arXiv:1703.04720 · Journal of Applied Physics

A high-performance Raman-Ramsey Cs vapor cell atomic clock

Moustafa Abdel Hafiz, Grégoire Coget, Peter Yun, Stéphane Guérandel, Emeric de Clercq, Rodolphe Boudot

Published Mar 10, 2017• 86 citations
arXivHTMLPDF

Abstract

We demonstrate a high-performance coherent-population-trapping (CPT) Cs vapor cell atomic clock using the push-pull optical pumping technique in the pulsed regime, allowing the detection of high-contrast and narrow Ramsey-CPT fringes. The impact of several experimental parameters onto the clock resonance and short-term fractional frequency stability, including the laser power, the cell temperature, and the Ramsey sequence parameters, has been investigated. We observe and explain the existence of a slight dependence on laser power of the central Ramsey-CPT fringe line-width in the pulsed regime. We report also that the central fringe line-width is commonly narrower than the expected Ramsey line-width given by 1/(2TR), with TR the free-evolution time, for short values of TR. The clock demonstrates a short-term fractional frequency stability at the level of 2.3×10−13 τ−1/2 up to 100 s averaging time, mainly limited by the laser amplitude modulation noise. Comparable performances are obtained in the conventional continuous wave regime, with the use of an additional laser power stabilization setup. The pulsed interaction allows to reduce significantly the clock frequency sensitivity to laser power variations, especially for high values of TR. This pulsed CPT clock, ranking among the best microwave vapor cell atomic frequency standards, could find applications in telecommunication, instrumentation, defense or satellite-based navigation systems.

DOI
10.1063/1.4977955

Related papers

A CPT-based Cs vapor cell atomic clock with a short-term fractional frequency stability of 3 x 10-13τ-1/2

Moustafa Abdel Hafiz, Xiaochi Liu, Stéphane Guérandel +2 more

This article reports on the development and short-term fractional frequency stability of a continuous-regime (CW) Cs vapor cell atomic clock based on coherent population trapping (CPT). The push-pull optical pumping technique is used to increase the number of atoms that participate to the clock transition, yielding a typical CPT resonance contrast of 25% for a CPT linewidth of about 450 Hz. The clock short-term fractional frequency stability is measured to be 3 x 10 -13 τ -1/2 up to 100 seconds averaging time, in correct agreement with the signal-to-noise ratio limit. The mid-term frequency stability results are currently mainly limited by laser power effects. The detection of high-contrast narrow Raman-Ramsey fringes is demonstrated with this setup by making the atoms interact with a light pulse sequence.

Journal of Physics Conference Series•Jun 1, 2016•6 citations

A coherent population trapping Cs vapor cell atomic clock based on push-pull optical pumping

Moustafa Abdel Hafiz, Rodolphe Boudot

This article reports on the characterization of a compact coherent-population-trapping (CPT) Cs vapor cell atomic clock using the push-pull optical pumping technique. This method allows to detect high-contrast CPT resonances on the 0-0 magnetic-field insensitive clock transition. The clock short-term fractional frequency stability is measured to be 3×10−13 τ−1/2 up to 100 s averaging time, in correct agreement with the signal-to-noise ratio limit. These results are among the best performances ever reported for a CPT-based clock. The noise budget is detailed. A preliminary study is reported to evaluate limitations to the clock mid-term frequency stability. The clock performances are found to be presently mainly limited in the mid-term by laser power effects.

Journal of Applied Physics•Sep 28, 2015•49 citations

Feasibility toward a compact high performance coherent population trapping clock

Peter Yun, François Tricot, Emeric de Clercq +4 more

We demonstrate a vapor-cell atomic-clock prototype based on a continuous-wave interrogation and double-modulation coherent population trapping (DM-CPT) technique. The DM-CPT technique uses a synchronous modulation of polarization and the relative phase of a bichromatic laser beam in order to increase the number of atoms trapped in a dark state, i.e., a nonabsorbing state. The narrow resonance, observed in the transmission of a Cs vapor cell, is used as a narrow frequency discriminator in an atomic clock. A detailed characterization of the CPT resonance versus numerous parameters is reported. A short-term fractional-frequency stability of 3.2×10−13τ−1/2 up to a 100-s averaging time is measured. These performances are more than one order of magnitude better than industrial Rb clocks and are comparable to those of the best laboratory-prototype vapor-cell clocks. The noise-budget analysis shows that the short- and midterm frequency stability is mainly limited by the power fluctuations of the microwave used to generate the bichromatic laser. These preliminary results demonstrate that the DM-CPT technique is well suited for the development of a high-performance atomic clock, with the potential compact and robust setup due to its linear architecture. This clock could find future applications in industry, telecommunications, instrumentation, or global navigation satellite systems.

•Apr 14, 2019•0 citations

Ramsey spectroscopy of high-contrast CPT resonances with push-pull optical pumping in Cs vapor

Xiaochi Liu, Jean-Marc Mérolla, Stéphane Guérandel +2 more

We report on the detection of high-contrast and narrow Coherent Population Trapping (CPT) Ramsey fringes in a Cs vapor cell using a simple-architecture laser system. The latter allows the combination of push-pull optical pumping (PPOP) and a temporal Ramsey-like pulsed interrogation. An originality of the optics package is the use of a single Mach-Zehnder electro-optic modulator (MZ EOM) both for optical sidebands generation and light switch for pulsed interaction. Typical Ramsey fringes with a linewidth of 166 Hz and a contrast of 33 % are detected in a cm-scale buffer-gas filled Cs vapor cell. This technique could be interesting for the development of high-performance and low power consumption compact vapor cell clocks based on CPT.

arXiv:1305.7321•Optics Express•May 14, 2013•50 citations

Raman–Ramsey Interaction for Coherent Population Trapping Cs Clock

Stéphane Guérandel, T. Zanon-Willette, N. Castagna +4 more

A gas cell atomic frequency standard based on coherent population trapping (CPT) with Ramsey interrogation pulses is developed. The clock resonance is detected in a Cs cell with buffer gas using two phase-locked diode lasers tuned to the D1 line. A preliminary short-term stability of$3.5 \times 10^{-12}t^{-1/2}$is reported. The CPT specificity allows a new interrogation–detection sequence, i.e., the continuous pulse train, which, with phase modulation, could lead to better short-term stability compared to usual continuous CPT clocks. The parameters optimizing the stability include a high Rabi frequency, a very short measurement time, and an interrogation time equal to the lifetime of the hyperfine coherence.

IEEE Transactions on Instrumentation and Measurement•Mar 16, 2007•43 citations

Symmetric autobalanced Ramsey interrogation for high-performance coherent-population-trapping vapor-cell atomic clock

Moustafa Abdel Hafiz, Grégoire Coget, M. Petersen +4 more

We report a high-performance pulsed coherent population trapping (CPT) Cs cell atomic clock using the implementation of a symmetric auto-balanced Ramsey (SABR) interrogation sequence. The latter method is found to reduce the light-power induced frequency shift by an order of magnitude compared to a previous experiment using a simple auto-balanced Ramsey interrogation. The contribution of this shift to the clock frequency stability is now rejected in the 10−16 range at 104 s averaging time. Additional tricks, including a compensation method to reduce the laser amplitude noise contribution and the generation of novel error signals for local oscillator frequency and phase correction, have been implemented using a FPGA-based digital electronics board in order to improve the clock short-term stability by a of factor 2. The Allan deviation of the SABR-CPT clock, extracted from a selected 3 × 104 s-long dataset, is 2 × 10−13 τ−1∕2 and averages down to the level of 2.5 × 10−15 at 104 s. These results are encouraging to stimulate the development of hot cell CPT-based clocks for industrial, scientific, and instrumentation applications.

Applied Physics Letters•Jun 11, 2018•72 citations
We demonstrate a high-performance coherent-population-trapping (CPT) Cs vapor cell atomic clock using the push-pull optical pumping technique in the pulsed regime, allowing the detection of high-contrast and narrow Ramsey-CPT fringes. The impact of several experimental parameters onto the clock resonance and short-term fractional frequency stability, including the laser power, the cell temperature, and the Ramsey sequence parameters, has been investigated. We observe and explain the existence of a slight dependence on laser power of the central Ramsey-CPT fringe line-width in the pulsed regime. We report also that the central fringe line-width is commonly narrower than the expected Ramsey line-width given by 1/(2TR), with TR the free-evolution time, for short values of TR. The clock demonstrates a short-term fractional frequency stability at the level of 2.3×10−13 τ−1/2 up to 100 s averaging time, mainly limited by the laser amplitude modulation noise. Comparable performances are obtained in the conventional continuous wave regime, with the use of an additional laser power stabilization setup. The pulsed interaction allows to reduce significantly the clock frequency sensitivity to laser power variations, especially for high values of TR. This pulsed CPT clock, ranking among the best microwave vapor cell atomic frequency standards, could find applications in telecommunication, instrumentation, defense or satellite-based navigation systems.
This article reports on the development and short-term fractional frequency stability of a continuous-regime (CW) Cs vapor cell atomic clock based on coherent population trapping (CPT). The push-pull optical pumping technique is used to increase the number of atoms that participate to the clock transition, yielding a typical CPT resonance contrast of 25% for a CPT linewidth of about 450 Hz. The clock short-term fractional frequency stability is measured to be 3 x 10 -13 τ -1/2 up to 100 seconds averaging time, in correct agreement with the signal-to-noise ratio limit. The mid-term frequency stability results are currently mainly limited by laser power effects. The detection of high-contrast narrow Raman-Ramsey fringes is demonstrated with this setup by making the atoms interact with a light pulse sequence.
This article reports on the characterization of a compact coherent-population-trapping (CPT) Cs vapor cell atomic clock using the push-pull optical pumping technique. This method allows to detect high-contrast CPT resonances on the 0-0 magnetic-field insensitive clock transition. The clock short-term fractional frequency stability is measured to be 3×10−13 τ−1/2 up to 100 s averaging time, in correct agreement with the signal-to-noise ratio limit. These results are among the best performances ever reported for a CPT-based clock. The noise budget is detailed. A preliminary study is reported to evaluate limitations to the clock mid-term frequency stability. The clock performances are found to be presently mainly limited in the mid-term by laser power effects.
We demonstrate a vapor-cell atomic-clock prototype based on a continuous-wave interrogation and double-modulation coherent population trapping (DM-CPT) technique. The DM-CPT technique uses a synchronous modulation of polarization and the relative phase of a bichromatic laser beam in order to increase the number of atoms trapped in a dark state, i.e., a nonabsorbing state. The narrow resonance, observed in the transmission of a Cs vapor cell, is used as a narrow frequency discriminator in an atomic clock. A detailed characterization of the CPT resonance versus numerous parameters is reported. A short-term fractional-frequency stability of 3.2×10−13τ−1/2 up to a 100-s averaging time is measured. These performances are more than one order of magnitude better than industrial Rb clocks and are comparable to those of the best laboratory-prototype vapor-cell clocks. The noise-budget analysis shows that the short- and midterm frequency stability is mainly limited by the power fluctuations of the microwave used to generate the bichromatic laser. These preliminary results demonstrate that the DM-CPT technique is well suited for the development of a high-performance atomic clock, with the potential compact and robust setup due to its linear architecture. This clock could find future applications in industry, telecommunications, instrumentation, or global navigation satellite systems.
We report on the detection of high-contrast and narrow Coherent Population Trapping (CPT) Ramsey fringes in a Cs vapor cell using a simple-architecture laser system. The latter allows the combination of push-pull optical pumping (PPOP) and a temporal Ramsey-like pulsed interrogation. An originality of the optics package is the use of a single Mach-Zehnder electro-optic modulator (MZ EOM) both for optical sidebands generation and light switch for pulsed interaction. Typical Ramsey fringes with a linewidth of 166 Hz and a contrast of 33 % are detected in a cm-scale buffer-gas filled Cs vapor cell. This technique could be interesting for the development of high-performance and low power consumption compact vapor cell clocks based on CPT.
A gas cell atomic frequency standard based on coherent population trapping (CPT) with Ramsey interrogation pulses is developed. The clock resonance is detected in a Cs cell with buffer gas using two phase-locked diode lasers tuned to the D1 line. A preliminary short-term stability of3.5×10−12t−1/23.5 \times 10^{-12}t^{-1/2}3.5×10−12t−1/2is reported. The CPT specificity allows a new interrogation–detection sequence, i.e., the continuous pulse train, which, with phase modulation, could lead to better short-term stability compared to usual continuous CPT clocks. The parameters optimizing the stability include a high Rabi frequency, a very short measurement time, and an interrogation time equal to the lifetime of the hyperfine coherence.
We report a high-performance pulsed coherent population trapping (CPT) Cs cell atomic clock using the implementation of a symmetric auto-balanced Ramsey (SABR) interrogation sequence. The latter method is found to reduce the light-power induced frequency shift by an order of magnitude compared to a previous experiment using a simple auto-balanced Ramsey interrogation. The contribution of this shift to the clock frequency stability is now rejected in the 10−16 range at 104 s averaging time. Additional tricks, including a compensation method to reduce the laser amplitude noise contribution and the generation of novel error signals for local oscillator frequency and phase correction, have been implemented using a FPGA-based digital electronics board in order to improve the clock short-term stability by a of factor 2. The Allan deviation of the SABR-CPT clock, extracted from a selected 3 × 104 s-long dataset, is 2 × 10−13 τ−1∕2 and averages down to the level of 2.5 × 10−15 at 104 s. These results are encouraging to stimulate the development of hot cell CPT-based clocks for industrial, scientific, and instrumentation applications.