Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Improvement of the frequency stability of a Raman-Ramsey Cs clock

Stéphane Guérandel, Rodolphe Boudot, Emeric de Clercq, N. Castagna, N. Dimarcq, André Clairon

Published May 29, 2007• 0 citations
OpenAlex

Related papers

Some technical aspects of a Raman-Ramsey Cs clock

Rodolphe Boudot, Stéphane Guérandel, Emeric de Clercq +3 more

•Apr 22, 2008•0 citations

Performance improvement of optical frequency stabilized Cs optical atomic clock

Kazunari Tokuhira, Fumitaka Suzuki, Masato Yoshida +1 more

電子情報通信学会技術研究報告. LQE, レーザ・量子エレクトロニクス•Aug 16, 2012•0 citations

RAMAN-RAMSEY Cs CELL ATOMIC CLOCK

Rodolphe Boudot, Stéphane Guérandel, N. Castagna +4 more

A Raman-Ramsey Cs cell atomic clock based on Coherent Population Trapping is studied. High contrasts and narrow width Ramsey fringes are achieved by combining an original double-lambda scheme and a pulsed interrogation technique. The pulsed method allows a strong reduction of the light shift effect and avoids the power broadening. Removing a drift attributed to the cell, the clock frequency stability has been measured to be 7 × 10 -13 τ -1/2 .

Symposium on Frequency Standards and Metrology•May 1, 2009•0 citations

Time sequence optimization and optical detuning effects in a Raman-Ramsey frequency standard

T. Zanon-Willette, Stéphane Guérandel, Emeric de Clercq +3 more

•Mar 21, 2005•0 citations

Raman–Ramsey Interaction for Coherent Population Trapping Cs Clock

Stéphane Guérandel, T. Zanon-Willette, N. Castagna +4 more

A gas cell atomic frequency standard based on coherent population trapping (CPT) with Ramsey interrogation pulses is developed. The clock resonance is detected in a Cs cell with buffer gas using two phase-locked diode lasers tuned to the D1 line. A preliminary short-term stability of$3.5 \times 10^{-12}t^{-1/2}$is reported. The CPT specificity allows a new interrogation–detection sequence, i.e., the continuous pulse train, which, with phase modulation, could lead to better short-term stability compared to usual continuous CPT clocks. The parameters optimizing the stability include a high Rabi frequency, a very short measurement time, and an interrogation time equal to the lifetime of the hyperfine coherence.

IEEE Transactions on Instrumentation and Measurement•Mar 16, 2007•48 citations

Two-step pulse observation for Raman–Ramsey coherent population trapping atomic clocks

Yuichiro Yano, Shigeyoshi Goka, Masatoshi Kajita

We propose a two-step pulse observation method to enhance the frequency stability of coherent population trapping (CPT) atomic clocks. The proposed method is a Raman–Ramsey scheme with low light intensity at resonance observation and provides a Ramsey-CPT resonance with both reduced frequency sensitivity to the light intensity and a high signal-to-noise ratio by reducing the repumping into a steady dark state. The resonance characteristics were calculated using density matrix analysis of a Λ-type three-level system that was modeled on the 133 Cs D 1 line, and the characteristics were also measured using a vertical-cavity surface-emitting laser and a Cs vapor cell.

arXiv:1411.3779•Applied Physics Express•Dec 11, 2014•9 citations
A gas cell atomic frequency standard based on coherent population trapping (CPT) with Ramsey interrogation pulses is developed. The clock resonance is detected in a Cs cell with buffer gas using two phase-locked diode lasers tuned to the D1 line. A preliminary short-term stability of3.5×10−12t−1/23.5 \times 10^{-12}t^{-1/2}3.5×10−12t−1/2is reported. The CPT specificity allows a new interrogation–detection sequence, i.e., the continuous pulse train, which, with phase modulation, could lead to better short-term stability compared to usual continuous CPT clocks. The parameters optimizing the stability include a high Rabi frequency, a very short measurement time, and an interrogation time equal to the lifetime of the hyperfine coherence.
We propose a two-step pulse observation method to enhance the frequency stability of coherent population trapping (CPT) atomic clocks. The proposed method is a Raman–Ramsey scheme with low light intensity at resonance observation and provides a Ramsey-CPT resonance with both reduced frequency sensitivity to the light intensity and a high signal-to-noise ratio by reducing the repumping into a steady dark state. The resonance characteristics were calculated using density matrix analysis of a Λ-type three-level system that was modeled on the 133 Cs D 1 line, and the characteristics were also measured using a vertical-cavity surface-emitting laser and a Cs vapor cell.