The realisation of cold and slow atomic beams has opened the way to a series of precision measurements of high scientific interest, as atom interferometry, Bose-Einstein Condensation and atomic fountain clocks. The latter are used since several years as reference clocks, given the high performance that they can reach both in accuracy and stability. The common philosophy in the construction of atomic fountains has been the pulsed technique, where an atoms sample is launched vertically and then falls down under the effect of the gravity. The Observatoire de Neuchâtel had a different approach and has built a fountain clock (FOCS1) operating in a continuous mode. This technique offers two main advantages: the diminution of the undesirable effects due to the atomic density (e.g. collisions between the atoms and cavity pulling) and to the noise of the local oscillator (intermodulation effect). To take full advantage of the continuous fountain approach however, we need to increase the atomic flux. The techniques chosen to reach this goal are an efficient transverse collimation together with more atoms to begin with. Here we report on a study of different transverse collimation techniques performed in a two-dimensional phase stable optical lattice (namely gray molasses and magnetically induced laser cooling) as well as the development and characterisation of a 2D-magneto-optical trap used to load the fountain. Best performances are reached in a 2D+-MOT configuration of such a pre-source, for which we detect an atomic flux 20 times greater than the one measured when the fountain is loaded by a Cs vapour. This gain could improve the atomic clock stability by a factor 6. An even better stability is expected after introducing a pre-cooling stage before performing the transverse collimation. This new configuration is currently under investigation and will be implemented in a second continuous fountain (FOCS2).
The realisation of cold and slow atomic beams has opened the way to a series of precision measurements of high scientific interest, as atom interferometry, Bose-Einstein Condensation and atomic fountain clocks. The latter are used since several years as reference clocks, given the high performance that they can reach both in accuracy and stability. The common philosophy in the construction of atomic fountains has been the pulsed technique, where an atoms sample is launched vertically and then falls down under the effect of the gravity. The Observatoire de Neuchâtel had a different approach and has built a fountain clock (FOCS1) operating in a continuous mode. This technique offers two main advantages: the diminution of the undesirable effects due to the atomic density (e.g. collisions between the atoms and cavity pulling) and to the noise of the local oscillator (intermodulation effect). To take full advantage of the continuous fountain approach however, we need to increase the atomic flux. The techniques chosen to reach this goal are an efficient transverse collimation together with more atoms to begin with. Here we report on a study of different transverse collimation techniques performed in a two-dimensional phase stable optical lattice (namely gray molasses and magnetically induced laser cooling) as well as the development and characterisation of a 2D-magneto-optical trap used to load the fountain. Best performances are reached in a 2D+-MOT configuration of such a pre-source, for which we detect an atomic flux 20 times greater than the one measured when the fountain is loaded by a Cs vapour. This gain could improve the atomic clock stability by a factor 6. An even better stability is expected after introducing a pre-cooling stage before performing the transverse collimation. This new configuration is currently under investigation and will be implemented in a second continuous fountain (FOCS2).
The realisation of cold and slow atomic beams has opened the way to a series of precision measurements of high scientific interest, as atom interferometry, Bose-Einstein Condensation and atomic fountain clocks. The latter are used since several years as reference clocks, given the high performance that they can reach both in accuracy and stability. The common philosophy in the construction of atomic fountains has been the pulsed technique, where an atoms sample is launched vertically and then falls down under the effect of the gravity. The Observatoire de Neuchâtel had a different approach and has built a fountain clock (FOCS1) operating in a continuous mode. This technique offers two main advantages: the diminution of the undesirable effects due to the atomic density (e.g. collisions between the atoms and cavity pulling) and to the noise of the local oscillator (intermodulation effect). To take full advantage of the continuous fountain approach however, we need to increase the atomic flux. The techniques chosen to reach this goal are an efficient transverse collimation together with more atoms to begin with. Here we report on a study of different transverse collimation techniques performed in a two-dimensional phase stable optical lattice (namely gray molasses and magnetically induced laser cooling) as well as the development and characterisation of a 2D-magneto-optical trap used to load the fountain. Best performances are reached in a 2D+-MOT configuration of such a pre-source, for which we detect an atomic flux 20 times greater than the one measured when the fountain is loaded by a Cs vapour. This gain could improve the atomic clock stability by a factor 6. An even better stability is expected after introducing a pre-cooling stage before performing the transverse collimation. This new configuration is currently under investigation and will be implemented in a second continuous fountain (FOCS2).
The accelerated development of laser methods for manipulating the internal state and motion of atoms, and the recent primary evaluation in France of a cesium frequency standard using cold atoms in an atomic fountain configuration, allow the frontiers of time metrology, accuracy, and stability to be pushed near parts in the 1016 level, a factor of 100 over the present primary laboratory clocks. These positive results revived the development of more accurate cesium atomic clocks, and the Institute of National Measurement Standards (INMS), of the National Research Council of Canada (NRC) is undertaking a cesium-fountain project aimed at reaching these new levels of accuracy and stability. This paper reviews its present status. To appreciate the considerable impact of cold atoms in time and frequency metrology, we begin by recalling the background principles of traditional cesium frequency standards, their typical performance and main limitations. After introducing the important theoretical results essential to understanding the techniques of laser cooling and magneto-optical trapping, we focus on describing the characterization and control of our magneto-optical trap (MOT) and report the parameters that allow us to fill the trap with a few million atoms in less than a second and cool them to a temperature lower than 5 muK using optical molasses. We will describe the specifics of our cesium-fountain prototype, which operates with a 2-dimensional moving molasses. This special configuration is applicable for multipulse operation of the fountain, which can greatly relax the local oscillator requirements for time keeping. Finally, progress toward our objective of launching cooled atoms, at a rate of one ensemble per second, at speeds of 7 m/s, for a fountain with an interrogation time of about 1 s, will be analysed.PACS Nos.: 06.20, 06.30, and 32.80P
We present a 2D magneto-optical trap (MOT) that uses an innovative simple optical configuration. Instead of mirrors and quarter-wave plates we use metal-coated retro-reflecting prisms so as to recycle the optical power of the cooling laser beam. We have characterised this source for three different configurations: with and without transverse magnetic field gradient, as well as with a pusher beam to produce a 2D+-MOT. The longitudinal velocity is about 25 m·s-1, with a transverse velocity spread ≤ 1 m·s-1, while the typical atomic flux density can be as much as 1.3×1014 at·s-1·m-2 for a cesium vapour pressure of ~4×10-8 mbar in the source. We use this low velocity atomic beam, instead of thermal vapour, to load a 3D moving optical molasses that launches a continuous cold cesium fountain. We achieve a gain of a factor ~ 20 in the fountain's atomic flux.
We describe the design and performance of a slow atom source based on a 2D magneto-optical trap (MOT) that uses an innovative simple optical configuration. Metal-coated retro-reflecting prisms replace mirrors and quarter-wave plates so the optical power of the cooling laser beam is recycled. This source has been characterised for three different configurations: with and without transverse magnetic field gradient, and with a pusher beam to obtain a 2D+-MOT. The longitudinal velocity is of the order of 25 m·s−1, with a transverse velocity spread ≤1 m·s−1, while the typical atomic flux density obtained is up to 1.3×1014 at ·s−1·m−2 for a cesium vapour pressure of ~4×10−8 mbar in the source. We use this slow atom beam, instead of cesium vapour, to load a 3D moving optical molasses that feeds a continuous cold atom fountain. We obtain a gain of a factor ~20 in the atomic flux launched by the fountain.
To achieve a primary frequency standard based on a continuous fountain of laser cooled cesium atoms, we report on the production of a bright, slow and cold continuous atomic beam. Atoms are cooled from a thermal vapor in a 45/spl deg/ laser geometry and launched directly from the optical molasses by the moving molasses technique. The effects of the source fluorescence on the continuous beam (average velocity, temperature and flux) have been observed, and ways to optimize simultaneously the atomic capture and the continuous beam are presented. Flux measurements rise to 2/spl times/10/sup 8/ at/s from a 2D magneto-optical trap at 7 m/s. The initial velocity is easily tunable from 1 to 10 m/s. If the longitudinal temperature is about 70 /spl mu/K, additional transverse cooling even reduces the transverse temperature in one dimension below 30 /spl mu/K. By extrapolating the obtained atomic flux to the continuous fountain under construction, we expect a short-term stability of 7/spl times/10/sup -14//spl tau//sup -1/2/. Other applications of continuous beams of cold atoms are suggested.
This thesis describes the development of a laser-cooling experiment aimed at efficient transfer of cold atoms over a short distance, for loading into a conservative atom trap. We detail the construction of a 3D magneto-optical trap (MOT) and perform characterisation measurements to optimise the number and temperature of the cold atoms. The atoms are launched vertically in a fountain from the MOT using a 'moving molasses' technique and a red-detuned far-off-resonant laser beam is used to guide them into an UHV chamber. Loading into the guiding beam is optimised with respect to the beam and MOT parameters. We demonstrate a maximum loading of 20% and guiding over a distance of more than 10 cm without loss of atoms. The atoms are delivered to the UHV chamber in a cloud with a transverse dimension of order 200 #mu#m. We discuss the extension to continuous operation of the guided atomic fountain. The 3D MOT is replaced by a funnel with 2D trapping and 3D cooling which continuously extracts the cold atoms using moving molasses. A comparison between the flux of guided atoms obtained in a pulsed fashion from the 3D MOT and continuously from the funnel indicate that the pulsed case is a factor of ten more efficient. The difference is due to inferior loading from the funnel. The optically guided fountain is used to load an optical dipole trap in the UHV chamber, using an 'optical trap door'. No additional cooling is required. The dynamics of the atoms in the optical dipole trap are studied. We discuss multiple loading of a conservative trap with the view of accumulating more atoms than can be obtained in a MOT. (author)