramsey Cs vapor cell atomic clock

Moustafa Abdel Hafiz, Grégoire Coget, Peter Yun +3 more

We demonstrate a high-performance coherent-population-trapping (CPT) Cs vapor cell atomic clock using the push-pull optical pumping technique in the pulsed regime, allowing the detection of high-contrast and narrow Ramsey-CPT fringes. The impact of several experimental parameters onto the clock resonance and short-term fractional frequency stability, including the laser power, the cell temperature, and the Ramsey sequence parameters, has been investigated. We observe and explain the existence of a slight dependence on laser power of the central Ramsey-CPT fringe line-width in the pulsed regime. We report also that the central fringe line-width is commonly narrower than the expected Ramsey line-width given by 1/(2TR), with TR the free-evolution time, for short values of TR. The clock demonstrates a short-term fractional frequency stability at the level of 2.3×10−13 τ−1/2 up to 100 s averaging time, mainly limited by the laser amplitude modulation noise. Comparable performances are obtained in the conventional continuous wave regime, with the use of an additional laser power stabilization setup. The pulsed interaction allows to reduce significantly the clock frequency sensitivity to laser power variations, especially for high values of TR. This pulsed CPT clock, ranking among the best microwave vapor cell atomic frequency standards, could find applications in telecommunication, instrumentation, defense or satellite-based navigation systems.

arXiv:1703.04720•Journal of Applied Physics•Mar 10, 2017•86 citations

A CPT-based Cs vapor cell atomic clock with a short-term fractional frequency stability of 3 x 10-13τ-1/2

Moustafa Abdel Hafiz, Xiaochi Liu, Stéphane Guérandel +2 more

This article reports on the development and short-term fractional frequency stability of a continuous-regime (CW) Cs vapor cell atomic clock based on coherent population trapping (CPT). The push-pull optical pumping technique is used to increase the number of atoms that participate to the clock transition, yielding a typical CPT resonance contrast of 25% for a CPT linewidth of about 450 Hz. The clock short-term fractional frequency stability is measured to be 3 x 10 -13 τ -1/2 up to 100 seconds averaging time, in correct agreement with the signal-to-noise ratio limit. The mid-term frequency stability results are currently mainly limited by laser power effects. The detection of high-contrast narrow Raman-Ramsey fringes is demonstrated with this setup by making the atoms interact with a light pulse sequence.

Journal of Physics Conference Series•Jun 1, 2016•6 citations

A coherent population trapping Cs vapor cell atomic clock based on push-pull optical pumping

Moustafa Abdel Hafiz, Rodolphe Boudot

This article reports on the characterization of a compact coherent-population-trapping (CPT) Cs vapor cell atomic clock using the push-pull optical pumping technique. This method allows to detect high-contrast CPT resonances on the 0-0 magnetic-field insensitive clock transition. The clock short-term fractional frequency stability is measured to be 3×10−13 τ−1/2 up to 100 s averaging time, in correct agreement with the signal-to-noise ratio limit. These results are among the best performances ever reported for a CPT-based clock. The noise budget is detailed. A preliminary study is reported to evaluate limitations to the clock mid-term frequency stability. The clock performances are found to be presently mainly limited in the mid-term by laser power effects.

Journal of Applied Physics•Sep 28, 2015•49 citations

Feasibility toward a compact high performance coherent population trapping clock

Peter Yun, François Tricot, Emeric de Clercq +4 more

We demonstrate a vapor-cell atomic-clock prototype based on a continuous-wave interrogation and double-modulation coherent population trapping (DM-CPT) technique. The DM-CPT technique uses a synchronous modulation of polarization and the relative phase of a bichromatic laser beam in order to increase the number of atoms trapped in a dark state, i.e., a nonabsorbing state. The narrow resonance, observed in the transmission of a Cs vapor cell, is used as a narrow frequency discriminator in an atomic clock. A detailed characterization of the CPT resonance versus numerous parameters is reported. A short-term fractional-frequency stability of 3.2×10−13τ−1/2 up to a 100-s averaging time is measured. These performances are more than one order of magnitude better than industrial Rb clocks and are comparable to those of the best laboratory-prototype vapor-cell clocks. The noise-budget analysis shows that the short- and midterm frequency stability is mainly limited by the power fluctuations of the microwave used to generate the bichromatic laser. These preliminary results demonstrate that the DM-CPT technique is well suited for the development of a high-performance atomic clock, with the potential compact and robust setup due to its linear architecture. This clock could find future applications in industry, telecommunications, instrumentation, or global navigation satellite systems.

•Apr 14, 2019•0 citations

Investigation of Ramsey spectroscopy in a lin-par-lin Ramsey coherent population trapping clock with dispersion detection

Xiaolin Sun, Jianwei Zhang, Pengfei Cheng +3 more

Rb clock using a dispersion detection technique has a promising performance. We theoretically and experimentally investigate the signal-to-noise ratio of the Ramsey spectrum signal by varying the relative angle of the polarizer and analyzer as well as the magnetic field. Based on the experimental results, the optimized relative angle and magnetic field are determined. This kind of atomic clock is attractive for the development of compact, high performance vapor clock based on CPT.

Optics Express•Feb 23, 2016•15 citations

Microwave phase detection of coherent population trapping resonance in a Cs vapor cell

Michael Petersen, Moustafa Abdel Hafiz, Emeric de Clercq +1 more

We report a phase-sensitive microwave detection setup for spectroscopy of coherent population trapping (CPT) resonance in a Cs vapor cell. In this scheme, the optically carried microwave interrogation signal that interacts with atoms is detected by a fast photodiode at the cell output and is then mixed with the local oscillator microwave signal itself. This detection scheme produces at the output of the microwave mixer a dispersive CPT signal that can be directly used for correction of the local oscillator frequency onto the atomic resonance. The evolution of the dispersive CPT resonance signal with the laser power is briefly reported. With this detection scheme, we demonstrate the operation of a CPT atomic clock with a short-term fractional frequency stability of 1 × 10 − 11 at 1 s, which is in good agreement with the slope of the frequency discriminator and the residual microwave phase noise of the setup.

Journal of the Optical Society of America B•Feb 3, 2022•3 citations
A Cs vapor cell-based atomic clock that uses a lin∥lin pumping scheme with dispersion detection is reported. This atomic clock shows potential for high performance because of its high contrast pumping scheme, and for miniaturization because of its simple architecture. The experimental setup and optimal operating parameters for the clock are introduced. The current fractional frequency stability is measured to be 1.3 × 10 − 12 / τ up to 20 s and reaches 3.1 × 10 − 13 at 200 s. We have thoroughly investigated the related noise sources that affect clock frequency stability at the 1 s and 100 s levels. The investigation shows that the laser frequency noise limits the clock frequency stability significantly. The clock performance can be further improved by technically upgrading the laser frequency stabilization setup.
We demonstrate a high-performance coherent-population-trapping (CPT) Cs vapor cell atomic clock using the push-pull optical pumping technique in the pulsed regime, allowing the detection of high-contrast and narrow Ramsey-CPT fringes. The impact of several experimental parameters onto the clock resonance and short-term fractional frequency stability, including the laser power, the cell temperature, and the Ramsey sequence parameters, has been investigated. We observe and explain the existence of a slight dependence on laser power of the central Ramsey-CPT fringe line-width in the pulsed regime. We report also that the central fringe line-width is commonly narrower than the expected Ramsey line-width given by 1/(2TR), with TR the free-evolution time, for short values of TR. The clock demonstrates a short-term fractional frequency stability at the level of 2.3×10−13 τ−1/2 up to 100 s averaging time, mainly limited by the laser amplitude modulation noise. Comparable performances are obtained in the conventional continuous wave regime, with the use of an additional laser power stabilization setup. The pulsed interaction allows to reduce significantly the clock frequency sensitivity to laser power variations, especially for high values of TR. This pulsed CPT clock, ranking among the best microwave vapor cell atomic frequency standards, could find applications in telecommunication, instrumentation, defense or satellite-based navigation systems.
This article reports on the development and short-term fractional frequency stability of a continuous-regime (CW) Cs vapor cell atomic clock based on coherent population trapping (CPT). The push-pull optical pumping technique is used to increase the number of atoms that participate to the clock transition, yielding a typical CPT resonance contrast of 25% for a CPT linewidth of about 450 Hz. The clock short-term fractional frequency stability is measured to be 3 x 10 -13 τ -1/2 up to 100 seconds averaging time, in correct agreement with the signal-to-noise ratio limit. The mid-term frequency stability results are currently mainly limited by laser power effects. The detection of high-contrast narrow Raman-Ramsey fringes is demonstrated with this setup by making the atoms interact with a light pulse sequence.
This article reports on the characterization of a compact coherent-population-trapping (CPT) Cs vapor cell atomic clock using the push-pull optical pumping technique. This method allows to detect high-contrast CPT resonances on the 0-0 magnetic-field insensitive clock transition. The clock short-term fractional frequency stability is measured to be 3×10−13 τ−1/2 up to 100 s averaging time, in correct agreement with the signal-to-noise ratio limit. These results are among the best performances ever reported for a CPT-based clock. The noise budget is detailed. A preliminary study is reported to evaluate limitations to the clock mid-term frequency stability. The clock performances are found to be presently mainly limited in the mid-term by laser power effects.
We demonstrate a vapor-cell atomic-clock prototype based on a continuous-wave interrogation and double-modulation coherent population trapping (DM-CPT) technique. The DM-CPT technique uses a synchronous modulation of polarization and the relative phase of a bichromatic laser beam in order to increase the number of atoms trapped in a dark state, i.e., a nonabsorbing state. The narrow resonance, observed in the transmission of a Cs vapor cell, is used as a narrow frequency discriminator in an atomic clock. A detailed characterization of the CPT resonance versus numerous parameters is reported. A short-term fractional-frequency stability of 3.2×10−13τ−1/2 up to a 100-s averaging time is measured. These performances are more than one order of magnitude better than industrial Rb clocks and are comparable to those of the best laboratory-prototype vapor-cell clocks. The noise-budget analysis shows that the short- and midterm frequency stability is mainly limited by the power fluctuations of the microwave used to generate the bichromatic laser. These preliminary results demonstrate that the DM-CPT technique is well suited for the development of a high-performance atomic clock, with the potential compact and robust setup due to its linear architecture. This clock could find future applications in industry, telecommunications, instrumentation, or global navigation satellite systems.
We report a phase-sensitive microwave detection setup for spectroscopy of coherent population trapping (CPT) resonance in a Cs vapor cell. In this scheme, the optically carried microwave interrogation signal that interacts with atoms is detected by a fast photodiode at the cell output and is then mixed with the local oscillator microwave signal itself. This detection scheme produces at the output of the microwave mixer a dispersive CPT signal that can be directly used for correction of the local oscillator frequency onto the atomic resonance. The evolution of the dispersive CPT resonance signal with the laser power is briefly reported. With this detection scheme, we demonstrate the operation of a CPT atomic clock with a short-term fractional frequency stability of 1 × 10 − 11 at 1 s, which is in good agreement with the slope of the frequency discriminator and the residual microwave phase noise of the setup.