Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)

Progress in Brazilian Cesium atomic fountain-BrCsF

S. A. Rodriguez, Vanderlei Salvador Bagnato, C. Bueno, Rodrigo Duarte Pechoneri, Stella Müller, Daniel Varela Magalhães

Published May 1, 2016• 3 citations
Publisher

Abstract

The goal of this work is to present new progress in the Brazilian Cesium fountain Br-CsF, which is currently back to operation after improvements in its optical system. The first result of this new stage is the Ramsey fringe showed in Figure 5. The central oscillation has a FWHM of 1.5 Hz with cycle time of 2 s and with signal noise ratio of 200. This fringe was obtained loading ~109atoms into a magneto optical trap with loading time of tl= 1.2 s.

DOI
10.1109/fcs.2016.7546818

Related papers

The optical system of the fountain clock

Xinliang Wang, Jun Ruan, Hui Zhang +7 more

This paper present an optical system for Cs atomic fountain clock that is located on a 1.2 m×1.2 m optical table. Taking advantage of this system, we trap about 108cesium atoms in the magneto-optic trap (MOT) and get the Ramsey fringe of the fountain by scanning the microwave frequency of the interrogation cavity. The full-width at half-maximum of the central fringe (FWHM) is 1.4 Hz.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 1, 2014•2 citations

An intense, highly collimated continuous Cesium fountain

N. Castagna

The realisation of cold and slow atomic beams has opened the way to a series of precision measurements of high scientific interest, as atom interferometry, Bose-Einstein Condensation and atomic fountain clocks. The latter are used since several years as reference clocks, given the high performance that they can reach both in accuracy and stability. The common philosophy in the construction of atomic fountains has been the pulsed technique, where an atoms sample is launched vertically and then falls down under the effect of the gravity. The Observatoire de Neuchâtel had a different approach and has built a fountain clock (FOCS1) operating in a continuous mode. This technique offers two main advantages: the diminution of the undesirable effects due to the atomic density (e.g. collisions between the atoms and cavity pulling) and to the noise of the local oscillator (intermodulation effect). To take full advantage of the continuous fountain approach however, we need to increase the atomic flux. The techniques chosen to reach this goal are an efficient transverse collimation together with more atoms to begin with. Here we report on a study of different transverse collimation techniques performed in a two-dimensional phase stable optical lattice (namely gray molasses and magnetically induced laser cooling) as well as the development and characterisation of a 2D-magneto-optical trap used to load the fountain. Best performances are reached in a 2D+-MOT configuration of such a pre-source, for which we detect an atomic flux 20 times greater than the one measured when the fountain is loaded by a Cs vapour. This gain could improve the atomic clock stability by a factor 6. An even better stability is expected after introducing a pre-cooling stage before performing the transverse collimation. This new configuration is currently under investigation and will be implemented in a second continuous fountain (FOCS2).

•Jan 1, 2006•0 citations

An intense, highly collimated continous cesium fountain

N. Castagna

The realisation of cold and slow atomic beams has opened the way to a series of precision measurements of high scientific interest, as atom interferometry, Bose-Einstein Condensation and atomic fountain clocks. The latter are used since several years as reference clocks, given the high performance that they can reach both in accuracy and stability. The common philosophy in the construction of atomic fountains has been the pulsed technique, where an atoms sample is launched vertically and then falls down under the effect of the gravity. The Observatoire de Neuchâtel had a different approach and has built a fountain clock (FOCS1) operating in a continuous mode. This technique offers two main advantages: the diminution of the undesirable effects due to the atomic density (e.g. collisions between the atoms and cavity pulling) and to the noise of the local oscillator (intermodulation effect). To take full advantage of the continuous fountain approach however, we need to increase the atomic flux. The techniques chosen to reach this goal are an efficient transverse collimation together with more atoms to begin with. Here we report on a study of different transverse collimation techniques performed in a two-dimensional phase stable optical lattice (namely gray molasses and magnetically induced laser cooling) as well as the development and characterisation of a 2D-magneto-optical trap used to load the fountain. Best performances are reached in a 2D+-MOT configuration of such a pre-source, for which we detect an atomic flux 20 times greater than the one measured when the fountain is loaded by a Cs vapour. This gain could improve the atomic clock stability by a factor 6. An even better stability is expected after introducing a pre-cooling stage before performing the transverse collimation. This new configuration is currently under investigation and will be implemented in a second continuous fountain (FOCS2).

•Jan 1, 2006•0 citations

Update on the development of cesium atomic fountain at NPL, India

Poonam Arora, Ashish Agarwal, Kavindra Pant +2 more

National Physical Laboratory India (NPLI) has been developing a cesium atomic fountain primary frequency standard. We have succeeded in trapping about 107Cs atoms, cool them to about 5 μK by both magneto-optical trap (MOT) and polarization gradient cooling (PGC) and launch them up by moving molasses method. We have demonstrated the fountain action by launching the atoms up to 72.9 cm up and detection of the return signal by measuring the fluorescence. Work is underway to interrogate the launched atoms with microwaves and observe Ramsey fringes.

URSI General Assembly and Scientific Symposium•Aug 1, 2011•0 citations

Progress Toward an Atomic Clock Based on a Continuous Cold Rubidium Beam

Zhixin Meng, Peiqiang Yan, Xiaojie Li +1 more

We reported on the progress toward an atomic clock based on a continuous cold 87Rb atomic beam. The atomic beam source is generated directly from a 2D+Magneto-Optical Trapping (MOT) with the flux of about 3×109atoms/s and mean longitudinal velocity of 10 m/s. The beam had a free evolution time of 9 ms over the separated distance of 90 mm, producing a 54-Hz-wide Raman-Ramsey fringe. The Signal-to-Noise ratio (SNR) of Raman-Ramsey fringes is effectively increased by modulation and demodulation methods, which offer a promising approach to improving the frequency stability of the atomic clock.

IEEE International Instrumentation and Measurement Technology Conference•May 1, 2020•2 citations

KRISS atomic fountain clock: Current status

Sang Eon Park, Long Zhe Li, Sang-Bum Lee +4 more

We present a current status of a Rb/Cs double fountain clock developing at KRISS. Fountain clock has cooling laser beam with (111)-geometry so as to enlarge cooling beam diameter. Currently few 107Cs atoms are trapped and cooled in MOT. And we observed Ramsey fringes. The linewith of central Ramsey fringe was measured to be 1 Hz with the S/N of 600.

Conference on Precision Electromagnetic Measurements•Jul 1, 2012•0 citations
The goal of this work is to present new progress in the Brazilian Cesium fountain Br-CsF, which is currently back to operation after improvements in its optical system. The first result of this new stage is the Ramsey fringe showed in Figure 5. The central oscillation has a FWHM of 1.5 Hz with cycle time of 2 s and with signal noise ratio of 200. This fringe was obtained loading ~109atoms into a magneto optical trap with loading time of tl= 1.2 s.
The realisation of cold and slow atomic beams has opened the way to a series of precision measurements of high scientific interest, as atom interferometry, Bose-Einstein Condensation and atomic fountain clocks. The latter are used since several years as reference clocks, given the high performance that they can reach both in accuracy and stability. The common philosophy in the construction of atomic fountains has been the pulsed technique, where an atoms sample is launched vertically and then falls down under the effect of the gravity. The Observatoire de Neuchâtel had a different approach and has built a fountain clock (FOCS1) operating in a continuous mode. This technique offers two main advantages: the diminution of the undesirable effects due to the atomic density (e.g. collisions between the atoms and cavity pulling) and to the noise of the local oscillator (intermodulation effect). To take full advantage of the continuous fountain approach however, we need to increase the atomic flux. The techniques chosen to reach this goal are an efficient transverse collimation together with more atoms to begin with. Here we report on a study of different transverse collimation techniques performed in a two-dimensional phase stable optical lattice (namely gray molasses and magnetically induced laser cooling) as well as the development and characterisation of a 2D-magneto-optical trap used to load the fountain. Best performances are reached in a 2D+-MOT configuration of such a pre-source, for which we detect an atomic flux 20 times greater than the one measured when the fountain is loaded by a Cs vapour. This gain could improve the atomic clock stability by a factor 6. An even better stability is expected after introducing a pre-cooling stage before performing the transverse collimation. This new configuration is currently under investigation and will be implemented in a second continuous fountain (FOCS2).
The realisation of cold and slow atomic beams has opened the way to a series of precision measurements of high scientific interest, as atom interferometry, Bose-Einstein Condensation and atomic fountain clocks. The latter are used since several years as reference clocks, given the high performance that they can reach both in accuracy and stability. The common philosophy in the construction of atomic fountains has been the pulsed technique, where an atoms sample is launched vertically and then falls down under the effect of the gravity. The Observatoire de Neuchâtel had a different approach and has built a fountain clock (FOCS1) operating in a continuous mode. This technique offers two main advantages: the diminution of the undesirable effects due to the atomic density (e.g. collisions between the atoms and cavity pulling) and to the noise of the local oscillator (intermodulation effect). To take full advantage of the continuous fountain approach however, we need to increase the atomic flux. The techniques chosen to reach this goal are an efficient transverse collimation together with more atoms to begin with. Here we report on a study of different transverse collimation techniques performed in a two-dimensional phase stable optical lattice (namely gray molasses and magnetically induced laser cooling) as well as the development and characterisation of a 2D-magneto-optical trap used to load the fountain. Best performances are reached in a 2D+-MOT configuration of such a pre-source, for which we detect an atomic flux 20 times greater than the one measured when the fountain is loaded by a Cs vapour. This gain could improve the atomic clock stability by a factor 6. An even better stability is expected after introducing a pre-cooling stage before performing the transverse collimation. This new configuration is currently under investigation and will be implemented in a second continuous fountain (FOCS2).
National Physical Laboratory India (NPLI) has been developing a cesium atomic fountain primary frequency standard. We have succeeded in trapping about 107Cs atoms, cool them to about 5 μK by both magneto-optical trap (MOT) and polarization gradient cooling (PGC) and launch them up by moving molasses method. We have demonstrated the fountain action by launching the atoms up to 72.9 cm up and detection of the return signal by measuring the fluorescence. Work is underway to interrogate the launched atoms with microwaves and observe Ramsey fringes.
We reported on the progress toward an atomic clock based on a continuous cold 87Rb atomic beam. The atomic beam source is generated directly from a 2D+Magneto-Optical Trapping (MOT) with the flux of about 3×109atoms/s and mean longitudinal velocity of 10 m/s. The beam had a free evolution time of 9 ms over the separated distance of 90 mm, producing a 54-Hz-wide Raman-Ramsey fringe. The Signal-to-Noise ratio (SNR) of Raman-Ramsey fringes is effectively increased by modulation and demodulation methods, which offer a promising approach to improving the frequency stability of the atomic clock.