Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEEE International Symposium on Inertial Sensors and Systems (INERTIAL)

An Atom SAGNAC Interferometer With Continuous Cold Atomic Beam Sources

Zhixin Meng, Peiqiang Yan, Xiaojie Li, Kang Wu, Yanying Feng

Published Mar 1, 2020• 2 citations
Publisher

Abstract

We present an atom interferometer with two counter-propagating continuous cold atomic beam of87Rb atoms as a gyroscope with high accuracy and high sampling rates. Two atomic beam sources are generated directly from 2D+Magneto-Optical Trappings (MOTs) with the flux of about 3×109atoms/s and mean longitudinal velocity of 10 m/s. Raman-Ramsey interference is experimentally demonstrated with the central fringe width of 54 Hz.

DOI
10.1109/inertial48129.2020.9090088

Related papers

A continuous cold atomic beam interferometer

Hongbo Xue, Yanying Feng, Shu Chen +4 more

We demonstrate an atom interferometer that uses a laser-cooled continuous beam of 87Rb atoms having velocities of 10–20 m/s. With spatially separated Raman beams to coherently manipulate the atomic wave packets, Mach–Zehnder interference fringes are observed at an interference distance of 2L = 19 mm. The apparatus operates within a small enclosed area of 0.07 mm2 at a bandwidth of 190 Hz with a deduced sensitivity of 7.8×10−5 rad/s/Hz for rotations. Using a low-velocity continuous atomic source in an atom interferometer enables high sampling rates and bandwidths without sacrificing sensitivity and compactness, which are important for applications in real dynamic environments.

arXiv:1402.3822•Journal of Applied Physics•Mar 2, 2015•37 citations

Progress Toward an Atomic Clock Based on a Continuous Cold Rubidium Beam

Zhixin Meng, Peiqiang Yan, Xiaojie Li +1 more

We reported on the progress toward an atomic clock based on a continuous cold 87Rb atomic beam. The atomic beam source is generated directly from a 2D+Magneto-Optical Trapping (MOT) with the flux of about 3×109atoms/s and mean longitudinal velocity of 10 m/s. The beam had a free evolution time of 9 ms over the separated distance of 90 mm, producing a 54-Hz-wide Raman-Ramsey fringe. The Signal-to-Noise ratio (SNR) of Raman-Ramsey fringes is effectively increased by modulation and demodulation methods, which offer a promising approach to improving the frequency stability of the atomic clock.

IEEE International Instrumentation and Measurement Technology Conference•May 1, 2020•2 citations

An intense 87Rb cold atomic source for atom interferometry

Li Yingying, Xiong Jijun, Zhikun Jiang

We present the implementation and characterization of a slow, intense, and collimated rubidium atomic source for atom interferometry. The continuous87Rb cold atomic beam is produced by a new compact two-dimensional magneto-optical trap. And it is based on the 2D+MOT design but a much smaller size and a higher flux compared to our original LVIS system. The on-line detecting system developed over a combination of time-of-flight and fluorescence methods is used to optimize the beam parameters. The dependence of the beam flux on detuning and power are investigated in detail respectively, for cooling and pushing laser. The re-pumping laser power influence is also considered. With aError! Reference source not found.10 G/cm magnetic gradient, 3ΓError! Reference source not found. red detuning from resonance for cooling laser and 5ΓError! Reference source not found. red detuning for pushing laser, the obtained cold atomic beam has a high flux of 4.7×109atoms/s Error! Reference source not found. Error! Reference source not found. It has a narrow longitudinal velocity distribution with mean velocity 10 m/s and full width at half maximum (FWHM)Error! Reference source not found.2 m/sError! Reference source not found. The two-photo stimulated Raman transitions both in Doppler-free and Doppler-sensitive modes are first proceeded, and stable Raman-Ramsey fringes are achieved with twon/2 Error! Reference source not found. Raman pulses.

International Conference on Optoelectronics and Microelectronics•Jul 1, 2015•0 citations

Dual-atomic-beam matter-wave gyroscope

T. L. Gustavson, Philippe Bouyer, Mark A. Kasevich

We report improvements to our atom-interferometer based Sagnac gyroscope which uses stimulated Raman transitions to manipulate atomic wavepackets of cesium atoms. Using counter-propagating high-flux atomic beams, we form two interferometers with opposite Sagnac phase shifts that share key components such as Raman atomic state manipulation beams. Subtracting the two interferometer signals allows the common-mode rejection of spurious noise sources and various systematic effects. Preliminary results indicate a short term sensitivity of 3 X 10-9 (rad/s) (root) Hz.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•May 15, 1998•15 citations

Demonstration of a Sagnac-Type Cold Atom Interferometer with Stimulated Raman Transitions

Wang Ping, Runbing Li, Hui Yan +2 more

Cold-matter-wave Sagnac interferometers possess many advantages over their thermal atomic beam counterparts when they are used as precise inertial sensors. We report a realization of a Sagnac-type interferometer with cold atoms. Cold rubidium atoms are prepared in a magneto-optical trap and are pushed by resonant laser pulse to form slow atomic beam. In the interference region, atomic wave packets are coherently manipulated using π/2−π−π/2 Raman pulse sequences. Interference fringes with maximum contrast of 37% are observed experimentally.

Chinese Physics Letters•Jan 1, 2007•23 citations

A continuous cold rubidium atomic beam with enhanced flux and tunable velocity

Shengzhe Wang, Zhixin Meng, and Peiqiang Yan +2 more

We present a cold atomic beam source based on a two-dimensional (2D)+ magneto-optical trap (MOT), capable of generating a continuous cold beam of 87Rb atoms with a flux up to 4.3*10^9 atoms/s, a mean velocity of 10.96(2.20) m/s, and a transverse temperature of 16.90(1.56) uK. Investigating the influence of high cooling laser intensity, we observe a significant population loss of atoms to hyperfine-level dark states. To account for this, we employ a multiple hyperfine level model to calculate the cooling efficiency associated with the population in dark states, subsequently modifying the scattering force. Simulations of beam flux at different cooling and repumping laser intensities using the modified scattering force are in agreement with experimental results. Optimizing repumping and cooling intensities enhances the flux by 50%. The influence of phase modulation on both the pushing and cooling lasers is experimentally studied, revealing that the mean velocity of cold atoms can be tuned from 9.5 m/s to 14.6 m/s with a phase-modulated pushing laser. The versatility of this continuous beam source, featuring high flux, controlled velocity, and narrow transverse temperature, renders it valuable for applications in atom interferometers and clocks, ultimately enhancing bandwidth, sensitivity, and signal contrast in these devices.

arXiv:2312.12027•Dec 19, 2023•0 citations
We present an atom interferometer with two counter-propagating continuous cold atomic beam of87Rb atoms as a gyroscope with high accuracy and high sampling rates. Two atomic beam sources are generated directly from 2D+Magneto-Optical Trappings (MOTs) with the flux of about 3×109atoms/s and mean longitudinal velocity of 10 m/s. Raman-Ramsey interference is experimentally demonstrated with the central fringe width of 54 Hz.
We demonstrate an atom interferometer that uses a laser-cooled continuous beam of 87Rb atoms having velocities of 10–20 m/s. With spatially separated Raman beams to coherently manipulate the atomic wave packets, Mach–Zehnder interference fringes are observed at an interference distance of 2L = 19 mm. The apparatus operates within a small enclosed area of 0.07 mm2 at a bandwidth of 190 Hz with a deduced sensitivity of 7.8×10−5 rad/s/Hz for rotations. Using a low-velocity continuous atomic source in an atom interferometer enables high sampling rates and bandwidths without sacrificing sensitivity and compactness, which are important for applications in real dynamic environments.
We reported on the progress toward an atomic clock based on a continuous cold 87Rb atomic beam. The atomic beam source is generated directly from a 2D+Magneto-Optical Trapping (MOT) with the flux of about 3×109atoms/s and mean longitudinal velocity of 10 m/s. The beam had a free evolution time of 9 ms over the separated distance of 90 mm, producing a 54-Hz-wide Raman-Ramsey fringe. The Signal-to-Noise ratio (SNR) of Raman-Ramsey fringes is effectively increased by modulation and demodulation methods, which offer a promising approach to improving the frequency stability of the atomic clock.
We present the implementation and characterization of a slow, intense, and collimated rubidium atomic source for atom interferometry. The continuous87Rb cold atomic beam is produced by a new compact two-dimensional magneto-optical trap. And it is based on the 2D+MOT design but a much smaller size and a higher flux compared to our original LVIS system. The on-line detecting system developed over a combination of time-of-flight and fluorescence methods is used to optimize the beam parameters. The dependence of the beam flux on detuning and power are investigated in detail respectively, for cooling and pushing laser. The re-pumping laser power influence is also considered. With aError! Reference source not found.10 G/cm magnetic gradient, 3ΓError! Reference source not found. red detuning from resonance for cooling laser and 5ΓError! Reference source not found. red detuning for pushing laser, the obtained cold atomic beam has a high flux of 4.7×109atoms/s Error! Reference source not found. Error! Reference source not found. It has a narrow longitudinal velocity distribution with mean velocity 10 m/s and full width at half maximum (FWHM)Error! Reference source not found.2 m/sError! Reference source not found. The two-photo stimulated Raman transitions both in Doppler-free and Doppler-sensitive modes are first proceeded, and stable Raman-Ramsey fringes are achieved with twon/2 Error! Reference source not found. Raman pulses.
We report improvements to our atom-interferometer based Sagnac gyroscope which uses stimulated Raman transitions to manipulate atomic wavepackets of cesium atoms. Using counter-propagating high-flux atomic beams, we form two interferometers with opposite Sagnac phase shifts that share key components such as Raman atomic state manipulation beams. Subtracting the two interferometer signals allows the common-mode rejection of spurious noise sources and various systematic effects. Preliminary results indicate a short term sensitivity of 3 X 10-9 (rad/s) (root) Hz.
Cold-matter-wave Sagnac interferometers possess many advantages over their thermal atomic beam counterparts when they are used as precise inertial sensors. We report a realization of a Sagnac-type interferometer with cold atoms. Cold rubidium atoms are prepared in a magneto-optical trap and are pushed by resonant laser pulse to form slow atomic beam. In the interference region, atomic wave packets are coherently manipulated using π/2−π−π/2 Raman pulse sequences. Interference fringes with maximum contrast of 37% are observed experimentally.
We present a cold atomic beam source based on a two-dimensional (2D)+ magneto-optical trap (MOT), capable of generating a continuous cold beam of 87Rb atoms with a flux up to 4.3*10^9 atoms/s, a mean velocity of 10.96(2.20) m/s, and a transverse temperature of 16.90(1.56) uK. Investigating the influence of high cooling laser intensity, we observe a significant population loss of atoms to hyperfine-level dark states. To account for this, we employ a multiple hyperfine level model to calculate the cooling efficiency associated with the population in dark states, subsequently modifying the scattering force. Simulations of beam flux at different cooling and repumping laser intensities using the modified scattering force are in agreement with experimental results. Optimizing repumping and cooling intensities enhances the flux by 50%. The influence of phase modulation on both the pushing and cooling lasers is experimentally studied, revealing that the mean velocity of cold atoms can be tuned from 9.5 m/s to 14.6 m/s with a phase-modulated pushing laser. The versatility of this continuous beam source, featuring high flux, controlled velocity, and narrow transverse temperature, renders it valuable for applications in atom interferometers and clocks, ultimately enhancing bandwidth, sensitivity, and signal contrast in these devices.