Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEEE International Instrumentation and Measurement Technology Conference

Progress Toward an Atomic Clock Based on a Continuous Cold Rubidium Beam

Zhixin Meng, Peiqiang Yan, Xiaojie Li, Yanying Feng

Published May 1, 2020• 3 citations
Publisher

Abstract

We reported on the progress toward an atomic clock based on a continuous cold 87Rb atomic beam. The atomic beam source is generated directly from a 2D+Magneto-Optical Trapping (MOT) with the flux of about 3×109atoms/s and mean longitudinal velocity of 10 m/s. The beam had a free evolution time of 9 ms over the separated distance of 90 mm, producing a 54-Hz-wide Raman-Ramsey fringe. The Signal-to-Noise ratio (SNR) of Raman-Ramsey fringes is effectively increased by modulation and demodulation methods, which offer a promising approach to improving the frequency stability of the atomic clock.

DOI
10.1109/i2mtc43012.2020.9128474

Related papers

An intense 87Rb cold atomic source for atom interferometry

Li Yingying, Xiong Jijun, Zhikun Jiang

We present the implementation and characterization of a slow, intense, and collimated rubidium atomic source for atom interferometry. The continuous87Rb cold atomic beam is produced by a new compact two-dimensional magneto-optical trap. And it is based on the 2D+MOT design but a much smaller size and a higher flux compared to our original LVIS system. The on-line detecting system developed over a combination of time-of-flight and fluorescence methods is used to optimize the beam parameters. The dependence of the beam flux on detuning and power are investigated in detail respectively, for cooling and pushing laser. The re-pumping laser power influence is also considered. With aError! Reference source not found.10 G/cm magnetic gradient, 3ΓError! Reference source not found. red detuning from resonance for cooling laser and 5ΓError! Reference source not found. red detuning for pushing laser, the obtained cold atomic beam has a high flux of 4.7×109atoms/s Error! Reference source not found. Error! Reference source not found. It has a narrow longitudinal velocity distribution with mean velocity 10 m/s and full width at half maximum (FWHM)Error! Reference source not found.2 m/sError! Reference source not found. The two-photo stimulated Raman transitions both in Doppler-free and Doppler-sensitive modes are first proceeded, and stable Raman-Ramsey fringes are achieved with twon/2 Error! Reference source not found. Raman pulses.

International Conference on Optoelectronics and Microelectronics•Jul 1, 2015•0 citations

An optically pumped atomic clock based on a continuous slow cesium beam

Weibin Xie, Qing Wang, Xuan He +8 more

Herein, we report the scheme of an optically pumped atomic clock based on a cold cesium atomic beam source. We propose the laser system and physical mechanism of this atomic clock, wherein the atomic beam travels in an upper parabolic trajectory, thereby eliminating the light shift effect. In the experiments, when the length of the free evolution region was 167 mm, the line width of the Ramsey fringe was 37 Hz. When the expected signal-to-noise ratio of the Ramsey fringe that can be achieved is 36,000, the expected short-term frequency stability is about 3.6 × 10–14/√τ, which is significantly higher than that of a conventional optically pumped cesium clock of similar volume.

Frontiers in Physics•Dec 13, 2022•5 citations

An Atom SAGNAC Interferometer With Continuous Cold Atomic Beam Sources

Zhixin Meng, Peiqiang Yan, Xiaojie Li +2 more

We present an atom interferometer with two counter-propagating continuous cold atomic beam of87Rb atoms as a gyroscope with high accuracy and high sampling rates. Two atomic beam sources are generated directly from 2D+Magneto-Optical Trappings (MOTs) with the flux of about 3×109atoms/s and mean longitudinal velocity of 10 m/s. Raman-Ramsey interference is experimentally demonstrated with the central fringe width of 54 Hz.

IEEE International Symposium on Inertial Sensors and Systems (INERTIAL)•Mar 1, 2020•4 citations

A cold-atom beam clock based on coherent population trapping

John Elgin, Thomas P. Heavner, John E. Kitching +3 more

We present results from an atomic clock that employs a beam of cold 87Rb atoms and spatially separated (Ramsey) coherent population trapping interrogation of the hyperfine clock transition at 6.834 GHz. The cold atomic beam is generated through the use of a 2D+-magneto-optical trap. The interrogation is performed on the D2 line of 87Rb, and the optical fields use a counter-propagating σ+–σ− probing scheme. The use of cold atoms allows for relatively narrow Ramsey fringes even for a small spatial separation between the two interrogation zones (4.6 cm). The resulting clock has a short-term stability of 3×10−11/τ.

Applied Physics Letters•Jul 15, 2019•35 citations

Towards a Raman-Ramsey Clock based on a Cold Cesium Beam

Chenfei Wu, Xueshu Yan, Jianwei Zhang +1 more

The continuous cold atomic clocks have the potential to overcome the Dick effect and to develop compact devices. In this paper, we present a process towards a Raman-Ramsey clock based on a continuous beam of cold cesium using optical separated oscillatory fields instead of a microwave cavity. The Raman-Ramsey fringes for clock transition are observed with a contrast of ~68%, and the central fringe width is ~175 Hz for the interaction-zone separation of 30 mm.

Joint Conference of the IEEE International Frequency Control Symposium and International Symposium on Applications of Ferroelectrics (IFCS-ISAF)•Jul 1, 2020•0 citations

Compact, Continuous-Beam, Cold-Atom Clock for Satellite Applications

H. Wang, Walter F. Buell

Highly stable atomic frequency standards are of increasing importance for a variety of space applications, ranging from communication to navigation and time transfer to tests of fundamental science. The requirements for an atomic clock vary significantly depending on the application, and for many space systems, compactness and robust design are at a premium, and stability dominates over absolute accuracy. We report on progress with our design for a compact laser-cooled Cs- beam atomic clock suitable for satellite applications such as GPS. The basic design features a continuous, cold atomic beam extracted from a magneto-optic trap (MOT). This cold atomic beam is then to be used in a laser-pumped Ramsey clock, with the clock signal derived from either a microwave C-field or, alternatively, by Raman resonance between the Ramsey fields. In order to reduce light shifts from the MOT light and improve signal-to-noise, the atomic beam will be optically deflected and transversely cooled upon extraction from the MOT. We estimate that the shot-noise-limited stability achievable with this physics package can be 2 to 3 orders of magnitude better than current Cs-beam clocks used in satellite applications. We present our experimental progress towards a working frequency standard, including characterization of our six-beam magneto-optic cold atom trap and production and characterization of a cold atomic beam.

•Jun 30, 2002•1 citation
We reported on the progress toward an atomic clock based on a continuous cold 87Rb atomic beam. The atomic beam source is generated directly from a 2D+Magneto-Optical Trapping (MOT) with the flux of about 3×109atoms/s and mean longitudinal velocity of 10 m/s. The beam had a free evolution time of 9 ms over the separated distance of 90 mm, producing a 54-Hz-wide Raman-Ramsey fringe. The Signal-to-Noise ratio (SNR) of Raman-Ramsey fringes is effectively increased by modulation and demodulation methods, which offer a promising approach to improving the frequency stability of the atomic clock.
We present the implementation and characterization of a slow, intense, and collimated rubidium atomic source for atom interferometry. The continuous87Rb cold atomic beam is produced by a new compact two-dimensional magneto-optical trap. And it is based on the 2D+MOT design but a much smaller size and a higher flux compared to our original LVIS system. The on-line detecting system developed over a combination of time-of-flight and fluorescence methods is used to optimize the beam parameters. The dependence of the beam flux on detuning and power are investigated in detail respectively, for cooling and pushing laser. The re-pumping laser power influence is also considered. With aError! Reference source not found.10 G/cm magnetic gradient, 3ΓError! Reference source not found. red detuning from resonance for cooling laser and 5ΓError! Reference source not found. red detuning for pushing laser, the obtained cold atomic beam has a high flux of 4.7×109atoms/s Error! Reference source not found. Error! Reference source not found. It has a narrow longitudinal velocity distribution with mean velocity 10 m/s and full width at half maximum (FWHM)Error! Reference source not found.2 m/sError! Reference source not found. The two-photo stimulated Raman transitions both in Doppler-free and Doppler-sensitive modes are first proceeded, and stable Raman-Ramsey fringes are achieved with twon/2 Error! Reference source not found. Raman pulses.
Herein, we report the scheme of an optically pumped atomic clock based on a cold cesium atomic beam source. We propose the laser system and physical mechanism of this atomic clock, wherein the atomic beam travels in an upper parabolic trajectory, thereby eliminating the light shift effect. In the experiments, when the length of the free evolution region was 167 mm, the line width of the Ramsey fringe was 37 Hz. When the expected signal-to-noise ratio of the Ramsey fringe that can be achieved is 36,000, the expected short-term frequency stability is about 3.6 × 10–14/√τ, which is significantly higher than that of a conventional optically pumped cesium clock of similar volume.
We present results from an atomic clock that employs a beam of cold 87Rb atoms and spatially separated (Ramsey) coherent population trapping interrogation of the hyperfine clock transition at 6.834 GHz. The cold atomic beam is generated through the use of a 2D+-magneto-optical trap. The interrogation is performed on the D2 line of 87Rb, and the optical fields use a counter-propagating σ+–σ− probing scheme. The use of cold atoms allows for relatively narrow Ramsey fringes even for a small spatial separation between the two interrogation zones (4.6 cm). The resulting clock has a short-term stability of 3×10−11/τ.
Highly stable atomic frequency standards are of increasing importance for a variety of space applications, ranging from communication to navigation and time transfer to tests of fundamental science. The requirements for an atomic clock vary significantly depending on the application, and for many space systems, compactness and robust design are at a premium, and stability dominates over absolute accuracy. We report on progress with our design for a compact laser-cooled Cs- beam atomic clock suitable for satellite applications such as GPS. The basic design features a continuous, cold atomic beam extracted from a magneto-optic trap (MOT). This cold atomic beam is then to be used in a laser-pumped Ramsey clock, with the clock signal derived from either a microwave C-field or, alternatively, by Raman resonance between the Ramsey fields. In order to reduce light shifts from the MOT light and improve signal-to-noise, the atomic beam will be optically deflected and transversely cooled upon extraction from the MOT. We estimate that the shot-noise-limited stability achievable with this physics package can be 2 to 3 orders of magnitude better than current Cs-beam clocks used in satellite applications. We present our experimental progress towards a working frequency standard, including characterization of our six-beam magneto-optic cold atom trap and production and characterization of a cold atomic beam.