Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Symposium on Frequency Standards and Metrology

RAMAN-RAMSEY Cs CELL ATOMIC CLOCK

Rodolphe Boudot, Stéphane Guérandel, N. Castagna, Olga Kozlova, Emeric de Clercq, N. Dimarcq, Andr  Clairon

Published May 1, 2009• 0 citations
Publisher

Abstract

A Raman-Ramsey Cs cell atomic clock based on Coherent Population Trapping is studied. High contrasts and narrow width Ramsey fringes are achieved by combining an original double-lambda scheme and a pulsed interrogation technique. The pulsed method allows a strong reduction of the light shift effect and avoids the power broadening. Removing a drift attributed to the cell, the clock frequency stability has been measured to be 7 × 10 -13 τ -1/2 .

DOI
10.1142/9789812838223_0045

Related papers

A high-performance Raman-Ramsey Cs vapor cell atomic clock

Moustafa Abdel Hafiz, Grégoire Coget, Peter Yun +3 more

We demonstrate a high-performance coherent-population-trapping (CPT) Cs vapor cell atomic clock using the push-pull optical pumping technique in the pulsed regime, allowing the detection of high-contrast and narrow Ramsey-CPT fringes. The impact of several experimental parameters onto the clock resonance and short-term fractional frequency stability, including the laser power, the cell temperature, and the Ramsey sequence parameters, has been investigated. We observe and explain the existence of a slight dependence on laser power of the central Ramsey-CPT fringe line-width in the pulsed regime. We report also that the central fringe line-width is commonly narrower than the expected Ramsey line-width given by 1/(2TR), with TR the free-evolution time, for short values of TR. The clock demonstrates a short-term fractional frequency stability at the level of 2.3×10−13 τ−1/2 up to 100 s averaging time, mainly limited by the laser amplitude modulation noise. Comparable performances are obtained in the conventional continuous wave regime, with the use of an additional laser power stabilization setup. The pulsed interaction allows to reduce significantly the clock frequency sensitivity to laser power variations, especially for high values of TR. This pulsed CPT clock, ranking among the best microwave vapor cell atomic frequency standards, could find applications in telecommunication, instrumentation, defense or satellite-based navigation systems.

arXiv:1703.04720•Journal of Applied Physics•Mar 10, 2017•101 citations

A CPT-based Cs vapor cell atomic clock with a short-term fractional frequency stability of 3 x 10-13τ-1/2

Moustafa Abdel Hafiz, Xiaochi Liu, Stéphane Guérandel +2 more

This article reports on the development and short-term fractional frequency stability of a continuous-regime (CW) Cs vapor cell atomic clock based on coherent population trapping (CPT). The push-pull optical pumping technique is used to increase the number of atoms that participate to the clock transition, yielding a typical CPT resonance contrast of 25% for a CPT linewidth of about 450 Hz. The clock short-term fractional frequency stability is measured to be 3 x 10 -13 τ -1/2 up to 100 seconds averaging time, in correct agreement with the signal-to-noise ratio limit. The mid-term frequency stability results are currently mainly limited by laser power effects. The detection of high-contrast narrow Raman-Ramsey fringes is demonstrated with this setup by making the atoms interact with a light pulse sequence.

Journal of Physics Conference Series•Jun 1, 2016•9 citations

Two-step pulse observation for Raman–Ramsey coherent population trapping atomic clocks

Yuichiro Yano, Shigeyoshi Goka, Masatoshi Kajita

We propose a two-step pulse observation method to enhance the frequency stability of coherent population trapping (CPT) atomic clocks. The proposed method is a Raman–Ramsey scheme with low light intensity at resonance observation and provides a Ramsey-CPT resonance with both reduced frequency sensitivity to the light intensity and a high signal-to-noise ratio by reducing the repumping into a steady dark state. The resonance characteristics were calculated using density matrix analysis of a Λ-type three-level system that was modeled on the 133 Cs D 1 line, and the characteristics were also measured using a vertical-cavity surface-emitting laser and a Cs vapor cell.

arXiv:1411.3779•Applied Physics Express•Dec 11, 2014•9 citations

Pulsed-CPT Cs-Ne microcell atomic clock with frequency stability below 2 × 10 −12 at 10 5 s

Clément Carlé, Moustafa Abdel Hafiz, Shervin Keshavarzi +3 more

We report on the mid-term stability progress of a table-top coherent population trapping (CPT) microcell atomic clock, previously limited by light-shift effects and variations of the cell's inner atmosphere. The light-shift contribution is now mitigated through the use of a pulsed symmetric auto-balanced Ramsey (SABR) interrogation technique, combined with setup temperature, laser power, and microwave power stabilization. In addition, Ne buffer gas pressure variations in the cell are now greatly reduced through the use of a micro-fabricated cell built with low permeation alumino-silicate glass (ASG) windows. Combining these approaches, the clock Allan deviation is measured to be 1.4 × 10 −12 at 10 5 s. This stability level at one day is competitive with the best current microwave microcell-based atomic clocks.

Optics Express•Feb 17, 2023•36 citations

Symmetric autobalanced Ramsey interrogation for high-performance coherent-population-trapping vapor-cell atomic clock

Moustafa Abdel Hafiz, Grégoire Coget, M. Petersen +4 more

We report a high-performance pulsed coherent population trapping (CPT) Cs cell atomic clock using the implementation of a symmetric auto-balanced Ramsey (SABR) interrogation sequence. The latter method is found to reduce the light-power induced frequency shift by an order of magnitude compared to a previous experiment using a simple auto-balanced Ramsey interrogation. The contribution of this shift to the clock frequency stability is now rejected in the 10−16 range at 104 s averaging time. Additional tricks, including a compensation method to reduce the laser amplitude noise contribution and the generation of novel error signals for local oscillator frequency and phase correction, have been implemented using a FPGA-based digital electronics board in order to improve the clock short-term stability by a of factor 2. The Allan deviation of the SABR-CPT clock, extracted from a selected 3 × 104 s-long dataset, is 2 × 10−13 τ−1∕2 and averages down to the level of 2.5 × 10−15 at 104 s. These results are encouraging to stimulate the development of hot cell CPT-based clocks for industrial, scientific, and instrumentation applications.

Applied Physics Letters•Jun 11, 2018•84 citations

High Contrast Ramsey Fringes with Coherent-Population-Trapping Pulses in a Double Lambda Atomic System

T. Zanon-Willette, Stéphane Guérandel, Emeric de Clercq +3 more

We report the observation of Raman-Ramsey fringes using a double lambda scheme creating coherent population trapping in an atomic ensemble combined with pulsed optical radiations. The observation was made in a Cs vapor mixed with N2 buffer gas in a closed cell. The double lambda scheme is created with lin perpendicular lin polarized laser beams leading to higher contrast than the usual simple lambda scheme. The pulsed trapping technique leads to narrow fringe widths scaling as 1/(2T) with high contrasts which are no longer limited by the saturation effect. This technique operates in a different way from the classical Ramsey sequence: the signal is done by applying a long trapping pulse to prepare the atomic state superposition, and fringe detection is accomplished by optical transmission during a short second trapping pulse without any perturbation of the dark state.

Physical Review Letters•May 17, 2005•281 citations
A Raman-Ramsey Cs cell atomic clock based on Coherent Population Trapping is studied. High contrasts and narrow width Ramsey fringes are achieved by combining an original double-lambda scheme and a pulsed interrogation technique. The pulsed method allows a strong reduction of the light shift effect and avoids the power broadening. Removing a drift attributed to the cell, the clock frequency stability has been measured to be 7 × 10 -13 τ -1/2 .
We demonstrate a high-performance coherent-population-trapping (CPT) Cs vapor cell atomic clock using the push-pull optical pumping technique in the pulsed regime, allowing the detection of high-contrast and narrow Ramsey-CPT fringes. The impact of several experimental parameters onto the clock resonance and short-term fractional frequency stability, including the laser power, the cell temperature, and the Ramsey sequence parameters, has been investigated. We observe and explain the existence of a slight dependence on laser power of the central Ramsey-CPT fringe line-width in the pulsed regime. We report also that the central fringe line-width is commonly narrower than the expected Ramsey line-width given by 1/(2TR), with TR the free-evolution time, for short values of TR. The clock demonstrates a short-term fractional frequency stability at the level of 2.3×10−13 τ−1/2 up to 100 s averaging time, mainly limited by the laser amplitude modulation noise. Comparable performances are obtained in the conventional continuous wave regime, with the use of an additional laser power stabilization setup. The pulsed interaction allows to reduce significantly the clock frequency sensitivity to laser power variations, especially for high values of TR. This pulsed CPT clock, ranking among the best microwave vapor cell atomic frequency standards, could find applications in telecommunication, instrumentation, defense or satellite-based navigation systems.
This article reports on the development and short-term fractional frequency stability of a continuous-regime (CW) Cs vapor cell atomic clock based on coherent population trapping (CPT). The push-pull optical pumping technique is used to increase the number of atoms that participate to the clock transition, yielding a typical CPT resonance contrast of 25% for a CPT linewidth of about 450 Hz. The clock short-term fractional frequency stability is measured to be 3 x 10 -13 τ -1/2 up to 100 seconds averaging time, in correct agreement with the signal-to-noise ratio limit. The mid-term frequency stability results are currently mainly limited by laser power effects. The detection of high-contrast narrow Raman-Ramsey fringes is demonstrated with this setup by making the atoms interact with a light pulse sequence.
We propose a two-step pulse observation method to enhance the frequency stability of coherent population trapping (CPT) atomic clocks. The proposed method is a Raman–Ramsey scheme with low light intensity at resonance observation and provides a Ramsey-CPT resonance with both reduced frequency sensitivity to the light intensity and a high signal-to-noise ratio by reducing the repumping into a steady dark state. The resonance characteristics were calculated using density matrix analysis of a Λ-type three-level system that was modeled on the 133 Cs D 1 line, and the characteristics were also measured using a vertical-cavity surface-emitting laser and a Cs vapor cell.
We report on the mid-term stability progress of a table-top coherent population trapping (CPT) microcell atomic clock, previously limited by light-shift effects and variations of the cell's inner atmosphere. The light-shift contribution is now mitigated through the use of a pulsed symmetric auto-balanced Ramsey (SABR) interrogation technique, combined with setup temperature, laser power, and microwave power stabilization. In addition, Ne buffer gas pressure variations in the cell are now greatly reduced through the use of a micro-fabricated cell built with low permeation alumino-silicate glass (ASG) windows. Combining these approaches, the clock Allan deviation is measured to be 1.4 × 10 −12 at 10 5 s. This stability level at one day is competitive with the best current microwave microcell-based atomic clocks.
We report a high-performance pulsed coherent population trapping (CPT) Cs cell atomic clock using the implementation of a symmetric auto-balanced Ramsey (SABR) interrogation sequence. The latter method is found to reduce the light-power induced frequency shift by an order of magnitude compared to a previous experiment using a simple auto-balanced Ramsey interrogation. The contribution of this shift to the clock frequency stability is now rejected in the 10−16 range at 104 s averaging time. Additional tricks, including a compensation method to reduce the laser amplitude noise contribution and the generation of novel error signals for local oscillator frequency and phase correction, have been implemented using a FPGA-based digital electronics board in order to improve the clock short-term stability by a of factor 2. The Allan deviation of the SABR-CPT clock, extracted from a selected 3 × 104 s-long dataset, is 2 × 10−13 τ−1∕2 and averages down to the level of 2.5 × 10−15 at 104 s. These results are encouraging to stimulate the development of hot cell CPT-based clocks for industrial, scientific, and instrumentation applications.
We report the observation of Raman-Ramsey fringes using a double lambda scheme creating coherent population trapping in an atomic ensemble combined with pulsed optical radiations. The observation was made in a Cs vapor mixed with N2 buffer gas in a closed cell. The double lambda scheme is created with lin perpendicular lin polarized laser beams leading to higher contrast than the usual simple lambda scheme. The pulsed trapping technique leads to narrow fringe widths scaling as 1/(2T) with high contrasts which are no longer limited by the saturation effect. This technique operates in a different way from the classical Ramsey sequence: the signal is done by applying a long trapping pulse to prepare the atomic state superposition, and fringe detection is accomplished by optical transmission during a short second trapping pulse without any perturbation of the dark state.